Quimipool UNO Salt Chlorinator Instruction Manual

June 1, 2024
QUIMIPOOL

Quimipool UNO Salt Chlorinator

FUNCTIONS OF THE EQUIPMENT

Quimipool-UNO-Salt-Chlorinator-fig-1

INSTALLATION DIAGRAM

  • The electrical connections at cell level must not point upwards, to avoid any deposits of water or humidity on them.
  • The pH corrector container must be kept 2 meters away from any electrical device or any other chemicals. For acid fumes to be expelled outside the pool house, a venting system must be placed on the pH corrector’s hermetic cap. Failure to follow these instructions may lead to abnormal oxidation of metal parts, possibly resulting in complete device failure. Personal protective equipment (glasses with side protection, suitable gloves, refer to the product’s safety data sheet) must be worn whenever handling the pH corrector or the injection circuit.
  • Never use hydrochloric acid, as this may lead to irreversible damage to the device and void the warranty. Only use a sulphuric acid- or alkali-based pH corrector product recommended by your professional dealer. Please note that use of a multi-acid pH corrector requires increased maintenance, and its use may also lead to premature wear of the pH circuit and void the warranty. Refer to the product’s safety data sheet.

Quimipool-UNO-Salt-Chlorinator-fig-2Quimipool-
UNO-Salt-Chlorinator-fig-3

ELEMENTS NOT SUPPLIED

  1. Electrical power supply
  2. pH corrector container
  3. Copper cable
  4. Filter
  5. Ground rod
  6. Heat pump
  7. Filtration pump
  8. Venting system

ELECTRONICS UNIT

First commissioning
When switching on the electronics unit for the first time, carry out the following programming.Quimipool-UNO-Salt-Chlorinator-
fig-4

Keypad

Quimipool-UNO-Salt-Chlorinator-fig-5

LEDs

Colour Status Meaning
Green Continuously on Production in progress
Red Continuously on The electronics unit powered off, or the wintering mode

activated
Flashing| Alarm activated

Screen

  • If display flashing : information awaiting confirmation, or alarm activated.
  • If display solid : confirmed or read-only information.

Quimipool-UNO-Salt-Chlorinator-fig-6

  1. If the chlorinator operating mode is set to “%”.
  2. If the chlorinator operating mode is set to “ORP”.

Menu navigation

Quimipool-UNO-Salt-Chlorinator-fig-7

Features

Selecting the display language

Quimipool-UNO-Salt-Chlorinator-fig-8

Setting the date and time

Quimipool-UNO-Salt-Chlorinator-fig-9

Specification of the volume of the pool

Quimipool-UNO-Salt-Chlorinator-fig-10

Specification of the pH corrector type

Quimipool-UNO-Salt-Chlorinator-fig-11

Specification of the concentration of the pH corrector

Quimipool-UNO-Salt-Chlorinator-fig-12

Sensor settings

Quimipool-UNO-Salt-Chlorinator-fig-13

  • Ext cmd: external command.
  • pH Can: empty container sensor.
  • ON: sensor activated.
  • OFF: sensor disabled.
  • NO: switch normally open.
  • NC: switch normally closed.

Quimipool-UNO-Salt-Chlorinator-fig-14

Calibration of the water temperature measurement

  • If the temperature sensor is disabled, the menu below does not appear.

Quimipool-UNO-Salt-Chlorinator-fig-15

Calibration of the salt rate measurement
If the salt sensor is disabled, the menu below does not appear.Quimipool-
UNO-Salt-Chlorinator-fig-16

Calibration of the pH measurement

Quimipool-UNO-Salt-Chlorinator-fig-17

Setting the inversion frequency of the current supplying the cell

Current inversion aims to prevent scale deposits on the cell. Current inversion must be set following the table below in order to ensure that the cell continues to operate correctly in the long term.

Water hardness (°f)| 0 to 2| 2 to 5| 5 to 8| 8 to 12| 12 to 20| 20 to 40| 40 to 60| > 60
---|---|---|---|---|---|---|---|---
Water hardness (mg/L)| 0 to 20| 20 to 50| 50 to 80| 80 to 120| 120 to 200| 200 to 400| 400 to 600| > 600
Reversal frequency (h)| 24 to 16| 16 to 14| 14 to 12| 10| 8| 6| 4| 2

Quimipool-UNO-Salt-Chlorinator-fig-18

Selecting the chlorinator operating mode

Quimipool-UNO-Salt-Chlorinator-fig-44

  • The choice of operating mode can be seen on the initial display

Setting the production setpoint

Quimipool-UNO-Salt-Chlorinator-fig-20

Setting the pH setpoint

Quimipool-UNO-Salt-Chlorinator-fig-21

Setting the ORP setpoint

Quimipool-UNO-Salt-Chlorinator-fig-22

Boost mode

Boost mode

  • sets the production setpoint up to 125 %, for a fixed period.
  • can be manually stopped at any time.
  • can be used when chlorine is urgently needed.

Boost mode cannot replace a conventional shock treatment in cases of water not fit for bathing.3

  • If the Boost mode is restarted manually while it is already running, the Boost mode resets for the duration displayed.
  • Boost mode cannot be switched on if an alarm has been triggered. After having resolved and dismissed this alarm, wait a few moments in order to be able to activate the Boost mode.
  • When the Boost mode ends or is manually stopped, production continues according to the initial setpoint.
  • Boost mode continues after powering off the electronics unit.

Operation with a cover sensor :

  • Boost mode cannot be switched on with the cover shut.
  • If the cover is closed with Boost mode switched on, Boost mode automatically stops.Quimipool-UNO-Salt-Chlorinator-fig-23

Calibrating the probes : important advance information

  • The original pH probe is already calibrated. It is therefore not necessary to carry out calibration of the pH probe when putting the equipment into service for the first time.
  • However, it is imperative to carry out a calibration of the pH and ORP probes at the beginning of each season when returning to service, and after each probe replacement.

Calibrating the pH probe

  1. Open the pH 7 and pH 10 calibration solutions (use only single-use calibration solutions).
  2. Turn off the filtration (and therefore the electronics unit).
  3. If the probe is already installed :
    • Remove the probe from the probe holder, without disconnecting it.
    • Remove the probe holder nut and replace it with the stopper supplied. If the probe is not already installed: Connect the probe to the electronics unit.
  4. Turn on the electronics unit.
  5. Go to the « » menu.
  6. Navigate through the menus following the instructions below :Quimipool-UNO-Salt-Chlorinator-fig-25

Calibrating the ORP probe

  1. Open the ORP 475 mV calibration solution.
  2. Turn off the filtration (and therefore the electronics unit).
  3. If the probe is already installed :
    • Remove the probe from the probe holder, without disconnecting it.
    • Remove the probe holder nut and replace it with the stopper supplied. If the probe is not already installed: Connect the probe to the electronics unit.
  4. Turn on the electronics unit.
  5. Go to the « » menu.
  6. Navigate through the menus following the instructions below :Quimipool-UNO-Salt-Chlorinator-fig-27

Activation/deactivation of pH regulationQuimipool-UNO-Salt-Chlorinator-
fig-30

Manual injectionQuimipool-UNO-Salt-Chlorinator-
fig-31

Bluetooth communicationQuimipool-UNO-Salt-Chlorinator-
fig-45

  • During an update of the software of the electronics unit carried out using Bluetooth, the 2 LEDs (red and green) flash alternately.

Chlorination test
This function is for use by professionals for maintenance operations on the equipment.

Quimipool-UNO-Salt-Chlorinator-fig-32

Settings reset

Quimipool-UNO-Salt-Chlorinator-fig-33

Safety

Wintering mode

  • is activated by default.
  • starts automatically as soon as the water temperature drops below 15°C.

When wintering mode is on :

  • The message « » is displayed.
  • Production is stopped.
  • The pH regulation is maintained if it is activated.

To switch off wintering mode : press on OK.
To disable wintering mode: go to the Quimipool-UNO-Salt-Chlorinator-
fig-35  menu.

Alarms

  • All alarms are activated by default.
  • Any alarm that is activated immediately appears on the screen.
  • To dismiss an alarm : press the OK or button (short or long press, depending on the alarm).

Quimipool-UNO-Salt-Chlorinator-fig-36 Quimipool-UNO-Salt-Chlorinator-fig-37 Quimipool-UNO-Salt-Chlorinator-fig-38Quimipool-
UNO-Salt-Chlorinator-fig-39

Important precautions regarding the peristaltic pump

When one of the 2 messages below is displayed, the peristaltic pump is running.

In this case, never remove the front panel of the electronics unit.

If case of doubt about the correct functioning of the peristaltic pump

  1. Switch off the electronics unit.
  2. Remove the front cover of the electronics unit.
  3. Remove the flexible hose inside the peristaltic pump.
  4. Carry out a manual vacuum injection.

Further information

Quimipool-UNO-Salt-Chlorinator-fig-41

GUARANTEE

Before contacting your dealer, please have the following to hand :

  • your purchase invoice.
  • the serial no. of the electronics unit.
  • the installation date of the equipment.
  • the parameters of your pool (salinity, pH, chlorine levels, water temperature, stabilizer level, pool volume, daily filtration time, etc.)

Every effort and all our technical experience has gone into designing this equipment. It has been subjected to quality controls. If, despite all the attention and expertise involved in its manufacture, you need to make use of our guarantee, it only applies to free replacement of the equipment’s defective parts (excluding shipping costs in both directions).

Guarantee period (proven by date of invoice)

Electronics unit: 2 years.
Cell:

  • 1 year minimum outside the European Union (excluding warranty extension).
  • 2-year minimum in the European Union (excluding warranty extension).
  • Probes: depending on the model.
  • Repairs and spare parts : 3 months.

The periods indicated above correspond to standard guarantees. However, these can vary depending on the country of installation and the distribution network.

Scope of the guarantee
The guarantee covers all parts, except wearing parts that must be replaced regularly. The equipment is guaranteed against all manufacturing defects within the strict limitations of normal use. Never use hydrochloric acid, as this may lead to irreversible damage to the device and void the warranty. Only use a sulphuric acid- or alkali-based pH corrector product recommended by your professional dealer. Please note that the use of a multi-acid pH corrector requires increased maintenance, and its use may also lead to premature wear of the pH circuit and void the warranty. Refer to the product’s safety data sheet.

After-sales services
All repairs will be performed in the workshop. Shipping costs in both directions are at the user’s own expense. Any downtime and loss of use of a device in the event of repairs shall not give rise to any claim for compensation. In all cases, the equipment is always sent at the user’s own risk. Before taking delivery, the user must ensure that it is in perfect condition and, if necessary, write down any reservations on the shipping note of the carrier. Confirm with the carrier within 72 hours by recorded letter with acknowledgment of receipt. Replacement under guarantee shall in no case extend the original guarantee period.

Guarantee application limit
To improve the quality of their products, the manufacturer reserves the right to modify the characteristics of the products at any time without notice. This documentation is provided for information purposes only and is not contractually binding concerning third parties. The manufacturer’s guarantee, which covers manufacturing defects, should not be confused with the operations described in this documentation. Installation, maintenance, and, more generally, any servicing of the manufacturer’s products should only be performed by professionals. This work must also be carried out by the current standards in the country of installation at the time of installation. The use of any parts other than the original parts voids the guarantee ipso facto for the entire equipment. The following are excluded from the guarantee :

  • Equipment and labor are provided by third parties when installing the device.
  • Damage caused by installation, not in compliance with the instructions.
  • Problems caused by modifications, accidents, misuse, negligence of professionals or end users, unauthorized repairs, fire, floods,

lightning, freezing, armed conflict or any other force-majeure events. Any equipment damaged due to non-compliance with the instructions regarding safety, installation, use, and maintenance contained in this documentation will not be covered by the guarantee. Every year, we make improvements to our products and software. These new versions are compatible with previous models. The new versions of hardware and software cannot be added to earlier models under the guarantee.

Implementation of the guarantee
For more information regarding this guarantee, contact your dealer or our After-Sales Service. All requests must be accompanied by a copy of the purchase invoice.

Legislation and disputes
This guarantee is subject to French law and all European directives or international treaties in force at the time of the claim, applicable in France. In case of disputes concerning its interpretation or execution, the High Court of Montpellier (France) shall have exclusive jurisdiction.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals