Altronix eBridge100TM IP and PoE PoE+ Over Coax Hardened Transceiver Installation Guide

June 4, 2024
Altronix

Bridge100TM
IP and PoE/PoE+ Over Coax
Hardened Transceiver
Installation Guide

Overview:

Altronix eBridge100TM EoC hardened transceiver transmits data at 100Mbps, Full Duplex over Coax cable to a paired eBridge receiver and provides power in a PoE/PoE+ compliant format to an enabled device/camera. The bridge receiver is available in various options and is powered by external midspan or endspan. The receiver passes PoE/ PoE+ power over the same coax cable to the eBridge100TM transceiver, which, in turn, passes this power to an enabled IP camera/device. These plug-and-play units facilitate a cost-effective, simple way to replace legacy analog products with new IP devices over existing coax up to 300m. When paired with the eBridge100RM EoC Receiver, the eBridge100TM will pass 100Mbps full duplex data and PoE/PoE+ over CAT5e (or higher) up to 500m.

Features:

Agency Listings:

  • UL/cUL Listed for Information
    Technology Equipment (UL 60950-1).

  • CE European Conformity.

  • C-Tick compliant.

Compatible Receivers:

  • eBridge100RM, eBridge400PCRM,
    eBridge800PCRM, and eBridge1600PCRM.

  •  eBridge800E.
    Visit www.altronix.com for the latest compatibility list.

Input:

  • Operating power provided by PSE (power sourcing equipment).
  • Current draw: 1.5W.
  • PoE compliant to IEEE 802.3af (15W) and PoE+ compliant to IEEE 802.3at (30W) from eBridge receivers.*

Coax link:

  • Throughput is rated to pass 100Mbps of data at distances up to 300m. (Maximum Length of Coax Type vs. Camera Power/PoE Class, pg. 4) for power delivery.
  • Connectivity: BNC, RG-59/U, or similar.

CAT5e or Higher from eBridge100RM:

  • Distance: up to 500m @ 100Mbps.
    (Maximum Length of Coax or CAT5 Type vs.
    Camera Power/PoE Class, pg. 4) for power delivery.

LED Indicators:

  • Green – PoE ON (by respective RJ45 jack).
  • Yellow and Green LED (RJ45) –
    IP Link status, 10/100Base-T/active.

Environmental:

  • Operating Temperature:
    For 15W: – 40ºC to 75ºC (– 40ºF to 167ºF).
    For 25W: – 40ºC to 60ºC (– 40ºF to 140ºF).
    For 30W: – 40ºC to 49ºC (– 40ºF to 120.2ºF).

  • Storage Temperature:
    – 40ºC to 75ºC (– 40ºF to 167ºF).

  • Humidity: 20 to 85%, non-condensing.

Functions:

  • Auto detection and protection of legacy non-PoE cameras/devices.

Applications:

  • Retrofit digital IP cameras in an analog CCTV installation.
  • Works with Megapixel, HD720, HD1080, and VGA (SD) cameras (see a note, pg. 2).
  • Extend Network link distance in an industrial environment over 610m (see a note, pg. 2).
  • Upgrade deployed CCTV Coax to a digital network in Retail, Casinos, Airports, Schools, Hospitals, etc.

Mechanical:

  • Dimensions (W x L x H approx.): 3.5” x 4.375” x 1” (88.9mm x 111.1mm x 25.4mm).

Installation Instructions:

Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction. Wiring should be UL Listed and/or Recognized wire suitable for the application. eBridge100TM is not intended to be connected to outside plant leads and should be installed indoors within the protected premises. eBridge100TM is intended for indoor use only.

  1. Secure unit to the desired mounting surface with a proper fastening device utilizing the case mounting hole (Fig. 2a, pg. 3). Unit should be mounted in proximity of camera/device.
  2. Connect structured cable from IP camera/device to RJ45 jack marked [PoE Out] (Figs. 2, 3, pg. 3). 3. Coax: Connect Coax cable from eBridge receiver (eBridge100RM, eBridge400PCRM, eBridge800PCRM, eBridge1600PCRM or eBridge800E) to BNC connector marked [Coax] (Figs. 2, 3, pg.
  3. CAT5 or higher (must use eBridge100RM receiver): Connect CAT5e or higher to the connector marked [RJ45 IN] (Fig. 2, pg. 3).

Note: eBridge100TM is designed to accommodate Megapixel, HD720, HD1080 and VGA (SD) cameras. It is important to note that some high resolution and high frame rate cameras may demand faster headend processing ability, such as a PC graphics card to present a quality image. If the headend processing equipment is insufficient in speed, the image may show pixelation and latency. It is advisable to pretest the system if unsure. Alternatively, frame rate and resolution may be reduced to accommodate system equipment.

Technical Specifications:

Parameter Description
Connections BNC for Coax link. RJ45 for extended Ethernet link.
Input Power Requirements PoE compliant to IEEE 802.3af (15W) and PoE+

compliant to IEEE 802.3at (30W) from eBridge100RM,
eBridge400/800/1600PCRM or eBridge8E.
Indicators| Yellow (RJ45 connector): On-Link,
Off – No Link,
Blinking – Activity.
Green (RJ45 connector): On – 100Base-TX,
Off – 10Base-T.
Green: PoE Active.
Environmental Conditions| Operating Ambient Temperature: UL60950-1
Bridget 00TM: For 15W: — 40°C to 75°C (— 40°F to 167°F).
For 25W: — 40°C to 70°C (— 40°F to 158°F).
For 30W: — 40°C to 49°C (— 40°F to 120.2°F).
Storage Temperature: – 40°C to 75°C (— 40°F to 167°F).
Humidity: 20 to 85%, non-condensing.
Operating Altitude: -304.8 to 2,000m.
Regulatory Compliance| UL/cUL Listed for Information Technology Equipment (UL 60950-1).
CE European Conformity. C-Tick compliant.
Weights (approx.)| Product: 0.22 lb. (0.1 kg) I Shipping: 0.4 lb. (0.18 kg).

*Note: Caution: once a PoE connection is established between a receiver and eBridge100TM, disconnection from eBridge100TM will not disable the PoE output voltage on the receiver. Although eBridge100TM can be reconnected, caution should be taken not to connect the CAT5 or single UTP wiring from the receiver to any non-PoE device.Altronix eBridge100TM IP and PoE PoE Over
Coax Hardened Transceiver - fig

Maximum Length of Coax/CAT5 Type vs. Camera Power/PoE Class:

Camera Power/
PoE Class| RG59/U –
23AWG| RG59/U –
22AWG| RG59/U –
20AWG| RG59/U –
18AWG| RG6/U –
18AWG| CAT5 or
Higher
---|---|---|---|---|---|---
Max. Length (meters)
13W/0| 261| 336| 500| 500| 500| 500
4W/1| 500| 500| 500| 500| 500| 500
6.5W/2| 500| 500| 500| 500| 500| 500
13W/3| 261| 336| 500| 500| 500| 500
19W| 153| 198| 316| 500| 500| 305
25W| 119| 151| 240| 366| 366| 214

Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA
718-567-8181
fax: 718-567-9056
website: www.altronix.com
e-mail: info@altronix.com
Lifetime Warranty
IIeBridge100TM Rev. 111413 G20U
eBridge100TM Installation Guide

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Altronix User Manuals

Related Manuals