Guangzhou Chuangwei Electronic Technology H58 Bluetooth Neck Massager User Manual
- June 5, 2024
- Guangzhou Chuangwei Electronic Technology
Table of Contents
Guangzhou Chuangwei Electronic Technology H58 Bluetooth Neck Massager User Manual
Product Diagram
Wearing Method
Operation Method
- Before use. fist wet the skin of the cervical spine with a wet towel, and then put the product around the neck, make the electrode close to the skin of the cervical spine, adjust the position of the product, turn on the host and adjust the appropriate massage intensity and mode.
- Long press the host”o” button for two seconds, turn on the host (with the buzzer” beep ” sound and prompt light), enter the default mode with the default level (0). Press the host button, add the intensity by one level with a” beep” sound. Until level 15, press the button and hear two ” beep “sounds with no intensity change. Long press host”w”for two seconds when the machine is on, hear two ” beep ” sounds and turn off the products.
- ” M” on the remote control is the mode button. Press the mode button to switch the mode. There are three modes. After each press, it will send out” beep” sound and switch to higher mode. The three modes can be switched in cycle (Note; M1 mode, M2 mode, M3 mode). Each time a mode is switched, the intensity returns to the default 0 level.
- ‘ +”on the remote control is the intensity increase button. After each press, it will send out “beep”sound and switch to higher mode. The intensity is divided into 15 levels (0, 1, 2..15). When the intensity is at level 15, when pressing”± ” , it will send out two”beep” sound with same intensity at level 15.
- “—”on the remote control is the intensity decrease button. After each press, it will send out beep sound and switch to lower mode. The intensity is divided into 15 levels (0, 1,2… 15) When the intensity is at level 0, t will send out two”beep” sound with same intensity at level 15 after pressing”—.”
- ” iron the remote control is the heating button. Press the heating button and start host heating function with a beep” sound. The two electrode will be hot at the temperature of 3743″C. Press thee” button again and the buzzer will” beep “twice to stop adding the host Heat function.
- The host is scheduled for 15 minutes. When the host is turned on, it will automatically shut down after 15 minutes.
- When the host is turned on, the product will automatically shut down in 30 seconds when the product is not put on normally.
- For the voice version, there will be corresponding prompt voice broadcast function when you press the button, such as broadcasting the first/second/third file, etc. The specific product model shall prevail.
Product charging
- When the host battery is running out, the power button lights up in orange. You can use the Micro-USB cable to plug into the other end of the host and plug in the charger with the Android head (the output is 5V1A/2A). When charging, the orange light flashes. When it is full, the blue light flashes.
- When the remote control battery is replaced, a coin can be inserted into the battery knob slot. Turn it counterclockwise to the alignment position to open the replacement battery. Note that the battery positive pole is facing up. (Battery model: Cr2032)
How to use bluetooth headset
- Power button: long press to turn on/off
- short press to play/pause music.
- When have incoming call, short press to answer the call, short press again to hang up. long press can refuse the call.
- Continue press two times will redial the last phone number you dialed.
- Key +:1ong press for turn up the volume, short press for move previous song.
- Key -:long press for turn down the volume, short press for move next song.
- Long press the power button about three seconds to boot, the blue and red light flashing, it’s the state of the pairing. At this time, search the corresponding wireless device name on the mobile phone, click the name on the mobile phone for the wireless pairing. Hear “connected”means the pairing is successful •if not connect with any wireless devices and without any operation, the earphone will automatically turn off after 5 minutes.
Tips
- The product will be automatically turned off after 15 minutes of operation. It is recommended to use it for no more than 30 minutes per day.
- The product should be stored in a dry and ventilated place after use.
- Do not place other weights on the product.
- Don’ t pull on the rubber plug at the USB charging port, as it may cause rupture and falling off.
Routine maintenance
- When cleaning and maintaining this product, please turn off the host, use a wet paper towel to clean the electrode. When it is particularly dirty, use a little medical alcohol (alcohol concentration 75%) to wipe and disinfect.
- Please wipe with neutral detergent and soft cloth during daily maintenance, do not use corrosive detergent and don’ t place it into water for soaking or washing.
- During the cleaning process, water or other liquids should be prevented from entering the body to avoid short circuit and electric shock during use.
Troubleshooting
- If you have problems using the product, please refer to the following tips and solutions.
- If the product is still in a fault condition or cannot be used, turn off the power.
- Users should not disassemble or repair the product by themselves. Dismanting or repairing by themselves will cause damage to the product and cause the invalidity of warranty. The company will not be responsible for any consequences caused thereby.
Problems | possible cause/treatment |
---|---|
Failure to start |
- The internal rechargeable battery is runninglow
- The remote control battery is dead.
- Please confirm whether the host product switch has been pressed.
Failure to charge
or no charge light| Please check if the USB cable and host and phone power
adapter are connected
Normal display but no
stimulation|
- Does the pad contact the skin directly? Adjust the position so that it is close to the skin.
- Is there hair or clothing, jewelry, etc. between the pads and the skin? Move away or remove items
- Is the intensity level at 0? Increase the massage intensity.
Tingling sensation|
- Is the massager’s electrode and neck skin closely contacted? adjust the position so thatit’ sstick to the skin.
- Is the massage time too long? It is recommended to massage for 15 minutes at a time, twice a day. Ms the massage intensity too high? Adjust to low level
- Is the skin allergic to the electrode? Those with severe allergies need to be desensitized first.
- Is the climate cold and the skin dry? Use a wet towel to moisten the skin and use it.
- Does the skin have a wound? Do not put the electrodes on the wound for massage.
Weak simulation|
- Is the massager s electrode and neck skin closely contacted? adjust the position so that it’ s stick to the skin and adjust intensity.
- Is the electrode dirty or oily? Clean the electrode surface.
- Is the battery running low? Please charge if the battery is low.
- Is massage intensity level too low? Increase massage intensity.
Precautions
Danger
Please never use the product with the following medical electronic devices:
-
Heart pacemakers and other implantable medical electronic devices;
-
Artificial heart and lungs and other life-supporting medical electronic devices;
-
Electrocardiographs and other medical electronic devices;
These medical electronic devices may cause malfunctions and can be life- threatening. -
Petrol stations, high dust workshops, gas and other inflammable and easy-explosive area are prohibition of use,
Warning
- If the patient applies high-frequency surgical device and the product on the body at the same time, the electrode of the product may cause burns and damage to the product.
- If the product is used near (1M)a short-wave or microwave therapy device, the output of the product may be unstable.
- The electrode should prevent contact with wounds and scars during treatment.
- When you sue the product, don’ t place the electrode near the chest heart, otherwise the risk of heart fibrillation will increase.
- The product is recommended for use by one user. When it’ s used by different users, clean the electrode on the product before using it.
- When you use the product, stick the electrode tightly and evenly to the skin.
- The electrode of this product has a heat generating function. When the hot compress function is applied on the same part for a long time (more than 15 minutes), it may cause low temperature burns.
- If you feel unwell during or after use, stop using it and seek medical attention.
- This product contains a lithium battery. Don’ t disassemble, modify, flood the product, or throw it into fire, otherwise it may result in product damage and explosion
- In the following cases, consult your doctor before use, otherwise it may cause accidents or cause physical discomfort,
- Patients under medical treatment and feel discomfort.
- Patients with abnormal heart and brain nerves.
- Patients whose body temperature exceeds 38 degrees (fever period).
- Patients with infectious diseases.
- Patients with skin perceptual disorders or skin abnormalities.
- Patients under medication
- Patients with abnormal blood pressure.
- Patients who are not free to express their wishes.
- Patients with sensory impairment due to high peripheral circulatory disorders such as diabetes.
- Patients with skin allergies to stainless steel electrodes.
Usage under the following conditions is prohibited.
- Malignant tumor patients
- Patients with bleeding tendency
- Pregnant women, lying-in women
- Acute suppurative inflammation patients
- Heart pacemaker users
- Patients with metal implant
- Near the heart
- Don’ t apply it near the heart, above the neck, head, mouth, genitals, or skin disorders and don’ t treat the soles of the feet simultaneously. In addition, don’ t compress the internal organs when using. Otherwise, an accident or physical discomfort may occur.
- Don’t use with other medical devices or more than 2 products. Otherwise, nausea or physical discomfort may occur.
- Don’ t use for purposes other than the ones described in the instruction manual. Otherwise, accident or malfunction may occur.
- Don’ t use the electrode with a chipped or damaged surface. Otherwise, accidents or malfunctions may occur
- Don’ t disassemble, repair or modify this product without authorization. Otherwise, malfunction or electric shock may occur.
Note
- If you feel unwell due to an abnormality in this product, stop using it immediately.
- If your body or skin feel strange, consult your doctor and follow the doctor’s advice.
- if you want to move the pad or place it other on other person during massage, be sure to turn off the power before moving it. Otherwise, you may receive a strong electric shock.
- Don’ t treat while having electronic devices. Otherwise, the electronic device may malfunction (for example, the electronic watch disorder).
- If abnormal operation occurs, immediately switch off the power supply and remove it. Otherwise, high temperatures or short circuits may occur and lead to an accident. At the same time contact customer service for after-sales advice.
- Don’t plug or unplug the USB charging cable with wet hands. Doing so may result in electric shock or accident.
- Don’ t use it for children or people who have no expressiveness, otherwise it may cause an accident or cause discomfort.
- Don’ t use it in a place with high humidity, such as a bathroom, or use it while bathing. Otherwise, you may receive a strong electric shock and damage the product.
- •Don’ t use it when you are sleeping. Otherwise, it may cause the main body to malfunction. In addition, the pad may move to other parts and cause discomfort.
- Don’ t use while driving a car, otherwise it may cause physical discomfort due to excessive stimulation, resulting in an accident.
- Don’ t stick the electrode to the affected area for a long time, other wise it may cause skin inflammation.
- When massaging, don’ t use the matal parts of belts, necklasce, etc., to touch the electrode, otherwise you may receive a strong electric shock.
- Don’ t apply the product on the same place for long time (more than30 minutes), otherwise it may cause muscle fatigue at the massage site to cause physical discomfort.
- Please wear this product correctly and use it on the cervical spine. Wear it symmetrically. Otherwise, accidents or physical discomfort
- may occur.
- When unplugging the USB charging cable from the body, do not pull on the cable, but rather, pull the cable plug and pull it out. Otherwise, it may result in electric shock or damage to the product.
- The product electrode has a surface heating function for users who are not sensitive to heat or subject to heat allergies.
- Please consult a doctor before use.
- When the product is working for a long time, the surface will be hot, which is normal.
- when the remote control battery is idle for a long time (more than 3 months), remove the battery.
- When the remote control battery is exhausted, replace it with anew battery of the same model as soon as possible. Battery model: Cr2032.
- When replacing the remote control battery, do not install the pole reversibly.
- After the remote control battery is exhausted, dispose of it according to the relevant regulations in your place of residence.
Suggestion
- Please make sure that the host button is working properly.
- When you use it for the first time, or if the battery loses power after the product has been left idle for a long time, please perform the charging operation according to the instruction manual to ensure that it can work normally.
- When disposing of this product, please dispose of it in accordance with the relevant environmental protection regulations of the city, otherwise
- it may cause environmental pollution. It is recommended for people aged 16 and above.
- Don. t use or store this product in the following locations:
- Places exposed to direct sunlight
- Places subject to high temperature and humidity
- Places with water
- Dusty places
- Places near the fireworks
- Places susceptible to vibration shocks
- Strong electromagnetic places
Customer Support
Guangzhou Chuangwei Electronic Technology Co. Ltd :
Address: No. 5, Dongguan Village Commercial Street, Xinya Street, Huadu
District, Guangzhou City.
020-61852750
CustomerServiceHotline: 020-61852750
www.HGKGD.com
Visit us for more information www.HGKGD.com
FCC Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation
NOTE: This equipment has been tested and found to comply with the limits
for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the
following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Warning: changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>