STELPRO ST302 Programmable Electronic Thermostat for Baseboards and Convectors Owner’s Manual

June 5, 2024
StelPro

STELPRO LOGO ST302 Programmable Electronic Thermostat for
Baseboards and Convectors
Owner’s Manual
ST302P ST402P
1-844-STELPRO
WWW.STELPRO.COM 

IMPORTANT INSTRUCTIONS

THE THERMOSTAT MUST BE INSTALLED BY A CERTIFIED ELECTRICIAN.
Connect the thermostat to a 120 to 240 VAC power source ONLY and comply with load limits.
WARNING – HIGH VOLTAGE. Turn off the power supply before installation and maintenance. Leave at least 12 in. (30 cm) clearance around the thermostat to ensure that it is properly vented.
SAVE THESE INSTRUCTIONS

TECHNICAL SPECIFICATIONS

PRODUCT CODE SUPPLY VOLTAGE LOAD AT 120 V LOAD AT 240 V
VOLTS WATTS WATTS
ST302P 120-240 150-1500 300-3000
ST402P 120-240 150-2000 300-4000
Load control type Resistive
--- ---
Frequency 60 Hz
Storage temperature -40°C to 50°C (-40°F to 122°F)
Operating temperature -20°C to 50°C (-4°F to 122°F).
Humidity 5 % to 98 % without condensation
Action Type 1. Y
Pollution degree 2
Software Class A
Rated impulse voltage Category II overvoltage (1500 V)

Independently mounted control for surface mounting
The thermistor used as a sensor carries a no-load current
Overload protection device external to the control: circuit breaker (refer to local electrical code)

BEFORE YOU GET STARTED

  • The box contains one (1) thermostat with a mounting plate, two (2) mounting screws, two (2) twist-on wire connectors, and one (1) owner’s manual.
  • To install this thermostat, you will need a #2 Phillips screwdriver.
  • Install your thermostat about 5 ft (1.5 m) from the floor on an inside wall facing the heating system.

INSTALLATION

1. ATTACH THE MOUNTING PLATE
WARNING:
Turn off the power supply.

  1. Loosen the screw [A] at the top of the thermostat without removing it.

  2. Separate the mounting plate from the thermostat. Pull the top of the plate and rotate.
    STELPRO ST302P Programmable Electronic Thermostat -
INSTALLATION

  3. Take the power wires [B] out of the junction box and run them through the large opening in the center of the mounting plate [C].

  4. Using the two (2) mounting screws provided [D] , attach the thermostat mounting plate to the junction box. The plate can be centered on the junction box or shifted to the left or right.
    STELPRO ST302P Programmable Electronic INSTALLATION1

2. CONNECT THE POWER SUPPLY WIRES

WARNING: Incorrectly connected electrical wires could result in a fire hazard.

  1. Complete the thermostat’s electrical connection according to the diagram below. Tighten the wires securely in the supplied wire connectors.
  2. Push the wires and connectors into the electrical box.

NOTE: If the electrical wires are aluminum, use CO/ALR connectors instead (not supplied).

STELPRO ST302P Programmable Electronic - SUPPLY WIRES

The diagram shows a 240 V power supply.
3. ATTACH THE THERMOSTAT

  1. Using the alignment guide, hook the bottom [A] of the thermostat into the bottom of the plate. Be sure not to jam the wires between the thermostat and mounting plate.

  2. Rotate the thermostat upwards and attach it to the top hook of the mounting plate.
    STELPRO ST302P Programmable Electronic - THERMOSTAT

  3. Tighten the screw at the top of the thermostat [B] to hold it in place securely.

  4. Restore the power at the circuit breaker.

STELPRO ST302P Programmable Electronic - THERMOSTAT1

NOTE: If you need to remove the thermostat, follow step 1 in section 1, then use a straight screwdriver to unhook it from the top of the mounting plate.

INTERFACE

This thermostat is PROGRAMMABLE. PROGRAMMABLE mode allows you to define the setpoint temperature according to the time of day and day of the week. (See the INITIAL SETTINGS AND PROGRAMMING section.) You can also use this thermostat in MANUAL mode, i.e. the setpoint temperature will be constant.
Touch the keypad once to activate the backlight, then you can make changes.

STELPRO ST302P Programmable Electronic - INTERFACE

INITIAL SETTINGS AND PROGRAMMING

To begin with, follow the on-screen instructions to adjust your thermostat’s settings. Press or to change your selection and to confirm.
• Language: FRA / ENG (Français / English)
• Temperature format: °C / °F (Celsius / Fahrenheit)
• Operation mode: PROG / MANUAL (Programmable / Manual).
If you selected MANUAL mode, your thermostat is now ready to use!
If you selected PROGRAMMABLE mode, configure the following settings:

  • Date and time
  • Automatic daylight savings time switchover: DST Y / DST N (Daylight savings time Yes / Daylight savings time No)
  • Program setpoint temperatures: (Wake, Leave, Return, Sleep)
  • Monday to Friday program hours: [Mo-Fr] (Wake, Leave, Return, Sleep)
  • Saturday and Sunday program hours: [Sa-Su] (Wake, Sleep)

The following table shows the default program values:
WEEKDAYS

WAKE LEAVE RETURN SLEEP
6:00 AM 8:00 AM 4:00 PM 10:00 PM
21 °C / 70 °F 16 °C / 61 °F 21 °C / 70 °F 17 °C / 63 °F

WEEKEND DAYS

WAKE SLEEP
7:00 AM 11:00 PM
21 °C / 70 °F 17 °C / 63 °F

FEATURES

KEY FEATURES

  1. Press or once to lower or raise the setpoint temperature by 0.5 °C / 1 °F. If you are in PROGRAMMABLE mode, the setpoint change will be considered as a temporary override to the programming. The thermostat will return to PROGRAMMABLE mode when the next program begins.
    To cancel the override and return to PROGRAMMABLE mode, press .

  2. Press once to switch from MANUAL to PROGRAMMABLE mode and vice versa.

  3. If PROGRAMMABLE mode is selected, press twice to go to the next program.

ADVANCED MENU ACCESS AND USE

  1. Press and hold for 3 seconds to access the thermostat’s advanced menus.
  2. Press or change your selection.
  3. Press to confirm your selection and proceed to the next menu.
  4. Press and hold for 3 seconds to exit the advanced menus.

ADVANCED MENU LIST

  • Language: FRA / ENG (Français / English)
    • Temperature format: °C / °F (Celsius / Fahrenheit)
    • Operation mode: PROG / MANUAL (Programmable / Manual.
    When the PROGRAMMABLE mode is selected, you can change the following settings:
    • Date and time
    • Automatic daylight savings time switchover: DST Y / DST N (Daylight savings time Yes / Daylight savings time No)
    • Program setpoint temperatures: (Wake, Leave, Return, Sleep)
    • Monday to Friday program hours: [Mo-Fr] (Wake, Leave, Return, Sleep)
    • Saturday and Sunday program hours [Sa-Su] (Wake, Sleep)

  • Keypad lock: LOCK / UNLOCK (Lock keypad / Unlock keypad)

  • Reset thermostat to default values: RST N / RST Y (No / Yes)

USING THE TECHNICAL MENUS:

  1. Press for 10 seconds to access the thermostat’s technical menus (the advanced menu will appear after 3 seconds but continue to hold for another 7 seconds).
  2. Use ou to change your selection.
  3. Press to confirm your selection and continue to the next menu.
  4. Press for 3 seconds to exit the thermostat’s technical menus.

TECHNICAL MENU LIST

  • t1: Maximum room temperature setpoint limit (5°C to 30°C / 41°F to 86°F). The default setting is 30°C.

  • t2: Minimum room temperature setpoint limit (5°C to 30°C / 41°F to 86°F). The default setting is 5°C.
    NOTE: The maximum setpoint limit must be higher than the minimum setpoint limit, and the minimum setpoint limit must be lower than the maximum setpoint limit.

  • t3: Year of production

  • t4: Month of production

  • t5: Identification number

  • t6: Software version

  • t7: Thermostat control code

STELPRO LIMITED WARRANTY

Limited three-year warranty. See details on www.stelpro.com.

STELPRO LOGO1-844-STELPRO
www.stelpro.com
STELPRO DESIGN INC.
Saint-Bruno-de-Montarville, Québec,
Canada,
J3V 6L7
INS-ST302-402P-0421
560-000027

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

StelPro User Manuals

Related Manuals