SHURE AD2 Digital Handheld Wireless Microphone Transmitter User Guide

June 4, 2024
Shure

SHURE AD2 Digital Handheld Wireless Microphone Transmitter

SHURE AD2
Digital Handheld Wireless Microphone Transmitter feature

AD series hand-held transmitters deliver impeccable audio quality and RF performance with wide-tuning, High Density (HD) mode, and encryption. The transmitter features durable metal construction, AA or Shure rechargeable battery (with dockable charging), and black or nickel finish options.

Features

Performance

  • 20 Hz to 20 kHz range with a flat frequency response
  • Automatic input staging optimizes gain setting
  • AES 256-bit encryption-enabled for secure transmission
  • 120 dB dynamic range
  • 100 meter (300 feet) line-of-sight operating range
  • Selectable modulation modes optimize performance for spectral efficiency or audio quality:
    • Standard – optimal coverage, low latency
    • High density – a dramatic increase in max system channel count
  • Switchable Power Levels = 2/10/35 mW (region dependent) Built-in tone generator and RF markers to facilitate range-testing

Design

  • Interchangeable Shure microphone cartridges
  • Backlit LCD with easy-to-navigate menu and controls
  • Rugged metal construction
  • Menu and power lockout

Power

  • Up to 8 hours continuous use with 2 x AA alkaline batteries
  • Shure lithium-ion rechargeable battery provides extended battery life, precision metering, and zero memory effect
  • External charging contacts for docked charging

Included Components

Zipper Bag 95B2313
Threaded Adapter 31B1856
Swivel Adapter, black 90F4046
--- ---
AA alkaline batteries (2) 80B8201
Battery Contact Cover WA618

Choice of (1) of the following Shure microphone cartridges:

SM58 (RPW112) KSM9 Nickel (RPW188)
BETA 87C (RPW122) BETA 87A (RPW120)
BETA 58A (RPW 118) KSM9 Black (RPW184)
KSM8 Black (RPW174) KSM8 Nickel (RPW170)
KSM9HS Black (RPW186) KSM9HS Nickel (RPW190)

Optional Accessories

Shure Lithium-Ion Rechargeable Battery. SB900B
Radome Color ID Kit for AD2 WA617M
Wireless Microphone Clip WA371

Optional Shure microphone cartridges:

  • SM58 (RPW112)
  • SM86 (RPW114)
  • SM87A (RPW116)
  • BETA 58A (RPW118)
  • BETA 87A (RPW120)
  • BETA 87C (RPW122)
  • VP68 (RPW124)
  • KSM9 Nickel (RPW188)
  • KSM9HS Nickel (RPW190)
  • KSM9 Black (RPW184)
  • KSM9HS Black (RPW186)

AD2 Transmitter Overview

  1. Microphone Cartridge
    See Optional Accessories for a list of compatible cartridges.

  2. Display
    View menu screens and settings. Press any control button to activate the backlight.

  3. Infrared (IR) Port
    Align with the receiver IR port during an IR Sync for automated transmitter programming.

  4. Menu Navigation Buttons
    Use to navigate through parameter menus and change values.

  5. Battery Compartment
    Requires Shure rechargeable battery or 2 AA batteries.

  6. AA Battery Adapter
    Remove to accommodate a Shure rechargeable battery.

  7. On/Off Switch
    Powers the unit on or off.

  8. Battery Door
    Latch to secure batteries.

  9. Handle
    Unscrew to access controls and batteries.SHURE AD2 Digital Handheld Wireless
Microphone Transmitter fig 1

Transmitter Controls

Use to navigate through parameter menus and change values.

exit| Acts as a ‘back’ button to return to previous menus or parameters without confirming a value change
---|---
enter| Enters menu screens and confirms parameter changes
∨∧| Use to scroll through menu screens and to change parameter values

Tip: Use the following shortcuts for quick setup:

  • Hold the ∧ button while powering on to lock or unlock the transmitter controls.
  • Hold the exit button while powering on to enter the Safe Start menu.

Home Screen Display

The home screen shows transmitter information and status.
There are four pieces of information that you can choose to see on the home screen. Use the arrow buttons to select one of the following choices:SHURE
AD2 Digital Handheld Wireless Microphone Transmitter fig
22

The following icons indicate transmitter settings:SHURE AD2 Digital Handheld
Wireless Microphone Transmitter fig 4

Locking the Interface

Lock transmitter interface controls to prevent accidental or unauthorized changes to parameters. The lock icon appears on the home screen when a lock is enabled.

  1. From the utility menu, navigate to Locks and select one of the following lock options:
    • None: The controls are unlocked
    • Power: The power switch is locked
    • Menu: The menu parameters are locked
    • All: The power switch and menu parameters are locked
  2. Press enter to save.

Tip: To quickly unlock a transmitter: Press enter twice, select None, and press enter.

Batteries

Battery InstallationSHURE AD2 Digital Handheld Wireless Microphone
Transmitter fig 5

Accessing the battery compartment| ****

Unscrew the cover on the transmitter as shown to access the battery compartment.

---|---




Installing batteries

| ****

•     AA batteries: Place batteries (note polarity markings) and AA Adapter as shown. Close the door to secure the batteries.

•     Shure rechargeable battery: Place battery as shown (note polarity markings). Remove the AA adapter and stow it in the door. Close the door to secure the battery.


If using AA batteries, set the battery type using the transmitter menu.

Setting the AA Battery Type
To ensure accurate display of transmitter runtime, set the battery type in the transmitter menu to match the installed AA battery type.

If a Shure rechargeable battery is installed, selecting a battery type is not necessary and the battery type will display Shure.

  1. Navigate to the Utilities and select Battery.
  2. Use the ▼▲ buttons to select the installed battery type:
    • Alkaline = Alkaline
    • NiMH = Nickel Metal Hydride
    • Lithium = Lithium Primary
  3. Press enter to save.SHURE AD2 Digital Handheld Wireless Microphone Transmitter fig 7

Shure Rechargeable Battery

Shure SB900-series lithium-ion batteries offer a rechargeable option for powering the transmitters. Batteries quickly charge to 50% capacity in one hour and reach full charge within three hours.
Single chargers and multiple bay chargers are available to recharge the Shure batteries. The SB900B rechargeable battery us­es SBC200, SBC800 and SBC220 chargers.

Caution: Only charge Shure rechargeable batteries with a Shure battery charger.
Note: A Battery Hot warning indicates that the transmitter battery needs to cool off. Otherwise, the transmitter will shut down. Let the device cool down and then consider swapping the transmitter battery to continue operation.
Identify any possible external heat sources to the transmitter and operate the transmitter away from those external heat sources.
All batteries should be stored and operated away from external heat sources in reasonable temperature conditions for best performance.

Battery Life

| UHF| 1.x
---|---|---
2 mW/10 mW| 35 mW| 2 mW/10 mW| 30 mW
SB900B| 8:30 hours| 4:15 hours| 5:40 hours| 4:40 hours
alkaline| 8 hours| 3:30 hours| 5:30 hours| 3:45 hours

The values in this table are typical of fresh, high quality batteries. Battery runtime varies depending on the manufacturer and age of the battery.

Checking Battery Info

When using a Shure rechargeable battery, the receiver and transmitter home screens display the number of hours and minutes remaining.
Detailed information for the battery is displayed Battery menu of the transmitter: Utilities > Battery

  • Battery: The chemistry type of for the installed battery (Shure, Alkaline, Lithium, NiMH)
  • Bars: Indicates the number of bars displayed
  • Time: Battery runtime
  • Charge: Percentage of charge capacity
  • Health: Percentage of current battery health
  • Cycle Count: Total of the number of charging cycles for the installed battery
  • Temperature: Battery temperature reported in Celsius and Fahrenheit

Important Tips for Care and Storage of Shure Rechargeable Batteries

Proper care and storage of Shure batteries results in reliable performance and ensures a long lifetime.

  • Always store batteries and transmitters at room temperature
  • Ideally, batteries should be charged to approximately 40% of capacity for long-term storage
  • Regularly clean the battery contacts with an electrical contact cleaner designed for gold contacts and safe on plastics
  • During storage, check batteries every 6 months and recharge to 40% of capacity as needed

Tip: For additional rechargeable battery information, visit www.shure.com.

AA Batteries and Transmitter Runtime
Transmitters are compatible with the following AA battery types:

  • Alkaline
  • Nickel Metal Hydride (NiMH)
  • Lithium Primary

A 5­segment battery indicator representing the charge level of the transmitter battery is displayed on the screens of the trans­mitter and receiver. The following table contains the approximate remaining transmitter runtime in hours: and minutes.

Alkaline BatteriesSHURE AD2 Digital Handheld Wireless Microphone
Transmitter fig 9 SHURE AD2
Digital Handheld Wireless Microphone Transmitter fig 10

Installing the Battery Contact Cover

Use battery contact covers to prevent reflections from the battery contacts during broadcasts or live performances.

  1. Remove the transmitter handle.
  2. Pull gently on the antenna cover to remove it. Install a battery contact cover in its place.
  3. Reinstall the transmitter handle.SHURE AD2 Digital Handheld Wireless Microphone Transmitter fig 11

The Main menu organizes the available transmitter parameters into three categories:

  • Radio
  • Audio
  • Utilities

Tips for Editing Menu Parameters

  • To access the menu options from the home screen, select enter. Select enter again to access the menu parameters. A menu parameter will blink when editing is enabled
  • To increase, decrease or change a parameter, use the arrow buttons
  • To save a menu change, select enter
  • To exit a menu without saving a change, select exit

Menu Map

Radio Menu

Freq

Press the enter button to enable editing of a group (G:) channel (C:) or frequency (MHz). Use the arrow buttons to adjust the values. To edit the frequency, press the enter button once to edit the first 3 digits, or twice to edit the second 3 digits.

Power

Higher RF power settings can extend the range of the transmitter.
Note: Higher RF power settings decrease battery runtime.

Output

Sets the RF output to On or Mute.
On: RF signal is active
Mute: RF signal is inactive

Audio Menu

Offset

Adjust the Offset level to balance mic levels when using two transmitters or when assigning multiple transmitters to receiver slots. Adjustment range: -12 dB to +21 dB.

Mute

When enabled, the power switch is configured as a mute switch for the audio:
Power switch on  Audio signal on
Power switch off: Audio signal muted
Exit mute mode to return the power switch to its normal functionality.

Tone Gen

The transmitter will generate a continuous test tone:
Freq: The tone can be set to 400 Hz or 1000 Hz.
Level: Adjusts the output level of the test tone.

Utilities Menu

Device ID
Assign a device ID of up to 9 letters or numbers.

Locks

Locks the transmitter controls and power switch.
None: The controls are unlocked
Power: The power switch is locked
Menu: The menu parameters are locked
All: The power switch and menu parameters are locked

Marker
When enabled, press the enter button to drop a marker in Wireless Workbench.

Battery

Displays battery information:
Battery Life: Runtime reported in bar display and time (hours:minutes)
Charge: Percentage of charge capacity
Health: Percentage of current battery health
Cycle Count: Total of the number of charging cycles for the installed battery
Temperature: Battery temperature reported in Celsius and Fahrenheit

About

Displays the following transmitter information:
Model: Displays the model number
Band: Displays the tuning band of the transmitter FW
Version: Installed firmware
HW Version: Hardware version
Serial Num: Serial number

Reset All

Restores all transmitter parameters to factory settings.

IR Sync

Use IR Sync to form an audio channel between the transmitter and receiver.
Note: The receiver band must match the band of the transmitter.

  1. Select a receiver channel.
  2. Tune the channel to an available frequency using group scan or manually turn to an open frequency.
  3. Power on the transmitter.
  4. Press the SYNC button on the receiver.
  5. Align the IR windows between the transmitter and the receiver so that the IR LED illuminates red. When complete, Sync Success! appears. The transmitter and receiver are now tuned to the same frequency.SHURE AD2 Digital Handheld Wireless Microphone Transmitter fig 13

Note: Any change to the encryption status on the receiver (enabling/disabling encryption) requires a sync to send the settings to the transmitter. New encryption keys for the transmitter and receiver channel are generated on every IR sync, so to request a new key for a transmitter, perform an IR sync with the desired receiver channel.

Setting the Frequency Manually

The transmitter can be manually tuned to a specific group, channel, or frequency.

  1. Navigate to the Radio menu and select Freq.
  2. Scroll to select G: and C: to edit the group and channel, or select the frequency parameter (MHz). When editing the fre­quency, press enter once to edit the first 3 digits, or twice to edit the last 3 digits.
  3. Use the ∧∨ buttons to adjust the group, channel, or frequency.
  4. Press enter to save, and then press exit when finished.

Updating Firmware

Firmware is embedded software in each component that controls functionality. Periodically, new versions of firmware are devel­oped to incorporate additional features and enhancements. To take advantage of design improvements, you can upload and in­stall new versions of the firmware by using the Shure Update Utility, available on the Shure Update Utility page.

Firmware Versions
When performing an update, first download firmware to the receiver, and then update transmitters to the same firmware version to ensure consistent operation.
The firmware numbering for Shure devices uses the following format: MAJOR.MINOR.PATCH (e.g., 1.2.14). At a minimum, all devices on the network (including transmitters), must have the same MAJOR and MINOR firmware version numbers (e.g., 1.2.x).

Updating the Transmitter

  1. Download the firmware to the receiver.

  2. Access the following menu from the receiver: Device Configuration > Tx Firmware Update.

  3. Align the IR ports between the transmitter and the receiver. IR ports must be aligned for the entire download, which can take 50 seconds or longer.
    Tip: The red alignment LED will turn on when the alignment is correct.

  4. Press ENTER on the receiver to begin the download to the transmitter. The receiver will display the progress of the up­date as a percentage.

RF Mute

RF Mute prevents transmission of the audio by suppressing the RF signal while allowing the transmitter to remain on. The home screen displays RF MUTED in this mode.

  1. From the Radio menu, navigate to Output.
  2. Choose one of the following options:
    • On: RF signal is active
    • Mute: RF signal is disabled
  3. Press enter to save.

Turning the transmitter off and on or replacing the battery will restore Output to On.

Safe Start

Power on in Safe Start mode to prevent interference with other devices. Hold the exit button while powering on your device un­til the Safe Start menu appears.

Safe Start menu options:

  • RF: Mute or On
  • Locks: None, Pwr, Menu, All

Use the navigation buttons to make changes.
Tip: To exit the Safe Start menu, cycle the power or momentarily remove the battery.
Note: Previous settings for locks and RF will be retained when the transmitter is powered on in Safe Start.

Input Overload

The OVERLOAD message is displayed when the audio input experiences a high- level input signal. Reduce the input signal or move mic away from the source to remove the overload.

Tone Generator

The transmitter contains an internal tone generator that produces a continuous audio signal. The tone is helpful when conduct­ing a sound check or for troubleshooting the audio signal chain. The level of the tone is adjustable from -60 dB to 0 dB and the frequency can be set to 400 Hz or 1000 Hz.
Tip: Always start with the level set to -60 dB to avoid overloading speakers or headphones.

  1. From the Audio menu select Tone Gen.
  2. Set the frequency to 400 Hz or 1000 Hz.
  3. Select Level and use the arrow buttons adjust the value between -60 dB and 0 dB.

Turn off the tone by selecting Off from the menu or by cycling the transmitter power.

Matching Audio Levels with Offset

When linking two or more transmitters to a receiver, there may be a difference in volume levels between microphones or instru­ments. If this occurs, use the Offset function to match the audio levels and eliminate audible volume differences between trans­mitters. If using a single transmitter, set Offset to 0 dB.

  1. Turn on the first transmitter and perform a sound check to test the audio level.
  2. Turn off the transmitter when finished. Turn on the second transmitter and perform a sound check to test the audio level. Repeat for any additional transmit­ters.
  3. If there is an audible difference in the sound level between the transmitters, navigate to the Offset menu (Audio > Offset) in the transmitter to increase or decrease the Offset in realtime to match the audio levels.

Troubleshooting

Issue See Solution…

No sound

| Power, Cables, Radio Frequency, or Encryp­

tion Mismatch

Faint sound or distortion| Gain, Cables
Lack of range, unwanted noise bursts, or dropouts| Radio Frequency (RF)
Cannot turn transmitter off or change frequency settings, or can’t pro­

gram receiver

|

Interface Locks

Encryption Mismatch message| Encryption Mismatch
Firmware Mismatch message| Firmware Mismatch
Transmitter Battery Hot message| Tx Battery Hot
Issue| See Solution…
---|---
Antenna Fault Red LED| RF
Handheld transmitter shuts down during use| Clean Battery Contacts

Power
Make sure that the receiver and transmitter are receiving sufficient voltage. Check the battery indicators and replace the trans­mitter batteries if necessary.

Gain
Adjust the system gain on the front of the receiver. Ensure the output level on the back of the receiver corresponds to the mic/line input setting of the mixing console, amplifier, or DSP.

Cables
Check that all cables and connectors are working correctly.

Interface Locks
The transmitter and the receiver can be locked to prevent accidental or unauthorized changes. A locked feature or button will produce the Locked screen on the LCD panel or the lock icon will flash on a transmitter.

Encryption Mismatch
Re-sync all receivers and transmitters after enabling or disabling encryption.

Firmware Mismatch
Paired transmitters and receivers must have the same firmware version installed to ensure consistent operation. See Firmware topic for firmware update procedure.

Tx Battery Hot
If the transmitter battery does not cool off, the transmitter will shut down. Let the device cool down and then consider swapping the transmitter battery to continue operation.
Identify any possible external heat sources to the transmitter and operate the transmitter away from those external heat sources.
All batteries should be stored and operated away from external heat sources in reasonable temperature conditions for best performance.

Radio Frequency (RF)

RF LEDs
If neither blue RF Diversity LED is illuminated, then the receiver is not detecting the presence of a transmitter.
The orange RF Signal Strength LEDs indicate the amount of RF power being received. This signal could be from the transmit­ter, or it could be from an interfering source, such as a television broadcast. If more than two of the orange RF LEDs are still illuminated while the transmitter is off, then that channel may be experiencing interference, and you should try a different channel.

The red RF LED indicates RF overload. Overloads have the potential to cause interference in multiple system installations. If you are experiencing an overload, turn off the receiver to see if it is causing interference with other components.
The numerical channel select button also turns red to indicate interference.

  • Dim red = Channel is not selected, experiencing interference
  • Bright red = Channel is selected, experiencing interference

Compatibility

  • Perform a Scan and Sync to ensure the transmitter and receiver are set to the same group and channel.
  • Look at the band label on the transmitter and make sure the receiver is set to the same band.

Reducing Interference

  • Perform a group or channel scan to find the best open frequency. Perform a sync to transfer the setting to the transmitter.
  • For multiple systems, check that all systems are set to channels in the same group (systems in different bands do not need to be set to the same group).
  • Maintain a line of sight between transmitter and receiver antennas.
  • Move or point receiver antennas away from metal objects or other sources of RF interference (such as LED walls, comput­ers, digital effects, network switches, network cables and Personal Stereo Monitor (PSM) wireless systems).
  • Eliminate RF overload (see below).

Increasing Range

If the transmitter is more than 6 to 60 m (20 to 200 ft) from the receiver antenna, you may be able to increase range by doing one of the following:

  • Reduce interference (see above).
  • Increase transmitter RF power level.
  • Use Normal mode instead of High Density mode.
  • Use an active directional antenna, antenna distribution system, or other antenna accessory to increase RF range.

Eliminating RF Overload

If you see the red RF LED on a receiver, try the following:

  • Reduce the transmitter RF power level
  • Move the transmitter further away from the receiver—at least 6 m (20 ft)
  • If you are using active antennas, reduce antenna or amplifier gain.
  • Use omnidirectional antennas

Antenna Faults
The Antenna Fault red LED indicates a short circuit condition or excessive load at an antenna port.

  • Check antennas and cables for damage
  • Ensure that antenna ports are not overloaded
  • Check antenna bias voltage setting. Turn off voltage if using passive antennas.

Clean Battery Contacts
Clean the battery contacts with an electrical contact cleaner designed for gold contacts and safe on plastics.

Contact Customer Support
Didn’t find what you need? Contact our customer support to get help.

Specifications

Mic Offset Range
­12 to 21 dB (In 1 dB steps)
Battery Type
Shure SB900B Rechargeable Li­Ion or LR6 AA batteries 1.5 V
Battery Runtime
@ 10 mW

Shure SB900B up to 8:30 hours
alkaline up to 8 hours

See Battery Runtime Chart

Dimensions
256 mm x 51 mm (10.1 in. x 2.0 in.) L x Dia.

Weight
340 g (12.0 oz.), Without Battery

Housing
Cast Aluminum

Operating Temperature Range
-18°C (0°F) to 50°C (122°F)
Note: Battery characteristics may limit this range.

Storage Temperature Range
-29°C (-20°F) to 74°C (165°F)
Note: Battery characteristics may limit this range.

Audio Input
Configuration Unbalanced

Maximum Input Level
1 kHz at 1% THD
145 dB SPL (SM58), typical

Note: Dependent on microphone type

RF Output

Antenna Type
Integrated Single Band Helical

Occupied Bandwidth
<200 kHz

Channel-to-Channel Spacing

Standard Mode 350 kHz
High-Density Mode 125 kHz

varies by region

Modulation Type
Shure Axient Digital Proprietary

Power
2 mW, 10 mW, 35 mW

See Frequency Range and Output Power table which varies by region

Specific Absorption Rate (SAR) < 0.19 W/kg

Frequency Range and Transmitter Output Level

SHURE AD2 Digital Handheld
Wireless Microphone Transmitter fig 20SHURE AD2 Digital Handheld Wireless Microphone
Transmitter fig 21

With a gap between 608 to 614 MHz.
With a gap between 608 to 614 MHz and a gap between 616 to 653 MHz.
Power delivered to the antenna port.
† Operation mode varies according to region. In Brazil, High-Density mode is used. The maximum power level for Peru is 10mW.
††Limited to 10mW for Indonesia.
†††Z16 for Japan only

  • Output power limited to 10 mW above 608 MHz.
  • Korea defines power as conducted (ERP) which is 1dB less then declared in table.

K55 606-694 MHz

Country Code Frequency Range
A, B, BG, CH, CY, CZ, D, DK, EST, F *
FIN, GB, GR, H, HR, I, IRL, IS, L, LT *
M, N, NL, P, PL, RO, S, SK, SLO, TR *
Country Code Frequency Range
--- ---
all other countries *
  • This equipment may be capable of operating on some frequencies not authorized in your region. See Licensing Information.

G56 470-636 MHz

Country Code Frequency Range
A, B, BG, CH, CY, CZ, D, DK, EST, F *
FIN, GB, GR, H, HR, I, IRL, IS, L, LT *
M, N, NL, P, PL, RO, S, SK, SLO, TR *
all other countries *
  • This equipment may be capable of operating on some frequencies not authorized in your region. See Licensing Information

K57 606-790 MHz

Country Code Frequency Range
A, B, BG, CH, CY, CZ, D, DK, EST, F *
FIN, GB, GR, H, HR, I, IRL, IS, L, LT *
M, N, NL, P, PL, RO, S, SK, SLO, TR *
  • This equipment may be capable of operating on some frequencies not authorized in your region. See Licensing Information. Please follow your regional recycling scheme for batteries, packaging, and electronic waste.
    No user­operated control of power, frequency, or other parameters are available beyond those specified in this operating man­ual.

WARNING

  • Battery packs may explode or release toxic materials. Risk of fire or burns. Do not open, crush, modify, disassemble, heat above 140°F (60°C), or incinerate.
  • Follow instructions from the manufacturer
  • Only use the Shure charger to recharge Shure rechargeable batteries
  • WARNING: Danger of explosion if battery incorrectly replaced. Replace only with the same or equivalent type.
  • Never put batteries in your mouth. If swallowed, contact your physician or local poison control center
  • Do not short circuit; may cause burns or catch fire
  • Do not charge or use battery packs other than Shure rechargeable batteries
  • Dispose of battery packs properly. Check with local vendors for proper disposal of used battery packs.
  • Batteries (battery pack or batteries installed) shall not be exposed to excessive heat such as sunshine, fire or the like Do not immerse the battery in liquid such as water, beverages, or other fluids.
  • Do not attach or insert the battery with polarity reversed.
  • Keep away from small children.
  • Do not use abnormal batteries.
  • Pack the battery securely for transport.

Note: Use only with the included power supply or a Shure-approved equivalent.
WARNING: Danger of explosion if incorrect battery replaced. Operate only with AA batteries.

LICENSING INFORMATION

Licensing: A ministerial license to operate this equipment may be required in certain areas. Consult your national authority for possible requirements. Changes or modifications not expressly approved by Shure Incorporated could void your authority to operate the equipment. Licensing of Shure wireless microphone equipment is the user’s responsibility, and licensability de­pends on the user’s classification and application, and on the selected frequency. Shure strongly urges the user to contact the appropriate telecommunications authority concerning proper licensing, and before choosing and ordering frequencies.

Australia Warning for Wireless
This device operates under an ACMA class license and must comply with all the conditions of that license including operating frequencies. Before 31 December 2014, this device will comply if it is operated in the 520-820 MHz frequency band.
WARNING: After 31 December 2014, in order to comply, this device must not be operated in the 694-820 MHz band.

Certifications
Certified under FCC Part 15 and FCC Part 74.
Certified by ISED in Canada under RSS-210.
FCC ID: DD4AD2G55, DD4AD2G57, DD4AD2K53, DD4AD2K54, DD4AD2X55. IC: 616A- AD2G55, 616A-AD2K53. Meets essential requirements of the following European Directives:

  • WEEE Directive 2012/19/EU, as amended by 2008/34/EC
  • RoHS Directive EU 2015/863
    Note: Please follow your regional recycling scheme for batteries and electronic waste

This product meets the Essential Requirements of all relevant European directives and is eligible for CE marking.

CE Notice: Hereby, Shure Incorporated declares that this product with CE Marking has been determined to be in compliance with European Union requirements. The full text of the EU declaration of conformity is available at the following site: https://www.shure.com/en-EU/support/declarations-of- conformity.

Authorized European representative:
Shure Europe GmbH
Department: Global Compliance
Jakob-Dieffenbacher-Str. 12
75031 Eppingen, Germany
Phone: +49-7262-92 49 0
Fax: +49-7262-92 49 11 4
Email: [email protected]

Information to the user

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference.
  2. This device must accept any interference received, including interference that may cause undesired operation.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installa­tion. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This device operates on frequencies shared with other devices. Consult the Federal Communications Commission White Space Database Administration website to determine available channels in your area prior to operation.

Canada Warning for Wireless
This device operates on a no­protection, no­interference basis. Should the user seek to obtain protection from other radio ser­vices operating in the same TV bands, a radio license is required. For further details, consult Innovation, Science and Econom­ic Development Canada’s document Client Procedures Circular CPC­2­1­28, Voluntary Licensing of Licence­Exempt Low­Pow­er Radio Apparatus in the TV Bands.

  1. This device may not cause interference.
  2. This device must accept any interference, including interference that may cause undesired operation of the device.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Shure User Manuals

Related Manuals