CLEAN COMFORT DV120 Dehumidifier Indoor Air Essentials Installation Guide

June 1, 2024
CLEAN COMFORT

CLEAN COMFORT DV120 Dehumidifier Indoor Air Essentials

Specifications:

  • Model: DV090/DV120
  • Tools Required: 3/8 hex drive, Drill or duct cutting tool, Wire stripper/cutter, Scissors or utility knife, Standard screwdriver, T25 Torx screwdriver, Duct tape, 10 round duct, and starter collar

Product Information

About the DV090/DV120 Dehumidifier

The DV090/DV120 dehumidifier is designed to efficiently remove excess moisture from the air, helping to maintain a comfortable indoor environment.

DV090 Specifications:

  • Model: DV090
  • Filter: MERV 11 (1)
  • Filter Door: 2
  • Installation Guide included
  • Recommended Drain Line: 1/2″ diameter, 8′

DV120 Specifications:

  • Model: DV120
  • Filter: MERV 11 (1)
  • Filter Door: 2
  • Installation Guide included
  • Recommended Drain Line: 1/2″ diameter, 8′

Product Usage Instructions

Installation:

  1. Ensure that installation is performed by a qualified service technician and complies with local codes.
  2. Disconnect power to the device before installing or servicing it.
  3. Follow the detailed installation instructions provided starting from page 5 of the installation guide.

FAQ

Q: Can I install the DV090/DV120 dehumidifier myself?

A: It is recommended to have a qualified service technician perform the installation to ensure compliance with local codes and prevent damage to the device.

INCLUDED IN THIS BOX

CLEAN-COMFORT-DV120-Dehumidifier-Indoor-Air-Essentials-
fig-1

Warning: Only personnel that have been trained to install, adjust, service or repair (hereinafter, “service”) the equipment specified in this manual should service the equipment. The manufacturer and seller will not be responsible for any injury or property damage arising from improper service or service procedures. If you service this unit, you assume responsibility for any injury or property damage which may result. In addition, in jurisdictions that require one or more licenses to service the equipment specified in this manual, only licensed personnel should service the equipment. Improper installation, adjustment, servicing or repair of the equipment specified in this manual, or attempting to install, adjust, service or repair the equipment specified in this manual without proper training may result in product damage, property damage, personal injury or death.

Installation Checklist

Included in This Box

  • A DV090 (1) or DV120 (1)
  • B MERV 11 Filter (1)
  • C Filter Door (2)
  • D Installation Guide

Tools Required (Not Supplied)

  • 3/8” hex drive
  • Drill or duct cutting tool
  • Wire stripper/cutter
  • Scissors or utility knife
  • Standard screwdriver
  • T25 Torx screwdriver
  • Duct tape
  • 10” round duct and starter collar
  • 18-22 gauge, 5 band thermostat wire
  • 1/2” diameter drain line (8’)
  • 1/2” drain clamps (2)
  • 3/4” male NPT to drain line adaptor (1/2” Dia. recommended)

Options

  • 1/2” drain p-trap (may be required by local code)
  •  Drain pan
  • Float switch or water sensor

Warning: Installation must be performed by a qualified service technician and must comply with local codes.
Remove power to the device before installing or servicing the device.
Failure to connect the device according to these instructions may result in damage to the device or the controls.

INSTALLATION INSTRUCTIONS
BEGIN ON PAGE 5

  • The DV090/DV120 is designed to be installed indoors in a space that is protected from rain and flooding.
  • Install the unit with space to access the front panel for maintenance and service.
  • Avoid directing the discharge air at people, or over the water in pool areas.
  • If used near a pool or spa, be certain there is no chance the unit could fall into the water or be splashed, and that it is plugged into a ground fault interrupt (GFI) outlet.
  • To ensure quiet operation, do not place the device directly on the structural supports of the home.
  • A drain pan must be placed under the unit if installed above a living area or above an area where water leakage could cause damage.
  1.  Never operate a unit with a damaged power cord. If the power cord is damaged it must be replaced by the manufacturer, its service agent, or similarly qualified person in order to avoid a hazard.
  2.  The appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.

NEED HELP? For assistance with this product please visit http://www.CleanComfort.com or call Customer Care toll-free at 1-833-40-CLEAN.

Read and save these instructions.

® U.S. Registered Trademark. Patents pending. Copyright © 2020 Goodman Manufacturing Company, L.P. All rights reserved.

DV090/DV120 Dehumidification System 33-00547ES—01

About the DV090/DV120 Dehumidifier

Benefits

  • Removes up to 90 (DV090) or 120 (DV120) pints of water per day from the indoor air
  • Built-in fresh air supply
  • Built-in transformer circuit breaker

CLEAN-COMFORT-DV120-Dehumidifier-Indoor-Air-Essentials-
fig-2

Maintaining Ideal Humidity
Dew points and relative humidity (RH) affect the way your body senses heat. Higher humidity levels cause the air to feel much hotter than the actual temperature. When maintained properly, your cooling equipment may not run as much because dehumidified air feels cooler. Ideal humidity is defined by American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) as being between 40-60% on an average annual basis.

WHAT THE AIR FEELS LIKE
HOW HOT THE HEAT-HUMIDITY COMBINATION MAKES IT FEEL.
EXAMPLE: AIR AT 90ºF WITH 50% RH FEELS LIKE 96ºF TO THE HUMAN BODY!

CLEAN-COMFORT-DV120-Dehumidifier-Indoor-Air-Essentials-
fig-3

DV090 Specifications

Install DV090 according to National Electric Codes.

Dry-Bulb Temp Intake Humidity Capacity (Pints/Day)
80°F (26.7°C) 60% RH 120
70°F (21.1°C) 60% RH 88
60°F (15.6°C) 60% RH 63
Home Size (square ft [m]) Dehumidifier Capacity Required

to Maintain Desired Indoor **RH*
---|---
60% RH Indoor (pints/day)| 50% RH Indoor (pints/day)| 40% RH Indoor (pints/day)**
2080 (193.2)| 49–54| 55–58| 71–78
2600 (241.5)| 61–68| 65–72| 90–97
3120 (289.9)| 75–82| 79–86| 95–110

  • Based on extreme climates where outdoor humidity is 70-90% RH. For less extreme climates, larger homes can be adequately served with less capacity. Actual requirements may vary.

Dimensions in inches and (mm)

CLEAN-COMFORT-DV120-Dehumidifier-Indoor-Air-Essentials-
fig-4

  • Product weight: 86 lbs.

  • Shipping weight: 95 lbs.

  • Shipping dimensions: 25.2” H × 19.3” W × 35.8” L

  • Media Filter: MERV 11, 14” H × 17.5” W × 1.75” L

  • Drain connection: 3/4” threaded female NPT connection. Duct connections: 10” round inlet and outlet. 6” supply inlet.
    ABS plastic, compatible for connection to rigid or flexible ducting with sheet metal screws and/or tape.

  • Cabinet: 20 ga

  • Insulation: R value 1

  • Compressor: Rotary, 7.3 KBTU

  • Refrigerant: R-410A, 25 oz

  • Operating Temp Range (outside cabinet): 34ºF to 135ºF (1.1ºC to 57.2ºC)

  • Operating Humidity Range: 0-99% RH

Airflow versus external static pressure (0–1 in. [0 – 25.4 mm] water pressure) with collars attached

0 in. (0 mm) 400 CFM
0.2 in. (5 mm) 345 CFM
0.4 in. (10 mm) 295 CFM
0.6 in. (15.2 mm) 250 CFM

Input ratings

  • Electrical input voltage: 120 VAC, 60 Hz nominal
  • Input current: 5.3 A

Output ratings

  • Power transformer to R/C terminals: 24 VAC, 0.85 A
  • Energy Performance: 2.9 liters (6.1 pints) per kilowatt hour (KWH)

Install DV120 according to National Electric Codes.

Install to Fit Your Application

Flex duct is recommended in connecting to the DV090/DV120 collars to reduce vibration noise.

CLEAN-COMFORT-DV120-Dehumidifier-Indoor-Air-Essentials-
fig-2

Duct Sizing: Use minimum 10” diameter round for duct lengths up to 25’ Minimum 12” required for lengths longer than 25’ Duct branches from the main inlet/exhaust should be minimum 10” round for 2-3 branches, and 12” round or larger for 4 branches or more.
For the optional fresh air ventilator port, use 6” round, insulated duct for lengths up to 50’ Use 8” round duct for more than 50’ of if more than 100 CFM is required.

Isolated Areas: Effective dehumidification may require ducting to isolated or stagnant air flow areas.

Electrical requirements:
115 VAC outlet. Ground fault interrupter (GFI) recommended.

Dedicated Return to Main Supply

CLEAN-COMFORT-DV120-Dehumidifier-Indoor-Air-Essentials-
fig-6 Ideal when…

  • Access to dedicated central return for dehumidifier is available.
  • Combined with A/C operation, requires backdraft damper on the exhaust port to minimize backdraft when dehumidifier is not on but A/C is.
  • (optional) Duct humidifier supply with 20% open gravity damper to provide dry air to a specific area

Main Return to Main Supply

CLEAN-COMFORT-DV120-Dehumidifier-Indoor-Air-Essentials-
fig-7 Ideal when…

  • Running dehumidifier when not running A/C.
  • Requires damper on the exhaust port to minimize backdraft when DV090/DV120 is not on but A/C is.
  • Access to a dedicated central return is not possible.
  • System fan should run with dehumidifier for best results.

Main Return to Main Return

CLEAN-COMFORT-DV120-Dehumidifier-Indoor-Air-Essentials-
fig-8

Ideal when…

  • Running DV090/DV120 with A/C operation.
  • Minimizing discharge air temperature (DAT) increase is preferred.
  • Access to a dedicated return is not possible.

Dedicated Return to Dedicated Supply

Ideal when…

The dehumidifier will not be ducted to a forced air HVAC system.

Plumbing

Attach 3/4” male NPT drain nozzle.
Connect 1/2” drain tube to male connection drain outlet. Secure drain tube to connector with hose clamp.
Run drain hose continuously downhill to an approved drain or condensate pump.
The drain line must include a water trap to prevent air from entering or exiting the dehumidifier.

Terminal Description

CAUTION: Low voltage hazard.
Can cause equipment damage.
Disconnect HVAC equipment before beginning installation.

CLEAN-COMFORT-DV120-Dehumidifier-Indoor-Air-Essentials-
fig-11

NOTE: The outer screws on the terminal block secure the block to the chassis. They are not used for wiring.
A wiring terminal block is located on the side panel of the dehumidifier unit.
The six terminals for the terminal block (reading from left to right in the photo) are:

  • FLOAT: External low voltage float switch or water sensor (two terminals). Use normally closed switch.
  • DHUM: Compressor and fan operation for dehumidification
  • R: DV090/DV120 24V output
  • FAN: Fan activation only for ventilation
  • C: DV090/DV120 24V output External 24V devices can be powered from R and C terminals (20VA max.)

Wiring

Wire the DV090/DV120 according to the diagram that applies to your desired operation.

CLEAN-COMFORT-DV120-Dehumidifier-Indoor-Air-Essentials-
fig-13

Checkout
Apply power to DV090/DV120. Turn the humidity control to a low RH% level to initiate a dehumidification call. Confirm that the DV090/DV120 compressor and fan turn on. The furnace blower will also turn on to circulate air. This will take up to two minutes. Be sure to turn the control to the desired RH% or to Off when checkout is complete.
If using for ventilation, initiate a call for ventilation. Confirm that the DV090/DV120 fan turned on, but that the compressor remained off.

Cleaning

On an annual basis, perform the following maintenance requirement to ensure the dehumidifier runs at peak efficiency.

  1. Unplug DV090/DV120 before beginning service. Remove the magnetic filter door.
  2. Remove filter and replace with new filter.
  3. Check the drain connection and drain line to ensure it is clear of debris and sludge. Ensure all hose connections are secure once maintenance of the drain lines is complete.
  4. When service is complete, initiate a call for dehumidification and check that the compressor and fan activate. If your thermostat has maintenance reminders, reset those.

CLEAN-COMFORT-DV120-Dehumidifier-Indoor-Air-Essentials-
fig-14

Technical Description
DV090/DV120 uses a refrigeration system similar to an air conditioner to remove heat and moisture from incoming air and add heat to the air that is discharged. Hot, high-pressure refrigerant gas is routed from the compressor to the condenser coil. The refrigerant is cooled and condensed by giving up its heat to the air that is about to be discharged from the unit. The refrigerant liquid then passes through a filter drier and capillary tubing which causes the refrigerant pressure and temperature to drop. It next enters the evaporator coil where it absorbs heat from the incoming air and evaporates. The evaporator operates in a flooded condition, which means that all the evaporator tubes contain liquid refrigerant during normal operation. A flooded evaporator should maintain nearly constant pressure and temperature across the entire coil, from inlet to outlet.

CLEAN-COMFORT-DV120-Dehumidifier-Indoor-Air-Essentials-
fig-15

Troubleshooting

CAUTION: Servicing the DV090/DV120 with its high pressure refrigerant system and high voltage circuitry presents a health hazard which could result in death, serious bodily injury, and/or property damage. Service should only be performed by a qualified service technician.

Problem Recommended Troubleshooting Steps

No dehumidification. Neither fan nor compressor run and the ventilation timer is OFF.| 1.      Unit unplugged or no power to outlet.

2.      Humidity control set too high or defective.

3.      Loose connection in internal or control wiring.

4.      Defective compressor relay.

5.      Defective control transformer.

6.      Optional Condensate Pump Safety Switch open.

No dehumidification. Compressor does not run but fan runs when there is a call for dehumidification and the ventilation control is OFF.| 1.      Defective compressor run capacitor.

2.      Bad connection in compressor circuit.

3.      Defective compressor overload.

4.      Defective compressor.

5.      Defrost thermostat open.

6.      Optional Condensate Pump Safety Switch open.

Fan runs when there is a call for dehumidification and the

ventilation control is OFF, but the compressor cycles on and off too frequently.

| 1.      Low ambient temperature and/or humidity causing unit to cycle through defrost mode.

2.      Defective compressor overload.

3.      Defective compressor.

4.      Defrost thermostat defective.

5.      Dirty air filter(s) or airflow restricted.

6.      Low refrigerant charge, causing defrost control to cycle.

7.      Bad connection in compressor circuit. Fan does not run with fan switch in either position.

Problem Recommended Troubleshooting Steps

Fan does not run with ventilation activated.

Compressor runs briefly but cycles on & off with humidity control turned to ON.

| 1.      Loose connection in fan circuit.

2.      Obstruction prevents fan rotation.

3.      Defective fan.

4.      Defective fan relay.

5.      Defective fan capacitor.

Evaporator coil frosted

continuously, low de-humidifying capacity.

| 1.      Defrost thermostat loose or defective.

2.      Low refrigerant charge.

3.      Dirty air filter(s) or airflow restricted.

Unit not providing ventilation.| 1.      Check control wire connections (check connections at fresh air damper also).

2.      Defective fresh air damper.

3.      Dirty air intake. Clean outside intake hood.

Unit removes some water, but not as much as expected.| 1.      Air temperature and/or humidity have dropped.

2.      Humidity meter and or thermometer used are out of calibration.

3.      Unit has entered defrost cycle.

4.      Dirty air filter.

5.      Defective defrost thermostat.

6.      Low refrigerant charge.

7.      Air leak such as loose cover or ducting leaks.

8.      Defective compressor.

9.      Restrictive ducting.

10.  Optional Condensate Pump Safety Switch open.

Unit Test to determine problem:| 1.      Detach field control wiring connections from main unit.

2.      Connect the R and FAN contacts from the main unit together; only the impeller fan should run. Disconnect the wires.

3.      Connect the R and DHUM contacts from the main unit together; the compressor and impeller fan should run.

4.      If these tests work, the main unit is working properly. You should check the control panel and field control wiring for problems next.

5.      Remove the control panel from the mounting box and detach it from the field installed control wiring. Connect the blue, yellow, and green wires from the control panel directly to the corresponding colored pigtails on the main unit. Leave the violet, white, and red wires disconnected!

6.      Turn on the humidity control. The compressor and impeller fan should run.

7.      If these tests work, the problem is most likely in the field control wiring.

DV090/DV120 Parts List

Figure Reference Base and Accessory Parts Part Number
1 Dehumidifier DV090
2 Dehumidifier DV120
3 Filter DV50070171

CLEAN-COMFORT-DV120-Dehumidifier-Indoor-Air-Essentials-
fig-16

Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. © 2020 Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in China.
WWW.CLEANCOMFORT.COM • TECHNICAL SUPPORT: 1-833-40-CLEAN (25326)