KARCHER SP 5 Dirt SP Dirt Submersible Sludge Pump Box Instruction Manual
- June 3, 2024
- Karcher
Table of Contents
makes a difference
SP 5 Dirt SP 7 Dirt
|
---|---
SP 5 Dirt SP Dirt Submersible Sludge Pump Box
Please read and comply with these original operating instructions and the enclosed safety instructions. Proceed accordingly. Keep both booklets for future reference or subsequent owners.
Warranty
The warranty terms published by the relevant sales company are applicable in
each country. We will repair potential failures of your appliance within the
warranty period free of charge, provided that such failure is caused by faulty
material or defects in manufacturing. In the event of a warranty claim please
contact your dealer or the nearest authorized Customer Service center.
Please submit the proof of purchase.
The adhesive-type label must not be removed from the device. Warranty is no
longer granted if the label is removed.
Environmental protection
**** The packaging material can be recycled. Please do not place the packaging into the ordinary refuse for disposal, but arrange for the proper recycling.
Old appliances contain valuable materials that can be recycled. Please arrange
for the proper recycling of old appliances. Please dispose of your old
appliances using appropriate collection systems.
Notes about the ingredients (REACH)
You will find current information about the ingredients at:
www.kaercher.com/REACH
Description of the Appliance
- Carrying handle
- Power cord with plug
- Lock (float switch)
- Height adjustment (float switch)
- Swimmer switch
- Automatic venting device
- Quick-Connect
- Connection nozzle (1¼“ hose connection and G1 thread SP 5 Dirt)
- Connection nozzle (G1½ – thread SP 7 Dirt)
- Pump connecting pieces (1“, 1¼“ and 1½“ hose connection and G1½ – thread SP 7 Dirt)
- Pre-filter (SP 7 Dirt)
Proper use
This appliance has been designed for use in private households and is not
intended for commercial use. The manufacturer is not responsible for any
damages that may occur on account of improper use or wrong operations. The
device is mainly intended for draining building parts in case of flooding, but
also for pumping over or out containers, for water removal from wells and
shafts as well as for draining water from boats and yachts, provided that it
is fresh water.
NOTICE
The device is not suitable for continuous pump operation (e.g. continuous
circulation in a pond) or as a stationary installation (e.g. lifting device,
fountain pump).
Approved feed fluids
-
Freshwater up to a certain degree of soiling
-
Water from the swimming pool (provided the dosing of additives is proper)
-
Washing lye
SP 5 Dirt -
Water with a degree of contamination up to a grain
size of 20 mm
SP 7 Dirt -
Water with a degree of contamination up to a grain
size of 30 mm
DANGER
Risk of injury, risk of damage! Caustic, slightly inflammable, and other
explosive substances (such as petrol, petroleum, diluted nitrogen), greases,
oils, salt water, and wastewater from toilets as well as sludgy water that has
a slower flow capacity than water, must not be transported with this pump. The
temperature of the delivered fluid must be between 5 °C and 35 °C.
Startup
NOTICE
The shorter the hose length and the larger the hose diameter, the higher the
pump capacity.
To prevent clogging of the pump, use a prefilter with hose diameters of less
than 1¼ “.
-
SP 5 Dirt, special accessories
-
SP 7 Dirt, integrated into the base
The pump connection is equipped with a plug system (Quick-Connect).
The unmounted connection nozzle (SP 5 Dirt) or the connection nozzle with pump connecting piece (SP 7 Dirt) is enclosed in the device.
Illustration A -
To remove the connection nozzle, press the QuickConnect (grey button).
Illustration B
(SP 5 Dirt)
-
Slide the hose clamp onto the hose.
If a ¾“ or 1“ hose is used: -
Screw the pump connecting piece (see special accessory) onto the connection nozzle.
-
Slide the hose onto the pump connecting piece and secure it by means of a hose clamp.
-
Slide the connection nozzle into the Quick-Connect.
NOTICE
To increase the flow volume, the pump connecting piece can be shortened according to the hose used.
If a 1¼ “ hose is used:
-
Slide the hose onto the connection nozzle and secure it by means of a hose clamp.
-
Slide the connection nozzle into the Quick-Connect.
Illustration C
(SP 7 Dirt) -
Screw the pump connecting piece onto the connection nozzle.
-
Slide the hose clamp onto the hose.
-
Slide the hose onto the pump connecting piece and secure it by means of a hose clamp
-
Slide the connection nozzle into the Quick-Connect.
NOTICE
Hoses with a diameter of 1“, 1¼“, and 1½“ can be connected to the pump
connecting piece.
To increase the flow volume, the pump connecting piece can be shortened
according to the hose used.
Illustration E
- Snap the float switch into the height adjustment.
- Safely place the pump on a stable surface in the feed fluid or immerse it using a rope tied to the carrying handle.
NOTICE
The suction area must not be blocked by soil.
In case of muddy ground, place the pump on a brick or the like.
Ensure that the pump is level.
Do not carry the pump on the cable or the hose.
Operation
DANGER
Risk of mortal danger on account of electric shock!
Do not touch feed fluids, the rope attached to the carrying handle as well as
objects that are in contact with the feed fluid (e.g. pipelines extending into
the water, railings, etc.).
Automatic venting device
Illustration D
With a low fluid level, possibly drawn air or air that is present in the pump
escapes via the automatic venting device. In addition, fluid may leak at this
spot. If the pump has suction problems with a low fluid level, unplug and
plug in the mains plug repeatedly in order to support the suction process.
Automatic operation
Illustration G
- Adjust the float switch via the height adjustment and the cable length between the float switch and height adjustment.
NOTICE
In the automatic mode, the float switch controls the pumping operations automatically.
The pump switches on as soon as the float switch has reached the switch-on height due to the rising fluid level. The pump switches off as soon as the float switch has reached the switch-off height due to the falling fluid level. Ensure that the float switch is not obstructed in any way. The cable between the float switch and the lock must be at least 2.5 cm long.
Switch-on height / switch-off height (float switch in the lowest position):
Min / Max | SP 5 Dirt | SP 7 Dirt |
---|---|---|
Switch-on height | 18 / 21 cm | 20 / 24 cm |
Switch-off height | 4 / 12 cm | 6 / 15 cm |
Switch-on height / switch-off height (float switch in
Min / Max| SP 5 Dirt| SP 7 Dirt
Switch-on height| 28 / 31 cm| 33 / 36 cm
Switch-off height| 14 / 22 cm| 19 / 27 cm
*The switching height can vary depending on the position of the float switch.
Likewise, the cable length between the float switch and the lock can influence
the switching heights. We recommend retaining the preset cable length.
- Insert the mains plug into the socket.
Manual operation
Illustration F
-
Secure the nose on the float switch into the opening of the lock pointing up.
NOTICE
In manual operation, the pump remains switched on continuously. -
In order that the pump draws independently in manual operation, the fluid level must be at least 60 mm (SP 5 Dirt) or 50 mm (SP 7 Dirt).
The pump can pump up to a residual fluid height of 25 mm (SP 5 Dirt) or 35 mm
(SP 7 Dirt).
The stated residual fluid height is only achieved in manual operation.
- Insert the mains plug into the socket.
ATTENTION
Risk of damage! Dry running leads to increased wear;
never leave the pump unattended during manual operation. Switch off immediately in case of dry running.
Finish operation
NOTICE
Soiling can deposit and lead to malfunctions.
-
Pump clear water or thoroughly rinse the pump after every use.
This especially applies after pumping chlorinated water or other liquids that leave a residue. -
Disconnect the main plug from the socket.
Maintenance
The pump is maintenance-free.
Transport
CAUTION
In order to prevent accidents or injuries, keep in mind the weight of the
appliance during transport (see Specifications).
- Lift and carry the pump on the carrying handle.
- If you want to transport the appliance on a vehicle secure it from slipping.
Storage
CAUTION
In order to prevent accidents or injuries, keep in mind the weight of the
appliance when selecting a storage location for it (see Specifications).
Storing the pump
- Completely drain the pump and allow it to dry.
- Store the pump in a frost-free place.
Special accessories
2.997-100.0| Braided hose set| Flexible 1 1/4“ braided hose with hose clamp
(30 – 40 mm) with wing screw for a connection without tools.
Especially recommendable for immersion pumps when removing large water
quantities. Max. operating pressure: 5 bar
---|---|---
2.997-201.0| Prefilter for immersion pump, small| The robust prefilter is easy
to attach and protects your immersion pump, which increases functional
reliability. (SP 5 Dirt)
6.997-359.0| Pump connection G1 (33.3 mm) incl. Check valve| For pumps with G1
(33.3 mm) connection thread and 3/4″ as well as 1″ hoses, including union nut,
hose clamp, flat packing, and check valve. (SP 5 Dirt)
6.997-347.0| Spiral hose, by the meter, 25 m, 3/4″| By the meter for cutting
hoses to individual lengths. (SP 5 Dirt)
6.997-346.0| Spiral hose, by the meter, 25 m, 1″| By the meter for cutting
hoses to individual lengths.
2.645-142.0| Hose PrimoFlex, 25 m, 3/4″| Phthalate-free 3/4″ garden hose for
draining away the water. (SP 5 Dirt)
2.645-247.0| Hose PrimoFlex, 50 m, 1″| Phthalate-free 1″ garden hose for
draining away the water.
Troubleshooting
DANGER
Risk of mortal danger on account of electric shock!
To avoid risks, all repairs and replacement of spare parts may only be carried
out by authorized customer service personnel.
Fault | Cause | Remedy |
---|---|---|
The pump runs but does not transport | Air in the pump | Unplug and plug in the |
mains plug of the pump repeatedly until the fluid is drawn
Suction area blocked| Pull out the mains plug and clean the suction area
Water level below the minimum fluid level (only in manual operation)|
Immerse, whenever possible, the pump deeper into the feed fluid or proceed as
described in Chapter Operation.
Fault| Cause| Remedy
---|---|---
The pump does not run or suddenly comes to a standstill during operations|
Power supply interrupted| Check fuses and electrical connector options
The thermal protection switch has switched off the pump due to overheating|
Pull out the mains plug, let the pump cool down, clean the suction area, and
prevent dry running
Dirt particles have got jammed into the| Pull out the mains plug and clean the
suction area
Pumping capacity is reducing| Suction area blocked| Pull out the mains plug
and clean the suction area
Pumping capacity too low| The pumping capacity depends on the| Observe the
maximum delivery height, see technical data. If necessary, use a larger hose
diameter or a shorter hose length.
Quick-Connect cannot be opened or closed.| Soiling in the plug system.| Remove
and clean the clip.
Specifications
| SP 5 Dirt| SP 7 Dirt
---|---|---
Mains voltage| V| 230 – 240 V| 230 V
Mains frequency| Hz| 50| 50
Output Phnom| W| 500| 750
Max. flow rate| l/h| 9500| 15500
Max. pressure| bar| 0,7| 0,8
Max. flow height| m| 7| 8
Max. immersion depth| m| 7| 7
Max. grain size of the dirt particles that can be transported| mm| 20| 30
Minimum fluid height (manual mode)| mm| 60| 50
Residual fluid height| mm| 25| 35
Weight (without accessories)| kg| 4,6| 6,5
Subject to technical modifications!| | |
The possible delivery rate is even larger:
– the lower the delivery height
– the larger the diameter of the hose used
– the shorter the hose used
– the lower the pressure loss caused by the connected accessories
Register your product and benefit from many advantages.
www.kaercher.com/welcome
Rate your product and tell us your opinion.
****www.kaercher.com/dealersearch
Alfred Kärcher SE & Co. KG
Alfred-Kärcher-Str. 28-40
71364 Winnenden (Germany)
Tel.: +49 7195 14-0
Fax: +49 7195 14-2212
Register
your product
www.kaercher.com/welcome
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>