EMPAVA 67AIS09 Freestanding Jetted Bathtub Instruction Manual

June 13, 2024
Empava

EMPAVA 67AIS09 Freestanding Jetted Bathtub Instruction Manual

EMPAVA 67AIS09 Freestanding Jetted Bathtub Instruction
Manual

Introduction

In order to use our products safely and effectively, please read this instruction carefully. Improper installation, operation and maintenance will cause the damage to the products and charge you extra repairing fee.
-Thank you for you to choose our massage bathtub series;
-We provide a lifetime warranty after-sale service, please fill warranty registration form accurately;
-If you need any help, please contact local distributor or our company directly;
-Our company reserve the right to change all the models listed in this instruction without prior notice;
-This instruction applies to the listed products as below.
-Because of the difference of the market requirement and individual custom product, please refer to the corresponding content in this instruction according to the product and its functions you choose. In this way, you can install and operate the product correctly.

  • In order to install the product correctly and safely by the installer, and you can use and maintain this product correctly and safely, please pay much attention to the warning sign as below
    The warning symbol’s meaning is as below:
    ⚠ Notice
    This symbol indicates that errant handling after disregarding this symbol could result in personal injury or property loss.

  • In order to install, use and maintain this product correctly and safely, please read and understand this instruction totally.

  • This instruction is a valuable source of product information to help the end user use the product safely and correctly.
    Please take good care of it and keep it from getting lost or soiled.

Preparation before installation

  • Make sure the place you install the bathtub is strong enough to bear the total weight of bathtub, maximum water volume and the user.
  • Waterproofing process must be made in the place of bathtub installed, or down stair will get damaged if water leaks.
  • The installed place must equip with water supply, power supply and drainage:
  • This product uses universal home power.

External circuitry need to equip with high sensitive and fast type leakage protection switch. (Induced current rating below 15MA, trip time should less than 0.1 second, rated current is above 30A.)
The product should be installed the grounding and electric leakage switch by qualified licensed electrician.

  • Please reserve the drainage hole~050mm, make sure the drainage pipes accord with the water valve.
  • User need to reserve the connectors of 1/2″ external thread cold/hot water hoses, which outstand the wall 30mm. It is suggested to install a valve in each pipe, the location of installed should be designed by user, which is convenient for maintaining.
  • As each bathroom or power and drain of each bathtub is slightly different, please place the bathtub according to the actual situation, the following illustration as a reference layout:

⚠ Notice The safe distance between power supply and water supply should be not less than 30cm.

Precautions for installation

EMPAVA 67AIS09 Freestanding Jetted Bathtub Instruction Manual - Precautions
for installation

Size chart

EMPAVA 67AIS09 Freestanding Jetted Bathtub Instruction Manual - Size
Chart

Installation instruction

• Inspection before installation

Although all our massage bathtub are water tested before they leave our factory there may be some loose of the hose connections due to the transport. We need water test the product before installation. The steps are as follow:

a. Place the tub on a flat surface in an area where it may be drained after testing. And adjust the feet to make the bathtub level;
b. Check if there is any loose of all the connection system;
c. Close the door, fill the tub with water to the overflow and allow standing for 1O minutes to inspect the tub for leaks;
d. Insert the plug, start all the function for few minutes (which includes the functions of massage, air bubble, heater and so on), inspect the tub completely any defect must be reported to your dealer/distributor prior to installation in order to have it covered under warranty.

• Adjust the leveling feet

According to different sizes bathtubs, we design about several leveling feet to adjust the bathtub. Please use a wrench or level ruler to level the bathtub.

EMPAVA 67AIS09 Freestanding Jetted Bathtub Instruction Manual - Adjust the
leveling feet

• How to connect the water?

For ease of use, our bathtub is equipped with stainless steel cold and hot water hoses (connector 0 1/2″). Please connect the cold and hot water hoses to the bathroom’s cold and hot water hoses accordingly.

Before connect bathtub water inlet pipe, first open water pipe for a period of time, then put filter screen to ensure that the debris will not enter the bathtub pipe. So that we can effectively extend the life of the fitting.

Insert the drain-pipe to the drain-hole on the floor, and then cover it with water retaining cover to prevent waste water spilling.

The red hose stands for hot water hose; the blue hose stands for A cold water hose;
Drain-pipe should be installed with slope above 1 :50;
Notice Do not hold the drain-pipe and cold/hot water hoses when moving the bathtub, and do not crash it with hard objects.

EMPAVA 67AIS09 Freestanding Jetted Bathtub Instruction Manual - Installation
instruction

Precautions for use

EMPAVA 67AIS09 Freestanding Jetted Bathtub Instruction Manual - Precautions
for use

Waist drum shape three-piece set faucet:

  • A. cold water switch (Marked with letter C)
  • B. Waterfall/sprinkling style transferable switch (Marked with icon)
  • C. hot water switch (Marked with letter H)

Multi-function hand held shower with back flow protector.

Rotate the shower head shell can adjust the water pattern as follow:
-inner water column
-middle water column
-external water column

Water jets use:
Turning the head of water jets up, down, left or right can adjust the angle of inflow.

Hydro massage flow rate control switch

Press the center button once to start the machine, and press repeatedly to shut it down.
Rotate hydro massage flow rate control switch clockwise, then the water column strength smaller; rotate the knob anticlockwise, then the water column strength stronger.
(Only for the model with hydro massage flow rate control switch)

Drainage
1.Manual drainage EMPAVA 67AIS09 Freestanding Jetted Bathtub Instruction
Manual - Manual drainage

Care and Maintenance

EMPAVA 67AIS09 Freestanding Jetted Bathtub Instruction Manual - Care and
Maintenance

Regular care of your bathtub will keep it clean and working at its best. Pump and pipe circulation systems should be flushed before first use and on a monthly basis when product is under normal use. Below are the recommended procedures for cleaning:

  1. Do not run the jet massage system dry;
  2. Fill the tub with hot water(about 40°C) 2-3 cm above the jets and add 2-3 teaspoons of low foaming detergent such as dishwashing machine detergent;
  3. Turn on all the functions and run for 10 minutes;
  4. Drain tub completely;
  5. Fill tub with cold water above jets;
  6. Turn on all the functions and run for 15 minutes;
  7. Drain tub completely;
  8. Cleaning the “suction cover”: Clean and remove any hair or lint from the suction cover. On a monthly basis, unscrew the suction cover and clean away any hair, lint or debris from the cover and housing, then remount the cover in place. Some suctions are not designed to be removed; only suctions that have screws on the cover, visible from the inside of the tub, can be removed.

⚠ Notice I Never operate the unit with the safety suction cover off

Troubleshooting Guide (Form two)

EMPAVA 67AIS09 Freestanding Jetted Bathtub Instruction Manual -
Troubleshooting guide

EMPAVA Logo

EMPAVA APPLIANCES INC.
15253 DON JULIAN RD CITY OF INDUSTRY,CA 91745
TEL:888-682-8882
WWW.EMPAVA.COM

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Empava User Manuals

Related Manuals