TROTEC HG125 Hygrostat User Manual

June 5, 2024
TROTEC

TROTEC HG125 Hygrostat User Manual
TROTEC HG125 Hygrostat

Notes regarding the operating manual

Legal notice

This release replaces all previous versions. No part of this publication may be reproduced without written permission from Trotec GmbH. The same applies for electronically processing, duplicating or spreading the publication. Subject to technical changes. All rights reserved. Trademarks are used without guarantee that they may be used freely and primarily following the spelling of the manufacturer. Product names are registered.
Changes to construction in the interests of constant improvements to the product, as well as changes to the shape and colour are reserved.
The scope of delivery may vary from product images. This document was created with all due care.
Trotec GmbH accepts no liability whatsoever for possible mistakes or omissions.

© Trotec GmbH

Symbols

The current version of the operating manual can be found at:
Symbol HG 125 electronic  QR code

ESD protection instructions

The devices contain components which can be damaged by the effects of electrical fields or by charge equalisation when touched.

The following safety measures must be observed when opening the device for maintenance or for modifying the connection:

  • Before opening the housing, establish potential equalisation between you and your environment.
  • Make sure that this potential equalisation is maintained when working while the housing is open.

Device description

Easy to install

  • 5 m cable length for remote probe
  • 2 potential-free switching outputs, configurable as NC or NO contacts
  • 2 nominal values and switching hystereses, independently configurable
  • Display of current relay switching states
  • 2 continuous signal outputs (0…10 V), for relative humidity and temperature
  • Pluggable and exchangeable calibrated measuring probe
  • Alternating display of relative humidity and temperature

Application

  • Detrimental influences
    Aggressive media containing solvents can cause measuring errors and failure, depending on the type and concentration. For instance, deposits forming a water repellent film on the sensor element (resin aerosols, paint aerosols, smoke substances etc.) are damaging.

Assembly

  • Position
    The place of assembly of the external sensor must be chosen so as to ensure a representative humidity and temperature measurement. Do not install near heat sources such as radiators, doors, window and outer walls.
    Avoid direct sunlight.

  • Connection
    The device is preconfigured and preassembled upon delivery. Any modifications of the hygrostat must be carried out by expert staff. The housing contains sensitive components. When opening the housing, observe the ESD protection instructions (see 01. ESD protection instructions). Supply lines to the device as well as the sensor cable must not be installed parallel to strong electromagnetic fields. In case of potential overvoltage, install appropriate overvoltage protection devices.

Dimension drawings

Dimension drawings

Opening the housing (schematic diagram)

Assembly

Dimension drawing of the cable sensor

Assembly

Configuration instructions

Operating mode

Configuration instructions

Configuration mode

Configuration instructions Configuration
instructions Configuration instructions Configuration
instructions

CONFIGURATION:

  1. Press black button for a long time (>3s): adopt modified value (display “Store”)
  2. Briefly (!) press black button: do not adopt the modified value (display “_ESC” = leave, return to operating mode)

If no setting or change is made over a longer period (approx. 30s), the menu will automatically return to operating mode via “_ESC”. All settings and changes previously made are not adopted in this case.

Setting of relays

Setting of relay 1 and 2 as NC contact (opener) or NO contact (closer).

DIP switch set to current measured value
< nominal value – switching hystereses / 2 > nominal value + switching

hystereses / 2
C (closer)| relay = open| relay = closed
O (opener)| relay = closed| relay = open

Setting of relays

Connection diagrams

Connection diagrams Connection
diagrams

Technical data

HG125Logo
610.000.2042

CE icon

2 x Relay output (R-RH) (R-T)
Analog output 1 Rel. Humidity (RH): 0….100%RH
Analog output2 Temperature (T): -30…+70°C

Technical data

Humidity (RH

Measuring range humidity output 0…100 % RH

Setting range relay 1 (RH)
default| 5…95 % RH
45 % RH
Setting range of switching hysteresis RH
default| 0.5…9 % RH
5 % RH (+/- 2.5 % RH)
Measurement uncertainty
10…90 % RH at 25°C max.
0…10 % RH and 90…100 % RH ( at 25 °C
Long term stability
Hysteresis
Typ. temperature influence at 25 °C| ≤ ±2 % RH
additionally
≤ ±0.2 % RH / % RH
≤ 0.5 % RH/a
≤ ±1 % RH
±0.05 % RH/K

Temperature (T)

Analog temperature output| -30…+70 °C
0…10 V
---|---
Measurement uncertainty at 23 °C| typ. ±0.2 K
Setting range relay 2 (T) default| -35 °C to +80 °C
-35 °C
Setting range of switching hysteresis T default| 0.1 °C to +10 °C
2 K (+/- 1 °C)

Electrical data

Switching outputs: 2 relay contacts, potential-free
Setting NC / NO contact default via DIP switch

NC contact (opener O)
Switching voltage relay contact| ≤ 48V DC / AC
Switching capacity| ≤ 60 W / 62.5 VA
Power factor| ≥ 0.9
Switching cycles (at Pmax)| > 105
Switching current| ≤ 2A
Continuous output rel. humidity| 0…10 V DC
Continuous output temperature| 0…10 V DC
Supply voltage| 15…30 V DC
13…26 V AC
Self-consumption| ≤ 30 mA
Applied standards| EN 61326-1

General data

Measuring medium| pressureless, non- condensing, non-
aggressive air
---|---
Operating temperature housing| -30…+80 °C
Operating temperature cable sensor| -40…+85 °C
Storage temperature| -40…+85 °C
Electrical contact of terminals
Wire cross-section of each terminal
Cable diameter
Surface-mounted cable Flush-mounted cable| max. 1.5 mm²
max. 1 x Ø 6.5 mm
or 2 x Ø 4.5 mm
see: User information on page 5
Type of protection of cable sensor with membrane filter ZE08 (standard equipment) with PTFE sinter filter ZE05 (optional)| IP30 IP65
Type of protection of housing| IP 30D
Protection class| III
Housing material| ABS
Housing colour| signal white
similar to RAL 9003
Digital display| 2-line

Note
The information contained herein reflects our current state of knowledge and is meant to provide information on our products and their possible applications. Thus, it is not intended to warrant specific properties of the products or their suitability for a particular application. Experience shows that the use of the devices covers a broad range including the most diverse conditions and loads. We cannot assess every individual case.
The customer or user must examine the suitability of the devices. Any existing industrial property rights must be taken into consideration. We guarantee perfect quality within the framework of our General Terms of Delivery. Subject to changes.

Optional accessories

Optional accessories

Adapter transformer HG 24 V
When using the hygrostat in combination with Trotec dehumidifiers with 4-pin DIN socket, the optionally available adapter transformer is required in addition.
Article no. 6.100.002.043

Trotec GmbH

Grebbener Str. 7 D52525 Heinsberg
+49 2452 962-400
+49 2452 962-200
info@trotec.com
www.trotec.com

Logo

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>