Luminoso LED BAL Series Area Light Installation Guide
- June 1, 2024
- Luminoso LED
Table of Contents
Luminoso LED BAL Series Area Light
WARNING
PLEASE READ ALL INSTRUCTIONS BEFORE ATTEMPTING INSTALLATION
- To prevent personal injury or product damage only licensed electricians should install.
- To avoid electric shock or component damage disconnect power before attempting installation or servicing.
- This product must be installed in accordance with the national electric code (NEC) and all applicable federal, state and local electric codes and safety standards.
- Disconnect product and allow cooling prior to servicing.
- Any alteration or modification of this product is expressly forbidden as it may cause serious personal injury, death, property damage and/or product malfunction.
- To prevent product malfunction and/or electrical shock this product must be properly grounded.
- This luminaire is designed to operate in ambient temperatures ranging from -40°C to 45°C and to be horizontally mounted with the LEDs facing down.
- This product must be installed in accordance with the applicable installation code by a Person familiar with the construction and operation of the product and the hazards involved.
- MIN 75°C SUPPLY CONDUCTORS
- CONSULT A QUALIFIED ELECTRICIAN TO ENSURE CORRECT BRANCH CIRCUIT CONDUCTOR
- CAUTION – RISK OF FIRE
- Adjustable Arm/Slipfitter/Yoke Mounted with PHOTOCELL function tilt angle should not exceed 15 degrees
- This product is not available for several special environments, such as places with corrosive gas liquids or high pressure water vapor.
Square/Round Pole Mount
- Remove the side plate from mounting bracket.
- Fix the bracket to the pole with 2pcs 3/8 screws
- Route the cord into mounting bracket through the hole for wiring,slide the fixture onto the bracket and tighten 2pcs bottom screws.
- Slightly drag the wires to make sure the hole on bracket is sealed by silicon gasket.
- Make wiring connection as per wire diagram below, replace the side plate and fasten screws.
Silicone gasket usage instructions:
First, only use silicone gasket A while using a round pole, Second,you need to
use two silicone gaskets at the same time while using a square pole.
OPEN Wall Mount
- Remove the side plate by loosen the screws.
- Fix the steel plate onto the mounting bracket with KM4*10 screws
- Use the back plate provided to locate footprint on the wall to drill the holes, then fix the bracket on the wall with screws
- Route the power cord into wall mount bracket, slide the fixture onto the mounting bracket, then tighten 2pcs bottom screws.
- Make wiring connection inside of bracket and replace the side plate with screws.
Yoke Mount
- Mount fixture onto surface using the hole pattern provided on the trunnion bracket.
- Loosen center bolts and set screw.
- Rotate fixture to desired aiming position and tighten center bolts.
- Make wiring connection as per wire diagram below.
- After fixing the bracket at certain angle, the four Hexagon socket screws should be locked by manual wrench
Adjustable Arm Mount
- Remove the bracket cover 6 pcs PM4*12 screws.
- Fix the bracket to the light pole with 2 pcs 1-3/8 screws.
- Loosen the screws of M10 and adjust the appropriate angle.
- Thread the fixture input wire through the bracket.
- Install the fixture on the bracket and lock the screws.
- Complete the wiring according to the wiring diagram.
- Arrange the power cord and install 2 face covers, taking care that the power cord is not exposed and does not press the wire.
Silicone gasket usage instructions:
First, only use silicone gasket A while using a round pole, Second,you need to
use two silicone gaskets at the same time while using a square pole.
Slipfitter Mount
- Connect the wires to L / N / GND
- Remove the cover and adjust the bracket to the desired angle
- Install the bracket on the pole and fix it with screws
Power and CCT selectable version
- Remove the 1/2″ screw plug on the bottom of the fixture.
- Select Power(White) and CCT(Black) by sliding the respective switch to the desired value according to the figure.
- Replace the 1/2″ screw plug and tighten with a flat head screwdriver.
ACCESSORY LIST
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>