Christ E702613 Touch-It CE Front Panel Glass Instruction Manual

June 5, 2024
Christ

Christ E702613 Touch-It CE Front Panel Glass

Operating Instructions

Document No: PA10003599
Revision: 01
Date: 23 Sep. 20
Address: Christ Electronic Systems GmbH Alpenstraße 34 DE-87700 Memmingen
Telephone Fax: + 49 (0)8331 8371 – 0, + 49 (0)8331 8371 – 99
E-Mail: info@christ-es.de
Internet: http://www.christ-es.de
Copyright: No part of this documentation may in any form be reproduced, copied or distributed by means of electronic systems without previously written permission by Christ Electronic Systems GmbH. The translation into another language also requires written permission. This documentation may be exclusively entrusted to the owner of the installation or to the employees of Christ Electronic Systems GmbH.
Technical changes: Christ Electronic Systems GmbH reserves the right to change specifications, executions and technical data held within this document without prior notice.
Trademarks: Brand and product names are trademarks or registered trademarks of their respective owners.

General

Used Symbols

Symbol:
The following symbols are used in this instruction manual

DANGER!
Denotes a direct threat of danger. Not observing this pointer may be life- threatening or lead to serious injuries.
CAUTION!
Denotes a possibly dangerous situation. Not observing this pointer can cause minor injuries or lead to material damages.
INFORMATION!
Denotes application pointers and other useful information.

General Pointers

INFORMATION
This device was manufactured according to DIN EN ISO 9001 and left the factory in a perfect state. In order to maintain this state and to assure a safe operation, the user must consider the pointers and warning remarks, which are contained in this instruction manual.
Please check immediately: Is the device damaged or is any equipment missing? (See chapter Commissioning) In the case of a defect please inform us immediately.

CAUTION

Intended Use
These products are not designed, developed and produced for use, which pose fatal risks and dangers that may cause death, injuries, serious physical impairments or other loss, if no exceptional security measures are ensured. Thus there are limitations for use in the monitoring of nuclear reactions in nuclear power plants, flight control systems, air traffic control, in the control of mass transportation, medical life support systems and control of weapon systems.

If the device is used for other purposes or incorrectly operated, Christ Electronic Systems GmbH will not hold damages liable.
Do not operate the touch-sensitive surface of the screen with any abrasive or sharp-edged objects.
Protect the Touch-it Panel PC against caustic chemicals and long solar radiation.
Never cover the Touch-it Panel PC completely or build it in a small closed and unvented housing.
This is a Class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.

DANGER
In the case of damage of the device, shut it down and disconnect it immediately from the supply voltage.
Disconnect every connection line and send it back to Christ Electronic Systems GmbH.
Only the qualified staffs are allowed to carry out the repairs. The incorrect repair may lead to serious danger for the user.

Cleaning

INFORMATION
Use a humid and soft cloth with gentle soap suds to clean.

CAUTION
Do not clean the touch-sensitive surface of the monitor with detergents containing solvent or acid.

INFORMATION
The device is certificated for operation in the US and Canada and complies with FCC regulations. The certification is available on request.

Type label:Christ-E702613-Touch-It-CE-Front-Panel-
Glass-1

International Certification USA:

FCC (Federal Communications Commission)
The device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause any harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operations.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits of Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Operation of this equipment in a resident area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Technical Data

SystemChrist-E702613-Touch-It-CE-Front-Panel-
Glass-2

Power SupplyChrist-E702613-Touch-It-CE-Front-Panel-
Glass-3

Mechanical & EnvironmentalChrist-E702613-Touch-It-CE-Front-Panel-
Glass-4

 Commissioning

Mounting Front Panel
The variant Touch-it CE Front Panel is designed for front mounting. Each Front Panel has its own cut-out drawing.  Christ-E702613-Touch-It-CE-Front-Panel-
Glass-5
To clamp the Front Panel into the cut-out you can use the pre-assembled fasting clamps.

Turn fasting clamp to the side Screw-in the setscrew

CAUTION For the best installation results the use of all pre-assembled fasting clamps is highly recommended. Depending on individual installation circumstances a new IP rating may be considered.

Mounting VESA

The variant Touch- it CE VESA is designed for VESA MIS-D, 75, mounts.Christ-E702613-Touch-It-CE-Front-Panel-Glass-8

Suitable mounting variants are:Christ-E702613-Touch-It-CE-Front-Panel-
Glass-9

Technical Drawing 

Christ-E702613-Touch-It-CE-Front-Panel-
Glass-10

FRONT PANEL E702613Christ-E702613-Touch-It-CE-Front-Panel-
Glass-11

VESA E702617Christ-E702613-Touch-It-CE-Front-Panel-
Glass-12

PA10004391Christ-E702613-Touch-It-CE-Front-Panel-
Glass-13

Interfaces

Christ-E702613-Touch-It-CE-Front-Panel-
Glass-14

INTERFACES COM Connector Pinning

Pin Function Description
1 GND Ground
2 GND Ground
3 RS485_P RS485 Positiv
4 RS232_TX RS232 Transmitter Signal
5 RS232_RX RS232 Receiver Signal
6 RS485_N RS485 Negative
7 CAN_Low CAN Low Signal
8 CAN_High CAN High Signal

Power supply

The power supply was part of the safety and EMC certification and it is necessary to use this kind or a similar one in respect of the technical data: Christ-E702613-Touch-It-CE-Front-Panel-Glass-15
Changing the type of the power supply without our permittion, may cause problems with the conformitiy of the certifications and therefore is not guaranteed
The device is only permitted to be supplied with a SELV/PELV power supply or with safety extra lowvoltage (SELV) per EN 62368-1

Software

The highly customized software consists of:

  • Bootloader: Das U-Boot
  • Linux (poky/ces-fb based)
  • Kiosk browser based on chromium

The system is configured to load a pre-set webpage and offer no additional method of configuration and does not allow any other use for the operator.
The system admin can configure the system via ssh.

Accessing the System

Accessing the System via SSH (Secure Shell)
SSH can be used for encrypted login over the network or for encrypted file transfer between your PC and the device.  ssh root@ <IP address of the device>

Example: user@linux-pc:~$ ssh root@10.15.15.16
The authenticity of host ‘10.15.15.16 (10.15.15.16)’ can’t be established.
RSA key fingerprint is 54:09:6d:2e:c6:b3:09:06:8d:4b:a8:0c:a8:7d:64:4a.
Are you sure you want to continue connecting (yes/no)? yes
Warning: Permanently added ‘10.15.15.16’ (RSA) to the list of known hosts.
root@10.15.15.174’s password:
root@pixidl:~#
SSH uses port 22. User name and password are the same as for serial (RS232) login.

User: root
Password: root123
Because the IP address of the device is set to DHCP, nmap can be used to scan for the eval kit
sudo nmap –sP <network identifier/netmask>

Example: sudo nmap –sP 10.15.15.0/24-
This scans from IP address 10.15.15.0 to 10.15.15.255

Rebuilding the Image

Our source repositories and short instructions on how to rebuild the image can be found on: https://github.com/software-celo/ces-bsp-platform.

Recover the Delivery State

To recover the delivery state of the image you can follow the instructions found in the CURT User Guide https://christelectronicsystems.box.com/v/curt- manual (PA10002483).

DISCLAIMER

Technical data are subject to modification and delivery subject to availability. Any liability that the data and illustrations are complete, actual or correct is excluded. Designations may be trademarks and/or copyrights of the respective manufacturer, the use of which by third parties for their own purposes may infringe the rights of such owner. Christ-E702613
-Touch-It-CE-Front-Panel-Glass-166555

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals