TROTEC TTR 500 D Desiccant Dehumidifier Instructions
- June 5, 2024
- TROTEC
Table of Contents
TROTEC TTR 500 D Desiccant Dehumidifier
Symbols
-
Warning of electrical voltage
This symbol indicates dangers to the life and health of persons due to electrical voltage. -
Warning of hot surface
This symbol indicates dangers to the life and health of persons due to hot surface. -
Warning
This signal word indicates a hazard with an average risk level which, if not avoided, can result in serious injury or death. -
Caution
This signal word indicates a hazard with a low risk level which, if not avoided, can result in minor or moderate injury. -
Note
This signal word indicates important information (e.g. material damage), but does not indicate hazards. -
Info
Information marked with this symbol helps you to carry out your tasks quickly and safely. -
Follow the manual
Information marked with this symbol indicates that the instructions must be observed.
Safety
Read this manual carefully before starting or using the device. Always store the manual in the immediate vicinity of the device or its site of use.
-
Warning
Read all safety warnings and all instructions. Failure to follow the warnings and instructions may result in electric shock, fire and/or serious injury. Save all warnings and instructions for future reference. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. -
Warning
Children of less than 3 years should be kept away unless continuously supervised. Children aged from 3 years and less than 8 years shall only switch on/off the appliance provided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
Children aged from 3 years and less than 8 years shall not plug in, regulate and clean the appliance or perform user maintenance. -
Warning
This device is not equipped with a room temperature controller. Do not use the device in small rooms if persons are present who cannot leave the room independently and who are not under constant supervision. -
Do not use the device in potentially explosive rooms or areas and do not install it there.
-
Do not use the device in aggressive atmosphere.
-
Only put up the device in an upright, stable position on firm ground.
-
Let the device dry out after a wet clean. Do not operate it when wet.
-
Do not use the device with wet or damp hands.
-
Do not expose the device to directly squirting water.
-
Ensure sufficient lighting at the device.
-
Never insert any objects or limbs into the running device.
-
Do not cover or transport the device during operation.
-
Do not sit on the device.
-
This appliance is not a toy! Keep away from children and animals. Do not leave the device unattended during operation.
-
Check accessories and connection parts for possible damage prior to every use of the device. Do not use any defective devices or device parts.
-
Ensure that all electric cables outside of the device are protected from damage (e.g. caused by animals). Never use the device if electric cables or the power connection are damaged!
-
The electrical connection must correspond to the specifications on the nameplate. Additionally, information regarding the electrical connection is provided in the technical annex.
-
Insert the mains plug (if any) into a properly secured mains power socket.
-
Observe the device’s power input, cable length and intended use when selecting extensions to the power cable. Completely unroll extension cables. Avoid electrical overload.
-
If you do not use the device for extended periods of time, switch the device off and disconnect it from the mains.
-
Before maintenance, care or repair work disconnect the device from the mains and secure it against unauthorized restart.
-
Before carrying out maintenance, care or repair work on the device, remove the mains plug from the mains socket. Hold onto the mains plug while doing so.
-
Do not under any circumstances use the device if you detect damages on the mains plug or power cable.
-
If the power cable is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
-
Defective power cables pose a serious health risk!
-
When positioning the device, observe the minimum distances from walls and other objects as well as the storage and operating conditions specified in the technical annex.
-
Make sure that the air inlet and outlet are not obstructed.
-
Make sure that the suction side is kept free of dirt and loose objects.
-
Do not use the device in immediate proximity to curtains, beds or sofas.
-
Do not place the device on combustible ground.
-
Do not remove any safety signs, stickers or labels from the device. Keep all safety signs, stickers and labels in legible condition.
-
Do not use this device near bathtubs, shower trays, swimming pools or other water containers. Risk of electric shock!
-
Allow the device to cool down before transport and/or maintenance work.
-
Only transport the device in an upright position.
-
Do not use the device any more once it has been dropped.
-
The device must not be positioned directly beneath a wall socket.
Intended use
The desiccant dehumidifiers of the TTR series are only to be used for
dehumidifying atmospheric air. Any other use possibly exceeding the intended
purpose is considered to be improper use.
Intended use comprises:
- observing all the information in the instructions
- compliance with the inspection and maintenance tasks
- observing the permissible operating and surrounding conditions according to the technical data (see Technical annex)
The following minimum requirements must be met:
- permissible ambient temperature: -20 °C to +40 °C
- relative humidity: max. 95 % non-condensing
After consultation with Trotec other operating conditions are possible with respectively modified versions.
Improper use
- Dehumidifiers are not suited for the installation on or the intake of fluids, e.g. from filled tanks, tubs or flooded installation areas.
- If supplying the system with contaminated air, the “harmful influences on rotors” must be observed!
- Any unauthorised modifications, alterations or structural changes to the device are forbidden.
- Any other use than the one described in the chapter “Intended use” is regarded as reasonably foreseeable misuse.
Symbols on the device
- Meaning
This symbol located on the device indicates that it is prohibited to place objects (such as towels, clothes etc.) above or directly in front of the device.
In order to avoid overheating and fire hazards, the device must not be covered!
Personnel qualifications
People who use this device must:
- be aware of the dangers that occur when working with electric devices in damp areas.
- have read and understood the instructions, especially the Safety chapter.
Instructed person
Instructed persons have been informed of the tasks they were entrusted with as
well as of potential hazards resulting from inappropriate behaviour. They are
allowed to operate and transport the device and perform simple maintenance
activities (cleaning the housing, cleaning the fan).
The device is to be maintained and looked after by instructed personnel.
Residual risks
-
Warning of electrical voltage
Work on the electrical components must only be carried out by a qualified electrician! -
Warning of electrical voltage
Make sure to de-energize the device before starting work on electrical components.
Hold onto the mains plug while pulling the power cable out of the mains socket. -
Warning of hot surface
Some parts of this product can become very hot and cause burns. Particular attention has to be given where children and vulnerable people are present! -
Warning
Dangers can occur at the device when it is used by untrained people in an unprofessional or improper way!Observe the personnel qualifications! -
Warning
The device is not a toy and does not belong in the hands of children. -
Warning
Risk of suffocation!
Do not leave the packaging lying around. Children may use it as a dangerous toy. -
Warning
In order to avoid overheating and fire hazards, the device must not be covered! -
Note
Do not operate the device without an air filter inserted into the air inlet!
Without the air filter, the inside of the device will be heavily contaminated. This could reduce the performance and result in damage to the device. -
Note
Dirt accumulating inside the rotor can substantially reduce the dehumidification performance or damage the rotor beyond repair.
Supplying the system with contaminated air might damage the rotor. Observe the information regarding “Harmful influences on rotors”. -
Note
After a power failure the device will restart automatically provided that it was not switched off in the meantime. This behaviour is desired and necessary to ensure operation with little supervision.
Behaviour in the event of an emergency
- Switch off the device.
- In an emergency, disconnect the device from the mains feed-in: Hold onto the mains plug while pulling the power cable out of the mains socket.
- Do not reconnect a defective device to the mains.
Information about the device
General description
Dehumidifiers operating on the desiccant principle are used to tackle drying
tasks in the field of process engineering,
air-conditioning, on construction sites and for the dehumidification of
production and storage facilities, where a particularly low humidity level is
required over a broad temperature range.
The desiccation technique enables the safe and economic operation even at low
operating temperatures.
The desiccant dehumidifier works with a desiccant wheel
(rotor), which is composed of layers of smooth and corrugated non-woven fabric
with chemically bonded silica gel. Thus created is a honeycomb structure with
a large number of axial air ducts with a large surface and direct connection
to the inner pore structure of the silica gel.
On account of the desiccant wheel’s good mechanical and physical properties no
silica gel is discharged. It may be supplied with saturated air with a
relative humidity of up to 100 % but not with water drops. The rotor is
incombustible.
Design
The general structure of a dehumidification unit is as follows:
- fans for air transport
- at least two different sectors for guiding the process air (to be dehumidified) and the regeneration air (moist exhaust air)
- rotor desiccant wheel for the dehumidification with silica gel
- drive unit with gear motor, toothed belt pulley and toothed belt
- heater battery for heating regeneration air
During dehumidification the desiccant wheel turns continuously at a low speed (depending on the configuration 3 to 30 rotations per hour). Via the sectors the desiccant wheel is simultaneously charged with the process and regeneration air so it can constantly absorb and release moisture.
Functional principle TTR 400
Process air
The air to be dehumidified is sucked in by means of a fan and divided into two
air flows: process air (4) and regeneration
air (5).
The process air (4) flows through the desiccant wheel’s dehumidification
sector (1). In doing so, the contained moisture is withdrawn by the sorbent
(silica gel) and retained
(desiccation).
After having passed the sector, the now dried air (6) is emitted to the
room.
Regeneration air
The second air current (5) is guided through the purging sector as
regeneration air. This sector serves for the recovery of the desiccation heat
generated during dehumidification.
At the same time the desiccant wheel is cooled leading to a reduced energy
input and improved dehumidification performance – especially at lower dew
points.
Subsequently, the air current is led through a heater battery (7) and heated
to approx. 100 to 120 °C (depending on the intake temperature).
Simultaneously, the relative humidity is extremely reduced.
In passing through the regeneration sector (2), the thus prepared air now
again absorbs the moisture retained by the silica gel (desorption). Then the
extremely humid regeneration air (8) is discharged to the outside via the
humid air outlet.
Functional principle TTR 400 D / TTR 500 D
Process air
The air to be dehumidified is sucked in by means of a fan. The process air (4)
flows through the desiccant wheel’s dehumidification sector (1).
In doing so, the contained moisture is withdrawn by the sorbent (silica gel)
and retained (desiccation). Due to physical processes the temperature of the
dry air (6) increases. Later the dried air flows towards the dry air outlet.
Regeneration air
The regeneration air (5) is also sucked in with its own fan and guided through
the purging sector (3). During dehumidification the desiccant wheel warms up
as a result of the released desiccation heat and the regeneration heat. The
purging sector (3) serves the purpose of heat recovery and for cooling the
desiccant wheel, leading to a reduced energy input and improvement of the
dehumidification performance – especially at lower dew points. Whilst flowing
through the heater
battery (7) the air is heated to approx. 100 °C to 120 °C
(depending on the intake temperature) and at the same time the relative
humidity is extremely reduced.
In passing through the regeneration sector (2), the thusly prepared air now
again absorbs the moisture retained by the silica gel (desorption). Then the
extremely humid regeneration air (8) is discharged to the outside via the
humid air outlet.
Device depiction
- Designation
- Carrying handle
- Dry air outlet
- Feet
- Operating element
- Connection cable
- Air inlet grid with coarse particulate air filter
- Humid air outlet
- Air inlet grid with coarse particulate air filter
Optional accessories
Further accessories are available for operating the dehumidifier:
- Hose adapter to be assembled to the air inlet grid (16)
- Air filter box with pipe/hose connection for Z-line filters G4 to F9
- Hygrostat with Tuchel plug for connection socket (20)
- Combined counter for operating hours and energy consumption
For more information on features and order conditions please contact the Trotec customer service.
Transport and installation
To make the device easier to transport, it is fitted with a carrying handle.
-
Note
If you store or transport the device improperly, the device may be damaged.
Note the information regarding transport and storage of the device. -
Note
Device may be damaged by vibration!
Excessive vibrations can result in damage to the device.
Therefore, protect it against excessive vibrations, e.g. abrupt positioning or dropping, during transport. Always protect the device from slipping during transport.
Only lift or carry the device at the provided fixtures.
Positioning
-
Inside the room to be dehumidified:
- The device works in recirculation mode, the regeneration air must be fed from outside and the regeneration exhaust air must be led outside.
-
Outside the room to be dehumidified:
- The device can be connected in either recirculation or ventilation mode. A connection of the dry air to the room to be dehumidified must be established.
-
Storage
When the device is not being used, observe the following storage conditions:- dry and protected from frost and heat
- in an upright position where it is protected from dust and direct sunlight
- with a cover to protect it from invasive dust, if necessary
- When not in use, always disconnect the device from the power supply.
- Up to 4 devices may be stacked on top of one another to save space.
- Secure stacks against toppling over.
Assembly and installation
- The pipes or hoses used must be designed for the available static compression of the fans. The air hoses should preferably be laid in a straight line and at full length.
- The regeneration exhaust air line must be laid with a slight decline so that possibly accumulating condensate cannot flow back into the device or obstruct the air flow. If an incline cannot be avoided, it is necessary to establish a condensate drain. As preventive action, the exhaust air pipe may be insulated.
- To prevent an immediate neutralization with the moist exhaust air, the humid air outlet should be guided away with a minimum distance of approx. 1 m in case of direct-intake devices.
Scope of delivery
The scope of delivery of the device contains:
- 1 x Dehumidifier
- 1 x Connection cable
- 1 x Instructions
There are further accessories optionally available, which can be obtained from the Trotec customer service.
Default settings
Generally, air conditioning units are equipped with one or more fans, which
must be overdimensioned accordingly to overcome resistances caused by pipes or
appliances. Usually, their speed cannot be adjusted. In order to set the air
quantities required for the application, a hydraulic compensation must be
carried out by means of throttle valves installed in front of or behind the
fan. This, however, results in an unnecessary and often considerable increase
in the noise level and energy consumption.
This device has one integrated variable-speed high-performance fan for each
air current supplying the nominal volumetric flow rates of the dry air and
regeneration air at maximum speed despite the air hoses (approx. 10 m length
each) being connected.
Moreover, for heating the regeneration air, the device has an installed heater
battery generating heat by means of ceramic PTC semiconductor elements. The
latter have a maximum surface temperature of approx. 240 °C, which they try to
maintain. The temperature-dependent resistance, which rises rapidly as of a
certain value (Curie temperature) when the heat reduction decreases, causes
self-regulating effects of the heating current consumption, i.e. when the air
temperature rises and/or the air volume decreases, the current consumption is
reduced (and vice versa). Furthermore, a destruction caused by overheating,
for instance due to a lack of regeneration air, can be virtually ruled out.
In order to reach a preferably low outlet humidity level with a minimum dry
air volume or to achieve the highest dehumidification performance with a
maximum dry air volume, it is important to set the regeneration air volume
correctly. The air volume must be adjusted until the value specified as
optimum heating current is indicated on the ammeter.
For all other applications with low requirements regarding the
dehumidification performance and dry air volume, the fan speed may be
decreased until the value specified as minimum heating current is indicated on
the ammeter. This allows you to achieve very good dehumidification results at
minimum energy input.
Operation
Operating element
No. | Designation |
---|---|
9 | Carrying handle |
10 | Dry air outlet |
11 | Feet |
12 | Operating element |
13 | Connection cable |
14 | Air inlet grid with coarse particulate air filter |
15 | Humid air outlet |
16 | Air inlet grid with coarse particulate air filter |
Switch-on
Switch the device on by actuating the mains switch (17).
The integrated indicator light lights up.
Switch-off
Switch the device off by actuating the mains switch (17).
The integrated indicator light goes off.
Remote operation
Switch the device on by actuating the mains switch (17).
The integrated indicator light lights up.
Connect an external switch or external switching device,
e.g. a hygrostat or timer, to the socket (20) with the suitable Tuchel plug
(optional accessory). Always observe the information contained in the circuit
diagram (see Technical annex).
All electrical loads are now switched on or off by the external switch as
needed. The indicator light of the mains switch remains illuminated regardless
of the switching state and indicates that the control unit is activate. In
hygrostat operation, air circulation may in some cases be necessary at the
point of moisture measurement. In this case, the fan can be configured for
permanent operation by replugging a plug contact at the integrated relay. This
operation may only be carried out by an electrically skilled person. If
required, please contact the Trotec customer service.
Adjusting the air volume
Using the speed controllers (18) and (19) you can adjust the speed of the
fans.
- In order to increase the air volume, turn the speed controller to the right.
- In order to decrease the air volume, turn the speed controller to the left.
Optional accessories
Further accessories are available for operating the dehumidifier:
- Hose adapter to be assembled to the air inlet grid (16)
- Air filter box with pipe/hose connection for Z-line filters G4 to F9
- Hygrostat with Tuchel plug for connection socket (20)
- Combined counter for operating hours and energy consumption
For more information on features and order conditions please contact the Trotec customer service.
Transport and installation
To make the device easier to transport, it is fitted with a carrying handle.
-
Note
If you store or transport the device improperly, the device may be damaged.
Note the information regarding transport and storage of the device. -
Note
Device may be damaged by vibration!
Excessive vibrations can result in damage to the device.
Therefore, protect it against excessive vibrations, e.g. abrupt positioning or dropping, during transport. Always protect the device from slipping during transport.
Only lift or carry the device at the provided fixtures.
Positioning
- Inside the room to be dehumidified:
- The device works in recirculation mode, the regeneration air must be fed from outside and the regeneration exhaust air must be led outside.
- Outside the room to be dehumidified:
- The device can be connected in either recirculation or ventilation mode. A connection of the dry air to the room to be dehumidified must be established.
Storage
When the device is not being used, observe the following storage conditions:
- dry and protected from frost and heat
- in an upright position where it is protected from dust and direct sunlight
- with a cover to protect it from invasive dust, if necessary
- When not in use, always disconnect the device from the power supply.
- Up to 4 devices may be stacked on top of one another to save space.
- Secure stacks against toppling over.
Assembly and installation
- The pipes or hoses used must be designed for the available static compression of the fans. The air hoses should preferably be laid in a straight line and at full length.
- The regeneration exhaust air line must be laid with a slight decline so that possibly accumulating condensate cannot flow back into the device or obstruct the air flow. If an incline cannot be avoided, it is necessary to establish a condensate drain. As preventive action, the exhaust air pipe may be insulated.
- To prevent an immediate neutralization with the moist exhaust air, the humid air outlet should be guided away with a minimum distance of approx. 1 m in case of direct-intake devices.
Scope of delivery
The scope of delivery of the device contains:
- 1 x Dehumidifier
- 1 x Connection cable
- 1 x Instructions
There are further accessories optionally available, which can be obtained from the Trotec customer service.
Default settings
Generally, air conditioning units are equipped with one or more fans, which
must be overdimensioned accordingly to overcome resistances caused by pipes or
appliances. Usually, their speed cannot be adjusted. In order to set the air
quantities required for the application, a hydraulic compensation must be
carried out by means of throttle valves installed in front of or behind the
fan. This, however, results in an unnecessary and often considerable increase
in the noise level and energy consumption.
This device has one integrated variable-speed high-performance fan for each
air current supplying the nominal volumetric flow rates of the dry air and
regeneration air at maximum speed despite the air hoses (approx. 10 m length
each) being connected.
Moreover, for heating the regeneration air, the device has an installed heater
battery generating heat by means of ceramic PTC semiconductor elements. The
latter have a maximum surface temperature of approx. 240 °C, which they try to
maintain. The temperature-dependent resistance, which rises rapidly as of a
certain value (Curie temperature) when the heat reduction decreases, causes
self-regulating effects of the heating current consumption, i.e. when the air
temperature rises and/or the air volume decreases, the current consumption is
reduced (and vice versa). Furthermore, a destruction caused by overheating,
for instance due to a lack of regeneration air, can be virtually ruled out.
In order to reach a preferably low outlet humidity level with a minimum dry
air volume or to achieve the highest dehumidification performance with a
maximum dry air volume, it is important to set the regeneration air volume
correctly. The air volume must be adjusted until the value specified as
optimum heating current is indicated on the ammeter.
For all other applications with low requirements regarding the
dehumidification performance and dry air volume, the fan speed may be
decreased until the value specified as minimum heating current is indicated on
the ammeter. This allows you to achieve very good dehumidification results at
minimum energy input.
Operation
Operating element
No. | Designation | Meaning |
---|---|---|
17 | Mains switch | Switching the device on and off |
18 | Dry air speed controller | Setting the fan speed for dry air |
19 | Humid air speed controller |
(TTR 400 D / TTR 500 D)
| Setting the fan speed for humid air
20| Socket for external hygrostat| Connection for hygrostat operation
21| Ammeter| Indication of electric current
22| Operating hours counter| Indication of operating hours
Switch-on
Switch the device on by actuating the mains switch (17).
The integrated indicator light lights up.
Switch-off
Switch the device off by actuating the mains switch (17).
The integrated indicator light goes off.
Remote operation
Switch the device on by actuating the mains switch (17).
The integrated indicator light lights up.
Connect an external switch or external switching device,
e.g. a hygrostat or timer, to the socket (20) with the suitable Tuchel plug
(optional accessory). Always observe the information contained in the circuit
diagram (see Technical annex).
All electrical loads are now switched on or off by the external switch as
needed. The indicator light of the mains switch remains illuminated regardless
of the switching state and indicates that the control unit is activate. In
hygrostat operation, air circulation may in some cases be necessary at the
point of moisture measurement. In this case, the fan can be configured for
permanent operation by replugging a plug contact at the integrated relay. This
operation may only be carried out by an electrically skilled person. If
required, please contact the Trotec customer service.
Adjusting the air volume
Using the speed controllers (18) and (19) you can adjust the speed of the
fans.
- In order to increase the air volume, turn the speed controller to the right.
- In order to decrease the air volume, turn the speed controller to the left.
Errors and faults
Error | Diagnosis | Potential cause | Remedy |
---|---|---|---|
Dry air shows | Rotor drive | Check rotor | |
no | defective | drive | |
temperature | and have it | ||
increase | repaired | ||
if necessary | |||
Ammeter | Heating | Renew heating | |
No dehumidi- | indicates | defective | |
fication | strongly | ||
deviating | |||
values | |||
Ammeter | Regeneration | Check for free | |
indicates | air current is | air flow, check | |
deviating | insufficient | fan, clean or | |
values | renew air filter |
Service and repair
Warning
Risk of death due to improper repair!
Never try to make any modifications or repairs on the device. Unauthorised
modifications can lead to serious injuries or death. Have a certified
specialist workshop perform the repair work.
Repair work may only be carried out by trained specialist staff!
In case of a technical problem please try to rule out handling or application
errors before contacting our customer service.
For further questions regarding the function and operation of the dehumidifier
as well as for more information in the case of an error or else for warranty
issues we are of course always happy to be of service.
Please contact:
Trotec GmbH
Grebbener Straße 7
D-52525 Heinsberg
Tel.: +49 (0) 2452 / 962-400 Fax.: +49 (0) 2452 / 962-200 E-mail:
info@trotec.de
www.trotec.de
Maintenance
Activities required before starting maintenance
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
- Switch the device off.
- Hold onto the mains plug while pulling the power cable out of the mains socket.
Care
Warning of electrical voltage
Tasks which require the housing to be opened must only be carried out by
authorised specialist companies or by Trotec.
Note
Device may be damaged by improper cleaning!Only clean the inside with a damp
cloth or with compressed air. Do not bring any fluids into the inside of the
device!
The surface of the device housing is finished with an easy-to-clean powder
coating. Therefore, dirt can only adhere poorly and can be easily removed with
a damp cloth.
Cleaning of the inside and integrated components may only be carried out by
trained personnel or by the Trotec customer service.
Maintenance
Note
Device may be damaged by improper handling!Cleaning, maintenance and repair
work on electrical and mechanical components may only be carried out by
trained personnel or by the Trotec customer service!
The device is designed for long hours of operation with minimum maintenance effort. Safe operation of the device requires all built-in components to be checked and cleaned after 6 months at the latest or after every 4,000 operating hours as well as all damaged components to be replaced.
Filter change
Warning
Risk of injury due to fan!
Make sure to switch the device off and secure it against unintentional start-
up before you remove the air filter – especially if the fan’s inlet opening is
freely accessible.
The filter change intervals depend on the degree of air pollution and the filter quality. Dirty filters impair the performance ability of the dehumidifier. For this reason, they should be checked once a week (or daily in construction areas) and cleaned or replaced if required.
- Pull the filter cover off with a slight jerk and remove the filter mat.
- Clean the filter using a slightly damp, soft, lint-free cloth.
If the filter is heavily contaminated, clean it with warm water mixed with a neutral cleaning agent.
Info
Ex factory the device comes equipped with a reusable filter mat (PPI30). It can be cleaned by tapping and washing it out.
Allow the filter to dry completely. Do not insert a wet filter
Note
Device may be damaged by liquid.
Before reinserting the air filter, make sure it has dried completely. Otherwise there is a risk of the fan sucking in liquid leading to a short circuit and consequential damage.
Reinsert the air filter into the device.
Harmful influences on rotors
Some of the substances and compounds listed below are typical examples for
substances dissolving the honeycombed silica gel rotors or else negatively
affecting the dehumidification performance.
The sorption rotor should not be charged with air which is contaminated with
the following or similar substances. Even minor concentrations in the air can
have lasting harmful effects on the rotor material and the sorption capacity.
The listed substances remain in the rotor material or the rotor elements and can bring about the following effects:
- Reduced performance owing to the clogging of the silica gel’s pores
- Reduced performance owing to the chemical reaction with the silica gel
Moreover, the intake air must not contain any particles of substances with a melting point of less than 200 °C.
A) Inorganic substances (examples)
No. | Substances | Chemical formula | Effects |
---|---|---|---|
1 | lithium chloride | LiCl | reduced productivity of the silica gel1) |
2 | sodium hydroxide | NaOH | destruction of the silica gel structure |
3 | potassium hydroxide | KOH | destruction of the silica gel structure |
4 | sodium chloride | NaCl | reduced productivity of the silica gel1 |
5 | potassium chloride | KCl | reduced productivity of the silica gel1 |
6 | calcium chloride | CaCl2 | reduced productivity of the silica gel1) |
7 | magnesium chloride | MgCl2 | reduced productivity of the silica gel1) |
8 | ammonia | NH3 | destruction of the silica gel structure |
9 | hydrofluoric acid | HF | destruction of the mechanical strength of the rotor |
material
10| aluminium chloride| AlCl3| reduced productivity of the silica gel1)
11| sea water| | reduced productivity of the silica gel1)
12| steam with a high temperature| | destruction of the silica gel structure
13| softener| | clogging of the silica gel’s pores
14| strong acids| pH ≤ 2…3| destruction of the mechanical strength of the
rotor material
15| bases| pH ≥ 7…8| destruction of the sorption capacity of the silica gel
16| amines| R-NH2| reduced productivity of the silica gel1)
B) Organic substances (examples)
The solvents or volatiles listed below have a high boiling point and a low
vapour pressure. Provided these substances are adsorbed by silica gel, they
remain in the material on a permanent basis.
No. | Substances | Chemical formula | Effects |
---|---|---|---|
1 | oil mist | clogging of the silica gel’s pores | |
2 | cyclohexanone | C6H10O | reduced productivity of the silica gel1) |
3 | isopropyl alcohol | CH3H8O | reduced productivity of the silica gel1) |
4 | o-xylene | C8H10 | reduced productivity of the silica gel1) |
5 | m-xylene | C8H10 | reduced productivity of the silica gel1) |
6 | p-xylene | C8H10 | reduced productivity of the silica gel1) |
7 | phenol | C6H5OH | reduced productivity of the silica gel1) |
8 | o-dichlorobenzenes | C6H4Cl2 | reduced productivity of the silica gel1) |
9 | methyl bromide | CH3Br | reduced productivity of the silica gel1) |
10 | glycerin | C3H8O3 | reduced productivity of the silica gel1) |
Disposal
The icon with the crossed-out waste bin on waste electrical or electronic
equipment stipulates that this equipment must not be disposed of with the
household waste at the end of its life. You will find collection points for
free return of waste electrical and electronic equipment in your vicinity. The
addresses can be obtained from your municipality or local administration. You
can also find out about other return options that apply for many EU countries
on the website https://
hub.trotec.com/?id=45090 Otherwise, please contact an official recycling
centre for electronic and electrical equipment authorised for your country.
The separate collection of waste electrical and electronic equipment aims to
enable the re-use, recycling and other forms of recovery of waste equipment as
well as to prevent negative effects for the environment and human health
caused by the disposal of hazardous substances potentially contained in the
equipment.
Technical data
Parameter | Value * |
---|---|
TTR 400 | TTR 400 D |
Article number | 1.110.000.020 |
EAN number | 4.052.138.007.488 |
Dehumidification capacity | 1.2 kg/h |
Operating range, dry air | 130 to 450 m³/h |
Nominal dry air flow rate / static pressure | 350 m³/h / 150 Pa |
Pa | 480 m³/h / 150 Pa |
Nominal humid air flow rate / static pressure | 50 m³/h / 80 Pa |
Pa | 80 m³/h / 80 Pa |
Intake temperature | -15 °C to +35° C |
Ambient temperature | -20 °C to +40 °C |
Electrical connection | 200 – 240 V / 50/60 Hz |
240 V / 50/60 Hz
Max. current consumption| 7.0 A| 7.3 A| 10.0 A
Heating current min. / opt. / max.| 4.5 / 5.5 / 6.0 A| 6.0 / 7.5 / 8.5 A| 7.0
/ 8.5 / 10.5 A
Length approx.| 400 mm| 400 mm| 450 mm
Width approx.| 350 mm| 350 mm| 400 mm
Height approx.| 405 mm| 405 mm| 455 mm
Weight| 17 kg| 20 kg| 25 kg
Dry air connection| 125 mm| 125 mm| 125 mm
Humid air connection| 80 mm| 80 mm| 80 mm
Sound pressure level (distance 1 m)| 63 dB(A)| 63 dB(A)| 74 dB(A)
- based on 20 °C / 60 % RH
Circuit diagram TTR 400
Circuit diagram TTR 400 D
Circuit diagram TTR 500 D
Dimensions TTR 400
Dimensions TTR 400 D
Dimensions TTR 500 D
Spare parts drawing and list TTR 400
Info
The position numbers of the spare parts differ from those describing the
positions of the components mentioned in these instructions.
Item| Designation| Article number| Item| Designation|
Article number|
---|---|---|---|---|---|---
1| Basic housing| P 1000 2084| 20| Ammeter| P 1000 0179
2| Cover| P 1000 2085| 21| Operating hours counter| P 1000 1137
3| Panel| P 1000 2086| 22| Cable bushing| P 1000 1247
4| Rotor cassette| P 1000 2088| 23| Filter mat| P 1000 0671
5| ADS filter hood| P 1000 2091| 24| Filter mat| P 1000 0672
6| REG filter hood| P 1000 2093| 25| Fan| P 1000 0536
7| Rubber tensioner| P 1000 1059| 26| Gear motor| P 1000 1160
8| Heating frame| P 1000 2090| 27| Toothed belt pulley| P 1000 0279
9| Handle| P 1000 1246| 28| Pressure spring| P 1000 1055
10| Fan| P 1000 0534| 29| Heating plate| P 1000 0273
11| Power adapter| P 1000 1208| 30| Heating element| P 1000 7148
12| Relay| P 1000 0195| 31| Heating element| P 1000 1182
13| Switch| P 1000 1376| 32| Toothed belt| P 1000 1065
14| Potentiometer| P 1000 1751| 33| Rotor| P 1000 1216
15| Speed controller| P 1000 0291| 34| Foot| P 1000 0425
16| Rotary button for potentiometer| P 1000 1250| 35| Mounting clip for relay|
P 1000 0196
17| Needle bush| P 1000 1061| 36| Lock nut for cable bushing| P 1000 1248
18| Connection socket| P 1000 1049| 37| Exhaust air hose| P 1000 1069
19| Protective cap| P 1000 1053|
Spare parts drawing and list TTR 400 D
Info
The position numbers of the spare parts differ from those describing the
positions of the components mentioned in these instructions.
Item| Designation| Article number| Item| Designation|
Article number
---|---|---|---|---|---
1| Basic housing| P 1000 2101| 19| Ammeter| P 1000 1234
2| Cover| P 1000 2102| 20| Operating hours counter| P 1000 1137
3| Panel| P 1000 2103| 21| Cable bushing| P 1000 1247
4| Rotor cassette| P 1000 2105| 22| Filter mat| P 1000 0671
5| ADS filter hood| P 1000 2091| 23| Filter mat| P 1000 0673
6| REG filter hood| P 1000 2110| 24| Fan| P 1000 1745
7| Rubber tensioner| P 1000 1059| 25| Gear motor| P 1000 1160
8| Heating frame| P 1000 2107| 26| Toothed belt pulley| P 1000 0278
9| Handle| P 1000 1246| 27| Pressure spring| P 1000 1055
10| Fan| P 1000 0534| 28| Heating plate| P 1000 0274
11| Power adapter| P 1000 1208| 29| Heating element| P 1000 7148
12| Relay| P 1000 0195| 30| Toothed belt| P 1000 1262
13| Switch| P 1000 1376| 31| Rotor| P 1000 1215
14| Potentiometer| P 1000 1751| 32| Foot| P 1000 0425
15| Rotary button for potentiometer| P 1000 1250| 33| Mounting clip for relay|
P 1000 0196
16| Needle bush| P 1000 1061| 34| Lock nut for cable bushing| P 1000 1248
17| Connection socket| P 1000 1049| 35| Exhaust air hose| P 1000 1069
18| Protective cap| P 1000 1053|
Spare parts drawing and list TTR 500 D
Info
The position numbers of the spare parts differ from those describing the
positions of the components mentioned in these instructions.
References
- The Trotec Group: best conditions for your success - TROTEC
- Lösungen für Industrie, Handwerk und zu Hause - TROTEC
- Desiccant dehumidifier Trotec TTR 400 - TROTEC
- Desiccant dehumidifier Trotec TTR 400 D - TROTEC
- Desiccant dehumidifier Trotec TTR 500 D - TROTEC
- WEEE-Annahmestellen | Interzero - zero waste solutions
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>