HAVIT HV1827 Luta Inground Light Instruction Manual
- June 5, 2024
- havit
Table of Contents
HAVIT HV1827 Luta Inground Light Instruction Manual
Product Specifications
Model No.
| HV1827W| HV1827C| HV1828W| HV1828C| HV1829W| HV1829C
---|---|---|---|---|---|---
Name|
Luta
Material
| 316 Stainless Steel cover + Aluminium body
Colour|
Cover – Stainless Steel Body – Black
IP Rating
| IP67
Input Voltage| 12v DC| 12v DC|
24v DC
Protection Class
| (Low Voltage)| (Low Voltage)| (Low Voltage)
Lamp Base|
Built In LED
Lamp Wattage
| 1x 3w| 1x 5w| 1x 20w
Colour Temp| 3000k| 5500k| 3000k| 5500k| 3000k|
5500k
Lumens
| 270lm| 300lm| 450lm| 500lm| 1600lm| 1800lm
CRI|
80
Wiring
| Parallel
Dimmable|
No
Warranty
|
3 Years Replacement*
Adequate Drainage
Descriptions
HV1827
-
Cutout with Canister
-
Cutout without Canister
HV1828
-
Cutout with Canister
-
Cutout without Canister
HV1829
-
Cutout with Canister
-
Cutout without Canister
Important Safety Issues
- This product must be installed by a qualified electrician according to AS/NZS
- Ensure all electrical mains are disconnected before any
- Modification of this product will void any
- Havit Lighting does not take responsibility for wrong installation, incorrect use, or use of installation material that does not belong to the
- When installing low voltage fittings, Voltage to fitting must be within +or- 5% of voltage required, if not within this allowance warranty will be
- Aluminium and 304SS fittings must not be installed within 5km of any salt water
- All 316 stainless steel fittings must have regular cleaning maintenance to avoid any tea staining from forming on (Warranty does not cover Tea Staining)
- All o-rings and seals must be in place correctly to maintain warranty
- When installing in ground light fittings, Adequate drainage must be allowed to prevent fittings from sitting in water for a long period of time, if no drainage is allowed, Warranty will be (See sample adequate drainage diagram for correct installation method.)
- This form may be updated at any time due to product improvements, please check online installation form for most current version
Steps for Installation
- Make sure that the electrical circuit is free of voltage (master switch off )
- Make a hole where fitting is to be placed using dimensions provided on line drawings, making sure adequate drainage is
- Insert canister, and ensure that the top is level with ground or Failure to do so will void warranty.
- Using an appropriate 12v DC LED Driver (24v DC Driver for HV1829 Models) – DO NOT CONNECT LIGHT FITTING DIRECTLY TO 240V
- Connect the cable – If more than one fitting installed, wiring must be done in
- Strip back the cable on both fitting and cable run and twist the positive cables Then connect neutral cables together
- Solder all joins using solder and either a heat gun or butane gas
- Cover connections using an adhesive lined heat shrink or gel cap to make connection Failure to do this will void warranty.
- Heat the heat shrink or crimp the gel cap making sure all connections are
- To adjust tilt, remove nuts on back of fitting and set aside, Remove cover and
- Adjust fitting to desired angle by pushing gently on either side until you reach desired
- Reinsert glass and
- Reattach the 4x nuts and tighten making sure the seals are still in place and screws are tight to avoid any water
- Insert fitting into Apply silicon around edge of fitting to prevent any water from getting inside to electrical connections.
- All connections must be carried out carefully, inspect all contacts before switching back on the electric circuit.
Must be installed by a licensed electrician
Warranty term & Condition*
Contact Details
143 Beauchamp Road
Matraville NSW 2036 Australia
Fax: 02 9666 8881
Tel: 02 9381 8300
Email: sales@havit.com.au