FLYTECH M276 and M278 Hybrid POS Hospitality User Manual
- June 3, 2024
- FLYTECH
Table of Contents
FLYTECH M276 and M278 Hybrid POS Hospitality
Safety
-
Regulatory Information
Caution: Only use approved and UL Listed accessories, battery packs and battery chargers. Do NOT attempt to charge damp/wet mobile computers or batteries. All components must be dry before connecting to an external power source. -
Power Supply
Use only the approved power supply output rated 12 Vdc and minimum 3 A. The power supply is certified to EN60950-1 or EN62368-1 with SELV outputs. Use of alternative power supply will invalidate any approval given to this device and may be dangerous.
Warning for Use of Wireless Devices
Please observe all warning notices with regard to the usage of wireless devices. -
Potentially Hazardous Atmospheres
You are reminded of the need to observe restrictions on the use of radio devices in fuel depots, chemical plants etc. and areas where the air contains chemicals or particles (such as grain, dust, or metal powders)
and any other area where you would normally be advised to turn off your vehicle engine. -
Safety in Aircraft
Switch off your wireless device whenever you are instructed to do so by airport or airline staff. -
Pacemakers
Pacemaker manufacturers recommended that a minimum of 15cm (6 inches) be maintained between a handheld wireless device and a pacemaker to avoid potential interference with the pacemaker. These recommendations are consistent with independent research and recommendations by Wireless Technology Research. -
Persons with Pacemakers
Persons with Pacemakers should ALWAYS keep the device more than 15cm (6 inches) from their pacemaker when turned ON and hence they should not carry the device in a breast pocket .Should use the ear furthest from the pacemaker to minimize the potential for interference.
If you have any reason to suspect that interference is taking place, turn OFF your device. -
Hearing Aids
The wireless device may interfere with some hearing aids. In the event of interference you may want to consult your hearing aid supplier to discuss solutions. -
Other Medical Devices
Please consult your physician or the manufacturer of the medical device, to determine if the operation of your wireless product may interfere with the medical device.
FCC/EU RF Exposure Guidelines
FCC Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device complies with FCC SAR exposure limits set forth for an
uncontrolled environment.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
FCC RF Radiation Exposure Statement:
- This Transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
- For body worn operation, this device has been tested and meets FCC RF exposure guidelines. When used with an accessory that contains metal may not ensure compliance with FCC RF exposure guidelines.
Caution!
Any changes or modifications not expressly approved by the party responsible
for compliance could void t he user’s authority to operate the equipment.
Battery Information
- Our rechargeable battery packs are designed and constructed to the highest standards within the industry.
- However, there are limitations to how long a battery can operate or be stored before needing replacement.
- Many factors affect the actual life cycle of a battery pack, such as heat, cold, harsh environmental conditions and severe drops.
- When batteries are stored over six (6) months, some irreversible deterioration in overall battery quality may occur. Store batteries discharged in a dry, cool place, removed from the equipment to prevent loss of capacity, rusting of metallic parts and electrolyte leakage.
- When storing batteries for one year or longer, they should be charged and discharged at least once a year. If an electrolyte leakage is observed, avoid any contact with affected area and properly dispose of the battery. Batteries must be charged within the 32° to 95° F (0° to +35° C) ambient temperature range.
- Replace the battery when a significant loss of run time is detected.
Battery Caution
Risk of explosion if battery is replaced by an incorrectly type. Dispose of
used battery according to the local disposal instructions.
Waste Electrical and Electronic Equipment (WEEE)
English: For EU Customers: All products at the end of their life must be
returned to the reseller for recycling.
Notational Conventions
The following conventions are used in this document:
- Italics are used to highlight specific items in the general text, and to identify chapters and sections in this and related documents.
- bullets (•) indicate:
- action items
- lists of alternatives
- lists of required steps that are not necessarily sequential
- Sequential lists (e.g., those that describe step-by-step procedures) appear as numbered lists.
NOTE
This symbol indicates something of special interest or importance to the
reader. Failure to read the note will not result in physical harm to the
reader, equipment or data. CAUTION
This symbol indicates that if this information is ignored, the possibility of
data or material damage may occur.
WARNING!
This symbol indicates that if this information is ignored the possibility that
serious personal injury may occur.
Item Checklist
Standard Items
Optional Items
System View
Front View
No. | Description |
---|---|
1 | Speaker |
2 | Trigger key (middle) |
3 | Power On/Off |
4 | 2D scanner |
5 | Trigger key (right) |
6 | Full HD P-CAP multi-touch screen |
7 | Mic |
8 | Battery status indicator |
Rear View
No. | Description |
---|---|
9 | MSR/RFID/Fingerprint/i Button dummy cover |
10 | Hand strap |
11 | 5MP AF camera |
12 | Trigger key (left) |
13 | DC-in |
14 | Should strap screw |
15 | Docking connector |
16 | USB type C |
Specification
System | M276 | M278 |
---|---|---|
Motherboard | F63 | F12 |
CPU
| Whiskey Lake Celeron 4305U| SNM758L-3308
(SnapDragon450)
| Elkhart Lake J6412| Whiskey Lake Celeron 4305U| Whiskey Lake Core i3-8145U|
SNM758L-3308 (SnapDragon450| Elkhart Lake J6412
System memory| DDR4 4GB| LPDDR3 3GB| DDR4 8GB| DDR4 4GB| DDR4 8GB| LPDDR3 3GB|
DDR4 8GB
Flash memory| 128G eMMC| 32G eMMC| 128G eMMC| 128G eMMC| 32G eMMC| 128G eMMC
LCD Touch Panel
LCD size| 11.6″| 13.3″
Brightness| 250 nits
Resolution| 19201080
Wireless Networking
Wireless LAN + BLE| 802.11 a/b/g/n/ac 2.4G/5GHz, BLE
Expansion I/O Ports
USB type-C| 1 (data transfer only)
Mic| 1
DC| 1
POGO I/O port| 16 Pin POGO
2D scanner| 1 (Option : Honeywell 3601)
Extension Port
Kits| 1 MSR / I Button / Fingerprint / RFID (either one)
Full I/O Stand (Optional)
I/O ports| Full Function| Full Function
Front
USB2.0 x 1 (Type A)
Rear
COM(RS232, 0V/5V/12V) x 2 LAN(RJ-45) x 1
USB2.0 x 0 (Type A) USB3.0 x 2 (Type A)
Type C x 1 (data only 3.0) PUSB 24V x 1
PUSB 12V x 1
Cash drawer x 1| Front
USB2.0 x 1 (Type A)
Rear
COM(RS232, 0V/5V/12V) x 2 LAN(RJ-45) x 1
USB2.0 x 0 (Type A) USB3.0 x 2 (Type A)
Type C x 1 (data only 3.0) PUSB 24V x 1
PUSB 12V x 1
Cash drawer x 1
Normal| Normal
Front
USB2.0 x 1 (Type A)
Rear
COM(RS232, 0V/5V/12V) x 2 LAN(RJ-45) x 1
USB2.0 x 2 (Type A) USB3.0 x 0 (Type A)
Type C x 1 (data only 2.0) PUSB 24V x 1
PUSB 12V x 1
Cash drawer x 1| Front
USB2.0 x 1 (Type A) Rear
COM(RS232, 0V/5V/12V) x 2 LAN(RJ-45) x 1USB2.0 x 2 (Type A) USB3.0 x 0
(Type A)
Type C x 1 (data only 2.0) PUSB 24V x 1
PUSB 12V x 1
Cash drawer x 1
System| M276| M278
---|---|---
Motherboard| F63| F12| F33| F63| F12| F33
Audio
Speaker| 1x 1W
Control / Indicator
Sensor| G-sensor
LED indicator| 1
Camera (Optional)
Rear camera| 5MP
Battery & Power
Battery| 7268mAh, 3.85V (Max. Charging Power=27.98Wh)
Hot swap battery| N/A
Power adapter| Tablet only – 12V/36W
Peripherals
Hand strap| 1
Certificate
EMC & Safety| FCC Class B, CE Mark Class B, LVD, RF
Environment
Operating temperature (none charging mode)| 0°C ~ 40°C (32°F ~104 °F)
Operating temperature (charging mode)| 0°C ~ 35°C (32 °F ~ +95 °F)
Storage temperature| -10°C ~ 45°C (14°F ~ 114°F)
Humidity| 20% – 80% RH non-condensing
Size
Dimension| 276 x 179 x 15.4 mm| 312.5 x 200 x 15.4 mm
Weight| 800g| 980g
OS Support
Windows| Windows10_20 19X64| N/A| Windows 10_21H2X64| Windows10_20 19X64| N/A|
Windows 10_21H2X64
Android| N/A| 9| N/A| N/A| 9| N/A
Getting Started
Power On/Off the System
- Press the power button for 2 seconds to turn on the system and press it for 6 seconds to turn off the system. Note: For best touch performance, remove the protective plastic overlay from the touch screen by peeling it away from one of the corners. Be sure to use a soft pointing device or finger tip to avoid scratching the screen during normal use.
Installing the Peripheral Kits
- Remove the dummy cover first. Remove the rubber pads (x2) and screws (x2)to release the top cover of the MSR module.
- Connect the cable to the connector on the system side. Then position the MSR module over the system as shown and fasten with the screws (x2). Finally place the top cover of the MSR module back. NOTE: The variety of peripheral kits like RFID/Fingerprint and I Button all follow the same installation method.
Using the Premium Docking Station
The premium docking station provides additional connectors and interfaces to support other devices and is also designed to allow the tablet to charge its battery via the dock.
-
To use the premium docking station, firstly connect the AC adapter to the DC-in input and connect the other end to the power outlet. Always plug in the AC adapter first to enable the locking/unlocking function.
You can also charge the battery via the optional 36W power adapter. Plug in the AC adapter cable directly into the connector located on the bottom right of the tablet. Then plug the other end to the AC outlet.
Attaching the tablet to the dock -
After plugging in the AC adapter to the power outlet, align the rear of the tablet with the top of the docking station, and place the tablet onto the dock. The tablet automatically locks to the dock when attached.
Removing the tablet from the dock -
Press the lock release button on the front of the docking station, and then lift the tablet off the dock.
NOTE: The tablet will be locked again if it is not removed from the dock after pressing the release button in 10 seconds.
The light on the dock’s lock release button indicates the locking status:
Blue – The tablet is locked
Green – The tablet is unlocked and can be removed.
Adjusting the tablet angle -
The premium docking station offers adjustment of viewing angle. You can tilt and swivel the tablet to set it to angle you preferred. The tilt angle can be set between 0° and 17°and the swivel angle can be set to 180° in either direction.
Attaching the Shoulder Strap
- Align and attach the shoulder strap to the tablet as shown and fasten the screws (x2) to secure it.
Configuration
COM Port Power
- Double click P-2DK10_ConfigTool.exe to run the setup tool.
- By default, both left and right COM port power are 0V. To change the default COM port power, select power and tap on Write COM Port Power to confirm. L/R COM port power can be set to different voltage individually, e.g., L:5V and R:12V.
Cash Drawer COM Port
- Click on New Port COM and enter 7 in the column.
- Tap on Set COM Port to confirm.
- Double click P-2DK10_ConfigTool.exe to run the setup tool.
- By default, both left and right COM port power are 0V. To change the default COM port power, select power and tap on Write COM Port Power to confirm.
- You can check the current setup condition by tapping on Read. If the device is not connected or the setup process hasn’t been completed yet, the Read /Write column will be highlighted.
USB over IP
- The Premium Docking Station P-2DK10 is designed with the feature of USB over IP that offers a convenient way to extend and share a USB device over long distance, and it also works with multiple tablet-dock pairs.
- When the tablet docks on the premium docking station P-2DK10, it is connected via LAN and will be automatically switched to WLAN while releasing from the docking station.
- Prior to installing the USB client software, ensure that the WLAN is on the same network.
-
In the Virtual Here folder, double click Install.bat to install the software. Once it is completely installed, the program will launch automatically after you log into the computer.
To remove the software, double click Uninstall.bat -
Double click P-2DK10_ConfigTool.exe to run the setup tool.
-
Specify the MAC address of the server in your Virtual Here by clicking on StepIP. The process may take up to 2~3 minutes showing the message Set IP….If all was done correctly, a popup window should appear indicating Set IP success!
-
The default setting of the system is Mode 1: POS Mode. To change the de- fault mode, select Mode 2: All USB over IP and tap on Write USB over IP.
-
Restart your computer to confirm changes.
- Always dock your tablet on the premium docking station before changing the Mode.
- USB over IP Mode is not recommended for the use of mass storage devices.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>