Table of Contents
Access & Power Integration
T1MK1F4 Trove1 Mercury Kits
Altronix/Trove1 Mercury Kits
Models Include:
T1MK1F4
4 Door Kit with Fused Outputs
The fully assembled kit includes:
– Trove1 enclosure with TM1 Altronix/Mercury backplane
– (1) eFlow4NB – Power Supply/Charger
– (1) VR6 – Voltage Regulator
– (1) ACM4 – Fused Access Power Controller
T1MK1F4S
4 Door Kit with Fused Outputs
The fully assembled kit includes:
– Trove1 enclosure with TM1 Altronix/Mercury backplane
– (1) eFlow4NB – Power Supply/Charger
– (1) VR6 – Voltage Regulator
– (1) ACM4 – Fused Access Power Controller
– (1) PDS8 – Dual Input Power Distribution Module
T1MK1F4D
4 Door Kit with PTC Outputs
The fully assembled kit includes:
– Trove1 enclosure with TM1 Altronix/Mercury backplane
– (1) eFlow4NB – Power Supply/Charger
– (1) VR6 – Voltage Regulator
– (1) ACM4CB – PTC Access Power Controller
T1MK1F4SD
4 Door Kit with PTC Outputs
The fully assembled kit includes:
– Trove1 enclosure with TM1 Altronix/Mercury backplane
– (1) eFlow4NB – Power Supply/Charger
– (1) VR6 – Voltage Regulator
– (1) ACM4CB – PTC Access Power Controller
– (1) PDS8CB – Dual Input Power Distribution Module
All components of these Trove kits are UL Listed as sub-assemblies.
Please refer to the included corresponding Sub-Assembly Installation Guides
for further information.
Installation Guide
All registered trademarks are the property of their respective owners.
Rev. T1MK022719
installing Company: _____ Service Rep. Name:
Address: __Phone #: _____
Overview:
Altronix Trove Mercury kits are pre-assembled and consist of Trove1M1
enclosure/backplane with factory-installed Altronix power supply/charger and
sub-assemblies. These kits also accommodate various combinations of Mercury
boards for up to four (4) doors in a single enclosure.
Configuration Chart:
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA
70/ANSI and with all local codes and authorities having jurisdiction.
The product is intended for indoor use only.
- Remove the backplane from the enclosure. Do not discard hardware.
- Mark and predrill holes in the wall to line up with the top two (2) keyholes in the enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the two upper screws; level and secure. Mark the position of the lower two holes. Remove the enclosure. Drill the lower holes and install the two fasteners. Place the enclosure’s upper keyholes over the three upper screws. Install the two lower screws and make sure to tighten all screws.
- Mount included UL Listed tamper switch (Altronix Model T112 or equivalent) in the desired location, opposite hinge. Slide the tamper switch bracket onto the edge of the enclosure approximately 2” from the right side (Fig. 1, pg. 2) Connect the tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device. To activate the alarm signal open the door of the enclosure.
- Position Mercury access controller modules over corresponding spacers and depress them onto snap-on spacers, Fig. 2, pg. 3.
- Refer to the eFlow Power Supply/Charger Installation Guide for eFlow4NB, and the corresponding Sub-Assembly Installation Guide for ACM4(CB), PDS8(CB), and VR6 for further installation instructions.
- Mount the backplane to the enclosure with hardware.
Hardware:
T1MK1F4 and T1MK1F4D: Configuration of Mercury Boards:
- Fasten snap-on spacers onto metal pens configuration (A), (B), (C), or (D) of the backplane depending on the access controller (Fig. 2, pg. 3).
- Position the access controller module over the corresponding spacers and depress it onto snap-on spacers (Fig. 2a, pg. 3).
- Mount the backplane to the enclosure with hardware.
Access Controller Position Chart for the Following Models:
Mercury Access Controller | Pem Mounting |
---|---|
EP1502, LP1502, MR52, MR16IN, MR16OUT | A |
EP1501, LP1501, MR51e, MR62e | B |
MR50 | C |
EP2500, LP2500, MUX8 | D |
T1MK1F4S and T1MK1F4SD: Configuration of Mercury Boards:
- Fasten snap-on spacers onto metal pens configuration (A), (B), (C), or (D) of the backplane depending on the access controller (Fig. 3, pg. 4).
- Position the access controller module over corresponding spacers and depress it onto snap-on spacers (Fig. 3a, pg. 4).
- Mount the backplane to the enclosure with hardware.
Access Controller Position Chart for the Following Models:
eFlow Power Supply/Chargers can be Controlled and Monitored while Reporting Power/Diagnostics from Anywhere over the Network…
LINQ2 – Network Communication Module
LINQ2 provides remote IP access to real-time data from eFlow power
supply/chargers to help keep systems up and running at optimal levels. It
facilitates fast and easy installation and set-up, minimizes system downtime,
and eliminates unnecessary service calls, which helps reduce the Total Cost of
Ownership (TCO) – as well as creates a new source of Recurring Monthly Revenue
(RMR).
Features:
- UL is Listed in the U.S. and Canada.
- Local or remote control of up to (2) two Altronix eFlow power output(s) via LAN and/or WAN.
- Monitor real-time diagnostics: DC output voltage, output current, AC & battery status/service, input trigger state change, output state change and unit temperature.
- Access control and user management: Restrict read/write, Restrict users to specific resources
- Two (2) integral network controlled Form “C” Relays.
- Three (3) programmable input triggers: Control relays and power supplies via external hardware sources.
- Email and Windows Dashboard notifications
- The event log tracks history.
- Secure Socket Layer (SSL).
- Programmable via USB or web browser – includes operating software and 6 ft. USB cable.
LINQ2 Mounts Inside any Trove Enclosure
Notes:
Trove1 Enclosure Dimensions (H x W x D approximate):
18” x 14.5” x 4.625” (457mm x 368mm x 118mm)