Trotec B24E humidifier portable Air purifier Instruction Manual

June 5, 2024
TROTEC

OPERATING MANUAL
HUMIDIFIER

B24E/B25E

Notes regarding the operating manual ****

Symbols
Warning of electrical voltage
This symbol indicates dangers to the life and health of persons due to electrical voltage.
Warning
This signal word indicates a hazard with an average risk level which, if not avoided, can result in serious injury or death.
Caution
This signal word indicates a hazard with a low risk level which, if not avoided, can result in minor or moderate injury.
NoteThis signal word indicates important information (e.g. material damage), but does not indicate hazards.
Info
Information marked with this symbol helps you to carry out your tasks quickly and safely.
Follow the manual
Information marked with this symbol indicates that the operating manual must be observed.
You can download the current version of the operating manual and the EU declaration of conformity via the following link:

B 24
**** https://hub.trotec.com/?id=42337

B 25 Ehttps://hub.trotec.com/?id=42339

Safety

Read this manual carefully before starting or using the device. Always store the manual in the immediate vicinity of the device or its site of use.

Warning
Read all safety warnings and all instructions. Failure to follow the warnings and instructions may result in electric shock, fire, and/or serious injury. Save all warnings and instructions for future reference.
This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance.  leaning and user maintenance shall not be made by children without supervision.

  • Do not use the device in potentially explosive rooms or areas and do not install it there.
  • Do not use the device in aggressive
  • Only put up the device in an upright, stable position on a firm.
  • Do not expose the device to directly squirting.
  • Fill the device with clear drinking water.
  • Never insert any objects or limbs into the devaic.
  • Do not cover the device during
  • Do not sit on the devaic.
  • This appliance is not a Keep away from children and animals. Do not leave the device unattended during operation.
  • Ensure that all electric cables outside of the device are protected from damage (e.g. caused by animals). Never use the device if electric cables or the power connection are damaged!
  • The mains connection must correspond to the specifications in the Technical
  • Insert the mains plug into a properly fused mains
  • Observe the device’s power input, cable length and intended use when selecting extensions to the power Completely unroll extension cables. Avoid electrical overload.
  • Before carrying out maintenance, care or repair work on the device, remove the mains plug from the mains Hold onto the mains plug while doing so.
  • Switch the device off and disconnect the power cable from the mains socket when the device is not in
  • Do not under any circumstances use the device if you detect damages on the mains plug or power
  • If the power cable is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. Defective power cables pose a serious health risk!
  • Make sure that the air inlet and outlet are not obstructed.
  • Make sure that the suction side is kept free of dirt and lose objects
  • Do not remove any safety signs, stickers or labels from the Keep all safety signs, stickers and labels in legible condition.
  • Do not use the device when the water tank is
  • Before filling the water tank, switch the device off and disconnect the power cable from the mains Hold onto the mains plug while doing so.
  • Only transport the device in an upright position with an emptied water
  • Empty and clean the water tank prior to storage or Do not drink the water. Health hazard!
  • Note that high humidity levels may enhance the growth of biological organisms in the
  • Make sure that objects in the surroundings of the device do not become wet or If moisture is present, the output must be reduced. Set the device to a lower level. If the output cannot be reduced, the device must only be operated in intervals. If necessary, switch the device off completely for a short time. Absorbent materials such as carpeting, curtains, sheers or tablecloths must not become damp.
  • Make sure that the water in the water tank is replaced every 3 days. Otherwise, there is a risk of microorganisms growing in the water tank which presents a health hazard if they get into the air or water.

Intended use

Only use the device as a mobile humidifier for the humidification and filtration of room air, while adhering to and following the technical data. Intended use comprises humidifying the room air in:

  • living spaces
  • warehouses and archives
  • libraries
  • call centers and computer rooms

Foreseeable misuse
The device is not intended for industrial use.

  • Do not place the device on wet or flooded
  • Do not place any objects, g. clothing, on the device.
  • Do not use the device out of
  • Do not make any unauthorized modifications, alterations or structural changes to the devaic.
  • Any use other than the intended use is regarded as a reasonably foreseeable misuse.

Personnel qualifications

People who use this device must:

  • be aware of the dangers that occur when working with electric devices in damp areas.
  • have read and understood the operating manual, especially the Safety chapter.

Residual risks

Warning of electrical voltage
Work on the electrical components must only be carried out by an authorized specialist company!
Warning of electrical voltage
Before any work on the device, remove the main plug from the main socket!
Do not touch the mains plug with wet or damp hands. Hold onto the mains plug while pulling the power cable out of the mains socket.
Warning
Dangers can occur at the device when it is used by untrained people in an unprofessional or improper way! Observe the personnel qualifications!
Warning
The device is not a toy and does not belong in the hands of children.
Warning
Risk of suffocation!
Do not leave the packaging lying around. Children may use it as a dangerous toy.
Caution
If the device is knocked over, water will leak from the lower part.
Disconnect the device from the mains to prevent damage to the device caused by dry running.
Note
Do not operate the device without an inserted evaporation filter!
Without an evaporation filter, the inside of the device will be heavily contaminated. This could reduce the performance and result in damage to the device.

Behavior in the event of an emergency

  1. Switch the device
  2. In an emergency, disconnect the device from the mains feed-in: Hold onto the mains plug while pulling the power cable out of the mains
  3. Do not reconnect a defective device to the mains

Information about the device

Device description

The device functions as a humidifier, aroma diffuser, and air cleaner.
The hygrostat-controlled room air humidification by natural cold evaporation ensures a pleasant room climate and air quality improvement.
The device is equipped with an integrated scented oil tank and diffuser for optional room air aromatization.
An evaporation filter with a special honeycomb structure ensures an optimum humidity level of 40 % to 60 %. The filter further prevents lime and other air pollutants from being emitted into the room air.
As an additional equipment option, a SecoSan® ion reservoir keeps the water demonstrably free from germs. The device comes with different operating modes as well as a night mode enabling ultra-silent operation at bedtime. The device switches off automatically when the water tank is empty.

The functioning of the two devices B 24 E and B 25 E is identical, they merely differ in appearance or to be precise in color: The device B 24 E is copper- colored and the device B 25 E is white.

Device depiction

Trotec B24E humidifier portable Air purifier - fig

No. Designation
1 Attachment of air filter grid
2 Power cable
3 Upper part with electronic equipment and fan
4 SecoSan® Stick 10
5 Water tank with a retainer for evaporation filter, SecoSan® Stick 10
6 Evaporation filter
7 Controls

Transport and storage

Note
If you store or transport the device improperly, the device may be damaged. Note the information regarding the transport and storage of the device.

Transport
Before transporting the device, observe the following:

  • Switch the device

  • Hold onto the mains plug while pulling the power cable out of the mains

  • Empty the water tank.

  • Do not use the power cable to drag the

  • Check whether the upper part is correctly positioned on the lower

  • Lift the device to the lower
    After transporting the device, proceed as follows:

  • Set up the device in an upright position after transport

Storage
Before storing the device, proceed as follows:

  • Hold onto the mains plug while pulling the power cable out of the mains
  • Empty and clean the water tank prior to storage (see chapter Maintenance).
  • Use a cloth to wipe all parts of the device

When the device is not being used, observe the following storage conditions:

  • dry and protected from frost and heat
  • in an upright position where it is protected from dust and direct sunlight
  • with a cover to protect it from invasive dust, if necessary
  • Place no further devices or objects on top of the device to prevent it from being damaged.

Assembly and installation

Scope of delivery

  • 1 x Device
  • 1 x Adapter
  • 1 x Evaporation filter
  • 1 x SecoSan® Stick 10
  • 1 x Manual

Unpacking the device

  1. Open the cardboard box and take the device
  2. Completely remove the
  3. Fully unwind the power Make sure that the power cable is not damaged and that you do not damage it during unwinding.

Start-up

  • Before restarting the device, check the condition of the power If there are doubts as to the sound condition, contact the customer service.
  • Only put up the device in an upright, stable position on a firm.
  • Do not create tripping hazards when laying the power cable or other electric cables, especially when positioning the device in the middle of the Use cable bridges.
  • Make sure that extension cables are completely
  • Do not set up the humidifier next to furniture, paintings, and other devices which can be damaged by

Filling the water tank
**** Info If possible, change the water every 3 days to prevent bacterial growth.

  1. Remove the upper part from the water tank and put it asid.
    Trotec B24E humidifier portable Air purifier - fig 8

  2. Insert the SecoSan® Stick 10 into the provided retainer on the bottom of the water tank.

  3. Insert the evaporation filter into the water tank.

  4. Fill the water tank with fresh drinking
    The device is ready for operationStop 5 cm below the edge of the water tank.
    The evaporation filter may get

  5. Place the upper part correctly onto the water
    The electronic equipment and the fan in the upper part must not get

  6. When setting up the device, ensure a sufficient distance to walls and other objects. The air inlet and outlet must not be obstructed or covered, e.g. by curtains.

  7. Plug the mains plug into a sufficiently fused socket.
    The device is ready for operation

Scent option
Additionally, the device offers the possibility to distribute a scent during operation.
Use standard scented oil. Proceed as follows to use the scent option:
The device is switched off and the power cable is disconnected from the devaic.

  1. Unscrew the attachment for the air grid (1) by turning counter-clockwise.

  2. Remove the air
    The scented oil reservoir is open.

  3. Rinse the filter ring (16) under running water if you use different scented oils in succession.

  4. Add a few drops of scented oil onto the filter ring (16) in the scented oil reservoir.
    Note Make sure that no scented oil drops onto the fan or the electronic equipment below as this may damage the device.

  5. Put the air grid back on the device and fasten the attachment by turning

Connecting the power adapter

  • Plug the power adapter cable into the device’s mains
  • Plug the power adapter into a properly fused mains

Operation

  • Avoid open doors and

Operating elements

No. Designation Meaning
8 Filter LED Filter change indication
9 Dimmer button Dimming the LEDs
10 Hygrostat button Selection button for the humidity level 45 %, 50 %, 55

%, 60 %,
100 % (continuous operation)
11| No water LED| Refill water tank indication
12| Humidity level LEDs| Indication of the set room humidity level
13| Power button| Switching the device on or off
14| Speed button| Setting the fan speed
15| Fan speed LEDs| Fan speed indication
1| Stage 1 = low (night mode)
2| Stage 2 = medium
3| Stage 3 = high
4| Stage 4 = maximum

Switching the device on

  1. Make sure that the tank has been filled with
  2. Make sure that the device is neither damp nor wet on the Otherwise wipe it dry.
  3. Press the Power button (13).
    The blue LEDs light up

Note
If the set humidity level is already present in the room, the blue Humidity level LED (12) will flash for approx. 5 seconds. Then motor and fan will switch off.

Setting the fan stage

  1. Press the Speed button (14) until the LED (15) for the desired stage is
    Stage 1: very quiet, during sleep or for night
    Stage 2: quiet, for bedrooms or smaller
    Stage 3: for operation during the day in rooms of up to 25 m2.
    Stage 4: maximum speed, for fast humidification or very dry room air.

Controlling humidification
The desired room humidity can be set to 45 %, 50 %, 55 %, 60 % or 100 % (continuous operation – continuous humidification regardless of the humidity level in the room). The device automatically measures the room humidity level and stops humidification when the set level is reached. If this humidity level is fallen below again, the device restarts.

  1. Press the Hygrostat button (10) to set the desired humidity
    The corresponding Humidity level LED (12) will be illuminated.

Dimming the LEDs
You can reduce the luminous intensity of the LEDs, e.g. if you want to operate the device in a bedroom at night. Adjust the luminous intensity as follows:

  1. Press the Dimmer button (9) until the desired brightness level for the LEDs is set.
    You can choose between full and medium illumination, or switch the LEDs off.

Shutdown

Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.

  • Switch off the device by pressing the Power button (13).
  • Hold onto the mains plug while pulling the power cable out of the mains
  • Empty the water tank.
  • Use a cloth to wipe all parts of the device
  • Clean the device according to the Maintenance
  • Store the device according to the Transport and storage chapter.

Available accessories

Warning
Only use accessories and additional equipment specified in the operating manual Using insertion tools or accessories other than those specified in the operating manual may cause a risk of injury.

Designation Article number
Evaporation filter B 24 E / B 25 E 7.710.000.832
SecoSan® Stick 10 6.100.004.110

Errors and faults

The device has been checked for proper functioning several times during production. If malfunctions occur nonetheless, check the device according to the following list.
The device does not start:

  • Check the power
  • Check the power cable and mains plug for
  • Check the on-site
  • Check whether the water tank indicator light is The water tank might be empty and need refilling.
  • Check the setting of the desired room humidity If it is below the current humidity level, the device will not start.
  • Wait for 10 minutes before restarting the device. If the device is not starting, have the electrics checked by a specialist company or by Trotec.

The device runs, but there is no humidification:

  • Check the fan for proper functioning or unusual vibrations and sounds. Remove external dirt

Water is leaking:

  • Check whether the device is set up in a stable and upright
  • Check the water level in the water tank. The water level might be too high and water is discharged via the overflow.
  • Check the device for leaks

The device gives off an unpleasant odor:

  • The device is removed and rinse the water tank. Let the open water tank air for some hours.
  • Check the water tank. There may be stale or dirty water in the water tank. Rinse the water tank and fill it with fresh drinking water.

The device gets very warm, is loud, or is losing performance:

  • Check the air inlets and air grilles to Remove external dirt.
  • Check the inside of the device for dirt (see chapter Maintenance). If necessary, clean the interior of the device using compressed air.

The device is loud or vibrates heavily:

  • Check whether the device is set up in a stable and upright

The device still does not operate correctly after these checks: Please contact customer service. If necessary, bring the device to an authorized specialist electrical company or to Trotec for repair.

Maintenance

Maintenance and care interval| before every start-up| as needed| every 3 days| at least every 2 weeks| at least every
weeks
| at least every 6 months| at least annually
---|---|---|---|---|---|---|---
Cleaning the water tank| | | X| | | |
Check air inlets and outlets for dirt and foreign objects and clean if necessary| X| | | | X| |
Clean the exterior| | X| | | | | X
Visually check the inside of the device for dirt| | X| | | | | X
Check the air filter for dirt and foreign objects and clean or replace if necessary| X| | | X| | |
Replace the air filter| | | | | | X|
Check for damage| X| | | | | |
Check the attachment screws| | X| | | | | X
Test run| | | | | | | X

Maintenance and care log
Device type: ………………………………………                              Device number: ………………………………

Maintenance and care interval| 1| 2| 3| 4| 5| 6| 7| 8| 9| 10| 11| 12| 13| 14| 15| 16
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---
Cleaning the water tank| | | | | | | | | | | | | | | |
Check air inlets and outlets for dirt and foreign objects and clean if necessary| | | | | | | | | | | | | | | |
Clean the exterior| | | | | | | | | | | | | | | |
Visually check the inside of the device for dirt| | | | | | | | | | | | | | | |
Check the air filter for dirt and foreign objects and clean or replace if necessary| | | | | | | | | | | | | | | |
Replace the air filter| | | | | | | | | | | | | | | |
Check for damage| | | | | | | | | | | | | | | |
Check the attachment screws| | | | | | | | | | | | | | | |
Test run| | | | | | | | | | | | | | | |
1. Date:  ……………………………..
Signature: …………………………..| 2. Date:  ………………………………
Signature: ……………………………| 3. Date:  ………………………………
Signature: ……………………………| 4. Date: ………………………………
Signature: ……………………………
---|---|---|---
5. Date:  ……………………………..
Signature: …………………………..| 6. Date:  ………………………………

Signature: ……………………………

| 7. Date:  ………………………………

Signature: ……………………………

| 8. Date: ………………………………
Signature: ……………………………
9. Date:  ……………………………..
Signature: …………………………..| 10. Date:  …………………………….
Signature: ……………………………| 11. Date:  …………………………….

Signature: ……………………………

| 12. Date:  …………………………….
Signature: ……………………………
13. Date:  ……………………………
Signature: …………………………..| 14. Date:  …………………………….

Signature: ……………………………

| 15. Date:  …………………………….
Signature: ……………………………| 16. Date:  …………………………….
Signature: ……………………………

Activities required before starting maintenance

Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.

  • Switch the device
  • Hold onto the mains plug while pulling the power cable out of the mains

Warning of electrical voltage
Tasks that require the device to be opened must only be carried out by authorized specialist companies or by Trotec.

Cleaning the housing

Clean the housing with a soft, damp, and lint-free cloth. Make sure that no moisture enters the housing. Protect electrical components from moisture. Do not use any aggressive cleaning agents such as cleaning sprays, solvents, or alcohol-based or abrasive cleaners to dampen the cloth.

Cleaning the water tank

**** Info
Use the SecoSan® Stick by Trotec to provide protection from germs in the water. The SecoSan® Stick prevents the reproduction of germs by means of silver ions. Due to the special, antimicrobial surface, the silver ions are emitted to the immediate proximity of bacteria and germs. This way, microbial growth can be effectively prevented – at the same time, the water remains pure and uncontaminated. The dosage of the SecoSan ® Stick is carried out automatically

Info
Clean the nebulizer membrane, air outlet, water tank and the water lines as often as possible. The water tank should be cleaned every 3 days if actively used. Use household vinegar as a cleaning/descaling agent. Observe the manufacturer’s specifications and hazard warnings of the descaling agent. Before a longer period of non-use or storage the water tank should be drained.

  1. Remove the upper part from the water tank and put it aside.
    Trotec B24E humidifier portable Air purifier - fig 8

  2. Take the evaporation filter out of the water tank.

  3. Thoroughly rinse the water tank in a sink or email.

  4. Wipe the water tank dry.

  5. Reinsert the evaporation filter into the water tank.

  6. Fill the water tank with fresh drinking water if you want to continue
    Stop 5 cm below the edge of the water tank.
    The evaporation filter may get

  7. Place the upper part correctly onto the water tank
    The electronic equipment and the fan in the upper part must not get wet.

Replacing the evaporation filter
The Filter LED (8) is permanently illuminated in blue. After 800 operating hours, the LED starts flashing. In this case, the evaporation filter should be replaced.

The device is switched off and the power cable is disconnected from the mains.
The Filter LED (8) flashes.

  1. Remove the upper part from the water tank and put it aside.
    Trotec B24E humidifier portable Air purifier - fig1

  2. Open the Velcro® fastener at the evaporation filter.

  3. Remove the evaporation filter from the filter frame.

  4. Dispose of the used evaporation filter according to the national regulation .

  5. Attach the new evaporation filter to the filter frame and reinsert the evaporation filter.

  6. Place the upper part correctly onto the water
    The electronic equipment and the fan in the upper part must not get

  7. Reconnect the device and switch it

  8. Press the Dimmer button (9) for 3 to 5 s to carry out a filter reset.
    The Filter LED (8) stops flashing and is permanently illuminated

Activities required after maintenance
If you want to continue using the device:

  • Reconnect the device to these devices:

If you do not intend to use the device for a considerable time:

  • Store the device according to the Transport and storage chapter

Technical annex

Technical data

Parameter Value
Model B 24 E / B 25 E
Max. evaporation performance 8.4 l / 24 h
Runtime 8 h
Max. power input 6 W
Mains connection (adapter) 1/N ~ 240 V 50 Hz / 60 Hz
The output voltage of an adapter 12 V
The output current of adapter 0.4 A
Nominal current consumption 0.2 A
Supply voltage 12 V
Sound pressure level (at a distance of 1 m) 58 dB(A)
Water tank capacity 3 l
Dimensions (width x height x length) 248 x 248 x 305 mm
Weight 2.5 kg

Disposal

**** The icon with the crossed-out waste bin on waste electrical or electronic equipment stipulates that this equipment must not be disposed of with the household waste at the end of its life. You will find collection points for free return of waste electrical and electronic equipment in your vicinity. The addresses can be obtained from your municipality or local administration. You can also find out about other return options that apply to many EU countries on the website https://hub.trotec.com/?id=45090. Otherwise, please contact an official recycling centre for electronic and electrical equipment authorized for your country.
The separate collection of waste electrical and electronic equipment aims to enable the re-use, recycling and other forms of recovery of waste equipment as well as to prevent negative effects for the environment and human health caused by the disposal of hazardous substances potentially contained in the equipment.

Trotec GmbH
Grebbener Str. 7 D-52525 Heinsberg
+49 2452 962-400
+49 2452 962-200
info@trotec.com www.trotec.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals