KEBENES HAT606 Sound Amplifier or Hearing Aid User Manual

June 3, 2024
KEBENES

KEBENES HAT606 Sound Amplifier or Hearing Aid

KEBENES HAT606 Sound Amplifier or Hearing Aid

IN THE PACKAGE

KEBENES HAT606 Sound Amplifier or Hearing Aid 1

ASSEMBLE THE EARPLUGS
Please choose the appropriate size of the ear tips for you, and assemble the ear tips as below picture.

KEBENES HAT606 Sound Amplifier or Hearing Aid 2

HOW TO WEAR YOUR SOUND AMPLIFIER

  • Hold the sound amplifier with your index finger and thumb, with the little pore facing up.
  • Gently insert the sound amplifier into the ear canal, and then rotate it backwards until the product is stable in the ear and will not fall. Insert the Left and Right sound amplifier into your ear canals as shown.

KEBENES HAT606 Sound Amplifier or Hearing Aid 3

KNOW YOUR SOUND AMPLIFIER

KEBENES HAT606 Sound Amplifier or Hearing Aid 4

PAIRING-FIRST USE

  1. Open the charging box, the headset will automatically enter the Bluetooth pairing mode, and the headset will flash blue light quickly.
  2. Open the phone settings, turn on the Bluetooth, search for CHICANA HAT606, and then click the circle icon to pair and connect.

KEBENES HAT606 Sound Amplifier or Hearing Aid 5

TECHNICAL SPECIFICATION

Model HAT606
Output. OSPL90 Max. ≤105±3dB
FOG50 MAX Gain ≤35±3dB
EQ Input Noise ≤28dB
Frequency Range(Not narrower than) 300Hz-5000Hz
Working Current ≤12mA
Total Harmonic Distortion 5%
Working Volatage D.C 3.7V
Play Time 5hours

Notice: The above parameter index testing is on basis of FONIX8000Hearing Aid Test System;
Inspection standard: IEC 60118-7 2005, 2CC coupling cavity HA-1

HOW TO USE SOUND AMPLIFIER

KEBENES HAT606 Sound Amplifier or Hearing Aid 6

KEBENES HAT606 Sound Amplifier or Hearing Aid 7

Remarks:

  1. Enter the call mode when the music is playing. When the c all is over, the music is played automatically.
  2. The earphone enters the call mode in the Sound amplifier mode. A fter the call, the earphone automatically returns to the Sound amplifier mode.

TROUBLESHOOTING GUIDE

Symptom Possible Causes Solutions

Not Loud Enough

| Blocked tubing/earbud| Clean or replace ear wax guard as needed.
Hearing change| Contact your hearing professional.
Too much dust| Clean both microphone and receiver with brush.

Inconsistent Performance

|

Restart required

| Put the sound amplifier into charging case,close the top cover to turn off. Then take out the sound amplifier, press and hold each side for 2 seconds to restart.
Blocked tubing/ earbud| Clean or replace ear wax guard as needed.

Unclear, Distorted Performance

|

Restart required

| Put the sound amplifier into charging case,close the top cover to turn off. Then take out the sound amplifier, press and hold each side for 2 seconds to restart.
Blocked tubing/ earbud| Clean or replace ear wax guard as needed.
Defective sound amplifier| Contact your hearing professional.

Dead Sound amplifier

| Charge required| Put the sound amplifier into charging case, close the top cover,and wait for charging.
Blocked earbud/tubing| Clean or replace ear wax guard as needed.
Ear canal fulfilled with oil wax| Contact your hearing professional.
No LED indicator when sound amplifier are inserted into the charging port|

Low battery

| Connect the Type-c cable to your charging case and plug it into the wall. The on-board battery LEDs will flash for a few seconds to indicate the connection to the power source.
Orange blinking LED by charging port|

Low battery

|

Insert your type-c cord to charge the case

Sound amplifier whistling in the charging case|

Dead battery

| Put the sound amplifier into charging case, close the top cover, and insert your type-c cord to charge the case.

If the Sound amplifier whistles in the ear

|

Sound amplifier earplug and ear canal sealing or fit is not good

| 1. Gently turn the sound amplifier, so that the sound amplifier earplug and ear canal sealing and fitting better, so that you can deal with the whistle phenomenon.
2. The size of the earplug on the sound amplifier does not match your ear canal.Use earplug of a different size to improve thewhistle phenomenon.

Sound amplifier has no sound

| The button time is too short to start|

Press and hold touch panel for 3 seconds to restart

Low battery| Put the sound amplifier into the charging case to charging
Blocked up the earplugs’ sound port or microphone port|

Clean the sound port or microphone port

The voice is very weak and unclear

| Low battery| Put the sound amplifier into the charging case to charging
The volume is too low| Click to adjust the volume level
Earplugs loose| Re-wearing the sound amplifier
Sound amplifier failure self-checking table

INTENDED USE

  1. Medical purpose
    • The sound amplifier intends to compensate for impaired hearing.
  2. Intended patients and environment
    • The sound amplifier uses for indoor and outdoor environment, and patients under 18 years old must require the doctor’s approval.
  3. Side effects
    • For patients with sensitive skin, the silicone material may irritate your ear canals.
    • First use may cause slight pain to the ear canal due to maladjustment.

TWS PAIRING MODE OR RESET MODE

  1. Put the left earphone and the right earphone into the charging case bin, open the top cover of the charging case, long press the button at the bottom of the charging case for 5 seconds, and the White indicator light on the charging case starts to blink quickly.
  2. The Red/Blue/Green indicator will flash once alternately on the left earphone and the right earphone that enter TWS pairing mode or reset mode; the Blue indicator light of Left earphone will off and the Blue indicator light of right earphone will flash quickly that is ready for Bluetooth pairing mode.
  3. The White indicator light on the charging case flashes quickly about 15 seconds and off;
  4. you can connect your smart phone by “PAIRING-FIRST USE” page;

KEBENES HAT606 Sound Amplifier or Hearing Aid 8

SOUND AMPLIFIER CARE
Keep your sound amplifier clean. Heat, moisture, and foreign substances can result in poor performance.

  • Use a cleaning brush or soft cloth to clean debris from around the user control and microphone; inspect the the receiver, earbud, or ear tip and wax guard regularly.
  • Never use water, solvents, cleaning fluids, or oil to clean your sound amplifier.
  • Charging contacts should always be kept clean and dry.
    Your hearing professional can provide further information on additional maintenance procedures for your sound amplifier, if needed.

MATTERS NEEDING ATTENTION, WARNINGS, AND TIPS

  1. Do not immerse the sound amplifier in any liquid. Remove the sound amplifier before swimming and shampooing. After swimming or washing, wait for the ear canal to dry before wearing the sound amplifier.
  2. Please use the function and volume control switch correctly, open and close as lightly as possible to avoid excessive force.
  3. Applicable objects: Suitable for people with air-conducting hearing loss of about 30-50dB.
  4. Please use sound amplifier with sound amplifier charging cases.
  5. When you do not use sound amplifier, please charge the product regularly to avoid battery damage; the recommended charging time interval of sound amplifier is ≤28 days;

IMPORTANT SAFETY INSTRUCTIONS

CONTRAINDICATION
The device is unsuitable in the following situations:

  • Usage is prohibited for patients with chronic suppurative otitis media and congenital ear atresia.
  • This sound amplifier can only compensate patients with hearing impairment and do not have hearing therapeutic value.
  1. Congenital atresia of external ear or deformity of external auditory meatus, a large number of foreign bodies in external acoustic meatus;
  2. Deafness is unstable, and the degree of hearing loss often fluctuates;
  3. Complaint with headache, dizziness, earache, tinnitus, and other symptoms that are not suitable for adaptation;
  4. Sudden deafness in the past three months; progressive rapid deafness; apparent unilateral deafness or other acute ear diseases;
  5. Effusion in the middle ear and frequent purulence;
  6. Central deafness; non-organic deafness;
  7. Patients with acute otitis externa and tympanitis;
  8. Patients with acute and chronic suppurative otitis media (in the period of purulent infection);
  9. Patients who are allergic to the material of this product.

WARNINGS

  • Keep small swallow-able accessories out of children’s reach.
  • Dropping, immersing in liquid, and accessing strong electromagnetic fields or over heat will damage sound amplifier. If a sound amplifier or accessories remain in the ear, please go to see a doctor as soon as possible, do not take it out by yourself.
  • Warning not to use in explosive or oxygen-enriched atmospheres; it may damage the device.
  • Warning that only the intended person can use it; using a sound amplifier designed for someone else may result in hearing damage.
  • Statement about the special needs of particular patient groups.
  • Warning about common conditions that could damage the device.
  • Warning that results from the risk management file permissible environmental conditions of transport and storage.
  • Each warning/safety contains: nature of Hazard; likely consequences; precautions

NOTICE

  • Please Do not use it at high volume for a long time. Otherwise, it will injure your ear. If you feel uncomfortable, please stop using it.
  • Please check the product every time before using it, and avoid wearing the earplug with foreign objects in ear canal. It will affect the sound amplifier.
  • Avoid shocking and dropping the product. Do not keep or use it in high humidity environments (such as the sauna room).
  • Do not throw the scrapped battery as standard rubbish.
  • Do not use the product in a potential explosive or dangerous environment.
  • Do not share your sound amplifier with others. Your sound amplifier setting is personal and individual, share with someone else will result in others’ hearing damage.
  • Be careful with any unusual skin reactions. In some instances, wearing sound amplifier can cause an allergic reaction leading to it chiness or rashes. If you notice any uncommon skin condition, stop wearing the sound amplifier, and check with a medical specialist.
  • Do not place the sound amplifier near the magnetic objects.
  • Be sure to take off the sound amplifier when getting a diagnosis or treatment.
  • Never pry the inside of the sound amplifier with a needle or similar object; otherwise, it will damage the device.
  • Do not put the sound amplifier near heating appliances or in direct sunlight, and you should also avoid high moisture areas such as bathrooms or near a humidifier.
  • In a closed car in summer, the temperature can rise to very high levels. Do not leave your sound amplifier in a high-temperature car.
  • Do not use the sound amplifier close to a cell phone, otherwise it may increase the noise and affect the sound quality.
  • Please contact the MANUFACTURER:
  • Any questions in setting up, using, or maintaining the sound amplifier;
  • To report unexpected operations or events.

SERVICE AND REPAIR

  1. If for any reason, your sound amplifier and charger do not operate properly, do NOT attempt to fix it yourself.
    Not only are you likely to violate any applicable warranties or insurance, you may also cause further damage.

  2. If your sound amplifier and charger fail or perform poorly, check the guide on the next page for possible solutions. If problems continue, contact your hearing professional for advice and assistance. Most of the problems can find in your hearing professional’s office or clinic.

MAINTENANCE, STORAGE AND DISPOSAL

  1. We do not authorize any institution or individual to maintain and repair the product. If you suspect that the products have any issues, please contact the manufacturer or distributor to handle them.
  2. The user must not attempt any repairs to the device or any of its accessories. Please contact the retailer for repair.
  3. Opening of the equipment by unauthorized agencies is not allowed and will terminate any warranty claim. warning: No modification of this equipment is permitted!

Storage

  1. If you Do not use it, and then put the sound amplifier into the charging case.
  2. Do not put the device under the sunshine, high temperature, and moist environment or someplace, which maybe get in touch with fire or is vulnerable to vibration.
  3. Keep the device storage in following environmental ranges:-20~55℃, ≤95%RH, 700-1060hPa

Disposal
Please dispose of the device under the directive 2002/96/EC – WEEE (Waste Electrical and Electronic Equipment).and Don’t dispose with domestic waste. If you have any queries, please refer to the local authorities responsible for waste disposal.

MAINTENANCE AND CLEAN

  1. Daily maintenance
    It is important to keep your instrument clean and dry. Daily, cleanthe hearing instruments using a soft cloth or tissue. To avoid damage due to humidity or excessive perspiration, please use a drying kit.

  2. Care and maintenance
    Please put it in where children could not reach, dry and no exposed in the sun.
    Do not place sound amplifier near high-temperature heating areas such as stoves.
    Do not leave the sound amplifier in a humid place for a long time.
    Do not scratch the microphone with sharp objects to avoid damage to the microphone.
    Do not disassemble or attempt any repairs by yourself.

  3. Cleaning

  4. Cleaning the earplug
    Remove ear wax plugged in the earpiece by using a stick and brush.

  5. Cleaning hook
    Using a soft cloth or tissue, wipe off any moisture, sweat, or debris from the surface of the device.
    Note: Do not use alcohol or other cleaning solvents to clean the hook as this could damage the protective covering.

HELPFUL HINTS

  • Do not take apart your sound amplifier or insert the cleaning tools inside them. (When not in use, place your sound amplifier in the charger and store them.)
  • In a dry, safe place.
  • Away from direct sunlight or heat to avoid extreme temperatures.
  • Where you can easily find them.
  • Safely out of reach from children and pets. Synergy Charger Care
  • Keep your charger clean. Heat, moisture, and foreign materials can result in poor performance.
  • Do not use water, solvents, or cleaning fluids to clean the charging ports.
  • Keep lid closed as much as possible to avoid dust and debris build-up.
  • Store your charger in a clean and dry location.
  • Fully charge sound amplifier batteries every night.

IMPORTANT NOTICE FOR PROSPECTIVE SOUND AMPLIFIER USERS
Good health practice requires that a person with a hearing loss have a medical evaluation by a licensed physician (preferably a physician who specializes in diseases of the ear) before purchasing a sound amplifier. Licensed physicians who specialize in diseases of the ear are often referred to as otolaryngologists, otologists or otorhinolaryngologists.

The purpose of the medical evaluation is to assure that all medically treatable conditions that may affect hearing are identified and treated before the sound amplifier is purchased.

Warning to Sound amplifier Dispensers
A Sound amplifier dispenser should advise a prospective sound amplifier user to consult promptly with a licensed physician (preferably an ear specialist) before dispensing a sound amplifier if the sound amplifier dispenser determines through inquiry, actual observation, or review of any other available information concerning the prospective user, that the prospective user has any of the following conditions:

  1. Visible congenital or traumatic deformity of the ear.
  2. History of active drainage from the ear within the previous 90 days.
  3. History of sudden or rapidly progressive hearing loss within the previous 90 days.
  4. Acute or chronic dizziness.
  5. Unilateral hearing loss of sudden or recent onset within the previous 90 days.
  6. Audiometric air-bone gap equal to or greater than 15 decibels at 500 hertz (Hz), 1,000 Hz, and 2,000 Hz.
  7. Visible evidence of significant cerumen accumulation or a foreign body in the ear canal.
  8. Pain or discomfort in the ear.

Special care should be exercised in selecting and fitting a sound amplifier whose maximum sound pressure level exceeds 132 decibels because there may be risk of impairing the remaining hearing of the sound amplifier user. (This provision is required only for those sound amplifier with a maximum sound pressure capability greater than 132 decibels (dB).)

FCC WARNING

RF exposure statement
This equipment complies with the FCC radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

FCC Warning
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

NOTE 1: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

NOTE 2: Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

WARM TIPS:
Due to the different actual situations, each customer’s experience of using product is different. If you
have any questions in the using process, please contact our professional customer service staff by our aftersales email (aftersalesmailbox@163.com) or by the platform where you purchased this product as soon as possible. Please believe that our customer service staff will offer you satisfactory assistance.

NORMALIZED SYMBOLS

KEBENES HAT606 Sound Amplifier or Hearing Aid 10

MANUFACTURE: JIANGXI YIANG MEDICAL TECHNOLOGY CO., LTD
Address:Floor 3, Building 3, Ganzhou National High-level Talents Science And Technology Innovation Park,No.1 Wudang M Ganzhou,Jiangxi,341000,CHINA

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals