EIP LTD RF3500 Air Mover User Manual
- June 5, 2024
- EIP LTD
Table of Contents
RF3500 Air Mover
User Manual
Drawing : – TPC40
Issue : – 4
Date : – 30/11/16
UNPACKING
Remove your EIPL RF3500 from its packing carton and wrapping, and visually
inspect for any signs of transit damage. If there are any signs of damage, do
not operate your unit. Call your supplier immediately for advice. Do not
discard the packing for it will be useful for transporting your unit in the
future.
TRANSPORTATION
Do not drop or abuse your Air Mover during transit for the risk of damage to
both the motor and housing.
INTRODUCTION
The RF3500 should only be operated in the horizontal position and with the
unit standing on a firm and level floor. A flexible duct can be attached to
the either inlet or outlet to transport the air over long distances.
Connection to the RF3500 is done by using the quick release “belted cuff”,
unique to the EIPL RF3500.
OPERATING PROCEDURES
Connect the power cord to a grounded electrical outlet and press the power
switch to the ‘I’ position. If you have no power or hear any loud or abnormal
noises then consult your supplier.
Since the RF3500 has a considerably high suction power, always ensure that the
inlet grille is kept free of any obstruction.
To switch the unit off, press the power switch to the ‘O’ position and
disconnect from the electrical outlet.
ELECTRICAL CONNECTION
If the appliance is fitted with a plug for which your socket is unsuitable,
then it should be cut off and an appropriate plug fitted.
This appliance complies with the suppression requirements of the EEC direction
82/199/EEC as embodied in BS800:1988.
IMPORTANT:- The wires in this mains lead are colored in accordance with the
following code:-
Green/Yellow | Earth |
---|---|
Blue | Neutral |
Brown | Live |
Only 13amp fuses that are STA approved to BS1362 should be used. Fuse covers
must be refitted after the replacement of the fuse.
As the colors of the wires in the mains lead of this appliance may not
correspond with the colored markings identifying the terminals in your own
plug, proceed as follows:
The wire which is colored Green and Yellow must be connected to the terminal
in the plug which is marked with the letter E or by the Earth Symbol or
colored Green and Yellow. The wire which is colored blue must be connected to
the terminal in the plug which is marked with the letter N or colored Black.
The wire which is colored brown must be connected to the terminal which is
marked with the letter L or colored Red.
You must dispose of the nonrewireable plug once it has been removed from the
flexible cord. It is dangerous to attempt to insert the plug into any
electrical socket elsewhere in the house. If the flexible cord becomes damaged
it must be replaced by an identical cord.
SERVICE
This machine should be serviced by qualified EIPL personnel or other persons
having technical competence and following the instructions in the manual.
TECHNICAL SPECIFICATIONS
RF3500 | 110V/60Hz/1 PH |
---|---|
Height | 18.7” |
Width | 16.2” |
Depth | 15.6” |
Weight | 23.2lbs |
Power (W) | 600 |
Max running current | 6A |
Airflow (M3/Hr) | 3600 |
IF YOUR RF3500 FAILS TO OPERATE
- Check that the plug is fully pushed into the socket and is switched on.
- Check with some other electrical device that the wall socket is “live”. If it is not, contact a qualified electrician.
Should the above remedies not work, then disconnect from the mains. Contact
your supplier. DO NOT attempt to repair the unit or unscrew the outer casing.
WARNINGS
- This appliance can be used by children from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the application in a safe way and understand the hazards involved.
- Children shall not play with the appliance.
- This machine should be serviced by qualified Ebac personnel or other persons having technical competence in servicing refrigeration equipment following the instructions in the Ebac service manual.
- Ebac service manuals and spares lists are available upon request by contacting your local Ebac distributor.
- Never operate the unit in a bathroom or swimming pool area
- Do not use the machine if the power cord or case is damaged.
- Do not poke objects into any of the grilles on the machine.
- Do not cover or obstruct the air inlet or outlet.
- This machine complies with the electromagnetic compatibility 1992 regulations.
- This machine has been manufactured in the United Kingdom.
- This appliance can be used by children from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the application in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
- Ensure that the fan is switched off from the supply mains before removing the guard.
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons in order to avoid hazards.
UK Head Office
Ebac Industrial Products Ltd
St Helens Trading Estate
Bishop Auckland
County Durham
DL14 9AD
Tel: +44 (0) 1388 664400
Fax: +44 (0) 1388 662590
www.eipl.co.uk
sales@eipl.co.uk| American Sales Office
Ebac Industrial Products Inc
700 Thimble Shoals Blvd.
Suite 109, Newport News
Virginia, 23606-2575
USA
Tel: +01 757 873 6800
Fax: +01 757 873 3632
www.ebacusa.com
sales@ebacusa.com| German Sales Office
Ebac Industrial Products Ltd.Gartenfelder Str. 29-37
Gebäude 35
D-13599, Berlin
Germany
Tel: +49 3043 557241
Fax: +49 3043 557240
www.eip-ltd.de
sales@eip-ltd.de
| Get In Touch| Our Address
---|---|---
Call: 0845 6880112
Email: info@adremit.co.uk| Prevent, Adremit
Limited, Unit 5a, Commercial Yard, Settle, North Yorkshire, BD24 9RH
References
- EIP Group - Industrial Dehumidifiers
- EIP Group - Industrial Dehumidifiers
- EIPL - Industrial Dehumidifiers
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>