boqi DMX512 Universal RDM Enabled Decoder Instruction Manual

June 1, 2024
boqi

boqi DMX512 Universal RDM Enabled Decoder

boqi DMX512 Universal RDM Enabled Decoder

Function introduction

Important: Read All Instructions Prior to Installation

Function introduction

Product Data

No. Input Voltage Output Current Output Power Remarks Size(LxWxH)
1 12-48VDC 4x5A@12-36VDC

4×2.5A@48VDC

| 4x(60-180)W@12-36VDC

4x120W@48VDC

| Constant voltage| 178x46x22mm
2| 12-48VDC| 4x350mA| 4x(4.2-16.8)W| Constant current| 178x46x22mm
3| 12-48VDC| 4x700mA| 4x(8.4-33.6)W| Constant current| 178x46x22mm

  • Standard DMX512 compliant control interface.
  • Supports RDM function.
  • 4 PWM output channels.
  • DMX address manually settable.
  • DMX channel quantity from 1CH~4CH settable.
  • Output PWM frequency 2KHz
  • Output dimming curve gamma value from 0.1 ~ 9.9 settable.
  • To work with power repeater to expand output power unlimitedly.
  • Waterproof grade:IP20.

Safety & Warnings

  • DO NOT install with power applied to device.
  • DO NOT expose the device to moisture.

Operation

To set desired DMX512 address through buttons,
button A is to set “hundreds” position,
button B is to set “tens” position,
button C is to set “unit” position.

Set DMX address (Factory default DMX address is 001)
Press and hold down any of the 3 buttons for over 3 seconds, digital display flashes to enter into address setting, then keep short pressing button A to set “hundreds” position, button B to set “tens” position, button C to set “units” position, then press and hold down any button for >3 seconds to confirm the setting.

DMX signal indicator  (the digit 0 of “hundreds” position of DMX address) : When DMX signal input is detected, the digit 0 of “hundreds” position of DMX address will stay solid on. If there is no signal input, the digit 0 of “hundreds” position of DMX address will blink.

Choose DMX Channel (Factory default DMX channel is 4CH)
Press and hold down both buttons B+C simultaneously for over 3 seconds, CH digital display flashes, then keep short pressing button A to choose 1/2/3/4, which means total 1/2/3/4 channels. Press and hold down button A for >3 seconds to confirm the setting. Factory default is 4 DMX channels.

For example the DMX address is already set as 001.
1CH=1 DMX address for all the output channels, which all will be address 001.
2CH=2 DMX addresses , output 1&3 will be address 001, output 2&4 will be address 002
3CH=3 DMX addresses, output 1, 2 will be address 001, 002 respectively, output 3&4 will be address 003
4CH=4 DMX addresses, output 1, 2, 3, 4 will be address 001, 002, 003, 004 respectively

PWM frequency (2KHz)
PWM frequency is fixed @ 2KHz and can not be changed.

Choose Dimming Curve Gamma Value (Factory default dimming curve value is g1.5)
Press and hold down all buttons A+B+C simultaneously for over 3 seconds, digital display flashes g1.5, 1.5 means the dimming curve gamma value, the value is selectable from 0.1-9.9, then keep short pressing button B and button C to select corresponding digits, then press and hold down both buttons B+C for >3 seconds to confirm the setting.
Choose Dimming Curve Gamma Value \(Factory default dimming curve value is
g1.5\)

Firmware OTA update

You will get this after power on the decoder, it means this decoder supports firmware OTA update function. This function can be used when there is a firmware update from the manufacturer, the update can be executed through a Windows computer and an USB to serial port converter, the converter will connect the computer and the decoder’s hard wire DMX port. A software RS485-OTW on the computer will be used to push the firmware to the decoder.

Connect the computer and the decoder through the USB to serial port converter, if you need to update multiple decoders’ firmware, connect the converter to first decoder’s DMX port, then connect other decoders to the first decoder in daisy chain through the DMX port. Please do not power on the decoders.

Run the OTA tool RS485-OTW on the computer, select the correct communication port “USB-SERIAL” , baud rate “250000”, and data bit “9”, use default settings for other configurations. Then click “file” button to select the new firmware from the computer, then click “Open Port”, the firmware will be loaded. Then click “Download Firmware”, the right side state column of the OTA tool will show “send link”. Then power on the decoders before “wait erase” displaying on the state column, the digital display of the decoders will show . Then “wait erase” will show on the state column, which means the updating starts. Then the OTA tool starts writing data to the decoders, the state column will show the progress, once writing data finishes, the digital display of the decoders will flash  , which means firmware updated successfully.

Restore to Factory Default Setting

Press and hold down both buttons A+C for over 3 seconds until the digital display turns off and then turns on
again, all settings will be restored to factory default.
Default settings are as follows:
DMX Address: 001
DMX Address Quantity: 4CH
PWM Frequency : PF2
Gamma : g1.5

RDM Discovery Indication:

When using RDM to discover the device, the digital display will flash and the connected lights will also flash at the same frequency to indicate. Once the display stops flashing, the connected light also stops flashing.

The supported RDM PIDs are as follows:

DISC_UNIQUE_BRANCH
DISC_MUTE
DISC_UN_MUTE
DEVICE_INFO
DMX_START_ADDRESS
IDENTIFY_DEVICE
SOFTWARE_VERSION_LABEL
DMX_PERSONALITY
DMX_PERSONALITY_DESCRIPTION
SLOT_INFO
SLOT_DESCRIPTION
MANUFACTURER_LABEL
SUPPORTED_PARAMETERS

Product Dimension

Product Dimension

Wiring diagram

  1. When total load of each receiver is not over 10A
    Wiring diagram

  2. When total load of each receiver is over 10A
    Wiring diagram

Symbols

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>