Product Guide (withdrawn product)
The QLogic 8Gb FC Host Bus Adapters are PCI Express 2.0 x8 8Gb Fibre Channel adapters with SFP+ LC-style connectors . The adapters connect to SFP+ Multimode Fiber SR optical modules. These adapters support 8 Gbps per port maximum bidirectional throughput for high-bandwidth storage (SAN). The PCI Express low profile form factor adapter can be used in either a standard PCI Express slot or a low profile PCI Express slot. Figure 1 shows the adapters.
Figure 1. QLogic 8Gb FC Host Bus Adapter
Figure 1. QLogic 8Gb FC Host Bus Adapter
Did you know?
QLogic 8Gb HBAs enable end-to-end SAN Solutions using 8 Gb Fibre Channel
technology for System x servers. They provide the ability to build high-
performance, highly available SANs and are easy to set up and integrate into
existing SAN configurations.
These adapters take advantage of QLogic’s StarPower technology, which provides
energy-smart features.
StarPower technology offers dynamic and adaptive power-management features
such as power-optimized and bandwidth-optimized intelligent PCI-Express link
training, low-power switching power supplies, and a thermally efficient layout
that requires lower airflow.
Part number information
Withdrawn: The adapters listed in this product guide are now withdrawn from marketing.
Table 1. Ordering part numbers and feature codes
Description | Part number | Feature code |
---|---|---|
QLogic 8Gb FC Single-port HBA | 42D0501 | 3578 |
QLogic 8Gb FC Dual-port HBA | 42D0510 | 3579 |
The part numbers for the QLogic 8Gb FC HBAs include the following items:
- One QLogic adapter with one or two 8 Gb transceivers installed
- Documentation package
- 2U bracket
Features
The QLogic 8Gb FC host bus adapters have the following features:
- Based on the QLogic QLE2560 (single port) and QLE2562 (dual port) adapters
- Function at 8/4/2 Gbps (auto-negotiation)
- Persistent binding
- LUN masking
- 2,048 concurrent logins
- PCI Express 2.0 x8 compliance, backwards compatibility with PCI-e 1.0a
- Two (for Dual-port) or one (for Single-port) SFP+ with LC-style connectors
- Standard PCI Express card with low profile MD2 form factor
- Support for both standard and low-profile PCI-E slots
Specifications
The QLogic 8Gb FC host bus adapters have the following specifications:
- Data rate: 1600 MBps full duplex per port
- Performance: up to 200,000 IOPS per port
- Boot support: BIOS, FCode, UEFI, EFI
- Protocols: FCP-3-SCSI; FC-Tape (FCP-2)
- Standard supported: Enhanced Authentication (FC-SP), Data Integrity (T10) and Network isolation (NPIV)
Server support
The QLogic 8Gb FC host bus adapters are supported in the servers listed in the
following tables.
Support for System x and dense servers with Xeon E5/E7 v4 and E3 v5 processors
Table 1. Support for System x and dense servers with Xeon E5/E7 v4 and E3 v5 processors
Part number
|
Description
| x3250 M6 (3943)| x3250 M6 (3633)| x3550 M5 (8869)| x3650
M5 (8871)| x3850 X6/x3950 X6 (6241, E7 v4)| nx360 M5 (5465, E5-2600
v4)| sd350 (5493)
---|---|---|---|---|---|---|---|---
42D0501| QLogic 8Gb FC Single-port HBA| Y| Y| Y| Y| Y| Y| N
42D0510| QLogic 8Gb FC Dual-port HBA| Y| Y| Y| Y| Y| Y| N
Support for servers with Intel Xeon v3 processors
Table 2. Support for servers with Intel Xeon v3 processors
Part number
|
Description
| x3100 M5 (5457)| x3250 M5 (5458)| x3500 M5 (5464)| x3550
M5 (5463)| x3650 M5 (5462)| x3850 X6/x3950 X6 (6241, E7 v3)|
nx360 M5 (5465)
---|---|---|---|---|---|---|---|---
42D0501| QLogic 8Gb FC Single-port HBA| Y| Y| Y| Y| Y| Y| Y
42D0510| QLogic 8Gb FC Dual-port HBA| Y| Y| Y| Y| Y| Y| Y
Support for servers with Intel Xeon v2 processors
Table 3. Support for servers with Intel Xeon v2 processors
Part number
|
Description
| x3500 M4 (7383, E5-2600 v2)| x3530 M4 (7160, E5-2400 v2)| x3550
M4 (7914, E5-2600 v2)| x3630 M4 (7158, E5-2400 v2)| x3650 M4 (7915,
E5-2600 v2)| x3650 M4 BD (5466)| x3650 M4 HD (5460)| x3750 M4
(8752)| x3750 M4 (8753)| x3850 X6/x3950 X6 (3837)| x3850
X6/x3950 X6 (6241, E7 v2)| dx360 M4 (E5-2600 v2)| nx360 M4 (5455)
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---
42D0501| QLogic 8Gb FC Single-port HBA| Y| Y| Y| Y| Y| N| Y| Y| Y| Y| Y| Y| Y
42D0510| QLogic 8Gb FC Dual-port HBA| Y| Y| Y| Y| Y| N| Y| Y| Y| Y| Y| Y| Y
See ServerProven for the latest information on the servers that support this
adapter:
http://www.lenovo.com/us/en/serverproven/xseries/sharedstorage/samatrix.shtml
Operating system support
The adapters support the following operating systems:
- QLogic 8Gb FC Single-port HBA, 42D0501
- QLogic 8Gb FC Dual-port HBA, 42D0510
Tip: This table is automatically generated based on data from Lenovo ServerProven. Note that older servers are not listed. Visit ServerProven to view OS support for those servers.
Table 2. Operating system support for QLogic 8Gb FC Single-port HBA, 42D0501
Operating systems| x3850/3950 X6 (3837)| x3850/3950 X6 (6241, E7
v2)| x3850/3950 X6 (6241, E7 v3)| x3850/3950 X6 (6241, E7 v4)|
x3250 M6 (3633)| nx360 M5 (5465)| x3500 M5 (5464)| x3550 M5
(5463)| x3550 M5 (8869)| x3650 M5 (5462)| x3650 M5 (8871)|
x3100 M5 (5457)| x3250 M5 (5458)
---|---|---|---|---|---|---|---|---|---|---|---|---|---
Microsoft Windows Server 2008 R2| Y| Y| Y| N| N| N| Y| Y| Y| Y| Y| Y| Y
Microsoft Windows Server 2012| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y
Microsoft Windows Server 2012 R2| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y
Microsoft Windows Server 2016| N| Y 1| Y 1| Y 1| Y| Y| Y| Y| Y| Y| Y| Y| Y
Microsoft Windows Server 2019| N| N| N| Y| Y| N| N| N| Y| N| Y| N| N
Microsoft Windows Server version 1709| N| N| Y| Y| Y| Y| Y| Y| Y| Y| Y| N| N
Microsoft Windows Server version 1803| N| N| N| N| N| N| N| N| Y| N| Y| N| N
Red Hat Enterprise Linux 5 Server Edition| N| N| N| N| N| N| N| N| N| N| N| Y|
Y
Red Hat Enterprise Linux 5 Server x64 Edition| N| N| N| N| N| N| N| N| N| N|
N| Y| Y
Red Hat Enterprise Linux 6 Server Edition| N| N| N| N| N| N| N| N| N| N| N| Y|
Y
Red Hat Enterprise Linux 6 Server x64 Edition| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y|
Y| Y| Y
Red Hat Enterprise Linux 7| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y
Red Hat Enterprise Linux 8.0| N| N| N| Y| N| N| N| N| N| N| N| N| N
SUSE Linux Enterprise Server 11 for AMD64/EM64T| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y|
Y| Y| Y
SUSE Linux Enterprise Server 11 for x86| N| N| N| N| N| N| N| N| N| N| N| Y| Y
SUSE Linux Enterprise Server 11 with Xen for AMD64/EM64T| Y| Y| Y| Y| N| Y| Y|
Y| Y| Y| Y| N| Y
SUSE Linux Enterprise Server 12| N| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y
SUSE Linux Enterprise Server 12 with Xen| N| Y| Y| Y| N| Y| Y| Y| Y| Y| Y| Y|
Y
SUSE Linux Enterprise Server 15| N| N| Y| Y| Y| Y| N| N| Y| N| Y| N| N
SUSE Linux Enterprise Server 15 with Xen| N| N| Y| Y| Y| Y| N| N| Y| N| Y| N|
N
VMware vSphere 5.1 (ESXi)| Y| Y| N| N| N| Y| Y| Y| N| Y| N| Y| Y
VMware vSphere Hypervisor (ESXi) 5.5| Y| Y| Y| N| Y| N| Y| Y| Y| Y| Y| Y| Y
VMware vSphere Hypervisor (ESXi) 6.0| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| N| Y
VMware vSphere Hypervisor (ESXi) 6.5| Y| N| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y
VMware vSphere Hypervisor (ESXi) 6.7| N| N| N| Y| Y 2| Y| Y 2| N| Y 2| N| Y 2|
N| N
- [in box driver support only]
- Detail information please refer to Support Tip HT506708
Table 3. Operating system support for QLogic 8Gb FC Dual-port HBA, 42D0510
Operating systems| x3850/3950 X6 (3837)| x3850/3950 X6 (6241, E7
v2)| x3850/3950 X6 (6241, E7 v3)| x3850/3950 X6 (6241, E7 v4)|
x3250 M6 (3633)| nx360 M5 (5465)| x3500 M5 (5464)| x3550 M5
(5463)| x3550 M5 (8869)| x3650 M5 (5462)| x3650 M5 (8871)|
x3100 M5 (5457)| x3250 M5 (5458)
---|---|---|---|---|---|---|---|---|---|---|---|---|---
Microsoft Windows Server 2008 R2| Y| Y| Y| N| N| N| Y| Y| Y| Y| Y| Y| Y
Microsoft Windows Server 2012| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y
Microsoft Windows Server 2012 R2| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y
Microsoft Windows Server 2016| N| Y 1| Y 1| Y 1| Y| Y| Y| Y| Y| Y| Y| Y| Y
Microsoft Windows Server 2019| N| N| N| Y| Y| N| N| N| Y| N| Y| N| N
Microsoft Windows Server version 1709| N| N| Y| Y| Y| Y| Y| Y| Y| Y| Y| N| N
Microsoft Windows Server version 1803| N| N| N| N| N| N| N| N| Y| N| Y| N| N
Red Hat Enterprise Linux 5 Server Edition| N| N| N| N| N| N| N| N| N| N| N| Y|
Y
Red Hat Enterprise Linux 5 Server x64 Edition| N| N| N| N| N| N| N| N| N| N|
N| Y| Y
Red Hat Enterprise Linux 6 Server Edition| N| N| N| N| N| N| N| N| N| N| N| Y|
Y
Red Hat Enterprise Linux 6 Server x64 Edition| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y|
Y| Y| Y
Red Hat Enterprise Linux 7| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y
Red Hat Enterprise Linux 8.0| N| N| N| Y| N| N| N| N| N| N| N| N| N
SUSE Linux Enterprise Server 11 for AMD64/EM64T| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y|
Y| Y| Y
SUSE Linux Enterprise Server 11 for x86| N| N| N| N| N| N| N| N| N| N| N| Y| Y
SUSE Linux Enterprise Server 11 with Xen for AMD64/EM64T| Y| Y| Y| Y| N| Y| Y|
Y| Y| Y| Y| N| Y
SUSE Linux Enterprise Server 12| N| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y
SUSE Linux Enterprise Server 12 with Xen| N| Y| Y| Y| N| Y| Y| Y| Y| Y| Y| Y|
Y
SUSE Linux Enterprise Server 15| N| N| Y| Y| Y| Y| N| N| Y| N| Y| N| N
SUSE Linux Enterprise Server 15 with Xen| N| N| Y| Y| Y| Y| N| N| Y| N| Y| N|
N
VMware vSphere 5.1 (ESXi)| Y| Y| N| N| N| Y| Y| Y| N| Y| N| Y| Y
VMware vSphere Hypervisor (ESXi) 5.5| Y| Y| Y| N| Y| N| Y| Y| Y| Y| Y| Y| Y
VMware vSphere Hypervisor (ESXi) 6.0| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| N| Y
VMware vSphere Hypervisor (ESXi) 6.5| Y| N| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y
VMware vSphere Hypervisor (ESXi) 6.7| N| N| N| Y| Y 2| Y| Y 2| N| Y 2| N| Y 2|
N| N
- [in box driver support only]
- Detail information please refer to Support Tip HT506708
Physical specifications
The QLogic 8Gb FC HBAs have the following physical specifications:
- Height: 64 mm (2.5 in)
- Width: 167 mm (6.6 in)
- Depth: 25 mm (1.0 in)
- Weight: 113 g (0.25 lb)
Operating environment
The adapters are supported in the following environment:
- Temperature:
- Operating: 0° to 55°C (32° to 131°F) at 0 to 914 m (0 to 3,000 ft)
- Storage: -40° to 70°C (-40° to 158°F) at 914 to 2,133 m (3,000 to 7,000 ft)
Relative humidity:
- Operating: 10% to 90% (relative, non-condensing)
- Non-operating: 5% to 93% (relative, non-condensing)
Warranty
One-year limited warranty. When installed in a System x server, these cards assume ther server’s base warranty and any warranty upgrade.
Related publications
For more information refer to the following documents:
-
Lenovo System x Fibre Channel options product page
https://www.lenovo.com/us/en/data-center/servers/server- options/system-x-options/networkingadapters/fibre-channel-host-bus-adapters/c /fibre-channel-hba -
QLogic 8Gb FC Single-port and Dual-port HBAs Installation and User’s Guide
http://ibm.com/support/entry/portal/docdisplay?lndocid=MIGR-5076985 -
ServerProven compatibility for System x HBAs:
http://www.lenovo.com/us/en/serverproven/xseries/sharedstorage/samatrix.shtml -
System x Configuration and Options Guide
http://www.lenovo.com/us/en/serverproven/xseries/sharedstorage/samatrix.shtml -
QLogic page for Lenovo products
http://qlogic.com/go/lenovo -
US Announcement Letter for the QLogic 8Gb FC Single-port and Dual-port HBAs
http://ibm.com/common/ssi/cgi- bin/ssialias?infotype=dd&subtype=ca&&htmlfid=897/ENUS108-481
Related product families
Product families related to this document are the following:
- Host Bus Adapters
Notices
Lenovo may not offer the products, services, or features discussed in this
document in all countries. Consult your local Lenovo representative for
information on the products and services currently available in your area. Any
reference to a Lenovo product, program, or service is not intended to state or
imply that only that Lenovo product, program, or service may be used. Any
functionally equivalent product, program, or service that does not infringe
any Lenovo intellectual property right may be used instead. However, it is the
user’s responsibility to evaluate and verify the operation of any other
product, program, or service. Lenovo may have patents or pending patent
applications covering subject matter described in this document. The
furnishing of this document does not give you any license to these patents.
You can send license inquiries, in writing, to:
Lenovo (United States), Inc.
8001 Development Drive
Morrisville, NC 27560
U.S.A.
Attention: Lenovo Director of Licensing
LENOVO PROVIDES THIS PUBLICATION ”AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER
EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some
jurisdictions do not allow disclaimer of express or implied warranties in
certain transactions, therefore, this statement may not apply to you.
This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. Lenovo may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice.
The products described in this document are not intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. The information contained in this document does not affect or change Lenovo product specifications or warranties. Nothing in this document shall operate as an express or implied license or indemnity under the intellectual property rights of Lenovo or third parties. All information contained in this document was obtained in specific environments and is presented as an illustration. The result obtained in other operating environments may vary. Lenovo may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you.
Any references in this publication to non-Lenovo Web sites are provided for
convenience only and do not in any manner serve as an endorsement of those Web
sites. The materials at those Web sites are not part of the materials for this
Lenovo product, and use of those Web sites is at your own risk. Any
performance data contained herein was determined in a controlled environment.
Therefore, the result obtained in other operating environments may vary
significantly. Some measurements may have been made on development-level
systems and there is no guarantee that these measurements will be the same on
generally available systems. Furthermore, some measurements may have been
estimated through extrapolation. Actual results may vary. Users of this
document should verify the applicable data for their specific environment.
© Copyright Lenovo 2022. All rights reserved.
This document, TIPS0721, was created or updated on January 2, 2020.
Send us your comments in one of the following ways:
-
Use the online Contact us review form found at:
https://lenovopress.lenovo.com/TIPS0721 -
Send your comments in an e-mail to:
comments@lenovopress.com
This document is available online at https://lenovopress.lenovo.com/TIPS0721
Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo
in the United States, other countries, or both. A current list of Lenovo
trademarks is available on the Web at
https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other countries, or both:
- Lenovo®
- ServerProven®
- System x®
The following terms are trademarks of other companies:
Intel® and Xeon® are trademarks of Intel Corporation or its subsidiaries.
Linux® is the trademark of Linus Torvalds in the U.S. and other countries.
Microsoft®, Windows Server®, and Windows® are trademarks of Microsoft
Corporation in the United States, other countries, or both.
Other company, product, or service names may be trademarks or service marks of
others.
References
- IBM Support
- Welcome | ServerProven
- WWPN not visible under NPIV config in VMWare ESXi 6.5 and 6.7 Host Web UI (Not the vCenterWeb UI) - Lenovo Server - Lenovo Support US
- Host Bus Adapters > Lenovo Press
- QLogic 8Gb FC Host Bus Adapters for System x Product Guide (withdrawn product) > Lenovo Press
- Configuration and Options Guide (COG) - Lenovo x86 Servers - Lenovo Support US
- Lenovo server options, accessories and upgrades | Lenovo US
- Copyright and Trademark Information | Lenovo US | Lenovo US
- Welcome | ServerProven
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>