OYA UPP-2400 2400W Portable Power Station User Manual
- June 1, 2024
- OYA
Table of Contents
2400W PORTABLE POWER STATION
100~120V/220~240V
User Manual
Disclaimer
- The Company is not responsible for any damage caused by force majeure (e.g. fire, typhoon, flood, earthquake or customer’s negligence, abuse or use in other unusual circumstances).
- The Company is not responsible for the loss caused by the use of non-standard connectors.
- The Company is not responsible for any damage caused by the wrong operation which didn’t follow the instructions of user manual.
Products List
No. | Items | Qty |
---|---|---|
1 | Portable Power Station | 1 |
2 | AC Adapter | 2 |
3 | 7909 connected wire for Vehicle’s 12V Output | 1 |
4 | User Manual | 1 |
5 | Warranty Card | 1 |
Function Instructions
3.1 Function Description
3.2 LCD Screen Description
Direction of Use
The LCD battery capacity circle indicates the residual capacity.
The circle has been divided into 6 equal segments, accounting for about
17%~35%~51%~68%~85%~100%. When discharging, the blue segments of the circle
will disappear according to the real-time residual capacity. When recharging,
the blue circle will be flashed in the clockwise direction, and the digital
number will show the real-time input charging power. After being fully
recharged, the whole blue circle will light up and remain stable, then please
unplug the adapter.
CAUTION
- There will be efficiency loss of the input power which displays on the LCD screen.
- Please charge the product at the ambient temperature of 0-40°C.
- Must make sure that the connection is in good contact , and E adapter work normally, otherwise, it may cause potential safety hazards. :
- In order to reduce the power consumption and prolong leathery lifetime of the product, please turn off all the switches when it is not in use.
4.1 3 Different Recharging Ways
4.1.1 Standard AC Adapter
Please connect the 7909 input charge port of the product and wall outlet with
our standard 2*200W AC Adapter , it will take about 6 hours be fully charged.
CAUTION
Please use our standard solar panels and adapters to charge the device, otherwise the device may not be charged ‘normally. In severe cases, the lifespan will be reduced, and the device may be damaged due to short circuit.
4.1.2 Car Charger
Please connect the input 7909 charging port and the vehicle’s 12V cigarette
output port with our standard 7909 transfer cable.
It will take at least 23 hours be fully charged.
4.1.3 Solar Panels
ANDERSON Input: Connect 2*220 Solar Panels with Anderson Y parallel cable, next connect Anderson Y parallel cable with the Anderson input port on the right side of 2400 power station. At the point, the battery indicator bar on the screen will start to scroll and the input power will be displayed, indicating that the power station is charging. The solar power is affected by the intensity of the light. The charging power increases with the increase of light intensity, and the Anderson port supports a maximum power input of 500W.
NOTE : The power station can not be charged until all the Anderson port is connected, supports up to 45V input voltage.
The 7909 DC port and the Anderson port can not be used at the same time. 7909 Input: Connect 2*220W Solar Panels with the 7909 DC input ports of 2400 power station. At the point, the battery indicator bar on the screen will start to scroll and the input power will be displayed, indicating that the power station is charging. The charging power increases with the increase of light intensity.
CAUTION
Please use our standard solar panels and adapters to charge the device, otherwise the device may not charge normally. In severe cases, the lifespan will be reduced, and the device may be damaged due to a short circuit.
4.2 AC Output Instructions
Main Power Switch
POWER ON: Long press the main power button for 3 seconds, the background
light around the button will lit up , and the LCD screen will light up too,
the blue battery circle and battery percentage will display.
POWER OFF: Long press the main power button for 3 seconds, the background
light and LCD screen will be off at the same time.
4.2.1 AC Output Instructions
When the main power button is turned on, gently press the AC Output button, the icon in the LCD screen will lit up. It means the function of this area can be used normally. Press this button again, the icon will disappear, and the function of this area will be turned off.
4.2.2 DC Output Instructions
When the main power button is on, press the DC button on the left side of the
function panel, USB-C and USB-A function can be used normally, and the
corresponding icons on the LCD screen will lit up. Press the DC
button on the right side of the function panel, USB-C and USB-A function can
be used normally, and the corresponding icons , on the LCD screen will lit up.
Press the power button again, the corresponding icons and onthe LCD screen
will go out, and the functions in the area be turned off.
4.3 LED Light Instructions
When the main power is on state, the power on/off button is on the other side. Press once, 50% brightness, press twice,100% brightness, then press thirdly, it will change to SOS flashing mode, and press once more to power off.
Appliances Run time instructions
Icons | Appliances | Run time |
---|---|---|
30Wh Tablet PC | 65.5 Times | |
10W Light | 196 Hours | |
1200W Electric Frying Pan | 1.6 Hours | |
1300W Microwave | 1.5 Hours | |
500W Washer | 3.9 Hours | |
60Wh Drone | 33 Times | |
120W Refrigerator | 16.3 Hours | |
1600W Hair Dryer | 1.2 Hours | |
1000W Coffee Maker | 2 Hours | |
110W 50″ TV | 18 Hours | |
40W CPAP | 49 Hours |
Frequency switching operation
- In the power-on state, turn off the AC output, and press the main power button & the DC button(USB output) at the same time to enter the switching frequency menu;
- Press the AC output button to switch the frequency, the setting frequency will be flashing;
- Long press the main power button to set the frequency, SUC will be displayed if the setting is successful, and then long press the main power button to exit the setting menu.
Storage and Maintenance
- When the device is not in use, please turn off all switches to reduce product power consumption and prolong the product battery lifetime;
- Please keep the surface of the product clean, ensure that the product does not contact gasoline, volatile oil, thinner, kerosene, etc., to avoid corrosion of the product shell;
- Please store the product in a dry, ventilated and dustless environment, in a 0-40°C temperature range and avoid direct sunlight;
- Please fully charged the battery before storage, and charge it at least once every 3~6 months, to avoid dormancy of the battery, which will affect normal use;
- If the product needs to be long-distance transported, please keep the battery power between 40%~60%, otherwise there will be potential safety risks.
Main Technical Specification
Output Technical Parameters
AC Output | Rated Voltage | 100-120Vac | 220-240Vac |
---|---|---|---|
Frequency | 60Hz | 50Hz | |
Rated Power | 2400W | ||
Peak Power | 5000W |
DC 12V & Car
lighter Output| Rated Voltage| 12V
Rated Power| 10A
USB-A Output| 5V/3A; 9V/2A; 12V/1.5A (18W Max) ; 5V/2A
USB-C Output| 5V/3A; 9V/3A; 12V/3A; 15V/3A; 20V/3A
LED Light| Press once, 50% brightness, press again, 100% brightness, then
press again, it will change to SOS flashing mode, and press once more to power
off.
Input
Input Voltage | 12V-45V |
---|---|
7909 Input Power | 2*24V/200W |
Anderson Input power | 2*45V/500W(Single maximum input 500W) |
Battery
Rated Capacity | 2232Wh | 697500mAh |
---|---|---|
Rated Voltage | 46.5Ah; 48V | |
Battery Type | LiFePO4 |
common information
IP Grade | IP21 |
---|---|
Working Temperature | 0~40°C |
Dimensions | 16.5%10.6%12.3in(420%270%313mm) |
Net Weight | 45.61b(20.7kg) |
Fault code and Trouble Shooting
Code | Description | Performance | Trouble Shooting |
---|---|---|---|
E000 | AC Short Circuit | ||
Protection | flashing, no output | Press the AC Output Power on/off button for |
recovery.
E001| Over Load
Production| flashing, no output| Flashing icons indicates which circuit
overload. Press corresponding button for recovery.
E002| Battery Low
Voltage
Protection| Related function icons flashing , Corresponding terminals no
output| Press corresponding button for recovery.
E003| AC&DC Output run simultaneously, system overload| flashing,
AC no output| AC&DC Output run at the same time, the total load power is over
2400 W. Shut down the AC output, or lower down the load of AC output, priority
support the DC output.
E004| Inverter fault| flashing, no output| Inverter output voltage too
high/low; Inverter over temperature; DC main line voltage too high/low; Loaded
current abnormal.
E005| BMS fault| flashing,
other function icons Can’t lit up, no output| Charge over voltage protection;
Discharge under voltage protection; High Temperature Protection; Low
Temperature Protection; Short Circuit Protection.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>