as Schwabe 18672 Master-Slave Socket Outlet Instruction Manual

June 5, 2024
as Schwabe

18672 Master-Slave Socket Outlet
Instruction Manual

**Master-Slave socket outlet

**

Art. 18672

Operating instructions

Technical description of digital Master-Slave

With the switching on/off of one single device, which is plugged into the master socket, all further appliances in the slave sockets can also be automatically switched on/off. For example, you can use a computer as a master device, which can embrace slave appliances in the automatic control such as, for example, monitor, printer, modem, etc.
The power consumption of the master device must be >5W in the energized condition and in the de-energized condition (standby operation) it must be <100W. Master can be max. 500W
The switching threshold of this model is automatically set by the push of a button.
If you temporarily do not require the master-slave function, you may activate the permanent mode for the slave sockets. The multiple sockets then act as if the master-slave function was not available.
The switching threshold saved, or the permanent mode, also remains if the master-slave multiple sockets is temporarily switched off at the main switch.

Setup

Automatic threshold switching setting:

  1. Switch on the master-slave multiple sockets at the main switch.
  2. Plug the master device into the master socket.
  3. Set the master device to standby mode, or switched off mode if this is not already done.
  4. On the master-slave module, keep the “Learn” button pressed for approx. 3 secs., until the “Slave on” lamp begins to flash.
  5. The “Slave on” lamp now flashes for approx. 5-10 secs. During this time, the standby current consumption of the master device is automatically determined and the switching threshold is saved
  6. When the lamp “Slave on” stops flashing, the setting process is finished. The master-slave function can now be used.

Permanent mode for the slave sockets:
Activation

  • Proceed to the automatic setting of the switching threshold.
  • During the time that the “Slave on” lamp flashes (Point 5), push the button “Learn” again for approx. 3 secs. The automatic switching threshold setting is finished and the permanent mode for the slave sockets is activated.

Deactivation

  • Simply carry out an automatic switching threshold setting again.

Technical data

Nominal voltage: 230V / 50Hz
Max. load: 16A (3500W) for master and for slave sockets together
Switching threshold range: 5W – 100W
Switching threshold adjustment: Automatic adjustment by push button (see

Setup)
 Permanent mode:| Activation by push button (see Setup)
Zero crossing detection:| Relay switching only during zero crossing time
Standby power:| <0,9W

as – Schwabe GmbH