SZBECEN BC-M300 Beam Moving Head Light User Manual
- June 1, 2024
- szbecen
Table of Contents
- SZBECEN BC-M300 Beam Moving Head Light
- Specifications
- Safety Guidance and Parameters
- working environment
- Panel operation
- Menu structure
- Reset
- Channel description
- Common faults and use of attention
- Frequently Asked Questions
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SZBECEN BC-M300 Beam Moving Head Light
Specifications
- Model: BC-M300
- Power: 300W
- Type: Long Life Beam Moving Head Light
- Package Includes :
- 1 x beam moving headlight
- 1 x clamp
- 1 x handle
- 1 x safe cable
- 1 x power cable
- 1 x DMX cable
Please read this manual before use
Safety Guidance and Parameters
Attention
The equipment is well-packaged when it leaves the factory. Please follow
the user’s manual, and the machine failure is not covered by the warranty due
to human reasons
Safety guidance
Please keep this instruction manual as a basis for future consultation, and if
you sell this product to other users, please make sure that they also get it.
- The lamp is only suitable for indoor drying places.
- The installation and operation of the lamps should be carried out by professionals.
- Don’t let the child operate the machine.
- Use a safe rope when fixing the equipment, and hold up the bottom when moving the lamps.
- Equipment must be installed in a well-ventilated place, at least 50 cm from the adjacent level.
- Ensure that the vents are unobstructed to avoid overheating during lamp operation.
- Ensure that the supply voltage complies with the equipment supply voltage before operation.
- Please ground the electric conductor to prevent the electric shock.
- Do not operate lamps above 40°C.
- Do not connect the lamps directly to the dimming device.
- The new lamp may have little smoke or odor and will disappear after 15 minutes of operation.
- Do not place combustible items next to the lamps when running to prevent fire risk.
- Before opening the lamp, please carefully check whether the power cord is damaged. If there is any damage, please replace it immediately.
- The surface temperature of the lamp can reach 90°C, do not touch it with bare hands.
- Avoid flammable liquid, water, metal, and other electrical conductors from entering the lamp interior to avoid electric shock or fire. If any foreign body enters the lamp, please cut off the power supply immediately.
- Avoid operating in a dirty and dusty environment, and clean and maintain the lamps regularly.
- Do not touch the wire to prevent electric shock.
- Avoid winding the power cord with other wires.
- The distance between the lamp and the irradiation surface shall be greater than 12M.
- Disconnect the power supply before replacing the fuse or light bulb.
- Use the same model when replacing the fuse or light bulb.
- If severe operation failure occurs, please stop the use immediately.
- Do not turn on the lamp repeatedly.
- Please replace the lamp shell, lens, or UV filter.
- There are no available parts inside the lamp, do not open the lamp shell without authorization
- Do not operate the machine by yourself. The non-professional operation will cause damage to the equipment or functional failure. If maintenance is needed, please contact the nearest authorized service center.
- Cut off the power supply when the lamps are not used or repaired for a long time.
- To avoid fire or electric shock, do not expose the lamps to rain or wet areas.
technical parameter
- Light source: PHILIPS MSD Silver 300LL
- Color temperature: 7,800 K
- Average life span: 4,000 H
- Rated voltage : AC 90V-250V 50Hz-60Hz
- Power: 450W
- Fuse: 6.3A
- Dimming : independent dual-chip device, 0-14 times / second ultra-fast strobe, 0-100% linear adjustment.
- Color: 13 color slices + white light, can realize half-color, full color, single and two-color gradients, and positive and negative direction slow fast rainbow effect, with hall, magnet positioning, and automatic error correction at any Angle.
- Static pattern: a metal pattern plate with 13 patterns + a white circle, which can realize the conversion effect of water, jitter, random movement and slow positive and negative direction. Imported special high temperature resistant metal materials, with the function of Hall, magnet positioning, and automatic error correction at any Angle.
- Prism: 8 + 16 + 24 honeycomb prism, 8 prism, prism can be superimposed, can be rotated in both directions, prism without black dot, prism superposition is still clear.
- Seven-color tablet: 1 seven-color slice (can make colorful effect)
- Fogging: 1 atomization effect, soft and natural light spot
- X-axis running angle: 540° 16bit precision scan
- Y-axis running Angle: 270° 16bit precision scan
- Automatic correction of loss of step in X-axis / Y axis
- Control channel: 16 CH channel
- Control signal: international standard DMX512 / RDM function
- Fan: Intelligent control, all fans do not work when the bulb is not working.
- Appearance: high-temperature-resistant plastic
- Protection level: IP20
- Product size : 31.6x23x53.8cm
- Net weight : 14kg
working environment
- Maximum ambient temperature: 40°C
- Minimum operating temperature: 0°C
- Maximum surface temperature: 70°C
- Protection level: IP20
Factory configuration
- Electronic instruction manual power line
- Factory qualification certificate and warranty card
Eight advantages
- Power-on operation and reset channel mute
- The XY is running at a high rotational speed
- Precise positioning does not deviate
- RDM remote tune address code,
- Intelligent detection and obstacle estimation
- Manual obstruction of shaking the head can be released intelligently
- Prism without black dots, prism stack is still clear prism autofocus
- High light transmittance combination mirror, strong light sense, full light beam
Precautions for products
- To ensure the service life of the product, the product should not be placed in a wet or leaky place, nor to work in temperatures above 60 degrees
- Do not place the product in a place that is easy to loosen or vibrate.
- To avoid the danger of electric shock, this product.
- When the bulb is used, the voltage change of the power supply should not exceed ± 10%. If the voltage is too high, it will shorten the life of the bulb. If the voltage is too low, it will affect the light color of the bulb.
- After a power failure, it takes 20 minutes to use the lamp to cool adequately before energizing again.
- To ensure the normal use of this product, please read the instructions carefully. Signal line connection (DMX)
Use specification-compliant RS-485 cable: with shielding, 120 ohm characteristic impedance, 22-24 AWG, and low tolerance. Do not use microphone cables or cables with different specified characteristics. The terminals must have a 3-or 5-pin XLR male/female connector.(Minimum of 1 / 4 W).
Important : The ines shall not contact each other or with the metal shell .
1Figure 1 Schematic diagram of the DMX signal line connection
Panel operation
Menu desktop
Menu first interface
- Address: Click to enter the address code setting
- Settings: Click to enter the system Settings
- Manual: Click to enter the manual mode
- Calibration: Click to enter the password to enter the system calibration mode
- Advanced: Click to enter the spotlight and system reset mode
- Information: Click on enter to view the system information
Menu structure
primary menu | Sublevel menu | Three-level menu / parameters |
---|---|---|
address | 001 – 512 | (Number of channels added each |
time, minus normal)
System Settings
| running mode| DMX / voice / self
channel pattern| 16CH
Default position of X axis| 0-255
Default position of Y axis| 0-255
X axis reversal| Open / close
Y axis reversal| Open / close
XY axis exchange| Open / close
The signal to keep| Open / close
Linear change in color| Open / close
Optical coupling error correction| Open / close
Hall error correction| Open / close
Screen protection| Open / close
Backlit time| Chang Liang / 15s / 30s / 60s
Screen reversal| Normal / reverse / automatic
language| centre /EN
Synchronous update| Execute updates
factory data reset| Confirm / cancel
manual mode| Current channel mode
channel
| 0-255
system calibration| enter password| Lighting calibration
lamp bulb| Turn on the light| Open / close
| Manual lighting| Open / close
| half-power| Open / close
| Clear the record| Confirm / cancel
| Light time|
| The number of lights|
system reset
| Head motor reset
XY motor reset
Full motor reset
system info
| Reset the error message| Display the reset error message
---|---|---
And DMX data
monitoring
| Channel values for the receiving
console
sensor information
| Hall information
X-light coupling information
Y light coupling information
Hardware version| Displays the hardware version
software release| Displays the software version
utility time| Time of the beam lamp
Screen automatic rotation function
The system can automatically rotate the screen according to the direction of
gravity, without manual rotation. You can also turn off the automatic rotation
function.
Manual control
- This interface is used to control the current lamps.
- Press OK to enter the edit state.
- Press Up and Down to change the channel value.
- Press OK again to save the modified value, and exit editing, and press Exit not to save the modified value, and directly exit editing.
System calibration
Here to set a layer of passwords to prevent non-professionals from
misoperation. The default password is “2021”, the default is directly press
the “OK” key to enter.
option | explain |
---|
Initial position calibration
| After entering the sub-interface, the starting position of X-axis, Y-axis, strobe, strobe, color disk, pattern, prism, fog mirror, colorful, focusing motor can be adjusted to make up for the error on the hardware installation. The adjustment range of 0~255,127 means that there is no
adjustment.
Travel calibration
| After entering the sub-interface, the stroke of X axis, Y axis, strobobe, prism, fog mirror, colorful, focusing motor can be adjusted, and the adjustment range of 0~255,127
means that there is no adjustment.
Speed calibration
| After entering the sub-interface, the speed of X-axis,
Y-axis and 1-4 motor can be adjusted, and the adjustment range of 0~255,127 means no adjustment.
Strength calibration| After entering the sub-interface, the strength of X-axis,
Y-axis and 1-4 motor can be adjusted, and the adjustment range of 0~255,127 means that there is no adjustment.
Fan control
| After entering the sub-interface, the intelligent switch of the fan, half power / color / white light speed, and the
shutdown time of the light head / base can be controlled
Other calibration| Voice-control sensitivity calibration, usage time, and
password modification.
Reset
Press Up and Down to switch the reset mode, and press OK to reset directly.
option | explain |
---|---|
Head motor reset | Effect motor reset except for XY |
XY motor reset | XY axis reduction |
Full motor reset | Lamps reset |
system info
option | explain |
---|---|
Reset information | If the red ERR indicator shines, the lamp is running wrong, |
and details
can be viewed in the subinterface
AndDMX data monitoring| This enters the subinterface to display channel values
for viewing
sensor information| Real-time monitoring of the light coupling, hall and other
sensors on the
lamp state
Hardware version number| Lighting hardware information
Software version number| Lamp software version
View the current status of the lamp
Enter the page shown, you can view the information and real-time status of the
lamp to know the use status of the lamp. If the lamp needs after sale, please
provide the status information displayed on the page as the basis for
judgment, as shown in the following table: status information
Motor information| Display the information status of all motors and
signals in the lamp
---|---
Hoare| Not shown, it means that the motor is not Hall corrected, 0 means that
the motor leaves the correction position point, and 1 means that
the motor is at the correction position point
state| Show the motor reset completion state
X axle| Displays the real-time position value of the
X-axis optical coupling feedback
Y axle| Display the real-time position value of the
Y-axis optical coupling feedback
optocoupler| Show the level state of two signals with X
and Y axis, binary
Fault / status record| Display the last 8 fault records of lamp reset and operation, the fault records are not saved after power failure, when the next power cycle
is valid
fault data| Total number of faults detected after
power-on
12::03| Power time in minutes
Hall fault| The corresponding motor does not detect an
effective Hall signal when the motor is reset
Hall short circuit| The Hall signal of the motor detected at the
corresponding motor reset is always valid
Optical coupling
failure
| No effective photocoupling signal is detected
when the corresponding motor is reset
fall out step| The corresponding motor loses its step during
operation
Crash rod| Cragainst the positioning lever when the
motor is reset
Bulb failure| Light bulb accidentally extinguished
Sensor failure| Temperature sensor signal is abnormal,
Fan fault| The main fan is not working properly
Lighting status| Displays the critical status data for the current lamp
for reference
communication| 0~100%, the communication quality of the
data link within the lamp
miscount| The number of error frames detected after
power, accumulated
Light source
temperature
| Show the temperature of the current light
source, “- – -” indicates no detection
| Display plate temperature| Displays the temperature of the current
display board or the nearby ambient temperature
---|---|---
Sensor 1 temperature| Displays the current motherboard temperature
or the ambient temperature at the motherboard installation location
Version information| Display the information and version of current lamps and make an
important reference for after-sales maintenance
equipment| Name of lamp, same to equipment
information of RDM
model| Model of lamp, same as model information of
RDM
display board| Firmware version and serial number of the
display board
Main board 1| Firmware version and serial number of the
motherboard 1
Light source time| Record the total accumulative time of the light source, as a reference
for regular maintenance of the light source
Lamps time| Record the total cumulative time of lamp opening, unit minutes, do
not clear
Channel description
The lamp channel can be viewed in scene mode. The channel mode is set in the Address Settings page. The detailed data are shown in the following table below:
channel table
channel 16DMX | name | numeric value | description |
---|
CH1
| ****
pigment
| 0-6| white light
7-11| Color 1
12-16| Color 2
17-21| Color 3
22-26| Color 4
27-31| Color 5
32-36| Color 6
37-41| Color 7
42-46| Color 8
47-51| Color 9
52-56| Color 10
57-61| Color 11
62-66| Color 12
67-71| Color 13
72-75| White light + color 1
76-79| Color # 1 + color # 2
80-83| Color # 2 + color # 3
84-87| Color # 3 + color # 4
88-91| Color # 4 + color # 5
92-95| Color # 5 + color # # 6
96-99| Color # 6 + color # 7
100-103| Color # 7 + color # # 8
104-107| Color # 8 + color # # 9
108-111| Colour 9 + color 10
112-115| Colour 10 + color 11
116-119| Colour 11 + color 12
120-123| Colour 12 + color 13
124-127| Color of 13 + white light
128-189
| From fast to slow counterclockwise flow
water
190-193| Stop running water
194-255| From slow to fast, the
clockwise flow of water
CH2| stroboflash| 0-3| The light switch is closed
| | 4-103| Synchronous flash
---|---|---|---
104-107| The light switch is opened
108-207| Equal frequency flash
208-212| The light switch is opened
213-251| Random flash
252-255| The light switch is opened
CH3| aiming| 0-255| With 0-100% dimming
CH4
| ****
pattern
| 0-4| White aperture
5-9| Pattern 1
10-14| Pattern 2
15-19| Pattern 3
20-24| Pattern 4
25-29| Pattern 5
30-34| Pattern 6
35-39| Pattern 7
40-44| Pattern 8
45-49| Pattern 9
50-54| Pattern 10
55-59| Pattern 11
60-64| Pattern 12
65-69| Pattern 13
70-127
| From fast to slow counterclockwise flow
water
128-132| Stop running water
133-190
| From slow to fast counterclockwise flow
water
191-195| Pattern 1 shakes from slow
to fast
196-200| Pattern 2 shakes from slow
to fast
201-205| Pattern 3 shakes from slow
to fast
206-210| Pattern 4 shakes from slow
to fast
211-215| Pattern 5 shakes from slow
to fast
216-220| Pattern 6 shakes from slow
to fast
221-225| Pattern 7 shakes from slow
to fast
226-230| Pattern 8 shakes from slow
to fast
| | 231-235| Pattern 9 shakes from slow
to fast
---|---|---|---
236-240| Pattern 10 shakes from slow
to fast
241-245| Pattern 11 shakes from slow
to fast
246-250| Pattern 12 shakes from slow
to fast
251-255| Pattern 13 with a jitter
ranging from slow to fast
CH5| Prism 1| 0-127| Remove the prism
128-255| Prism cut in
CH6| Prism 2| 0-127| Remove the prism
128-255| Prism cut in
CH7
| ****
Prism rotation
| 0-127| 0-400 degrees
128-189| From fast to slow forward
flowing water
190-193| cease
194-255| From slow to fast, the
reverse flow of water
CH8| colorful| 0-127| not have
128-255| Insert colorful
CH9| atomization| 0-127| not have
128-255| Insert atomization
CH10| focus| 0-255| From far to near
CH11| X axle| 0-255| 0-540 degrees
CH12| X axis
fine- tuning
| 0-255| The X-axis 16bit
fine-tuning channel
CH13| Y axle| 0-255| 0-240 degrees
CH14| Y axis
fine- tuning
| 0-255| Y axis 16bit tuning channel
CH15| XY velocity| 0-255| From fast to slow
CH16
| ****
reset
| 0-99| NF
100-110| Off-bulb (5S)
111-199| NF
200-210| Open the light bulb (5S)
211-219| NF
220-229| XY motor reset (5S)
230-239| Effect motor reset (5S)
240-255| All motor reset (5S)
Common faults and use of attention
Common fault handling
Lamps contain a microcomputer circuit board, high voltage power supply, and
other professional components, for your safety and product life, non-
professionals do not remove lamps and related accessories without
authorization. The bulb is not lit on (except for the LED light source)
Possible reasons : The bulb is not fully cooled, or the bulb reaches its
life, treated as follows:
- Due to abnormal operation, the bulb is not completely cooled, the light body should be cooled for more than 10 minutes, so that it’s internally completely restored to the normal state, and then start the power supply again;
- Check whether the bulb has reached the service life, and replace it with a new bulb;
- Check whether the bulb and the lamp lighting device circuit leakage, fall off, or have poor contact;
- Replace the new lamplighter. Possible reasons: the bulb is used for a long time or the light path is not clean, treated as follows:
- Check whether the bulb has reached the service life, and replace it with a new bulb;
- Check whether the optical components or bulbs are clean and whether there is dust accumulation on the bulbs and other optical components, and the bulbs and the components should be cleaned and maintained regularly.
- The pattern projection is vague
- Check if the electronic focus channel values are appropriate for the current projection distance.
- The light fixtures work intermittently
- Reason: The internal line enters the protection state and handles as follows:
- Check whether the fan is running normally or whether it is dirty, causing the temperature inside the lamp to rise;
- Check whether the internal temperature control switch is in a closed state;
- Check the bulb and replace the new bulb.
- The control of the console is not accepted after a normal reset
- Possible cause: signal line fault or lamp parameter set abnormal, handle as follows:
- Check the starting address code and the connection of the DMX signal line (whether the signal cable is intact and whether the Alcock head connection is loose);
- Add a signal amplifier, add 120 ohm terminal resistance;
- The lamps cannot be started
- Cause: poor power line, treated as follows:
- Check whether the insurance on the power input socket is fused and replace the insurance;
- Light travel due to vibration in long-distance transportation
- Check the input power supply, computer board, and other connecting devices.
Precautions for use
Check whether the local power supply meets the rated voltage requirements
of the product and whether the leakage protector and overcurrent protector
meet the load requirements;
- Do not use the damaged power cords with insulation and do not attach the power cords to other wires;
- The lamps and lanterns use strong air refrigeration, which makes it easy to accumulate dust. They must be cleaned once a month, especially the cooling outlet, otherwise, it will be blocked due to dust, resulting in poor heat dissipation, so that the lamps appear abnormal.
- When installing the lamps, the fixed screws must be tightened, and equipped with safety cables, and regular inspection;
- In the installation and positioning of the lamp, any point on the surface of the lamp and any burning explosive, keep a minimum distance of 10 meters, the distance from the irradiation is 2.5 meters, please do not install the lamp directly on the surface of combustible material;
- It is recommended that the continuous working time of lamps should not exceed 10 hours, and the interval time of continuous starting lamps should not be less than 10 minutes, otherwise, it will not be triggered normally because of the overheating protection of the bulb;
- The closing time of using the on-off valve should not exceed 5 minutes. If the light needs to be closed for a long time, the console (light gun control channel) should be used to turn off the light gun;
- To ensure that multiple lamps better comply with the scene effect, the lamps should not always be in the unfinished current scene, that is, start the next scene action, it is best that this state is not more than 3 minutes, to ensure that multiple lamps can run synchronously;
- In the process of use, if the lamps are abnormal, the lamps should be stopped in time to prevent other faults.
RDM use considerations
RDM is an extended version of DMX512-A protocol, which is the remote device
management (Remote Device Management) protocol. Traditional DMX512 protocol
communication is one-way communication, the protocol is based on the RS-485
bus, RS-485 is a time-sharing multi-point and semi-duplex protocol, and only
one port is allowed for host output at the same time. Therefore, the following
points should be noted when using RDM.
- To use the console or host device that supports the RDM protocol host;
- To use the two-way signal amplifier, the traditional one-way signal amplifier does not apply to the RDM protocol, because the RMD protocol needs feedback data, the use of the one-way amplifier will block the returned data, resulting in the search for lamps;
- All lamps must be set to DMX mode to ensure that there is only one host on the signal line;
- A 120 ohm impedance matching resistance must be inserted between terminals 2 and 3 of the terminal plug. When the signal line is relatively long, the signal reflection, which is conducive to the quality of communication;
- When the lamp is subject to DMX control, but can not RDM search the lamp, first check the signal amplifier, and then check whether the 2 and 3 lines of the signal line have poor contact.
Lighting installation
Lamps can be placed horizontally, obliquely,ly, and upside down. We must
pay attention to the installation method when hanging in oblique and inverted
hanging.
- 2 As shown in Figure 2, before the positioning of the lamp, to ensure the stability of the installation site, in the reverse hanging installation, must ensure that the lamp does not fall off the support frame, need to use a safety rope through the support frame and the lamp handle for auxiliary hanging, to ensure safety. Prevent the lamps from falling and sliding.
- When the lamps are installed and tested, pedestrians are not allowed to pass below. Regularly check whether the safety rope is worn and whether the hook screws are loose.
- Our company shall not bear any responsibility for all the consequences caused by the unstable installation of the hanging and the lamp falling.
ShenZhen BECEN Stage Equipment Co., Ltd
Add : Room 501,5th floor, Yishenrong Industrial Park, Xihuan Road,
ShaJing, BaoAn, Shenzhen, Guangdong, China
Website: www.szbecen.com
MORE INFORMATION
-
Tel: 86-13410588234
-
Email : sales01@szbecen.com
Frequently Asked Questions
- Q: Can this moving headlight be used outdoors?
- A: No, the lamp is only suitable for indoor drying places as mentioned in the safety guidance section. Using it outdoors may lead to damage or safety hazards.
- Q: What should I do if I encounter smoke or odor from the new lamp?
- A: It is normal for a new lamp to emit some smoke or odor initially. This should dissipate after about 15 minutes of operation. If it persists, contact customer support for assistance.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>