ITON Technology TZ8258-27A1 ZigBee Module Owner’s Manual Product Information
- June 1, 2024
- Iton Technology
Table of Contents
- TZ8258-27A1 ZigBee Module
- Product Information
- Specifications
- Product Usage Instructions
- Device Overview
- Functional Block Diagram
- Technical Specifications
- Application and Module Mechanical
- Application Notice
- Packaging
- Ordering Information
- Q: What are the general features of the TZ8258-27A1
- Q: How to integrate the module into an existing system?
TZ8258-27A1 ZigBee Module
Product Information
Specifications
Model: TZ8258-27A1
Version: V0.1-Jan., 2024
Module Type: ZigBee
Product Usage Instructions
Device Overview
The TZ8258-27A1 is a ZigBee Module designed for various
applications. It offers a range of features suitable for different
use cases.
Functional Block Diagram
The module block diagram provides an overview of the internal
components and their interconnections, aiding in understanding the
module’s functionality.
Technical Specifications
The technical specifications include RF parameters, module pin
functions, electrical specifications, and working environment
details to ensure proper usage and compatibility.
Application and Module Mechanical
Details about application diagrams, module size, and recommended
land patterns help in the proper integration of the module into
various systems.
Application Notice
Guidelines on SMT temperature settings are provided to ensure
correct assembly and operation of the module.
Packaging
Information on packaging ensures safe transportation and storage
of the module.
Ordering Information
Details on how to order the TZ8258-27A1 module are included for
easy procurement.
FAQ
Q: What are the general features of the TZ8258-27A1
module?
A: The general features include [list features here].
Q: How to integrate the module into an existing system?
A: To integrate the module, follow the application diagram and
ensure the correct module size and land pattern are used.
www.sziton.com
TZ8258-27A1
V0.1-Jan., 2024
TZ8258-27A1
ZigBee Module Datasheet
(Draft Version)
DISCLAIMER AND COPYRIGHT NOTICE Information in this document, including URL references, is subject to change without notice. This document is provided “As if” with no whatsoever, including any warranty of merchantability, noninfringement, fitness for any purpose, or any warranty otherwise arising out of any proposal, specification or samples. All liability, including liability for infringement of any proprietary rights, relating to use of information in this document is disclaimed. No licenses express or implied, by estoppel or otherwise, to any intellectual property rights are granted herein. The Bluetooth logo and symbol belong to the Bluetooth SIG Inc. The Wi-Fi Alliance Member Logo is a trademark of the Wi-Fi Alliance. All trade names, trademarks and registered trademarks mentioned in this document are property of their respective owners, and are hereby acknowledged. Copyright ITON Technology Corp. All rights reserved.
www.sziton.com
TZ8258-27A1
V0.1-Jan., 2024
Table of Contents
1. Device Overview ………………………………………………………………………………………………………………………………………… 3
1.1 Description …………………………………………………………………………………………………………………………………. 3 1.2
Applications ……………………………………………………………………………………………………………………………….. 3 1.3 General
Features ………………………………………………………………………………………………………………………… 3
2. Functional Block Diagram ………………………………………………………………………………………………………………………….4
2.1 Module Block Diagram ……………………………………………………………………………………………………………… 4
3. Technical Specifications
……………………………………………………………………………………………………………………………..4
3.1 RF Parameters ……………………………………………………………………………………………………………………………..4 3.2
Module Pin Functions …………………………………………………………………………………………………………………5
3.3 Electrical Specifications ………………………………………………………………………………………………………………………6
3.4 Working Environment ……………………………………………………………………………………………………………………….. 7
4. Application and Module Mechanical
……………………………………………………………………………………………………….. 7
4.1 Application Diagram …………………………………………………………………………………………………………………..7 4.2
Module Size …………………………………………………………………………………………………………………………………8 4.3 Recommended
Land Pattern ……………………………………………………………………………………………………..8
5. Application Notice …………………………………………………………………………………………………………………………………….. 9
5.1 SMT Temperature Setting Recommendation …………………………………………………………………………..9
6. Packaging ………………………………………………………………………………………………………………………………………………….10
7. Ordering Information ……………………………………………………………………………………………………………………………… 10
8. Revision History ………………………………………………………………………………………………………………………………………. 10
ITON Technology Corp.
Page 2 of 16
www.sziton.com
TZ8258-27A1
V0.1-Jan., 2024
1. Device Overview
1.1 Description
The TZ8258-27A1 module is a ZigBee module developed based on Telink TLSR8258
chip. Supports IEEE 802.15.4 standard and Zigbee-compliant platform. The
solution can be used for a wide range of applications and is perfect for
creating interoperable solution for use within the home combined with leading
Zigbee software stack.The module is equipped with 1MB Flash and 64kB SRAM,
which also has hardware OTA upgrades support and multiple boot switching,
allowing convenient product feature roll outs and upgrades.The TZ8258-27A1
also includes multi-stage power management design allowing ultra-low power
operation and making it the ideal candidate for power-constraint applications.
The module greatly helps on the design and use of customers, and saves time
and development cost for the product to the market.
1.2 Applications
Applications of TZ8258-27A1 module include but not limited to: – Smart
Lighting, Smart Home devices – Building Automation – Smart Grid – Intelligent
Logistics/Transportation/City – Consumer Electronics – Industrial Control –
Health Care
1.3 General Features
· Module Size: 17.0±0.2mm14.0±0.2mm4.4±0.2mm(TZ8258-27A1) · Complies with
2.4GHz IEEE 802.15.4 protocol · Working frequency band: 24002483.5MHz ·
Modulation mode: O-QPSK, GFSK · Transmission rate: 250Kbps@Zigbee, 2Mbps,
1Mbps@BLE · 32-bit RISC-V micro-controller · Program memory: built-in 512kB
Flash · Data memory: 64kB SRAM · Cycle endurance: 100,000 program/erases ·
Rich IO interfaces, including PWM interface, I2C interface, Uart interface,
etc. · Receiving sensitivity: -96dBm@ IEEE802.15.4 250 kbps · Transmit power:
12dBm · Deep sleep with SRAM retention (with 32kB SRAM retention): 3.0µA ·
Working voltage: 1.8V3.6V · Working temperature: -4085 · Metal antenna
ITON Technology Corp.
Page 3 of 16
www.sziton.com
2. Functional Block Diagram 2.1 Module Block Diagram
TZ8258-27A1
V0.1-Jan., 2024
Figure 1. TZ8258-27A1 module Block Diagram TZ8258-27A1 is a wireless module based on the IEEE802.15.4 2.4GHz protocol, built-in 2.4G antenna for wireless communication.
3. Technical Specifications
3.1 RF Parameters
Category Standard Modulation mode Number of channels Channel bandwidth
Transmission rate
ITON Technology Corp.
2.4G IEEE 802.15.4 O-QPSK,GFSK 16 5M 250Kbps
Descriptions
Page 4 of 16
www.sziton.com
TZ8258-27A1
V0.1-Jan., 2024
Parameter
Min.
Typ.
Max.
Unit
Operating frequency
2400
—
2483.5
MHz
Transmit power
10
12
14
dBm
Receiving sensitivity@802.15.4
—
-96
—
dBm
Receiving sensitivity@ 1 Mbps
—
-95
—
dBm
Receiving sensitivity@ 2 Mbps
—
-92
—
dBm
Frequency deviation
-25
—
+25
KHz
Figure 2. TZ8258-27A1 module RF parameters
3.2 Module Pin Functions
TZ8258-27A1 has 27 pins in total, and the pin definitions are shown in Figure
3 and Figure 4 below. Note: Each type of product has definitions of the
general IO port, and cannot be changed at will.
1 GND
27 GND
2 PA1
26 RF2G4
3 PC1
25 GND
4
24
PC0 5
TZ8258-27A1 RESET 23
PB2
PD2
6 PB3
22 PD7
7 PB4
21 PB7
8 PA5
20 PB6
9 PA6
19 PB5
10 GND
18 GND
17*14
11 PA7
12 PA2
13 PA0
14 PA4
15 PA3
16 VDD3
17 VDD3
Figure 3. TZ8258-27A1 module PIN No.
Pin 1 GND 2 PA1 3 PC1 4 PC0
PB2 5
Name
ITON Technology Corp.
Description Ground DMIC clock / UART 7816 clock / I2S clock / GPIO PA[1] General Purpose I/O.Can be used to I2C_SCL. General Purpose I/O.Can be used to I2C_SDA. PWM5 output / UART_CTS / Control external LNA / Low power comparator input / SAR ADC input / GPIO PB[2] Page 5 of 16
www.sziton.com
TZ8258-27A1
V0.1-Jan., 2024
PB3 6
PB4 7
8 PA5 9 PA6 10 GND 11 PA7 12 PA2 13 PA0 14 PA4 15 PA3 16 VDD3 17 VDD3 18 GND
PB5 19
PB6 20
PB7 21
PD7 22
PD2 23
24 RESET 25 GND 26 RF2G4 27 GND
PWM0 inverting output / UART_RTS / Control external PA / Low power comparator input / SAR ADC input / GPIO PB[3] SDM positive output 0 / PWM4 output / Low power comparator input / SAR ADC input / GPIO PB[4] General Purpose I/O.Can be used to USB_DM. General Purpose I/O.Can be used to USB_DP. Ground Can be used to SWS. UART0_TX Pin.Connected to UART_RX of Host. UART0_RX Pin.Connected to UART_TX of Host. UART0_RTS Pin.Connected to UART_CTS of Host. UART0_CTS Pin.Connected to UART_RTS of Host. 3.3V power supply(Typical) 3.3V power supply(Typical) Ground SDM negative output 0 / PWM5 output / Low power comparator input / SAR ADC input / GPIO PB[5] SDM positive output 1 / SPI data input (I2C_SDA) / UART_RTS / Low power comparator input / SAR ADC input / GPIO PB[6] SDM negative output 1 / SPI data output / UART_RX / Low power comparator input / SAR ADC input / GPIO PB[7] SPI clock (I2C_SCK) / I2S bit clock / UART 7816 TRX (UART_TX) / GPIO PD[7] SPI chip select (Active low) / I2S left right channel select / PWM3 output / GPIO PD[2] Power on reset, active low Ground 2.4 GHz RF Port.Keep floating. Ground
Figure 4. TZ8258-27A1 module Pin definition
3.3 Electrical Specifications
Parameter
Min.
Working Voltage
1.8
Sleep Current
—
Standby Current
—
ITON Technology Corp.
Typ.
Max.
Unit
3.3
3.6
V
3
—
uA
TBD
—
mA
Remarks
deep sleep mode vary with power
Page 6 of 16
www.sziton.com
TZ8258-27A1
V0.1-Jan., 2024
RX Current TX Current
—
TBD
—
mA
—
TBD
—
mA
vary with power vary with power
Figure 5. TZ8258-27A1 module electrical specifications
3.4 Working Environment
Parameter
Min.
Typ.
Max.
Unit
Working Temperature
-40
25
85
Storage Temperature
-40
—
125
Working Humidity
—
—
—
%
Storage Humidity
—
—
—
%
Remarks
Figure 6. TZ8258-27A1 module working environment
4. Application and Module Mechanical 4.1 Application Diagram
BOOT
VDD33
BOOT High,PE0 Pin low, Zigbee in Bootloader State
R225 10K
1
TL_PA1
2
TL_PC1
3
IRLML2402
TL_PC0
4
TL_PB2
5
10K
TL_PB3
6
TL_PB4
7
TL_PA5
8
TL_PA6
9
10
GND PA1 PC1 PC0 PB2 PB3 PB4 PA5 PA6 GND
27 GND
26 RF2G4
25 GND
24 RESET
TZ8258-27A1 PD2 23
22 PD7
21 PB7
20 PB6
19 PB5
18 GND
17 VDD3
16 VDD3
12 PA2
11 PA7
17*14
VDD33
VDD33
RESET TL_PD2 TL_PD7 TL_PB7 TL_PB6 TL_PB5
10K
Reset High,RESET Pin low, Zigbee in Reset State
IRLML2402
Reset
10K
0.1uF
4.7uF
TL_PA3_UART_CTS 15 PA3
TL_PA4_UART_RTS 14 PA4
TL_PA0_UART_RX 13 PA0
TL_PA2_UART_TX
TL_PA7_SWS
Figure 7. Application Circuit Diagram of TZ8258-27A1
ITON Technology Corp.
Page 7 of 16
www.sziton.com
4.2 Module Size
TZ8258-27A1
V0.1-Jan., 2024
Figure 8. TZ8258-27A1 Module Size
4.3 Recommended Land Pattern
Figure 9. TZ8258-27A1 Module Recommended land Pattern
ITON Technology Corp.
Page 8 of 16
www.sziton.com
5. Application Notice
5.1 SMT Temperature Setting Recommendation
Referred to JEDEC/IPC J-STD-020 standard. Peak temperature:<260 Number of
times: 2
TZ8258-27A1
V0.1-Jan., 2024
Figure 10. TZ8258-27A1 module SMT temperature settings recommendation
ITON Technology Corp.
Page 9 of 16
www.sziton.com
6. Packaging
TZ8258-27A1
V0.1-Jan., 2024
The TZ8258-27A1 module is shipped in tape and reel, and the minimum package is 600 PCS.
Figure 11. TZ8258-27A1 module packaging
7. Ordering Information
Part NO. TZ8258-27A1
Working Voltage 3.3V
ANT Metal antenna
Size 17.0mm14.0mm4.4mm
Mark
8. Revision History
Version V0.1 Draft Version
Change Content
Date 2024.1.30
Reviser Phil
ITON Technology Corp.
Page 10 of 16
www.sziton.com
TZ8258-27A1
V0.1-Jan., 2024
FCC Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This
equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined
by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following
measures:
— Reorient or relocate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
— Consult the dealer or an experienced radio/TV technician for help.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
This device may not cause harmful interference, and (2) this device must accept any interference received, including interference
that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate
the equipment
*RF warning for Mobile device:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be
installed and operated with minimum distance 20cm between the radiator & your body.
The OEM must certify the final end product to comply with unintentional radiators (FCC Sections 15.107 and 15.109) before
declaring compliance of the final product to Part 15 of the FCC rules and regulations. Integration into devices that are directly or
indirectly connected to AC lines must add with Class II Permissive Change.
The OEM must comply with the FCC labeling requirements. If the module’s label is not visible when installed, then an
additional permanent label must be applied on the outside of the finished product which states: “Contains transmitter
module FCC ID: 2BF4V-TZ8258-27A1”.
Additionally, the following statement should be included on the label and in the final product’s user manual:
“This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interferences, and
(2) this device must accept any interference received, including interference that may cause undesired operation.” The module is
limited to installation in applications. Separate approval is required for all other operating configurations, including portable
configuration with respect to Part 2.1093 and different antenna configurations. A module or modules can only be used without
additional authorizations if they have been tested and granted under the same intended end – use operational conditions, including
simultaneous transmission operations. When they have not been tested and granted in this manner, additional testing and/or FCC
ITON Technology Corp.
Page 4 of 11
www.sziton.com
TZ8258-27A1
V0.1-Jan., 2024
application filing may be required. The most straightforward approach to address additional testing conditions is to have the grantee responsible for the certification of at least one of the modules submit a permissive change application. When having a module grantee file a permissive change is not practical or feasible, the following guidance provides some additional options for host manufacturers. Integrations using modules where additional testing and/or FCC application filing(s) may be required are: (A) a module used in devices requiring additional RF exposure compliance information (e.g., MPE evaluation or SAR testing); (B) limited and/or split modules not meeting all of the module requirements; and (C) simultaneous transmissions for independent collocated transmitters not previously granted together.This Module is full modular approval, it is limited to OEM installation ONLY. Integration into devices that are directly or indirectly connected to AC lines must add with Class II Permissive Change. (OEM) Integrator has to assure compliance of the entire end product include the integrated Module. Additional measurements (15B) and/or equipment authorizations (e.g. Verification) may need to be addressed depending on co-location or simultaneous transmission issues if applicable. (OEM) Integrator is reminded to assure that these installation instructions will not be made available to the end user. Integration instructions for host product manufacturers according to KDB 996369 D03 OEM Manual v01
2.2 List of applicable FCC rules FCC Part 15 Subpart C 15.247 & 15.207 & 15.209 & 15.205
2.3 Specific operational use conditions When installed in smart terminal products, the host manufacturer must negotiate with the module manufacturer on the final installation method in the system.The module can be used for mobile applications with a maximum 2.26 dBi antenna. The host manufacturer installing this module into their product must ensure that the final compost product complies with the FCC requirements by a technical assessment or evaluation to the FCC rules, including the transmitter operation. The host manufacturer has to be aware not to provide information to the end user regarding how to install or remove this RF module in the user’s manual of the end product which integrates this module. The end user manual shall include all required regulatory information/warning as show in this manual.
The module should be installed and operated with minimum distance 20cm between the radiator & your body. and if RF exposure statement or module layout is changed, then the host product manufacturer required to take responsibility of the module through a change in FCC ID or new application. The FCC ID of the module cannot be used on the final product. In these circumstances, the host manufacturer will be responsible for re-evaluating the end product (including the transmitter) and obtaining a separate FCC authorization.When the host is a portable device, it is necessary to take a SAR test with your set mounting this module. Class II permissive change application is necessary using the SAR report. Please contact kevin (kevin@sziton.com). And an application for a Class II permissive change from a Mobile equipment to a Portable equipment is also required.
ITON Technology Corp.
Page 12 of 16
www.sziton.com
TZ8258-27A1
V0.1-Jan., 2024
Note) Portable equipment : Equipment for which the spaces between human body and antenna are used within 20cm. Mobile equipment : Equipment used at position in which the spaces between human body and antenna exceeded 20cm.
1. According to the following requirements of the power supply DC3.3V, power up, about 3 seconds to to complete the initial. 2. open application software (need to install the company’s specific application software development, application software interface can be customized according to customer’s product requirements).
2.4 Limited module procedures The module is a Single module.
Requirement per 15.212 and KDB 996369 D01
The radio elements must have the radio frequency circuitry shielded. Physical
components and tuning capacitor(s) may be located external to the shield, but
must be on the module assembly. The module must have buffered modulation/data
inputs to ensure that the device will comply with Part 15 requirements with
any type of input signal.
The module must contain power supply regulation on the module.
The module must contain a permanently attached antenna, or contain a unique
antenna connector, and be marketed and operated only with specific antenna(s),
per §§ 15.203, 15.204(b), 15.204(c), 15.212(a), 2.929(b).
The module must demonstrate compliance in a stand-alone configuration.
ITON Technology Corp.
Explanation from Grantee (do not write yes/no, but explain why product
complies/how it is achieved) Has RF shielding.
The modular have buffered modulation/data inputs.
The modular transmitter have its own power supply regulation.(DC 3.3V) Antenna
restrictions are added in the manual.The antenna needs to be professionally
installed.
The module was tested in a stand-alone configuration, please refer to the
Setup
Page 13 of 16
www.sziton.com
TZ8258-27A1
V0.1-Jan., 2024
Photo for the detail
The module must be labeled with its permanently affixed FCC ID label, or use
an electronic display (see KDB Publication 784748).
The module must comply with all specific rules applicable to the transmitter,
including all the conditions provided in the integration instructions by the
grantee.
The module must comply with RF exposure requirements
Please refer to label sample exhibit – host labeling is described in integration manual The required FCC rule has been fulfilled and all the instructions for the maintaining compliance have been clearly stated in the User Manual. The MPE evaluation with 20cm distance restriction is submitted for the compliance of RF Exposure requirement.
2.5 RF exposure considerations
The module complies with FCC radiation exposure limits set forth for an uncontrolled
environment.The module should be installed and operated with minimum distance 20cm
between the radiator & your body.
2.6 Antennas
This module has been approved to operate with the antenna types listed below, with the
maximum permissible gain indicated.The module antenna requires professional installation,
and the antenna type cannot be changed. The gain cannot exceed 2.26dBi.
Frequency band
Antenna Type
Model Number
Max Gain
2405-2480MHz
Shrapnel Antenna
TZ8258-27A1
2.26(dBi)
ITON Technology Corp.
Page 14 of 16
www.sziton.com
TZ8258-27A1
V0.1-Jan., 2024
This device is intended only for host manufacturers under the following conditions: The transmitter module may not be co-located with any other transmitter or antenna; The module shall be only used with the External antenna(s) that has been originally tested and certified with this module. The antenna must be either permanently attached or employ a `unique’antenna coupler.
As long as the conditions above are met, further transmitter test will not be
required. However, the host manufacturer is still responsible for testing
their end-product for any additional compliance requirements required with
this module installed (for example, digital device emissions, PC
peripheralrequirements, etc.). 2.7 Label and compliance information Host
product manufacturers need to provide a physical or e-label stating
“Contains FCC ID: 2BF4V-TZ8258-27A1 With their finished product.
2.8 Information on test modes and additional testing requirements The module
complies with FCC radiation exposure limits set forth for an uncontrolled
environment.The module should be installed and operated with minimum distance
20cm between the radiator & your body. and if RF exposure statement or module
layout is changed, then the host product manufacturer required to take
responsibility of the module through a change in FCC ID or new application.
The FCC ID of the module cannot be used on the final product. In these
circumstances, the host manufacturer will be responsible for re-evaluating the
end product (including the transmitter) and obtaining a separate FCC
authorization.When the host is a portable device, it is necessary to take a
SAR test with your set mounting this module. Class II permissive change
application is necessary using the SAR report. Please contact kevin
(kevin@sziton.com). And an application for a Class II permissive change from a
Mobile equipment to a Portable equipment is also required.
Note) Portable equipment : Equipment for which the spaces between human body
and antenna are used within 20cm. Mobile equipment : Equipment used at
position in which the
ITON Technology Corp.
Page 15 of 16
www.sziton.com
TZ8258-27A1
V0.1-Jan., 2024
spaces between human body and antenna exceeded 20cm. Host manufacturer must perform test of radiated & conducted emission and spurious emission, etcaccording to the actual test modes for a stand-alone modular transmitter in a host, as well as for multiple simultaneously transmitting modules or other transmitters in a host product. Only when all the test results of test modes comply with FCC requirements, then the end product canbe sold legally. 2.9 Additional testing, Part 15 Subpart B disclaimer The modular transmitter is only FCC authorized for FCC Part 15 Subpart C 15.247 & 15.207 & 15.209 & 15.205and that the host product manufacturer is responsible for compliance to any other FCC rules that apply to the host not covered by the modular transmitter grant of certification. If the grantee markets their product as being Part 15 Subpart B compliant (when it also contains unintentional- radiator digital circuity), then the grantee shall provide a notice stating that the final host product still requires Part 15 Subpart B compliance testing with the modular transmitter installed. 2.11 The user manual of the end product should include: a) Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. b) The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. c) This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. d) This device is restricted to indoor use. e) The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter.
ITON Technology Corp.
Page 16 of 16