BURG WACHTER secuENTRY easy plus 5651 Fingerprint Electronic Lock User Manual
- June 5, 2024
- BURG WACHTER
Table of Contents
BURG WACHTER secuENTRY easy plus 5651 Fingerprint Electronic Lock
Dear
customer,
Thank you very much for deciding on the secuENTRY easy plus electronic locking
system by BURG-WÄCHTER. This system has been developed and manufactured using
the latest technologies and meets high security requirements. The electronic
cylinder can be easily inserted without any drilling into any door prepared
for profile cylinder up to a door thickness of 119 mm (61 / 59, measured from
the centre of the for end screw) and is ideally suited for both new
installations and retrofitting. Besides this, you have diverse additional
options, e. g. on which identification medium shall be used. You can find out
more on the following pages. Remove the battery protection strip from the
inner knob in order to energize the cylinder.
Important:
Please read the entire operating instructions before you start programming.
We hope you enjoy your new locking system.
General information on secuENTRY easy plus
The secuENTRY easy plus is available in three equipment configurations:
- secuENTRY easy PINCODE
- secuENTRY easy FINGERPRINT
- secuENTRY easy plus PASSIVE TRANSPONDER
The keypad in the set versions secuENTRY easy plus PINCODE and secuENTRY easy plus FINGERPRINT is already registered in the cylinder.
Administrator code / QR code
Each secuENTRY easy plus set with keypad comes with three QR codes, which are
required for setting up the opening option via the BURG-WÄCHTER KeyApp as well
as for logging on and training a keypad or a cylinder and for firmware
updates. Without an associated keypad, opening media (user, active
transponder, passive transponder) can only be programmed into the cylinder via
the optional secuENTRY Windows PC software. The administrator code is also on
the QR code of the internal knob
(main knob). In secuENTRY easy plus PINCODE and secuENTRY easy plus
FINGERPRINT, the administrator code is set to 1 – 2 – 3 – 4 – 5 – 6 at the
factory. Please change the factory-set administrator code to an individual
code!
Attention!
If the administrator and/or QR code is lost, reprogramming or use of all
administrator functions is no longer possible. Please keep it in a safe place!
- Keypad (SN; MAC; AES; Type)
- Cylinder (SN; MAC; AES; ADM)
- Transponder (UID; BW; Type)
If you have purchased a secuENTRY easy plus PASSIVE TRANSPONDER, the number of the respective transponder is stored in the “Type” field.
Tip:
The QR code can also be scanned in electronic form or saved as a photo on a
secured data carrier.
The manufacturer accepts no liability for any injuries or damage that may
occur during installation or improper handling.
Additional functions available using the optional secuENTRY Software, for
example:
- User administration
- Assignment of authorizations
- History function
Optical signalling inner knob
The optical signal in form of an LED is incorporated in the knob on the
outside of the door. You receive the following information via this LED:
- 1 x short: Cylinder is engaging
- 2 x short: Cylinder is disengaging
- 3 x short: Transponder TAG detected, no opening authorization
- 4 x short: Permanent opening activated
- 1 x short, 1 × long, 2 sec. pause, repeat: Lock in programming mode
- 5 × short, 2 sec. pause, repeat at 20 sec.: Battery in the cylinder depleted
Optical signalling outer knob
The optical signal in form of an LED is incorporated in the knob on the
outside of the door. You receive the following information via this LED:
- 1 x short: Cylinder is engaging
- 2 x short: Cylinder is disengaging
- 3 x short: Transponder TAG detected, no opening authorization
- 4 x short: Permanent opening activated
- 1 x short, 1 × long, 2 sec. pause, repeat: Lock in programming mode
- 5 × short, 2 sec. pause, repeat at 20 sec.: Battery in the cylinder depleted
Technical details
Blocking times| After 3 x wrong
code is entered 1 minute, then always 3 minutes
---|---
Display| Can be set in 12 languages
Reliable **ambient conditions***| -15 °C / +50 °C / up to 95 % rel.
humidity
(non-condensing) The display can react slowly or darken under extreme temperature changes.
Protection class| Keypad protection class PINCODE IP65 Keypad
protection class Fingerprint IP55 Cylinder protection class IP65
Voltage supply| 2 x MIGNON LR6 AA ALKALINE for the keypad
2 x MIGNON LR6 AA ALKALINE for the inner knob 1 x CR 123A Lithium for the outer knob
Transmission power and frequency range:| Bluetooth Low Energy, Maximum Transmit Output Power 7,5dBm
Frequency usage range 2.402GHz … 2.483 GHz
Opening
Depending on the equipment variant, the secuENTRY easy plus set can be
operated via a 6-digit numerical code, the BURG-WÄCHTER Key App, with the
passive transponder, with the active transponder or fingerprint.
Opening with PIN code
- Switch on the keypad using the key
- Enter the 6-digit PIN code (factory setting “1-2-3-4-5-6”). “Please turn the rotary knob” appears in the display, and the LED integrated in the cylinder flashes once when the opening is successful.
- Turn the cylinder knob
Opening with Fingerprint
- Switch on the keypad using the key
- Move the programmed finger from the top to bottom centrally over the sensor. “Please turn the rotary knob” appears in the display, and the LED integrated in the cylinder flashes once when the opening is successful.
- Turn the cylinder knob
Opening with Passive transponder
- Hold the transponder at the front at a maximum distance of 1 cm from the cylinder knob. The LED which is integrated in the cylinder flashes once upon successful opening.
- Turn the cylinder knob
Please note that during the opening process with the Key App, the active or passive transponder, the keypad must not be switched on via the key beforehand!
Opening with Active transponder
- Briefly press the opening button x1 at a distance of max. 4 m from the secuENTRY easy plus cylinder knob. The LED which is integrated in the cylinder flashes once upon successful opening.
- Turn the cylinder knob
Open with the BURG-WÄCHTER Key App
- Hold your Smart Device in front of the cylinder knob and press the open button of the KeyApp.
- The LED integrated in the cylinder flashes once when the opening is successful.
- Turn the cylinder knob
BURG-WÄCHTER Key App
You can download the BURG-WÄCHTER Key App from the App Store or Google Play
Store. Simply enter the search term “secuENTRY” or “Key App”. Compatible with
Samsung Galaxy S4, S4 mini, S5 and S5 mini, S6, S6-Edge, S7, S7-Edge, S8,
S8Plus from Android 4.3 KitKat or 5.0 Lollipop, Apple iPhone 4S, 5, 5S, 6,
6Plus, 6S, 6S-Plus,7 and 7-Plus from iOS 10.3.2. Please check at:
www.burg.biz/secuentry/description if other smartphones are compatible with
the app.
Package contents
secuENTRY easy plus PINCODE
General
The electronic cylinder is operated by entering a pin code. In addition, the
lock can be operated via the BURG-WÄCHTER KeyApp, passive and active
transponders.
Package contents
- QR-Code keypad
- Keypad
- Outer knob
- Fixing material 1 keypad
- Fixing material 2 keypads (adhesive pads)
- Rubber cover
- Screwdriver Tx (size 8)
- For end screw
- Allen key (size 3)
- Two QR-Codes per cylinder
- Cylinder
- Wall mounting plate
- Privacy film
secuENTRY easy plus FINGERPRINT
General
Up to 24 fingers can be programmed with the secuENTRY fingerprint keypad. The
users are created separately (USER.xxxx FP). In addition, the lock can be
operated via a pin code, the Burg-Wächter Key app or transponder.
Package contents
-
QR-Code keypad
-
Keypad
-
Outer knob
-
Fixing material 1 keypad
-
Fixing material 2 keypads
(adhesive pads) -
Rubber cover
-
Screwdriver Tx (size 8
-
For end screw
-
Allen key (size 3)
-
QR-Code cylinder
-
Cylinder
-
Wall mounting plate
-
Privacy film
Attention!
The fingerprint sensor must not be cleaned with detergents. Please use a
slightly moist cloth for this purpose.
Functions
- Total number of users: up to 50 of which number of fingerprints: up to 24
secuENTRY easy plus Passive transponder
General
The electronic cylinder is operated via a passive transponder. Additional
transponders can be registered via the secuENTRY software or a keypad.
Package contents
- 3 Outer knob
- 6 Rubber cover
- 7 Screwdriver Tx (size 8) 8 For end screw
- 9 Allen key (size 3)
- 10 QR-Code cylinder
- 11 Cylinder
Schematic representation of menu functions
When the “Func:M” symbol is displayed, the menu can be reached by pressing the
“Function” key. In the menu, you then have a scroll function using keys 1 and
2 to navigate through the structure. You reach the next menu level using the
(Enter) key.
Attention!
The menu structure may vary depending on the software version of the keypad.
Setting up menu structure
- Code Change menu Language menu Administrator menu
- Create User menu
- Create: Code
- Create: sE key
- Create: Transponder 1,2
- Create: Fingerprint
- Assign User menu
- Create: Code
- Create: sE key
- Create: Transponder 1,2
- Create: Fingerprint
- Delete menu
- Time Functions menu
- Setting the time 2,3
- Setting the date 2,3
- Setup menu
- Register
- Reorganize
- Transmission power
- Firmware update
- Display contrast
- Programming
- FP Reset 1,2 menu
- Info menu
- EE version and serial number info
- AE version and serial number info
- Running time info
- Opening counter info
- Start-up date info
Description of the menu structure
The functions for the products ENTRY Pincode and ENTRY Fingerprint are
described below.
Change code menu
Changing the administrator code as well as the user code
-
Switch on the keypad using the key
-
Then press FUNC
“Menu / Code Change“ appears -
Confirm your selection using
-
Now you can use the keys 1 or 2 to scroll until the administrator/user is displayed whose code is supposed to be changed
-
Confirm with
-
Enter the previously valid (old) code and press
-
Enter the new code and confirm it with
-
Repeat your entry and confirm it again with .
Note:
When a cylinder is first started up, additional information on the current
date and time are requested:
- Enter the day (2 digits) and confirm your selection using
- Enter the month (2 digits) and confirm your selection using
- Enter the year (2 digits) and confirm your selection using
- Enter the hour (2 digits) and confirm your selection using
- Enter the minutes (2 digits) and confirm your selection using “Code change accomplished” is displayed after a correct entry
Language menu
Language setting
- Switch on the keypad using the key .
- Then press FUNC; “Menu / Code Change“ appears.
- Scroll using the 2 key until the Administrator menu appears
- Confirm with
- Use keys 1 or 2 to scroll until the desired language is displayed
- Confirm with
Administrator menu
Different submenus are available in the administrator menu.
Create a submenu user with code
- Switch on the keypad using the key.
- Then press FUNC; “Menu / Code Change“ appears.
- Scroll using the 2 key until the Administrator menu appears.
- Confirm with . The “Create User” menu item appears.
- Confirm with
- Scroll using the 2 key until “Create User: Code” appears
- Confirm with
- Enter the administrator code in order to acquire the authorization for programming.
- The next free memory cell is displayed (e.g. USER.0003)
- Enter the 6-digit code and confirm it 2 x using
- “Data has been saved” appears in the display
Create a submenu user with transponder
- Switch on the keypad using the key.
- Then press FUNC; “Menu / Code Change“ appears.
- Scroll using the 2 key until the Administrator menu appears.
- Confirm with . The “Create User” menu item appears.
- Confirm with
- Scroll using the 2 key until the “Create transponder“ appears
- Confirm with
- Enter the administrator code in order to acquire the authorization for programming.
- Hold the front of the transponder to be registered on the outer knob “USER.xxxx TR successfully created” appears in the display.
Create User with Fingerprint submenu
(Function only active with ENTRY Fingerprint and ENTRY KP FP keypad)
- Switch on the keypad using the key .
- Then press FUNC; “Menu / Code Change“ appears
- Scroll using the 2 key until the Administrator menu appears.
- Confirm with . The “Create User” menu item appears
- Confirm with
- Scroll with the key 2 until you reach the menu item “Create: Fingerprint” appears.
- Enter the administrator code in order to acquire the authorization for programming.
- “Program Finger” appears in the display.
- Move the finger to be registered several times centrally over the sensor (the number of moves is indicated on the display)
- “User_XXX_FP successfully programmed” appears in the display
Create User with sE key (active transponder) submenu:
- Switch on the keypad using the key .
- Then press FUNC – “Menu/Code Change” appears
- Scroll using the 2 key until the Administrator menu appears
- Confirm your selection using
- The “Create User” menu item appears.
- Confirm your selection using
- Scroll using the 2 key until “Create: “sE key” appears
- Confirm your selection using
- Enter the administrator code in order to acquire the authorisation for programming.
- Move the sE Key in the vicinity of the cylinder
- “USER.xxxx KY successfully created” appears in the display
Assigning a Code submenu
- Using this function, you have the option to subsequently assign a code to an already existing user. For this purpose, proceed as follows:
- Switch on the keypad using the key .
- Then press FUNC – “Menu/Code Change” appears
- Scroll using the 2 key until the Administrator menu appears
- Confirm your selection using
- Scroll using the 2 key until “Assign” appears
- Confirm your selection using
- Scroll using the 2 key until “Create User: Code” appears.
- Confirm your selection using
- Enter the administrator code in order to acquire the authorisation for programming.
- Scroll to the user to whom you want to assign a code and confirm using
- Enter a 6-digit code and confirm 2 × using
- “Data has been saved” appears in the display.
Submenu Time functions (only for Premium)
Time and date are set here
Assigning a transponder submenu
Using this function, you have the option to subsequently assign a transponder
to an already existing user. For this purpose, proceed as follows:
- Switch on the keypad using the key .
- Then press FUNC – “Menu/Code change” appears.
- Scroll using the 2 key until the Administrator menu appears.
- Confirm your selection using
- Scroll using the 2 key until “Assign” appears
- Confirm your selection using
- Scroll using the 2 key until “Create User: Transponder” appears.
- Confirm your selection using
- Enter the administrator code in order to acquire the authorisation for programming
- Scroll to the user to whom you want to assign a transponder and confirm using
- Hold the face of the transponder directly in front of the outer knob and confirm on the keypad using
- “User.xxxx.TR successfully created” appears in the display.
Assigning a finger submenu
Using this function, you have the option to subsequently assign a finger to an
already existing user. For this purpose, proceed as follows:
-
Switch on the keypad using the key .
-
Then press FUNC – “Menu/Code change” appears.
-
Scroll using the 2 key until the Administrator menu appears.
-
Confirm your selection using
-
Scroll using the 2 key until “Assign” appears
-
Confirm your selection using
-
Scroll using the 2 key until “Create User: Fingerprint” appears.
-
Confirm your selection using
-
Enter the administrator code in order to acquire the authorization for programming.
-
Scroll to the user to whom you want to assign a finger and confirm using
-
Move the finger to be registered several times centrally over the sensor (the number of moves is indicated on the display)
-
“User.xxxx.FP successfully created” appears in the display
Delete submenu
You have the option of deleting a user using this menu.
- Switch on the keypad using the key .
- Then press FUNC – “Menu/Code change” appears
- Scroll using the 2 key until the Administrator menu appears.
- Confirm your selection using
- Scroll using the 2 key until “Admin. “Set-up” Delete” appears
- Confirm your selection using
- Enter the administrator code in order to acquire the authorisation for programming
- Scroll to the identification medium that you want to delete and confirm 2x using
- “Data has been deleted” appears in the display.
Setting the time:
Not available in the standard function.
Setting the date:
Not available in the standard function.
Set-up submenu
General system settings
Register
After a replacement of the cylinder or the keypad, the two units have to be
newly aligned, so that they can resume communication.
Registration of a keypad
- Switch on the keypad using the key .
- Then press FUNC; “Menu / Code Change“ appears.
- Use keys 1 or 2 to scroll until you reach the “Administrator menu”
- Confirm with
- You can now use keys 1 or 2 to scroll until you reach the Admin. menu “Set-up”.
- Confirm with
- You can now use keys 1 or 2 to scroll until you reach the Admin. register Set-up menu.
- Confirm with
- Enter the valid admin. code of the unit to be programmed.
- “Data have been saved” is displayed after a successful registration.
Attention!
Please make sure that no other powered secuENTRY unit is placed within
direct reach of the device during installation of a new keypad or cylinder, as
by mistake such unit could be addressed instead of the intended one. When in
doubt, disconnect these units (remove batteries).
Reorganize
The use of this function is recommended when several users have been deleted.
- Switch on the keypad using the key .
- Then press FUNC; “Menu / Code Change“ appears
- Scroll using the 2 key until the Administrator menu appears
- Confirm with
- Scroll using the 2 key until the “Set-up” menu item appears
- Confirm with
- The menu item “Reorganize” appears.
- Confirm with
- Enter the administrator code in order to acquire the authorisation for programming
- “Reorganization is running” appears
FP reset submenu
(Function only active with ENTRY Fingerprint and ENTRY KP FP keypad)
Transmission power
The system or power consumption is optimized via the transmission power, and
the wireless range of the cylinder and the keypad are increased or reduced. As
delivered, a low transmission power is set in order to obtain the longest
possible battery life. The transmission power should only be increased if
repeated transmission problems should occur. The setting normally does not
have to be adjusted.
Firmware update
The secuENTRY keypad can be sequentially updated via the Burg-Wächter
ConfigApp. Please refer to the instructions for the ConfigApp for the exact
procedure.
Display contrast
- Switch on the keypad using the key .
- Then press FUNC – “Menu/Code Change” appears
- Scroll using the 2 key until the Administrator menu appears
- Confirm your selection using
- Scroll with the 2 key until “Setup” appears
- Confirm your selection using
- Scroll with the 2 key until “Display contrast” appears
- Confirm your selection using
- Select the desire contrast level using the 1 key (weaker) or the 2 key (stronger)
Programming
You can input into the keypad a data set created with the PC software via
Programming. The data set can be programmed using the PC software as well as
the secuENTRY ConfigApp.
- Switch on the keypad using the key .
- Then press FUNC – “Menu/Code change” appears.
- Scroll using the 2 key until the Administrator menu appears
- Confirm your selection using
- Scroll with the 2 key until “Set-up” appears
- Confirm your selection using
- Scroll with the 2 key until “Programming” appears
- Confirm your selection using
- Enter the administrator code in order to acquire the authorisation for programming
- The message “Start the file transmission“ appears in the display.
The keypad is now in programming mode and can be programmed using the PC
software or the ConfigApp.
All stored fingerprints are deleted; however, the corresponding users are
retained. Please select this menu and follow the instructions on the display
in case of repeated errors related to the use of fingerprints.
Info menu
Using this function, you can have several pieces of information of the system
displayed.
- Switch on the keypad using the key
- Then press FUNC; “Menu / Code Change“ appears
- Scroll using the 2 key until “Info menu” appears.
- Confirm with .
- Using the 1 or 2 key, you can scroll between the following information:
- Version and serial number of the keypad
- Version and serial number of the cylinder
- Operating time of the cylinder
- Opening procedures of the cylinder
- Start-up date and time of the cylinder
Note:
For security reasons, complete information about the cylinder is only
displayed after entering a valid administrator code.
secuENTRY easy plus cylinder assembly
The installation of the secuENTRY easy plus cylinder is explained below.
Please read these assembly instructions carefully before installation.
Note:
The base size of the cylinder is 30 mm per side. The cylinder has a special
latching system on the inside and an adaptor set is included for the outer
knob, which enables you to use the cylinder for door thicknesses up to 119 mm
(61/59, measured from the centre of the for end screw). No prior adjustment is
necessary. The appropriate screws are included with your set to fit the
adaptor lengths. When delivered, the cylinder inner knob is completely closed
(to the smallest door thickness). Before you insert the cylinder into the
door, you should adjust it to your door thickness. The inner knob is loosened
and fixed by means of an integrated grub screw in the rotary knob.
Attention! Never pull the inner knob completely off the shaft, as in this case
the electronics will be destroyed! The grub screw, which ensures the catch on
the shaft, may only be loosened slightly and always remains in the plastic
knob. The grub screw serves as a pull-off protection! Take care during
assembly. Avoid impacts or sudden movements. The lock should not be greased or
oiled. When installing the cylinder, proceed as follows:
-
Rough assessment of door thickness (incl. fittings)
-
Pull the outer knob off the shaft, move the inner knob over the locking system (distances 2.85 mm) to the desired dimension.
Schematic diagram Internal knob adjustment -
Depending on the door thickness, you have the option of fitting adaptors on the outside to improve the guidance of the emergency key.
The following combinations are possible:
| Adapter 1| Adapter 2
---|---|---
< 43| –| –
44 – 53| X| –
54 – 60| X| X
x: Selection
-: not planned
Tab. 1: Distance between for end screw / fitting [mm] on the outside and the
necessary adaptors.
-
Slide the secuENTRY easy cylinder from inside to outside through the mortise lock in the door and then tighten the for end screw.
-
Slide the inner knob on the shaft until you have reached the desired dimension. Please make sure that the distance between rotary knob and door fitting is at least 1 mm. Then fix the rotary knob using the grub screw.
-
Before fixing the outer knob, please check whether you want to insert the supplied cover for the profile cylinder cut-out. If so, remove the protective sheet and fix the cover panel onto the lock section.
-
Place the outer knob on the cylinder or the corresponding adaptor and tighten with the screw. Please refer to the table for the appropriate assignment and gradation.
Mounting external knob:
| |
---|---|---
M4x16| 7 mm| < = 32
M4x20| 11 mm| 32,5 – 36,0
M4x25| 16 mm| 36,5 – 41,0
M4x30| 21 mm| 41,5 – 46,0
M4x35| 26 mm| 46,5 – 51,0
M4x40| 31 mm| 51,5 – 56,0
M4x45| 36 mm| 56,5 – 61,0
Overview of screws and
hexagon adaptors
Fig. on a scale of 1:1
Adaptor ( L = length in mm)
-
Insert the CR123A lithium battery with the correct polarity (positive
pole forward). -
Slide the sleeve onto the outer knob and lock it in place.
-
Remove the battery safety strip on the inner knob.
-
The function test must be made with the door open.
Dimensions secuENTRY easy plus Cylinder
secuENTRY easy plus keypad assembly
The keypad is only included in the secuENTRY easy Pincode and secuENTRY easy
Fingerprint set.
Attention!
Please note that the keypad should not be attached to the door itself so that
no vibrations are transmitted when the door is shut. The membrane affixed to
the back of the keypad should not be sealed with glue and/or any other
substance under any circumstances! Exchange of air must also be possible after
the installation!
-
Determine the installation position for the keypad.
For this purpose, enter the opening code (e.g. PIN code, fingerprint…) at the desired mounting location and check whether the lock opens. -
Place the keypad accordingly.
If you decide on gluing the wall holder, please be sure to provide clean surfaces free from e.g. grease, oil and silicon films or any other impurities. Completely remove the protective film from the adhesive pads included, attach all the pads on the wall holder and then press firmly onto the desired position. When mounting in colder temperatures, please note that the full adhesive strength is achieved only after 72 hours at 20°C. Heat will accelerate the process (e.g. at 65°C; full adhesive strength is achieved in one hour). When gluing the holder plate on the colour sight protection film, the above described conditions relating to cleanliness of surfaces and firmness of the adhesive pad should be observed.
To facilitate a bubble-free application of the colour privacy film, please proceed as follows: -
Pour some water with a couple of drops of dishwashing detergent into a glass, stir it carefully free of foam, and then use it to gently moisten the surface on which the film is to be applied.
-
Pull off 1 cm of film at an edge of the white protective sheet and straighten it out. To change the position, lift the film carefully and attach it again.
-
Then wipe the adhesive film, e.g. with a plastic spatula, from the contact surface outward in the direction of the protective sheet that is still attached.
Attention! Do not use more liquid than absolutely necessary. -
Slide the keypad in from above until the locking latch of the base plate engages into the keypad housing. In this way, the keypad is protected against undesired removal.
-
Test the functioning of the unit with the door open. For this purpose, enter a valid opening code (e.g. PIN code, fingerprint,…) several times.
Cleaning instructions secuENTRY easy plus keypad
Dirt can barely adhere to the keypad surface due to the surface finish. Dusty
or dirty surfaces are wiped with a damped cloth. No alcohol-based detergents
(denatured alcohol, SIDOLIN® etc.) or aggressive detergents (acetone etc.) may
be used, as they can damage the surface or the sensor.
secuENTRY easy plus keypad battery change
-
Remove the case cover from below by loosening the 2 screws (Tx 8).
-
Pull the battery compartment lid downwards until it disengages and replace the batteries.
-
When inserting the new batteries, be careful to observe the correct polarity as indicated on the housing.
-
To close the battery compartment, first press the battery compartment lid close to the screw holes to make them slide into the recesses, then snap the bottom side into position by pressing on it.
-
Fasten the battery compartment lid with screws.
Attention!
Make sure that no moisture enters the keypad when replacing the battery.
Battery change knob (inside)
-
Using the grub screw supplied, loosen the top locking screw on the cylinder cover. It can be turned out only up to the opening of the cover and will not fall out.
-
Open the cover
-
Replace the batteries. Make sure the batteries are inserted with the correct polarity, indicated at the marked point on the housing.
-
Replace the cover.
Battery change outside knob
-
Press the notches back with the enclosed tool and pull off the knob sleeve.
-
Replace the battery and make sure the polarity is correct.
-
Carefully slide the knob sleeve back on
Please note:
Locking is only possible in one position!
Attention! Be careful not
to crush the cable. Make sure the O-ring is seated correctly.
Re-engage the knob sleeve.
Emergency key (outside)
function
Using the mechanical emergency key, you can provide access in case of failure
of the system.
-
Swing the emergency key open and then insert it into the indicted slot in the cover panel.
-
Turn the key 90 ° clockwise. If required, move the outer knob slightly to the right and left in order to release the mechanism.
-
Turn the outer knob. The lock opens at the latest when fully turned.
Turn the key to its initial position and take it out. To close the emergency lock, turn the knob twice fully in both directions.
Disassembling secuENTRY easy plus keypad from wall bracket
-
Remove the case cover from below by loosening the 2 screws (Tx 8).
-
Pull the battery compartment lid downwards until it disengages and replace the batteries.
-
Press the notch with a narrow tool (e.g. slotted screwdriver) downwards and pull the the keypad up.
Warranty
In order to deliver a flawless and high quality product to you and to better
assist you in case of service or repair, it is necessary that faulty or
defective devices along with the valid administrator code and the QR code(s)
be presented to your dealer together with the original documentation. In the
case of return shipments, due to your right of cancellation, all device parts
must furthermore be in their factory settings and the seal on the cylinder and
knob must be undamaged. Failure to comply with this will invalidate the
warranty.
Important information about our electronic locks
General information: please take care that the codes and the code carrier do
not fall into the wrong hands. Therefore, store the codes and code carrier in
a safe location so that these can only be accessed by authorised persons. In
case you lose a code or code carrier, the lock must be converted to a new code
/ code carrier, or replaced.
- The factory code must be changed as soon as the lock is commissioned.
- Simple codes that are easy to guess (e.g. 1, 2, 3, 4, 5, 6) must not be used.
- Personal data (e.g. birthday) or other data that may be concluded with knowledge of the code owner must not be used as a code.
- After changing the code, the lock must be checked several times with the safety door opened.
Disposal of the device
Dear Customer,
- please help us avoid unnecessary waste. Should you intend to dispose of this device at any time, please remember that many components of this device contain valuable materials that can be recycled. Please be aware that electrical and electronic equipment and batteries marked in this way must not be disposed of with household waste but collected separately. Please obtain information on the collecting points for electrical waste from the responsible authority of your city/municipality.
BURG-WÄCHTER KG hereby declares that this device complies with Directive 2014/53/EU, (RED) 2014/30/EU, (EMC) and 2011/65/EU (RoHS). The complete text of the EU Declaration of Conformity is available at the following Internet address: www.burg.biz
On interferences with Bluetooth devices
Bluetooth devices use the same frequency bandwidth (2.4 GHz) as WiFi devices.
Interferences can therefore arise that cause errors or interrupt
communication. If this occurs, unnecessary devices should be switched off.
Printing and typesetting errors as well as technical changes reserved.