Lenovo IBM Flash Adapters Enterprise Value for System x Owner’s Manual
- June 3, 2024
- Lenovo
Table of Contents
Lenovo IBM Flash Adapters Enterprise Value for System x
IBM Flash Adapters Enterprise Value for System x
Product Guide (withdrawn product)
The IBM® Flash Adapters F825, F1650, and F3200 Enterprise Value for System x®
are designed for the application of solid-state storage to webscale and cloud
data centers. Delivering high speed, low latency, and high efficiency, this
new line of flash adapters brings scalable and optimized performance to
distributed scale-out architectures at low cost. These adapters are designed
primarily for cost-efficient high volume servers and computing appliances to
maximize compute efficiency while providing the added benefits of lower power
and cooling costs, low management impact, and smaller storage footprints.
Figure 1. IBM Flash Adapters Enterprise Value for System x
Did you know?
The IBM Flash Adapters Enterprise Value use flash memory as their storage
medium, contain no moving parts, and do not have the issues associated with
vibration, noise, and mechanical failure. The adapters are built as block
devices on a PCIe bus with advanced wear-leveling, advanced ECC, and chip-
level redundancy, providing exceptional reliability and efficiency.
These adapters can provide lower operational expenditure (OPEX) and capital
expenditure (CAPEX) in applications that require high storage I/O performance
compared to solutions that use a larger number of hard disk drives and solid-
state drives to achieve equivalent performance.
Rigorous testing of the IBM Flash Adapters Enterprise Value by IBM through the
IBM ServerProven® program ensures a high degree of confidence in storage
subsystem compatibility and reliability. Providing an additional peace of
mind, the adapters are covered under IBM warranty.
Part number information
Table 1 lists the information for ordering part numbers and feature codes.
Table 1. Ordering part numbers and feature codes
The part numbers for the adapters include the following items:
- IBM Flash Adapter Enterprise Value with 3U bracket attached 2U bracket (F825 and F1650 adapter only)
- USB Key with documentation
- Quick Install Guide
- Important Notices document
- Warranty Flyer
Features
Based on the standard PCIe architecture coupled with silicon-based NAND
clustering storage technology, the Flash Adapters Enterprise Value are
optimized for System x rack servers. These scalable designs include cost-
effective Multi-Level Cell (MLC) technology in standard PCIe form factors.
These adapters use NAND flash memory as the basic building block of solid-
state storage and contain no moving parts, so they are less sensitive to
issues associated with vibration, noise, and mechanical failure. These
adapters are built as block devices on a PCIe bus with advanced wear-leveling,
ECC, and chip-level redundancy providing unparalleled reliability and
efficiency.
The IBM Flash Adapters Enterprise Value for System x can deliver fast and
scalable performance at low latency required for webscale and cloud
environments. The following typical applications require ultra-high I/O
performance:
- Large scale transaction processing Cloud computing
- Content distribution
- On-demand streaming
- Data warehousing
- Business intelligence and analytics Decision support
The IBM Flash Adapters Enterprise Value have many features.
Technology features
- Up to 3.2 TB of solid-state storage in an industry-standard PCIe form factor.
- High-density design with cost-effective MLC NAND technology reduces storage footprint. Functions as a PCIe storage and controller device.
- The operating system sees a block device.
Performance features
- High-speed, low latency, consistent, and scalable I/O performance
- Access latency can be as low as 19 ?s
- Up to 1.5 GBps of sustained sequential throughput
- Up to 144,000 random read IOPS and up to 535,000 random write IOPS using 512 bytes data blocks
- Integrates with host processor as a memory tier for direct parallel access to flash
Reliability features
- Advanced wear leveling
- ECC protection
- Adaptive Flashback redundancy for RAID-like chip protection with self-healing capabilities
- Monitoring and management features
- Power consumption
- Thermal information
- Flash wear-out
Note: These adapters cannot be used as bootable devices.
Technical specifications
Table 2 presents the technical specifications for the IBM Flash Adapters
Enterprise Value.
Table 2. IBM High IOPS MLC Adapter technical specifications
The TBW (total bytes written) value assigned to a solid-state device is the
total bytes of written data (based on the number of P/E cycles) that a device
can be guaranteed to complete (the percentage of remaining P/E cycles is equal
to the percentage of remaining TBW). The IBM warranty for the solid-state
storage is limited to devices that have not reached the maximum guaranteed
number of program/erase cycles. Solid-state storage that reaches this limit
might fail to operate according to its specifications. Because of such
behavior by solid-state devices, careful planning must be done to use solid-
state storage in the application environments to ensure that the TBW of the
device is not exceeded before the end of the required life expectancy.
Writes are tracked and reported by the adapter’s management utility and might
be affected by application writes, data patterns, and maintenance designed to
maximize data integrity.
Specification | 825 GB | 1650 GB | 3200 GB |
---|---|---|---|
Part number | 00AE861 | 00AE864 | 00AE867 |
Interface | PCIe 2.0 x4 | PCIe 2.0 x4 | PCIe 2.0 x8 (x4-wired) |
Form factor | Half height, half length | Half height, half length | Full height, |
half length
Capacity| 825 GB| 1650 GB| 3200 GB
Endurance| 4 PB TBW| 8 PB TBW| 20 PB TBW
Random read IOPS (512 bytes blocks)| 135,000| 144,000| 115,000
Random write IOPS (512 bytes blocks)| 535,000| 535,000| 535,000
Random read IOPS (4 KB blocks)| 130,000| 130,000| 115,000
Random write IOPS (4 KB blocks)| 235,000| 235,000| 243,000
Sequential read rate (1 MB blocks)| 1.4 GBps| 1.4 GBps| 1.5 GBps
Sequential write rate (1 MB blocks)| 1.1 GBps| 1.1 GBps| 1.3 GBps
Read access latency| 77 ?s| 77 ?s| 92 ?s
Write access latency| 19 ?s| 19 ?s| 19 ?s
Power requirements| 25 W max| 25 W max| 25 W max
Supported servers
Table 3 lists the compatibility information for the IBM Flash Adapters
Enterprise Value and System x and IBM iDataPlex® servers.
Table 3. System x, iDataPlex, and NeXtScale compatibility (Part 1)
Part number| Description|
| | | | | |
|
|
|
| |
---|---|---|---|---|---|---|---|---|---|---|---|---|---
00AE861| IBM Flash Adapter F825 Enterprise Value| N| N| N| Y| Y| Y| N| N| N|
N| N| N
00AE864| IBM Flash Adapter F1650 Enterprise Value| N| N| N| Y| Y| Y| N| N| N|
N| N| N
00AE867| IBM Flash Adapter F3200 Enterprise Value| N| N| N| Y| Y| Y| N| N| N|
N| N| N
Table 3. System x, iDataPlex, and NeXtScale compatibility (Part 2)
Part number| Description|
|
|
| | | | | |
|
| |
---|---|---|---|---|---|---|---|---|---|---|---|---|---
00AE861| IBM Flash Adapter F825 Enterprise Value| N| N| N| N| N| Y| Y| Y| N|
N| N| N
00AE864| IBM Flash Adapter F1650 Enterprise Value| N| N| N| N| N| Y| Y| Y| N|
N| N| N
00AE867| IBM Flash Adapter F3200 Enterprise Value| N| N| N| N| N| Y| Y| Y| N|
N| N| N
See the IBM ServerProven website for the latest compatibility information for System x servers at http://ibm.com/servers/eserver/serverproven/compat/us/.
Supported operating systems
The IBM Flash Adapters Enterprise Value support the following operating
systems:
- Microsoft Windows Server 2008, Enterprise x64 Edition Microsoft Windows Server 2008, Standard x64 Edition Microsoft Windows Server 2008 R2
- Microsoft Windows Server 2012
- Microsoft Windows Server 2012 R2
- Red Hat Enterprise Linux 5 Server x64 Edition
- Red Hat Enterprise Linux 5 Server with Xen x64 Edition
- Red Hat Enterprise Linux 6 Server x64 Edition
- SUSE Linux Enterprise Server 11 for AMD64/EM64T
- SUSE Linux Enterprise Server 11 with Xen for AMD64/EM64T VMware vSphere 5.1 (ESXi)
- VMware vSphere 5.5 (ESXi)
See the IBM ServerProven website for the latest information about the specific versions and service packs supported at http://ibm.com/servers/eserver/serverproven/compat/us/. Click System x servers, then Storage Controllers and SSD adapters to see the support matrix. Click the check mark that is associated with the System x server in question to see the details of the operating system support.
Warranty
The IBM Flash Adapters Enterprise Value carry a 1-year, customer-replaceable unit (CRU) limited warranty. When installed in a supported IBM server, these adapters assume your system’s base warranty and any IBM ServicePac® upgrade.
Physical specifications
The IBM Flash Adapters F825 and F1650 Enterprise Value have the following
physical specifications:
Dimensions and weight (approximate):
- Height: 16 mm (0.6 in.)
- Width: 68 mm (2.7 in.)
- Depth: 167 mm (6.6 in.)
- Weight: 180 g (0.4 lb)
Shipping dimensions and weight (approximate):
- Height: 65 mm (2.6 in.)
- Width: 225 mm (8.9 in.)
- Depth: 245 mm (9.6 in.)
- Weight: 413 g (0.9 lb)
The IBM Flash Adapter F3200 Enterprise Value has the following physical specifications
- : Dimensions and weight (approximate):
- Height: 16 mm (0.6 in.)
- Width: 110 mm (4.3 in.)
- Depth: 167 mm (6.6 in.)
- Weight: 310 g (0.7 lb)
- Shipping dimensions and weight (approximate):
- Height: 65 mm (2.6 in.)
- Width: 225 mm (8.9 in.)
- Depth: 245 mm (9.6 in.)
- Weight: 540 g (1.3 lb)
Operating environment
The IBM Flash Adapters Enterprise Value are supported in the following
environment:
- Temperature (operational): 0 – 55 °C (32 – 131 °F) at 0 – 3,048 m (0 – 10,000 ft)
- Relative humidity: 5 – 95% (non-condensing)
- Maximum altitude (operational): 3,048 m (10,000 ft)
Agency approvals
The IBM Flash Adapters Enterprise Value conform to the following regulations:
- EN55022
- EN55024
- EN60950 / CE
- EN 61000-3-2
- EN 61000-3-3
- IEC 950 CB Scheme
- FCC Part 15 Class A, and Class B UL 1950
- CSA C22.2 950-95
- VCCI
- NZ AS3548 / C-tick
- RRL for MIC (KCC)
- BSMI
- UL 94-/V
Related publications and links
For more information, see the following documents:
-
IBM US Announcement Letter
http://ibm.com/common/ssi/cgi- bin/ssialias?infotype=dd&subtype=ca&&htmlfid=897/ENUS113-177 -
IBM High IOPS SS Class SSD PCIe Adapter Documentation – IBM System x
http://ibm.com/support/entry/portal/docdisplay?lndocid=MIGR-5091557 -
IBM High IOPS System x server configuration information and requirements
http://ibm.com/support/entry/portal/docdisplay?lndocid=SERV-IOPS -
IBM System x Configuration and Options Guide
http://ibm.com/systems/xbc/cog/ -
IBM ServerProven
http://ibm.com/servers/eserver/serverproven/compat/us/
Related product families
Product families related to this document are the following:
- PCIe Flash Adapters
Notices
Lenovo may not offer the products, services, or features discussed in this
document in all countries. Consult your local Lenovo representative for
information on the products and services currently available in your area. Any
reference to a Lenovo product, program, or service is not intended to state or
imply that only that Lenovo product, program, or service may be used. Any
functionally equivalent product, program, or service that does not infringe
any Lenovo intellectual property right may be used instead. However, it is the
user’s responsibility to evaluate and verify the operation of any other
product, program, or service. Lenovo may have patents or pending patent
applications covering subject matter described in this document. The
furnishing of this document does not give you any license to these patents.
You can send license inquiries, in writing, to:
Lenovo (United States), Inc.
8001 Development Drive
Morrisville, NC 27560
U.S.A.
Attention: Lenovo Director of Licensing
LENOVO PROVIDES THIS PUBLICATION ”AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER
EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some
jurisdictions do not allow disclaimer of express or implied warranties in
certain transactions, therefore, this statement may not apply to you.
This information could include technical inaccuracies or typographical errors.
Changes are periodically made to the information herein; these changes will be
incorporated in new editions of the publication. Lenovo may make improvements
and/or changes in the product(s) and/or the program(s) described in this
publication at any time without notice.
The products described in this document are not intended for use in
implantation or other life support applications where malfunction may result
in injury or death to persons. The information contained in this document does
not affect or change Lenovo product specifications or warranties. Nothing in
this document shall operate as an express or implied license or indemnity
under the intellectual property rights of Lenovo or third parties. All
information contained in this document was obtained in specific environments
and is presented as an illustration. The result obtained in other operating
environments may vary. Lenovo may use or distribute any of the information you
supply in any way it believes appropriate without incurring any obligation to
you.
Any references in this publication to non-Lenovo Web sites are provided for
convenience only and do not in any manner serve as an endorsement of those Web
sites. The materials at those Web sites are not part of the materials for this
Lenovo product, and use of those Web sites is at your own risk. Any
performance data contained herein was determined in a controlled environment.
Therefore, the result obtained in other operating environments may vary
significantly. Some measurements may have been made on development-level
systems and there is no guarantee that these measurements will be the same on
generally available systems. Furthermore, some measurements may have been
estimated through extrapolation. Actual results may vary. Users of this
document should verify the applicable data for their specific environment.
© Copyright Lenovo 2022. All rights reserved.
This document, TIPS1089, was created or updated on April 29, 2014.
Send us your comments in one of the following ways:
- Use the online Contact us review form found at: https://lenovopress.lenovo.com/TIPS1089
- Send your comments in an e-mail to: comments@lenovopress.com
This document is available online at https://lenovopress.lenovo.com/TIPS1089.
Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo
in the United States, other countries, or both. A current list of Lenovo
trademarks is available on the Web at
https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other
countries, or both:
Lenovo®
NeXtScale
ServerProven®
System x®
iDataPlex®
The following terms are trademarks of other companies:
Linux® is the trademark of Linus Torvalds in the U.S. and other countries.
Microsoft®, Windows Server®, and Windows® are trademarks of Microsoft
Corporation in the United States, other countries, or both.
Other company, product, or service names may be trademarks or service marks of
others.
References
- Enterprise Business Server Solutions | IBM
- IBM Support
- IBM Support
- IT Infrastructure | IBM
- IT Infrastructure | IBM
- PCIe Flash Adapters > Lenovo Press
- IBM Flash Adapters Enterprise Value for System x Product Guide (withdrawn product) > Lenovo Press
- Copyright and Trademark Information | Lenovo US | Lenovo US
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>