Medisante BC800 3G Body Weight Scale Instruction Manual

June 5, 2024
Medisante

Medisante-BC800-3G-Body-Weight-Scale-logo

Medisante BC800 3G Body Weight Scale

Medisante-BC800-3G-Body-Weight-
Scale-product

Intended use:
The Body Weight Scale BC800 3G is a digital monitor for home/domestic use which measures the weight of persons 18 years of age or more.

Package contents

Insert batteries

  1. Place the scale upside down on a fl at the surface being careful not to scratch it.
  2. Remove the battery cover and insert 4×1.5V AAA alkaline batteries with the correct polarity.

Display Indicators

Medisante-BC800-3G-Body-Weight-Scale-
fig-3

Overload Indicator
ERR Scale is overloaded (max. 180 kg, 396 lbs, 28.3 st)

Low Battery Indicator
LO Batteries are low and need to be replaced.

  1. Remove the battery cover.
  2. Insert batteries.
  3. Replace the battery cover.

Operating Instructions

  1. Place the scale on a hard, fl at the surface.
  2. Step on the scale and remain still during the measurement.
  3. When the “data send in progress” indicator is displayed, the data is being sent and you may step off the scale.
  4. After a period of time, the data send status will be displayed. If it shows a  “data send failure”, move the scale to a new location and try again.

Notes

  • → Weight measurements are possible with shoes and socks on.
  • → Calibration: if you place the body weight scale BC800 3G at the new place, quickly step with one on it, until the display turns on. Step off and wait until the calibration gets performed(10-15 seconds)and the display switches off.
  • → If there is no signal strength indicator and you continue to receive a data send failure, contact your distribution partner.
  • → user should clean the glass surface before use.
  • → Please contact [email protected] for troubleshooting and maintenance.

Automatic Shutdown
If no measurement is being taken, the scale will automatically turn off in 10 seconds.

Important Safety Information

  • Please read the entire instruction manual and safety precautions before using the Body Weight Scale BC800 3G.
  • Unusual measurement values should be discussed with your doctor or health care professional.
  • Never change the dosage of any prescribed medications without fi first consulting your doctor or health care professional.
  • Always perform the measurements on a hard and fl at the surface. Uneven fl doors may affect the readings.
  • If necessary, clean the Body Weight Scale BC800 3G with a damp cloth and a small amount of dishwashing liquid. When the surface is dirty.
  • Never immerse the scale in water or rinse it under running water.
  • Protect the Body Weight Scale BC800 3G against knocks, moisture, dust, chemicals, drastic changes in temperature, and electro-magnetic fi eds.
  • Keep the Body Weight Scale BC800 3G away from any sources of heat.
  • Never step on the outer edge of the glass. This could cause the scale to tip or damage the glass.
  • Keep packaging materials away from children. Store the Body Weight Scale BC800 3G horizontally, not vertically.
  • If the measurement appears inaccurate or if the LCD display does not show any fi figures, please check that the batteries are correctly inserted and the battery contacts are clean.
  • If the Body Weight Scale BC800 3G will not be used for an extended period of time, remove the batteries from the Weight Scale BC800 3G and store it properly. Do not store other objects on top of it.
  • Please use the device in a dry and clean envi-ronment, and place the device on a fl at the ground before use.
  • Do not use hot water, volatile oil, or rosin oil to clean the scale.
  • Please store at room temperature, keep in a dry and cool place and avoid sun exposure. Do not run or jump near the Body Weight Scale BC800 3G.
  • This product is applied parts(type BF). No maintenance is required during the product life cycle.
  • EBM Technologies Inc. will provide circuit diagrams, component part lists, descriptions, and calibration instructions to assist to service personnel in parts repair.
  • 300 Measurements (Info: the Battery life depends on the used batteries.
  • The time required for the scale to warm from -25oC between uses until the scale is ready for its intended use when the ambient temperature is 20oC is 2 hours.
  • The time required for the scale to cool from 40oC between uses until the scale is ready for its intended use when the ambient temperature is 20oC is 2 hours.
  • If the degraded sensors and electrodes, or loosened electrodes, can cause weight measurement failure .please contact EBM Technologies Inc.
  • The waste products and batteries should follow the domestic waste disposal regulation. Product life expectancy: 5 years.
  • operation environment:
    • Temperature (ºC),/Relative Humidity (%)/Atmospheric Pressure (kPa): 10~40 ºC /15~90%RH / 70 kPa ~106 kPa
    • Home healthcare.
  • Transportation and storage environment:
    • Temperature (oC),/Relative Humidity (%)/Atmospheric Pressure (kPa): -25~40°C / 10~95%RH / 70 kPa ~106 kPa

To Avoid Injury

  • Only use this device for its intended use and in accordance with the instruction manual.
  • Do not use the device if it is damaged in any way.

Warning

  • known contraindication: People who are equipped with Pace Maker or another implant device shall not use this scale.
  • The scale shall not be broken down or maintained in operation.
  • Scale release a week currently and it passes through the body. The current may affect electrical products and cause erroneous operations. The failure may become the cause of major accidents.
  • Do not use a mobile phone or low-frequency therapy device near the Scale.
  • Prohibit any modifi cation of the scale, it may cause hazards.

FCC compliance statement

changes or modifi cations not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

FCC SAR statement

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. End-user must follow the specifi c operating instructions for satisfying RF exposure compliance. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. The portable device is designed to meet the requirements for exposure to radio waves established by the Federal Communications Commission (USA). These requirements set a SAR limit of 1.6 W/kg averaged over one gram of tissue. The highest SAR value is reported under this standard during product certifi cation for use when properly worn on the body.

Specification

Medisante-BC800-3G-Body-Weight-Scale-
fig-4

Symbol DescriptionMedisante-BC800-3G-Body-Weight-Scale-
fig-5
Hereby, EBM Technologies Inc. declares that the radio equipment type BC800 3Gis in compliance with directive FCC ID (FCC PART 22/24, IEEE 1528, KDB447498), IEC60601-1: 2005+A1: 2012, IEC60601-1-11: 2015, IEC606601-1-2: 2014, 2014/53/EU, 2014/30/EU, 2011/65/EU. EBM Technologies Inc. declares that the medical device weight scale BC800 3G is listed in FDA(Registered Establishment Number: 3004722076).

Manufacturer
EBM Technologies Inc. Address: 5F. No. 516 Sec. 1 Neihu Road Taipei, Taiwan

Distribution by

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals