Lenovo 00AE995 Enterprise io3 PCIe Flash Adapters Owner’s Manual
- June 3, 2024
- Lenovo
Table of Contents
Enterprise io3 PCIe Flash Adapters
Product Guide (withdrawn product)
Owner’s Manual
00AE995 Enterprise io3 PCIe Flash Adapters
Engineered for application acceleration, the Enterprise io3 PCIe Flash
Adapters can help deliver higher performance than typical solid-state devices
at a fraction of the cost and space, which makes them a perfect fit for a
broad range of applications, including database and cloud applications, big
data analytics, and hyper-scale data center workloads.
Delivering high speed, low latency, and high efficiency, this new third-
generation line of flash adapters brings scalable and optimized performance to
distributed scale-out architectures at low cost. These adapters are designed
primarily for servers and computing appliances to maximize compute efficiency
while providing the added benefits of lower power and cooling costs, low
management impact, and smaller storage footprints.
The Enterprise io3 PCIe Flash Adapters are shown in the following figure.
Did you know?
The Enterprise io3 PCIe Flash Adapters use flash memory as their storage
medium. The adapters contain no moving parts and do not have issues associated
with vibration, noise, and mechanical failure. The adapters are built as block
devices on a PCIe bus with advanced wear-leveling, ECC protection, and chip-
level fault tolerance, which provides exceptional reliability and efficiency.
The Enterprise io3 PCIe Flash Adapters can provide lower operational
expenditure (OPEX) and capital expenditure (CAPEX) in applications that
require high storage I/O performance compared to solutions that use many hard
disk drives and solid-state drives to achieve equivalent performance.
Rigorous testing of the Enterprise io3 PCIe Flash Adapters by Lenovo through
the ServerProven® program ensures a high degree of confidence in storage
subsystem compatibility and reliability. Providing another peace of mind, the
adapters are covered under a Lenovo warranty.
Click here to check for updates
Part number information
The following table lists the ordering part numbers and feature codes for the
adapters.
Withdrawn: All adapters are now withdrawn from marketing.
Table 1. Ordering part numbers and feature codes
Description | Part number | Feature code |
---|---|---|
1000GB Enterprise io3 Flash Adapter | 00AE995 | ARYP |
1300GB Enterprise io3 Flash Adapter | 00AE998 | ARYQ |
2600GB Enterprise io3 Flash Adapter | 00JY001 | ARYR |
5200GB Enterprise io3 Flash Adapter | 00JY004 | ARYS |
The part numbers for the adapters include the following items:
- A PCIe Flash Adapter with a full-height (3U) bracket attached
- Low-profile (2U) bracket (1000GB, 1300GB, and 2600GB adapters only)
- USB Key with documentation
- Quick Install Guide
- Important Notices document
- Warranty Flyer
Features
Based on the Fusion ioMemory PX600 adapter with silicon-based NAND clustering
storage technology, the Enterprise io3 PCIe Flash Adapters offer cost-
effective Multi-Level Cell (MLC) technology in standard PCIe form factors.
These adapters use NAND flash memory as the basic building block of solid-
state storage and contain no moving parts, so they are less sensitive to
issues that are associated with vibration, noise, and mechanical failure.
These adapters are built as block devices on a PCIe bus with advanced wear-
leveling, ECC, and chip-level fault tolerance, which provides exceptional
reliability and efficiency.
The Enterprise io3 PCIe Flash Adapters can deliver fast and scalable
performance for mixed read- and write-intensive workloads at low latency
required for webscale and cloud environments. The following typical
applications require ultra-high I/O performance:
- Large-scale transaction processing
- Cloud computing
- Content distribution
- On-demand streaming
- Data warehousing
- Business intelligence and analytics
- Decision support
The Enterprise io3 PCIe Flash Adapters have the following features:
-
Technology:
ο Up to 5.2 TB of solid-state storage in an industry-standard PCIe form factor.
ο High-density design with cost-effective MLC NAND technology reduces storage footprint.
ο Functions as a PCIe storage and controller device. The operating system sees a block device. -
Performance:
ο High-speed, low latency, consistent, and scalable I/O performance
ο Access latency can be as low as 15 µs
ο Up to 2.7 GBps/2.2 GBps of sustained sequential read/write throughput
ο Up to 330,000/375,000 random read/write IOPS that uses 4 KB data blocks
ο Integrates with host processor as a memory tier for direct parallel access to flash -
Reliability:
ο Advanced wear leveling
ο ECC protection
ο Adaptive Flashback redundancy for RAID-like chip protection with self- healing capabilities
ο Monitoring and management:
ο Power consumption
ο Thermal information
ο Flash wear-out
Note: These adapters cannot be used as bootable devices.
Technical specifications
The following table lists the technical specifications for the Enterprise io3
PCIe Flash adapters.
Table 2. Enterprise io3 PCIe Flash Adapter technical specifications
Specification | 1000 GB | 1300 GB | 2600 GB | 5200 GB |
---|---|---|---|---|
Part number | 00AE995 | 00AE998 | 00JY001 | 00JY004 |
Interface | PCIe 2.0 x8 | PCIe 2.0 x8 | PCIe 2.0 x8 | PCIe 2.0 x8 |
Form factor | Half-height, half-length | Half-height, half-length | Full-height, | |
half-length | Full-height, half-length | |||
Capacity | 1000 GB | 1300 GB | 2600 GB | 5200 GB |
Endurance | 12 PB TBW | 16 PB TBW | 32 PB TBW | 64 PB TBW |
Random read IOPS (4 KB blocks) | 196,000 | 235,000 | 330,000 | 276,000 |
Random write IOPS (4 KB blocks) | 320,000 | 370,000 | 375,000 | 375,000 |
Sequential read throughput | 2.7 GBps | 2.7 GBps | 2.7 GBps | 2.7 GBps |
Sequential write throughput | 1.5 GBps | 1.7* GBps | 2.2 GBps* | 2.1 GBps* |
Read access latency | 92 µs | 92 µs | 92 µs | 92 µs |
Write access latency | 15 µs | 15 µs | 15 µs | 15 µs |
Power requirements | 25 W | 25 W | 25 W | 25 W |
- Write throughput is achieved with the optional high-power mode. Maximum write throughput of 1.6 GBps can be achieved within a 25 W power limit.
Enterprise and Enterprise Value solid-state devices have comparable read and write IOPS and throughput performance, but the key difference between them is their endurance (or lifetime); that is, how long they can perform write operations because solid-state devices have a finite number of program/erase (P/E) cycles. Enterprise PCIe Flash Adapters have better endurance and higher IOPS/GB ratio but also a higher cost/IOPS ratio compared to Enterprise Value PCIe Flash adapters. Because of this fact, the Enterprise PCIe Flash Adapters are targeted for mixed read- and write-intensive workloads and the Enterprise Value PCIe Flash Adapters are targeted for read-intensive workloads. Solid- state device writes endurance often is measured by the number of P/E cycles that the drive incurs over its lifetime, which is listed as the total bytes of written (TBW) data in the device specification.
The TBW value that is assigned to a solid-state device is the total bytes of written data (based on the number of P/E cycles) that a device can be guaranteed to complete (the percentage of remaining P/E cycles is equal to the percentage of remaining TBW). The Lenovo warranty for solid-state storage is limited to devices that have not reached the maximum guaranteed number of program/erase cycles. Solidstate storage that reaches this limit might fail to operate according to its specifications. Because of such behavior by solid- state devices, careful planning must be done to use solid-state storage in the application environments to ensure that the TBW of the device is not exceeded before the end of the required life expectancy.
Writes are tracked and reported by the adapter’s management utility and might be affected by application writes, data patterns, and maintenance designed to maximize data integrity.
Server support
The following tables list the server compatibility information for the
Enterprise io3 PCIe Flash Adapters.
Support for System x and dense servers with Xeon E5/E7 v4 and E3 v5
processors
Table 3. Support for System x and dense servers with Xeon E5/E7 v4 and E3 v5
processors
This adapter cannot be factory
installed; it is supported as a field-installable option only. The server
cannot be shipped with this adapter installed.
Support for System x and dense servers with Intel Xeon v3 processors
Table 4. Support for System x servers with Intel Xeon v3 processors
This adapter cannot be factory
installed; it is supported as a field-installable option only. The server
cannot be shipped with this adapter installed.
Support for System x and dense servers with Intel Xeon v2 processors
Table 5. Support for System x servers with Intel Xeon v2 processors
* This adapter cannot be factory
installed; it is supported as a field-installable option only. The server
cannot be shipped with this adapter installed.
Support for Flex System compute nodes
Table 6. Support for Flex System servers
† Supported with installation in an
attached PCIe Expansion Node
See the following ServerProven website for the latest compatibility
information for System x servers:
http://www.lenovo.com/us/en/serverproven/
For further information about server compatibility, see this support page:
https://support.lenovo.com/us/en/documents/serv-io3
Supported operating systems
The Enterprise io3 PCIe Flash Adapters support the following operating
systems:
- Microsoft Windows Server 2008 R2
- Microsoft Windows Server 2012
- Microsoft Windows Server 2012 R2
- Red Hat Enterprise Linux 5 Server with Xen x64 Edition
- Red Hat Enterprise Linux 5 Server x64 Edition
- Red Hat Enterprise Linux 6 Server x64 Edition
- Red Hat Enterprise Linux 7
- SUSE LINUX Enterprise Server 11 for AMD64/EM64T
- SUSE LINUX Enterprise Server 11 with Xen for AMD64/EM64T
- SUSE Linux Enterprise Server 12
- SUSE Linux Enterprise Server 12 with XEN
- VMware vSphere 5.1 (ESXi)
- VMware vSphere 5.5 (ESXi)
- VMware vSphere 6.0 (ESXi)
For more information about the specific supported versions and service packs,
see the following ServerProven web page:
http://www.lenovo.com/us/en/serverproven/xseries/storage/mcmatrix.shtml
On the ServerProven page, click the check mark that is associated with the
server in question to see more information about the operating system support.
Warranty
The Enterprise io3 PCIe Flash Adapters carry a 1-year, customer-replaceable
unit (CRU) limited warranty.
When installed in a supported Lenovo server, these adapters assume the
system’s base warranty and any warranty upgrade.
Physical specifications
The 1000GB, 1300GB, and 2600GB Enterprise io3 PCIe Flash Adapters have the
following physical specifications:
Dimensions and weight (approximate):
- Height: 17 mm (0.7 in.)
- Width: 69 mm (2.7 in.)
- Depth: 167 mm (6.6 in.)
- Weight: 152 g (0.3 lb)
Shipping dimensions and weight (approximate):
- Height: 65 mm (2.6 in.)
- Width: 245 mm (9.6 in.)
- Depth: 225 mm (8.9 in.)
- Weight: 421 g (0.9 lb)c
The 5200GB Enterprise io3 PCIe Flash Adapter has the following physical
specifications:
Dimensions and weight (approximate):
- Height: 17 mm (0.7 in.)
- Width: 112 mm (4.4 in.)
- Depth: 167 mm (6.6 in.)
- Weight: 212 g (0.5 lb)
Shipping dimensions and weight (approximate):
- Height: 65 mm (2.6 in.)
- Width: 245 mm (9.6 in.)
- Depth: 225 mm (8.9 in.)
- Weight: 481 g (1.1 lb)
Operating environment
The Enterprise io3 PCIe Flash Adapters are supported in the following environment:
- Temperature (operational): 0 – 55 °C (32 – 131 °F) at 0 – 3,048 m (0 – 10,000 ft)
- Relative humidity: 5 – 95% (non-condensing)
- Maximum altitude (operational): 3,048 m (10,000 ft)
Agency approvals
The Enterprise io3 PCIe Flash Adapters conform to the following regulations:
- FCC Title 47, Part 15 Subpart B, Class A
- CAN ICES-3 (A) NMB-3 (A)
- EN 55022: 2010
- EN 61000-3-2: 2006 plus A1:2009 and A2:2009
- EN 61000-3-3: 2008
- EN 55024: 2010
- VCCI V-3/2013.04 Class A & EN 55022: 2010 Class A
- ANSI C63.4: 2009
- BSMI CNS 13438: 2006 Class A
- EN 55022 (2006)A1 (2007) Class A
- AS/NZS CISPR 22: 2009 plus A1:2010
- MSIP-REM-FIO-ioScale3
- EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011 and IEC 60950-1:2005 A1:2009
- DIRECTIVE 2011/65/EU
- MIL-STD-810
Related publications and links
For more information, see the following documents:
-
Flash Adapters product page
http://shop.lenovo.com/us/en/systems/servers/options/systemx/storage/solid- state/flash-adapters/ -
US Announcement Letter
http://ibm.com/common/ssi/cgi- bin/ssialias?infotype=dd&subtype=ca&&htmlfid=897/ENUS114-138 -
io3 Flash Adapter configuration information and requirements
https://support.lenovo.com/us/en/documents/serv-io3 -
ioMemory VSL 4.1.2 io3 Flash Adapter Hardware Installation Guide (PDF)
https://support.lenovo.com/us/en/docs/UM104182 -
ioMemory VSL 4.1.2 Release Notes (PDF)
https://support.lenovo.com/us/en/docs/UM104183 -
ioMemory VSL 4.1.2 User Guide for Linux (PDF)
https://support.lenovo.com/us/en/docs/UM104184 -
ioMemory VSL 4.1.2 User Guide for Microsoft Windows (PDF)
https://support.lenovo.com/us/en/docs/UM104185 -
ioMemory VSL 4.1.2 User Guide for VMware ESXi (PDF)
https://support.lenovo.com/us/en/docs/UM104186 -
Flash Management Console 3.15.0 Installation Guide (PDF)
https://support.lenovo.com/us/en/docs/UM104178 -
Flash Management Console 3.15.0 Release Notes (PDF)
https://support.lenovo.com/us/en/docs/UM104179 -
Flash Management Console 3.15.0 Tools Guide (PDF)
https://support.lenovo.com/us/en/docs/UM104180 -
Flash Management Console 3.15.0 User Guide (PDF)
https://support.lenovo.com/us/en/docs/UM104181 -
System x Configuration and Options Guide
https://support.lenovo.com/us/en/documents/SCOD-3ZVQ5W -
ServerProven
http://www.lenovo.com/us/en/serverproven/
Related product families
Product families related to this document are the following:
Notices
Lenovo may not offer the products, services, or features discussed in this
document in all countries. Consult your local Lenovo representative for
information on the products and services currently available in your area. Any
reference to a Lenovo product, program, or service is not intended to state or
imply that only the Lenovo product, program, or service may be used. Any
functionally equivalent product, program, or service that does not infringe
any Lenovo intellectual property right may be used instead. However, it is the
user’s responsibility to evaluate and verify the operation of any other
product, program, or service. Lenovo may have patents or pending patent
applications covering the subject matter described in this document. The
furnishing of this document does not give you any license to these patents.
You can send license inquiries, in writing, to:
Lenovo (United States), Inc.
8001 Development Drive
Morrisville, NC 27560
The U.S.A.
Attention: Lenovo Director of Licensing
LENOVO PROVIDES THIS PUBLICATION ”AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER
EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR A PARTICULAR PURPOSE. Some
jurisdictions do not allow disclaimers of express or implied warranties in
certain transactions, therefore, this statement may not apply to you.
This information could include technical inaccuracies or typographical errors.
Changes are periodically made to the information herein; these changes will be
incorporated in new editions of the publication. Lenovo may make improvements
and/or changes in the product(s) and/or the program(s) described in this
publication at any time without notice.
The products described in this document are not intended for use in
implantation or other life support applications where malfunction may result
in injury or death to persons. The information contained in this document does
not affect or change Lenovo product specifications or warranties. Nothing in
this document shall operate as an express or implied license or indemnity
under the intellectual property rights of Lenovo or third parties. All
information contained in this document was obtained in specific environments
and is presented as an illustration. The result obtained in other operating
environments may vary. Lenovo may use or distribute any of the information you
supply in any way it believes appropriate without incurring any obligation to
you.
Any references in this publication to non-Lenovo Web sites are provided for
convenience only and do not in any manner serve as an endorsement of those Web
sites. The materials at those Web sites are not part of the materials for this
Lenovo product, and use of those Web sites is at your own risk. Any
performance data contained herein was determined in a controlled environment.
Therefore, the result obtained in other operating environments may vary
significantly. Some measurements may have been made on development-level
systems and there is no guarantee that these measurements will be the same on
generally available systems. Furthermore, some measurements may have been
estimated through extrapolation. Actual results may vary. Users of this
document should verify the applicable data for their specific environment.
© Copyright Lenovo 2022. All rights reserved.
This document, TIPS1236, was created or updated on June 7, 2016.
Send us your comments in one of the following ways:
-
Use the online Contact us review form found at:
https://lenovopress.lenovo.com/TIPS1236 -
Send your comments in an e-mail to:
comments@lenovopress.com
This document is available online at
https://lenovopress.lenovo.com/TIPS1236.
Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo
in the United States, other countries, or both. A current list of Lenovo
trademarks is available on the Web at
https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other
countries, or both:
Lenovo®
Flex System
ServerProven®
System x®
The following terms are trademarks of other companies:
Intel® and Xeon® are trademarks of Intel Corporation or its subsidiaries.
Linux® is the trademark of Linus Torvalds in the U.S. and other countries.
Microsoft®, Windows Server®, and Windows® are trademarks of Microsoft
Corporation in the United States, other countries, or both.
Other company, product, or service names may be trademarks or service marks of
others.
References
- Lenovo Official US Site | Laptops, PCs, Tablets & Data Center | Lenovo US
- Welcome | ServerProven
- Welcome | ServerProven
- PCIe Flash Adapters > Lenovo Press
- Enterprise io3 PCIe Flash Adapters Product Guide (withdrawn product) > Lenovo Press
- io3 Flash Adapter Flash Management Console 3.15.0 Installation Guide - Lenovo Support US
- io3 Flash Adapter Flash Management Console 3.15.0 Release Notes - Lenovo Support US
- io3 Flash Adapter Documentation - System x - [Flash Management Console 3.15.0 Tools Guide] - Lenovo Support US
- io3 Flash Adapter Flash Management Console 3.15.0 User Guide - Lenovo Support US
- ioMemory VSL 4.1.2 io3 Flash Adapter Hardware Installation Guide - Lenovo Support US
- io3 Flash Adapter Documentation - ioMemory VSL 4.1.2 Release Notes - Lenovo Support US
- io3 Flash Adapter ioMemory VSL 4.1.2 User Guide for Linux - Lenovo Support US
- io3 Flash Adapter Documentation oMemory VSL 4.1.2 User Guide for Microsoft Windows - Lenovo Support US
- io3 Flash Adapter ioMemory VSL 4.1.2 User Guide for VMware ESXi - Lenovo Support US
- Configuration and Options Guide (COG) - Lenovo x86 Servers - Lenovo Support US
- io3 Flash Adapter configuration information and requirements - Lenovo Support US
- Copyright and Trademark Information | Lenovo US | Lenovo US
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>