Wolf Gordon GATHER Z-Clip Hardware Acoustical Panels Installation Guide

June 13, 2024
Wolf Gordon

Wolf Gordon GATHER Z-Clip Hardware Acoustical Panels

For use with GATHER Acoustical Panels

Installation for GATHER Acoustical panels is to be provided by a professional with extensive experience installing wallcovering, wall and ceiling-hung panels, and other Division 10 Specialty items.

Z-Clips can be used for conditions where GATHER Acoustical panels will need to be  removable from walls. Z-Clips are 1-1/2″ wide and approx. 2″ high. Z-Clip Rails are 72″long. Both are available from Wolf-Gordon.

DIMENSIONS

Dimensions

INSTALLATION INSTRUCTIONS

  • Z-clips should be set at a height determined by a cross line laser level line set at the existing partition.
  • If using a Z-Clip Rail, attach the hanging rail to the existing wall first.
  • Z-Clips should be placed no closer than 2-3″ from the top or side edges of the panel. The panel width will determine the number of clips needed on the back side. We recommend using three clips for a 4′-wide panel.
  • Fasten Z-clips to the panels using zippy screws (purchase separately) with the open edge facing downward to match the open end of the Z-Clip Rail attached to the wall.
  • A correct installation with Z-Clips will result in a ¼” gap between the panel and the wall.
    Having a utility knife and a 4-foot non-slip straightedge with a 90º angle onsite will be handy to make cuts to and trim panels. A 4–6-foot ladder is also recommended.

Note: The information above is intended only as a guideline. The installer has the final responsibility for proper installation and evaluation of jobsite conditions.

Wolf Gordon Logo Wolf Gordon Logo

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals