Introduction

Palm NRG is a portable and battery-powered multi-function device, offering both Transcutaneous Electrical Nerve Stimulation (TENS). As a pain relief device, Palm NRG delivers electric impulses to tired and sore muscles. These impulses are generated by the device and delivered through the connecting wires and electrodes to the target body areas. The impulses mimic the action potential coming from the central nervous system to trigger the contraction of the muscle. Palm NRG has 12 operation modes, and its display screen can show battery power, selected mode, current intensity, and time remaining of an application mode. The device is equipped with accessories of four electrode pads, two electrode cables, one battery charger, one USB cable, and one wire roller coupled with the pad holder. Palm Nrg 12 stimulating gloves and socks Combo set is made
with soft and elastic polyester knit with mini conductive wires ensuring that pulses are evenly distributed across the hands and feet throughout the body to relieve pain and provide maximum and ultimate comfort. It May help treat pain associated with arthritis, sports injuries, swelling, and nerve damage TENS therapy works by blocking pain signals from nerves to the brain and helps release pain-relieving endorphins

Cleaning and maintenance

Please use water or neutral detergent to clean the device first, and then use the dry cloth to wipe it again. The electrode pads coming with the device are disposable and should be replaced when their adhesiveness becomes worse. Contact the vendor for replacements. Do not let the sticky side of the pad touch anything, including the greasy fingertips.

Positions for use

PALM-NRG-537A-9908-Tens-EMS-Pain-Relief-and-Recovery-System-
FIG-2

| lo ng or the intensity is

set too high

| or reduce the intensity
---|---|---
The       elect  rod e          pad

surface if worn out

| Rpe la ce e lect ro de pad
No

source; display LCD.

| power no on| The battery capacity is

depleted

| Charge the battery
Powe r cuts off

during use

| The battery is weak| Charge the battery
The cord is broken| Replace the cord

It is    difficult  to attach the  pad to the skin

| Have you removed the transparent film from the pad?| Peel off the film on the adhesive  surface of the pads
Wasthepad applied

immediately after washing?

| Dry the pad
Is the adhesive surface of the pad damaged?| Replace the pad

Ad hesive

surface of pad

is not st ic ky

| Pads get deteriorative| Contact the replacements.| vendor| for
Were the pads red under high temperature, high humidity, or direct

sunshine?

| Rep lace the pad.

Safety warnings

DANGER

  1. Do not use this unit if you are using an implanted electronic medical device such as a pacemaker or other life-maintaining device.
  2. Do not use this unit if you are wearing electronic medical devices for monitoring health functions.

WARNING
Users should immediately stop using the device and should consult with physicians feeling any discomfort.

  1. The long-term effects of chronic electrical stimulation are unknown.
  2. Do not use stimulation over the main arteries around your neck.
  3. Do not use stimulation over the neck or mouth. Severe spasms of muscles may occur and the contractions may be strong enough to close the airway or cause difficulty in breathing.
  4. Do not apply stimulation directly to the heart area across the chest or on the chest.
  5. Do not use stimulation on your head or across your head.
  6. Do not use stimulation over swollen, infected, or inflamed areas or skin eruptions, e.g., phlebitis, thrombophlebitis, or varicose veins.
  7. Do not use stimulation over, or in proximity to, cancerous lesions.
  8. Do not use stimulation when charging the device.

NOTICE

  1. Do not use the muscle stimulator during pregnancy.

  2. Do not use it if you have heart problems.

  3. Do not use it if you have epilepsy.

  4. Do not use the device in the presence of the following:
    a. When there is a tendency to hemorrhage following acute trauma or fracture;
    b. Following recent surgical procedures when muscle contraction may disrupt the healing process;
    c. Over the menstruating or pregnant uterus;
    d. Over areas of the skin which lack normal sensation.

  5. Do not use the products near the heart, it may cause a fast or irregular heartbeat.

  6. Some patients may experience skin irritation or hypersensitivity due to the electrical stimulation or electrical conductive medium.

  7. Palm NRG must be kept out of the reach of children.

  8. Palm NRG should be used only with the leads and electrodes recommended.

  9. Never apply the pads to your skin with the power on, which will result in sudden shock And when the power is on, do not remove or move the pads.

  10. Two pads should be used together as a pair. Always peel off the protective film on the pads before use. To avoid an electrical short, do not connect two pads to each other.

  11. Do not apply pads to the same spot for over 60 minutes at a time.

  12. Do not use the Palm NRG while driving, operating machinery, or during any activity in which involuntary muscle contractions may put the user at undue risk of injury.

Troubleshooting

PALM-NRG-537A-9908-Tens-EMS-Pain-Relief-and-Recovery-
System-FIG-1

  1. To change the modes, press the M (Mode) button. The unit is with A & B independent channels, both A&B modes, and A&B intensity. Press “A/B” button to adjust the modes and intensity for each channel. Once you have selected a mode, gradually increase the intensity by pressing the + button and decrease the intensity by pressing the button. When the intensity “A” mark on the display flashes, the intensity “A” is adjusted by pressing the+/ – button, and you could press the “A/B” button to change to Intensity “B”. The chosen power output depends on your comfort level. As the precondition of acceptance, the intensity should be chosen as high as possible for the best effect but still feel comfortable.
    Notes: The unit is very safe, the output intensity increases only by pushing the”+ “key. Even if the intensity is increased to the maximum, it is within the safe range, but may feel uncomfortable. When changing modes, the intensity of the pulse will reset itself back to the minimum strength conducted from the ports of this device. It is necessary to regulate the intensity of your unit each time you change from one of the existing 12 modes to another.

  2. To set the time of use, press the “T “button. The auto time set is 20 minutes. Each press of the button adjusts the time by IO minutes. After the time runs out the device toms off automatically, and it can be restarted if trea1ment is needed to be continued.

  3. Sit back and enjoy the deep soothing sensations!

  4. Each of the 12 modes offers a unique pulse.

  5. If you need to turn off the device during stimulation, slide the On/Off switch to “OFF”.

  6. Before storing the device use the protective film to cover the electrode pads.

  7. Do not use the product in the bathroom or in a moist environment. Do not use it while bathing.

  8. Do not use the product in the condition of air mixed with flammable gas.

  9. Never use this product in concurrence with high-frequency surgical equipment; it may result in bums at the site of the stimulator electrodes and possible damage to the control unit.

  10. Never use this product near a microwave oven or other high-frequency equipment.

  11. Never use this product while it is being charged

  12. Do not operate the product in close proximity to shortwave therapy equipment

Socks & Gloves User Instructions

  1. Connect the electrode wire to the gloves\socks.
  2. Put on the gloves\socks.
  3. Connect the plug of the electrode wire into the palm unit.
  4. Adjust the intensity and enjoy the relief of arthritis and hand pain.

Safety symbols

  • Type B applied part
  • Attention, see the operating manual for use

Indications for Use
To be used for temporary relief of pain associated with sore and aching muscles in the shoulder, waist, back, neck, upper extremities (arm), and lower extremities (leg) due to strain from exercise or normal household work activities.

Specifications

  • Power supply: DC 3.7V
  • Output voltage: 42V@S00O
  • Output current: 84mA@S00O
  • Consumed current: 40mA
  • Pulse width: 220µs
  • Frequency: 1-l l0Hz
  • Timer: 10-60 minutes
  • Strength level adjustment: 20 levels
  • Charger: 100-220V,S0/60Hz,and 1 0mA (input);DCSV,300mA( output)

Operation

PALM-NRG-537A-9908-Tens-EMS-Pain-Relief-and-Recovery-System-
FIG-3

To operate

  1. The machine needs to be charged for up to 10 hours before the first use.

  2. Connect the electrode cables to the output sockets at the bottom of the unit.

  3. Connect the pads to the cables by snapping them on.

  4. Use a damp towel to wipe the skin where you intend to put the pads, so as to remove any body oil, cosmetics, or dirt. Remove the protective film and place the pads on the area making sure that both pads are on the skin and not overlapping.
    Warning: To avoid an electrical short, never put two electrode pads together.

  5. Tum on the unit by sliding the On/Off switch from Off to On.
    Warning: Do not move pads or touch them with your hands during use, it may cause strong stimulation.

  6. When you have turned on the unit, the LCD display will automatically show Mode 1. The “T” (Timer) will automatically choose the time duration of20 minutes.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)