Altronix NetWay8GL Network Managed PoE Midspan Installation Guide
- June 3, 2024
- Altronix
Table of Contents
P oE Managed Midspan Solution for
Standard Network Infrastructure
NetWay8GL
– 8-Port Managed Hi-PoE Midspan Injector
– 240W total power
Installation Guide
NetWay8GL Network Managed PoE Midspan
DOC#: NETGL Rev. 110719
Installing Company: ___ Service Rep. Name:
Address: _____ Phone #:
Overview:
Altronix NetWay8GL Networked Managed Midspan provides PoE/PoE+/Hi PoE (up to
60W) power per port and passes data at 10/100/1000 Mbps at distances up to
100m. Features also include an integral battery charger for applications
requiring backup and embedded LINQ Technology to monitor, control, and report
power and diagnostics from
anywhere.
Features:
Input:
- 115VAC, 60Hz, 3.25A or 230VAC, 50/60Hz, 2.0A.
Power:
-
The unit supplies PoE output voltage (55V) and up to 60W max. full power per port.
Total power: 240W. -
IEEE 802.3af and IEEE 802.3at compliant.
-
Short circuit protection.
Ethernet:
- Eight (8) ports for cameras/edge devices over ethernet.
- Wire type: 4-pair CAT5e and higher.
- Speed: 10/100/1000 Mbps.
Functions:
- Auto detection and protection of legacy non-PoE cameras/edge devices.
Battery Backup:
- Built-in battery charger (optional rack mount battery enclosure – RE2).
- Automatic switchover to stand-by battery when AC fails.
LINQ Technology:
- SSL (Secure Socket Layer) security encryption.
- User-level security.
- Built-in IP management allows for remote camera reset and monitoring.
- Provides local and/or remote access to critical information via LAN/WAN
- Email and Windows Dashboard Alert notifications report real-time diagnostics.
- The event log tracks history.
Accessories:
NetWayXT:
- The PoE repeater module extends the data range by 100m.
NetWayXTX:
- PoE/PoE+ repeater module extends the data range by 100m.
RE2:
- Rack Mount Battery Enclosure accommodates up to four (4) 12VDC/7AH batteries.
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code
(ANSI/NFPA70), local codes, and the authorities having jurisdiction. NetWay8GL
unit is not intended to be connected to outside plant leads. These products
are for indoor use only and must be installed within protected premises. If
the battery bracket is removed, then the unit must be installed in a
restricted access area (Fig. 1b, pg. 3).
-
Attach mounting brackets to the NetWay8GL unit for rack or wall mount installation (Fig. 5 or 6, pg. 8). Affix rubber pads to NetWay8GL for shelf installation (Fig. 7, pg. 8).
-
Secure the unit in a rack or on a wall, or place the unit on a shelf as desired. Note: The following factors should be taken into consideration when installing these rack mount units: a. The unit is to be installed in a space where the maximum ambient temperature does not exceed 104ºF (40ºC). b. Take care to ensure that there is sufficient airflow around the unit and that obstructions do not impede it. c. When mounting units in a rack, take care to avoid uneven loading which can cause a hazardous conditions.
-
Plug the grounded AC line cord (included) into the IEC 320 connector of the NetWay8GL unit (Fig. 2g, pg. Plug the unit into a reliable earth-grounded socket. When using multiple units, the sum of the individual nameplate ratings should not exceed the supply circuit rating. Do not connect to a receptacle controlled by a switch.
-
Connect structured cables from port marked [IN] on NetWay8GL to the corresponding inputs of an ethernet switch or video server (Fig. 2b, pg. 4, Fig. 4, pg.
Note: All cabling and wire must be UL Listed and/or Recognized as wire suitable for their application. -
Connect structured cables from port marked [OUT] on NetWay8GL to PoE-compliant camera/edge devices (Fig. 2a, pg. 4, Fig. 4, pg. 6).
-
When the use of stand-by batteries is required, they must be sealed with lead acid or gel type. Connect four (4) 12VDC batteries in series to terminals marked [+ BAT –] (Fig. 2h, pg. 4), carefully observing polarity.
Note: When batteries have not been used a loss of AC will result in a loss of output voltage.
2a OUT 1-8: Structured cable to PoE-compliant cameras/edge devices.
2b IN 1-8: Structured cable to an ethernet switch or video server.
2c LED(s) 1-8: Port status LEDs.
2d Reset: Restores unit to factory settings.
2e USB Port: For future use.
2f Ethernet: For future use.
2g IEC 320 Connector: 115/230VAC (grounded line cord included).
2h Built-in battery charger: Charges stand-by batteries for applications
requiring back-up, (optional rack mount battery enclosure available – RE2)
Technical Specifications:
Parameter | Description |
---|---|
No. of Ports | Eight (8) PoE/PoE+/Hi PoE Ports (10/100/1000 Mbps). |
Output Power | 240W total. |
Input Power Requirements | 115VAC, 60Hz, 3.25A or 230VAC, 50/60Hz, 2.0A. |
Indicators | Port Status LEDs. |
Environmental Conditions | Operating Ambient Temperature: 20°C to 40°C (— |
4°F to 104°F).
Relative Humidity:85%, +/— 5%.
Storage Temperature: 20°C to 70°C (— 4°F to 158°F).
Operating Altitude:304.8 to 3,048m.
The lightning flash with an arrowhead symbol within an equilateral triangle is
intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE
within the product’s enclosure that may be of sufficient magnitude to
constitute an electric shock.
The exclamation point within an equilateral triangle is intended to alert the
user to the presence of important operating and maintenance (servicing)
instructions in the literature accompanying the appliance.
CAUTION: To reduce the risk of electric shock do not open the enclosure.
There are no user-serviceable parts inside. Refer servicing to qualified
service personnel.
NetWayXT and NetWayXTX will work if the Midspan is set for 15W or 30W, but not 60W.
Installing a NetWayXT/NetWayXTX Repeater Module:
NetWayXT will work only with PoE devices. NetWayXTX will work with PoE/PoE+ devices.
-
Mount NetWayXT/NetWayXTX in the desired location utilizing the mounting hole (Fig. 3, pg. 5).
Use a proper fastener and/or wall anchor when securing NetWayXT/NetWayXTX to the wall. -
Connect the structured cable from port marked [OUT] on NetWay8GL to port marked [IN] on the NetWayXT/NetWayXTX (Fig. 3, pg. 5).
-
Connect structured cable from port marked [OUT] on NetWayXT/NetWayXTX to the PoE/PoE+ camera/edge devise or next NetWayXT/NetWayXTX repeater (Fig. 3, pg. 5).
-
Port status LEDs will illuminate on NetWayXT/NetWayXTX indicating the port is operational (refer to LED Definitions, pg. 5).
-
Power LED will illuminate indicating 12VDC output.
Port LED Definitions for NetWayXT and NetWayXTX Repeaters:
Status | NetWayXT | NetWayXTX |
---|---|---|
Green LED | Yellow LED | PoE/PoE+ Output LED |
Input LED | Yellow LED | |
OFF | Indicates it is connected as 10Base-T or no link. | Indicates no |
link. | No PoE/PoE+ Output | No PoE/PoE+ Input |
ON | Indicates it is connected as 1 00Base-TX. | Indicates a link. |
PoE/PoE+ Output | PoE/PoE+ Input | Indicates a link. |
Blinking | Indicates activity. |
NetWay8GL Typical Applications:
Configuring NetWay8GL for Network Connection
Please be sure to visit altronix.com for the latest firmware and
installation instructions
Factory Default Settings
- IP Address: 192.168.168.168
- User Name: admin
- Password: admin
-
Set the static IP address for the laptop to be used for programming to the same network IP address as the NetWay8GL. The default address of the NetWay8GL is 192.168.168.168, E.I. 192.168.168.200.
-
Connect one end of the network cable to the network jack on the NetWay8GL and the other to the network connection of the laptop.
-
Open a browser on the computer and enter “192.168.168.168” into the address bar. A dialog box Authentication Required will appear requesting both user name and password.
Enter the default values here. Click on the button labeled Log In. -
The status page of the NetWay8GL will appear. Click on the tab labeled Network Settings. This will open the Network Setting screen. In this screen, the MAC Address of the NetWay8GL module will be found along with the Network Settings and Email Settings.
Network Settings:
In the IP Address, the Method field selects the method that the IP Address for
the NetWay8GL that will be obtained (STATIC or DHCP), then follows the
appropriate steps.
Static:
a. IP Address: Enter the IP address assigned to the NetWay8GL by the network
administrator.
b. Subnet Mask: Enter the Subnet of the network.
c. Gateway: Enter the TCP/IP gateway of the network access point (router)
being used.
Gateway configuration is required to properly receive emails from the device.
d. HTTP Port: Enter the HTTP port number assigned to the NetWay8GL module by
the network administrator to allow remote access and monitoring. The default
inbound port setting is 80. HTTP is not encrypted and unsecure. Even though
HTTP can be used for remote access, it is recommended primarily for use with
LAN connections.
e. HTTPS Port: Enter the HTTPS port number assigned to the NetWay8GL module by
the network administrator to allow remote access and monitoring. The default
inbound port setting is 443.
Being encrypted and more secure, HTTPS is highly recommended for remote
access.
f. Click the button labeled Submit Network Settings. A dialog box will display
“New network settings will take effect after the server is rebooted”. Click
OK.
DHCP:
a. After selecting DHCP in the IP Address Method field click the button
labeled Submit Network Settings. A dialog box will display “New network
settings will take effect after the server is rebooted”. Click OK. Next, click
on the button labeled Reboot Server. After rebooting the NetWay8GL will be set
in the DHCP mode. The IP address will be assigned by the router when the
NetWay8GL is connected to the network. It is recommended to have the assigned
IP Address reserved to ensure continued access (see the network
administrator).
b. Subnet Mask: When operating in DHCP, the router will assign the subnet mask
values.
c. Gateway: Enter the TCP/IP gateway of the network access point (router)
being used.
d. HTTP Port: Enter the HTTP port number assigned to the NetWay8GL module by
the network administrator to allow remote access and monitoring. The default
inbound port setting is 80. HTTP is not encrypted and unsecure. Even though
HTTP can be used for remote access, it is recommended primarily for use with
LAN connections.
Secure Network Setup (HTTPS):
In order to set up HTTPS for a Secure Network Connection, a Valid Certificate
and Key must be used. Certificates and Keys should be in a “.PEM” format. Self
Certifications should only be used for testing purposes as no actual
authentication is being performed. In a Self-Certified mode, the connection
will still state that it is unsecure. How to upload the Certificate and Key to
setup HTTPS:
- Open the Tab Labeled “Security”
- Select the Tab Labeled “Email/SSL”
- Scroll to the bottom under “SSL Settings”
- Click “Select Certificate”
- Browse and select a valid Certificate to upload from the server
- Click “Select Key”
- Browse and select a valid Key to upload from the server
- Click “Submit Files”
Once the Certificate and Key are uploaded successfully you can proceed with
setting up HTTPS in Network Settings.
a. HTTPS Port: Enter the HTTPS port number assigned to the NetWay8GL module by
the network administrator to allow remote access and monitoring. The default
inbound port setting is 443.
Being encrypted and more secure, HTTPS is highly recommended for remote
access.
b. Click the button labeled Submit Network Settings.
A dialog box will display “New network settings will take effect after the
server is rebooted”. Click OK.
Heartbeat Timer:
The heartbeat timer will send a trap message indicating that the NetWay8GL is
still connected and communicating.
Setting the Heartbeat Timer:
- Click the button labeled Heartbeat Timer Setting.
- Select the desired time between heartbeat messaging in the Days, Hours, Minutes, and Seconds in the corresponding fields.
- Click the button labeled Submit to save the setting.
Mounting Options:
Rack Mount Installation
- Remove and discard factory-installed screws from both sides of the rack chassis (Fig. 5a).
- Install mounting brackets (A) on the left and right side of the rack chassis using the four (4) flat head screws (B) (included) (Fig. 5b).
- Place the unit into desired EIA 19” rack position and secure it with mounting screws (not included) (Fig. 5c).
Wall Mount Installation
- Install mounting brackets (A) on the left and right side of the rack chassis using four (4) flat head screws (B) (included) (Fig. 6a).
- Place the unit at the desired location and secure it with #6 size screws or larger (not included) (Fig. 6b).
Caution: It is necessary to make sure mounting screws are securely fastened to a beam when installing the unit vertically.
Shelf Installation
- Position and affix rubber pads (C) (included) at each corner on the bottom of the unit (Fig. 7).
- Place the unit in the desired location.
Mounting Hardware (Included):
| A. Two (2) mounting brackets
---|---
| B. Six (6) flat head screws for mounting brackets.
| C. Four (4) rubber pads.
Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA
718-567-8181
fax:718-567-9056
website:www.altronix.com
e-mail:info@altronix.com
Lifetime Warranty
IINetWay8GL
H24U NetWay8GL Installation Guide
Documents / Resources
|
Altronix NetWay8GL Network Managed PoE
Midspan
[pdf] Installation Guide
NetWay8GL, Network Managed PoE Midspan, Managed PoE Midspan, Network PoE
Midspan, PoE Midspan, Midspan
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>