Lenovo E1012 Disk Expansion Enclosures User Guide
- June 3, 2024
- Lenovo
Table of Contents
- Key features
- Components and connectors
- System specifications
- Models
- Connectivity topology
- Drives
- Physical specifications
- Operating environment
- Warranty
- Regulatory compliance
- Rack cabinets
- Power distribution units
- Notices
- Trademarks
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
E1012 Disk Expansion Enclosures
User Guide
The Lenovo Storage E1012 and E1024 Disk Expansion Enclosures offer universal
storage expansion capabilities that are designed to provide simplicity, speed,
scalability, security, and high availability for small to large businesses.
The E1012 and E1024 deliver enterprise-class storage technology in a cost-
effective solution with flexible drive configurations and RAID or JBOD (non-
RAID) host connectivity or Lenovo storage area network (SAN) array expansion.
The E1012 and E1024 expansion units are designed for a wide range of
workloads, including big data and analytics, video surveillance, media
streaming, private clouds, file and print serving, e-mail and collaboration,
and databases.
Figure 1. Lenovo Storage E1012 and E1024 Disk Expansion Enclosures
Did you know?
The E1012 and E1024 expansion enclosures offer flexible drive configurations
with the choice of 2.5-inch and 3.5-inch drive form factors, 10K or 15K rpm
SAS and 7.2K rpm NL SAS hard disk drives (HDDs), and self-encrypting drives
(SEDs), and SAS solid-state drives (SSDs).
With support for daisy chaining, the E1012 can be scaled up to 960 TB for
capacity-optimized configurations, and the E1024 can be scaled up to 192
drives for performance-optimized configurations.
The E1012 and E1024 expansion units are universal enclosures that can be used
with Lenovo System x and ThinkServer systems as direct attach storage (DAS) or
as an expansion for the Lenovo Storage S2200 and S3200 storage area network
(SAN) arrays.
Lenovo Storage E1012 and E1024 Disk Expansion Enclosures (withdrawn product)
Key features
Key features and benefits provided by the E1012 and E1024 storage expansion enclosures include:
- Versatile, scalable storage expansion with a single I/O module for entry-level solutions or dual I/O module configurations for high availability and performance
- Flexible host connectivity to match diverse client needs for direct attach storage with support for 6 Gb or 12 Gb SAS RAID adapters for advanced data protection or 6 Gb
- SAS Host Bus Adapter (HBA) for maximum JBOD performance
- Provide expansion capabilities and share common parts with the S2200 and S3200 SAN arrays 6 Gb SAS drive-side connectivity with support for 12x 3.5-inch large form factor (LFF) drives in the E1012 enclosure or 24x 2.5-inch small form factor (SFF) drives in the E1024 enclosure Scalability of up to 96 LFF or 192 SFF drives per RAID adapter with the attachment of up to eight E1012 or E1024 daisy-chained expansion enclosures to satisfy growing needs for storage capacity and performance
- Flexibility in storing data on high-performance SAS SSDs, performance-optimized enterprise SAS HDDs, or capacity-optimized enterprise NL SAS HDDs; mixing and matching drive types and form factors on a single RAID adapter to perfectly meet performance and capacity requirements for various workloads
- Self-encrypting drives with a supported RAID adapter allow clients to secure their sensitive data and to comply with various security regulations when required
- Designed to comply with NEBS and MIL-STD requirements Designed for 99.999% availability
The E1012 and E1024 are designed to support the complete range of data storage requirements, from highly utilized applications to high-capacity, low-usage applications.
- The following 3.5-inch SAS drives are supported by the E1012:
- High-performance solid-state drives (10 drive writes per day [DWD]): 400 GB
- Performance-optimized, enterprise-class disk drives: 600 GB and 900 GB 10K rpm
- High-capacity, archival-class nearline disk drives: 2 TB, 4 TB, 6 TB, 8 TB, and 10 TB 7.2K rpm
- The following 2.5-inch SAS drives are supported by the E1024:
- High-performance solid-state drives (3 DWD and 10 DWD): 400 GB, 800 GB, and 1.6 TB
- High-performance self-encrypting solid-state drives (10 DWD): 400 GB and 800 GB
- Capacity-optimized solid-state drives (1 DWD): 3.84 TB
- Performance-optimized, enterprise-class disk drives 300 GB and 600 GB 15K rpm 600 GB, 900 GB, 1.2 TB, and 1.8 TB 10K rpm
- High-capacity, archival-class nearline disk drives: 1 TB and 2 TB 7.2K rpm
Additional drives and expansion units are designed to be dynamically added with virtually no downtime (operating system dependent), helping to quickly and seamlessly respond to growing capacity demands.
The E1012 and E1024 expansion enclosures are designed to offer high levels of system and data availability with the following technologies:
- Dual I/O modules provide redundant paths from a supported RAID controller to the drives in the enclosures for I/O load balancing and failover
- Dual-port drives (both HDDs and SSDs) with automatic drive failure detection and RAID rebuild with global hot spares with a supported RAID adapter
- Redundant hardware, including host ports, I/O modules, power supplies, and fans
- Hot-swappable and customer replaceable components, including I/O modules, power supplies with fans, and drives
Components and connectors
The following figure shows the front of the E1012 drive expansion enclosure.
Figure 2. Front view of the E1012 drive enclosure
The following figure shows the front of the E1024 drive expansion enclosure.
Figure 3. Front view of the E1024 drive enclosure
The following figure shows the rear of the E1012 and E1024 drive enclosures
with dual I/O expansion modules. Single I/O module configurations are also
supported.
Figure 4. Rear view of the E1012 and E1024 drive enclosures
Note: The expansion modules (shown in Figure 4) have additional service
ports with a specialized connector, and these ports are reserved for use by a
Lenovo service technician.
System specifications
The following table lists the E1012 and E1024 system specifications.
Table 1. System specifications
Components | Specification |
---|---|
Form factor | 2U rack mount |
110 expansion configuration | Single or dual I/O Expansion Module |
configurations are supported. Single I/O Module enclosures can be upgraded to
dual I/O Module enclosures non-disruptively.
Drive bays| • E1012: 12 LFF hot-swap drive bays; up to 8x E1012 enclosures can
be daisy chained on a supported RAID adapter for a total of up to 96 LFF
drives.
• E1024: 24 SFF hot-swap drive bays; up to 8x E1024 enclosures can be daisy
chained on a supported RAID adapter for a total of up to 192 SFF drives.
An intermix of SFF and LFF enclosures is supported.
Drive technologies| SAS and NL SAS HDDs and SEDs; eMLC SAS SSDs. An intermix
of HDDs, SEDs, and SSDs is supported within an enclosure, but not within a
RAID array.
Drive connectivity| Dual-ported 6 Gb SAS drive attachment infrastructure:
• E1012: 12x 6 Gb SAS internal drive ports per 110 Expansion Module
• E1024: 24x 6 Gb SAS internal drive ports per I/O Expansion Module
• 2x 6 Gb SAS x4 (Mini-SAS SFF-8088) expansion ports (IN and OUT) per I/O
Expansion Module for the daisy-chained attachment of the drive enclosures
Drives| SFF drives:
• 400 GB, 800 GB, and 1.6 TB SAS SSDs (3 DWD and 10 DWD)
• 400 GB and 800 GB SAS SED SSDs (10 DWD)
• 3.84 TB SAS SSDs (1 DWD)
• 300 GB and 600 GB 15K rpm SAS HDDs
• 600 GB, 900 GB, 1.2 TB, and 1.8 TB 10K rpm SAS HDDs
• 1 TB and 2 TB 7.2K rpm NL SAS HDDs
LFF drives:
• 400 GB SAS SSDs (10 DWD)
• 600 GB and 900 GB 10K rpm SAS HDDs
• 2 TB, 4 TB, 6 TB, 8 TB, and 10 TB 7.2K rpm NL SAS HDDs
---|---
Storage capacity| • E1012: Up to 960 TB (96x 10 TB LFF NL SAS HDDs)
• E1024: Up to 737 TB (192x 3.84 TB SFF SAS SSDs)
Host connectivity| lx 6112 Gb SAS host port (IN) (Mini-SAS SFF-8088) per I/O
Expansion Module
Host adapters| • 6Gb SAS HBA (2-port 6 Gb SAS; non-RAID)
• ServeRAID M5120 (2-port 6Gb SAS; RAID 0, 1, 10, 5, 50; optional RAID 6, 60)
• ServeRAID M5225 (2-port 12 Gb SAS; RAID 0, 1, 10, 5, 50; optional RAID 6,
60)
• ThinkServer 9280-8e (2-port 6Gb SAS; RAID 0, 1, 10, 5, 50, 6, 60)
• ThinkServer 9286CV-8e (2-port 6Gb SAS; RAID 0, 1, 10, 5, 50, 6, 60)
Host operating systems| Microsoft Windows Server 2008 R2, 2012 and 2012 R2;
Red Hat Enterprise Linux (RHEL) 5, 6, and 7; SUSE Linux Enterprise Server
(SLES) 10, 11, and 12; VMware vSphere 5.1, 5.5, and 6.0.
Cooling| Redundant cooling with two fans that are built into power supplies.
Power supply| Two redundant hot-swap 595 W AC power supplies.
Hot-swap parts| I/O expansion modules, drives, power supplies/fans.
Management interfaces| SAS Enclosure Services
Security features| Self-encrypting drives (SEDs)
Warranty| Three-year customer-replaceable unit, parts only limited warranty
with 9×5 next business day.
Service and support| Optional warranty service upgrades are available through
Lenovo: on-site support, 24×7 coverage, 4-hour response time, 1-year or 2-year
warranty extensions, and Hard Drive Retention.
Dimensions| • E1012: Height: 87 mm (3.4 in), width: 447 mm (17.6 in), depth:
523 mm (20.6 in)
• E1024: Height: 89 mm (3.5 in), width: 447 mm (17.6 in), depth: 519 mm (20.5
in)
Weight| • E1012: Minimum: 16.8 kg (37.0 lb); Maximum: 26.6 kg (58.6 lb)
• E1024: Minimum: 16.9 kg (37.2 lb); Maximum: 23.4 kg (51.6 lb
Models
Product availability: The E1012 and E1024 expansion units are withdrawn
and no longer available for ordering. For currently available expansion units,
refer to the following product guides:
Lenovo Storage D1212 and D1224 Drive Enclosures
http://lenovopress.com/lp0512
Lenovo Storage D3284 External High Density Drive Expansion Enclosure
http://lenovopress.com/lp0513
The following table lists the models of the E1012 and E1024 expansion
enclosures.
Table 2. Part numbers for ordering E1012 and E1024 models
Description | Part number |
---|
LFF models
Lenovo Storage E1012 LFF Disk Expansion Single SAS 10 Module, Rail Kit, 9×5
NBD| 64111 B1
Lenovo Storage E1012 LFF Disk Expansion Dual SAS 10 Module, Rail Kit, 9×5 NBD|
64111B2
SFF models
Lenovo Storage E1024 SFF Disk Expansion Single SAS 10 Module, Rail Kit, 9×5
NBD| 64111B3
Lenovo Storage E1024 SFF Disk Expansion Dual SAS 10 Module, Rail Kit, 9×5 NBD|
64111B4
The part number for the E1012 or E1024 includes the following items:
- One E1012 or E1024 chassis with two power supplies with fans and with one or two SAS I/O expansion modules installed
- Two 4.3m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cables
- Lenovo Storage SAN Rack Mount Kit – Rails 25″-36″
- Getting Started Guide
- Warranty Flyer
- Important Notices Flyer
- Documentation Flyer
Connectivity topology
The E1012 and E1024 support single and dual expansion module configurations.
Standard models of the E1012 and E1024 ship with one or two expansion modules
(see Table 2). Single module configurations can be upgraded to dual module
configurations non-disruptively.
Each expansion module has two 6 Gb SAS x4 ports (Mini-SAS SFF-8088 connectors)
labeled IN and OUT.
These ports are used for connections to a supported RAID adapter installed in
a server and for daisy chaining the E1012 and E1024 enclosures between each
other. The external port on the RAID controller is connected to the IN port on
the expansion module, the OUT port on the expansion module is connected to the
IN port on the expansion module in the adjacent enclosure, and so on.
Single I/O module configurations can be used with a supported RAID adapter or
HBA. In this topology, each port on the adapter is connected to a separate
chain of single I/O expansion enclosures, as illustrated in the following
figure.
Figure 5. Single I/O module connectivity topology
Dual I/O module configurations can be used with 2-port RAID adapters for high
availability and performance.
In this topology, each port on the RAID adapter is connected to a different
I/O module chain within the same chain of dual I/O enclosures.
Dual I/O connectivity topology without enclosure redundancy is shown in the
following figure.
Figure 6. Dual I/O connectivity topology without enclosure redundancy
Dual I/O connectivity topology with enclosure redundancy is shown in the
following figure.
Figure 7. Dual I/O connectivity topology with enclosure redundancy
The following table lists the maximum number of the E1012 and E1024 in a chain
on the same adapter.
Table 3. Maximum number of the E1012 and E1024 in a chain on the same adapter
Single I/O chain | E1012 qty | 0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
---|---|---|---|---|---|---|---|---|---|---|
E1024 qty | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 | |
Dual I/O chain | E1012 qty | 0 | 1 | 2 | 3 | 4 | ||||
E1024 qty | 4 | 3 | 2 | 1 | 0 |
The following table lists ordering information for the expansion modules and
related connectivity options.
Table 4. Expansion modules and connectivity options
Desc ription
| Pa rt number| Fea ture code|
Ma x qty per enclosure
---|---|---|---
Expansion modules
Lenovo Storage Expansion SAS IO Module| 00WC085| AT27| 2
Connectivity cables – Mini-SAS Host Adapter to Expansion and Expansion to
Expansion
External MiniSAS 8088/MiniSAS 8088 0.6m cable| 00WE754| AT1A| 2
External MiniSAS 8088/MiniSAS 8088 1m cable| 00WE755| AT1B| 2
External MiniSAS 8088/MiniSAS 8088 2m cable| 00WE756| AT1C| 2
Connectivity cables – Mini-SAS HD Host Adapter to Expansion
1.5m HD-miniSAS to miniSAS SAS Cable| 00D5224| A3HX| 2
3m HD-miniSAS to miniSAS SAS Cable| 00D5226| A3HY| 2*
- One cable per SAS expansion module.
Drives
The E1012 enclosure supports up to 12 LFF hot-swap drives, and the E1024
enclosure supports up to 24 SFF hot-swap drives.
The following tables list drive options for the E1012 and E1024 drive
enclosures.
Table 5. LFF drive options
Desc ription
| Pa rt number| Fea ture code|
Max imum qty per one E1012
---|---|---|---
3.5-inch SAS hot-swap HDDs
Lenovo Storage 3.5″ 600GB 10K SAS HDD (2.5″ in 3.5″)| 00WC040| AT21| 12
Lenovo Storage 3.5″ 900GB 10K SAS HDD (2.5″ in 3.5″)| 00WC035| AT1Z| 12
3.5-inch NL SAS hot-swap HDDs
Lenovo Storage 3.5″ 2TB 7.2k NL-SAS HDD| 00MM735| AT1V| 12
Lenovo Storage 3.5″ 4TB 7.2k NL-SAS HDD| 00MM730| AT1W| 12
Lenovo Storage 3.5″ 6TB 7.2k NL-SAS HDD| 00MM725| AT1Y| 12
Lenovo Storage 3.5″ 8TB 7.2k NL-SAS HDD| 00WE790| AT47| 12
Lenovo Storage 3.5″ 10TB 7.2k NL-SAS HDD| 01DC631| AU7W| 12
3.5-inch NL SAS hot-swap SEDs
Lenovo Storage 3.5″ 4TB 7.2k NL-SAS HDD (SED)| 00WC025| AT1X| 12
3.5-inch SAS hot-swap SSDs (10 DWD)
Lenovo Storage 3.5″ 400GB SSD SAS (2.5″ in 3.5″ SSD1600MM)| 00WC030| AT20| 12
Lenovo Storage 3.5″ 400GB 10DWD SAS SSD (2.5″ in 3.5″ 1200.2)| 4XB7A09596|
B16B| 12
Table 6. SFF drive options
Desc ription
| Pa rt number| Fea ture code|
Max imum qty per one E1024
---|---|---|---
2.5-inch SAS hot-swap HDDs
Lenovo Storage 2.5″ 300GB 15k SAS HDD| 00MM685| AT1H| 24
Lenovo Storage 2.5″ 600GB 10k SAS HDD| 00MM700| AT1K| 24
Lenovo Storage 2.5″ 600GB 15k SAS HDD| 00MM680| AT1J| 24
Lenovo Storage 2.5″ 900GB 10k SAS HDD| 00MM695| AT1M| 24
Lenovo Storage 2.5″ 1.2TB 10k SAS HDD| 00MM690| AT1P| 24
Lenovo Storage 2.5″ 1.8TB 10k SAS HDD| 00YG718| ATSK| 24
2.5-inch SAS hot-swap SEDs
Lenovo Storage 2.5″ 600GB 10k SAS HDD (SED)| 00WC020| AT1L| 24
Lenovo Storage 2.5″ 900GB 10k SAS HDD (SED)| 00MM745| AT1N| 24
Lenovo Storage 2.5″ 1.2TB 10k SAS HDD (SED)| 00MM740| AT1Q| 24
2.5-inch NL SAS hot-swap HDDs
Lenovo Storage 2.5″ 1TB 7.2k NL-SAS HDD| 00MM705| AT1R| 24
Lenovo Storage 2.5″ 2TB 7.2k NL-SAS HDD| 00YG698| ATSL| 24
2.5-inch SAS hot-swap SSDs (1 DWD) (1200.2)
Lenovo Storage 2.5″ 3.84TB 1DWD SSD| 01CX868| AUJN| 24
Desc ription
| Pa rt number| Fea ture code|
Max imum qty per one E1024
---|---|---|---
2.5-inch SAS hot-swap SSDs (3 DWD) (PM1635)
Lenovo Storage 2.5″ 400GB 3DWD SSD| 00YH988| AU22| 24
Lenovo Storage 2.5″ 800GB 3DWD SSD| 00YH978| AU21| 24
Lenovo Storage 2.5″ 1.6TB 3DWD SSD| 00YH968| AU20| 24
2.5-inch SAS hot-swap SSDs (10 DWD) (SSD1600MM)
Lenovo Storage 2.5″ 400GB SSD (SAS)| 00MM720| AT1S| 24
Lenovo Storage 2.5″ 800GB SSD (SAS)| 00MM715| AT1T| 24
Lenovo Storage 2.5″ 1.6TB SSD (SAS)| 00MM710| AT1U| 24
2.5-inch SAS hot-swap SSDs (10 DWD) (1200.2)
Lenovo Storage 2.5″ 400GB 10DWDSAS SSD (1200.2)| 01CX697| B16A| 24
Lenovo Storage 2.5″ 800GB 10DWD SAS SSD (1200.2)| 01CX687| B168| 24
Lenovo Storage 2.5″ 1.6TB 10DWD SAS SSD (1200.2)| 01CX682| B167| 24
2.5-inch SAS hot-swap SED SSDs (10 DWD)
Lenovo Storage 2.5” 400GB 10DWD SED SSD (SSD1600MM)| 00YH983| AU24| 24
Lenovo Storage 2.5″ 800GB 10DWD SED SSD (SSD1600MM)| 00YH973| AU23| 24
Lenovo Storage 2.5″ 800GB 10DWD SED (FIPS) SSD (1200.2)| 01CX692| B169| 24
Powe r cables
The E1012 and E1024 ship standard with two 4.3m, 10A/100-250V, C13 to IEC
320-C14 Rack Power Cables. Other power cable options are also available, and
the part numbers and feature codes to order the power cables (two power cables
are required per each E1012 and E1024) are listed in the following table.
Table 7. Part numbers and feature codes for ordering power cables
Desc ription
| Pa rt number|
Fea ture code
---|---|---
Rack power cables
1.2m, 10A/100-250V, 2 Short C13s to Short C14 Rack Power Cable| 47C2487| A3SS
1.2m, 16A/100-250V, 2 Short C13s to Short C20 Rack Power Cable| 47C2491| A3SW
1.5m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable| 39Y7937| 6201
2.5m, 10A/100-250V, 2 Long C13s to Short C14 Rack Power Cable| 47C2488| A3ST
2.5m, 16A/100-250V, 2 Long C13s to Short C20 Rack Power Cable| 47C2492| A3SX
2.8m, 10A/100-250V, 2 Short C13s to Long C14 Rack Power Cable| 47C2489| A3SU
2.8m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable| None*| 6311
2.8m, 10A/100-250V, C13 to IEC 320-C20 Rack Power Cable| 39Y7938| 6204
2.8m, 16A/100-250V, 2 Short C13s to Long C20 Rack Power Cable| 47C2493| A3SY
4.1m, 10A/100-250V, 2 Long C13s to Long C14 Rack Power Cable| 47C2490| A3SV
4.1m, 16A/100-250V, 2 Long C13s to Long C20 Rack Power Cable| 47C2494| A3SZ
4.3m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable| 39Y7932| 6263
Line cords
10A/125V C13 to NEMA 5-15P 4.3m line cord| 39Y7931| 6207
10A/250V C13 to NEMA 6-15P 2.8m line cord| 46M2592| A1RF
Argentina 10A/250V C13 to IRAM 2073 2.8m line cord| 39Y7930| 6222
Desc ription| Pa rt number| Fea ture code
---|---|---
Australia/NZ 10A/250V C13 to AS/NZ 3112 2.8m line cord| 39Y7924| 6211
Brazil 10A/250V C13 to NBR 14136 2.8m line cord| 69Y1988| 6532
China 10A/250V C13 to GB 2099.1 2.8m line cord| 39Y7928| 6210
Denmark 10A/250V C13 to DK2-5a 2.8m line cord| 39Y7918| 6213
European 10A/230V C13 to CEE7-VII 2.8m line cord| 39Y7917| 6212
India 10A/250V C13 to IS 6538 2.8m line cord| 39Y7927| 6269
Israel 10A/250V C13 to SI 32 2.8m line cord| 39Y7920| 6218
Italy 10A/250V C13 to CEI 23-16 2.8m line cord| 39Y7921| 6217
Japan 12A/125V C13 to JIS C-8303 2.8m line cord| 46M2593| A1RE
Korea 12A/250V C13 to KETI 2.8m line cord| 39Y7925| 6219
South Africa 10A/250V C13 to SABS 164 2.8m line cord| 39Y7922| 6214
Switzerland 10A/250V C13 to SEV 1011-S24507 2.8m line cord| 39Y7919| 6216
Taiwan 15A/125V C13/CNS 10917 2.8m line cord| 00CG267| 6402
United Kingdom 10A/250V C13 to BS 1363/A 2.8m line cord| 39Y7923| 6215
Physical specifications
The E1012 and E1024 have the following dimensions and weights (approximate):
-
E1012
Height: 87 mm (3.4 in.)
Width: 447 mm (17.6 in.)
Depth: 523 mm (20.6 in.) -
E1024
Height: 89 mm (3.5 in.)
Width: 447 mm (17.6 in.)
Depth: 519 mm (20.5 in.) -
Weight
E1012: Minimum: 16.8 kg (37.0 lb); Maximum: 26.6 kg (58.6 lb)
E1024: Minimum: 16.9 kg (37.2 lb); Maximum: 23.4 kg (51.6 lb)
Operating environment
The E1012 and E1024 are supported in the following environment:
-
Air temperature:
Operating: 5 °C to 40 °C (41 °F to 104 °F); decrease the maximum ambient temperature by 3.3
°C for every 1,000 m (3,280 ft)
Storage: -10 °C to +60 °C (14 °F to 140 °F)
Maximum altitude: 3,000 m (9,842 ft) -
Humidity:
Operating: 8% to 85% (non-condensing)
Storage: 5% to 90% (non-condensing) -
Electrical:
100 to 240 (nominal) V AC; 50 Hz to 60 Hz
BTU output: 1488 Btu/hr (436 W)
Noise level: 6.8 bels
Warranty
Lenovo Storage E1012 and E1024 Disk Expansion Enclosures (withdrawn product)
The E1012 and E1024 have a three-year parts-only warranty with 9×5/next
business day (NBD) terms.
Lenovo offers service upgrades through warranty maintenance upgrades and post-
warranty maintenance agreements with a well-defined scope of services,
including service hours, response time, term of service, and service agreement
terms and conditions.
Lenovo warranty service upgrade offerings are region-specific. Not all
warranty service upgrades are available in every region. For more information
about Lenovo warranty service upgrade offerings that are available in your
region, go to the Lenovo Data Center Solution Configurator (DCSC):
http://dcsc.lenovo.com
The following table explains warranty service definitions for the E1012 and
E1024 enclosures.
Table 8. Warranty service definitions
Term | Description |
---|---|
On-site service | A service technician will arrive at the client’s location for |
equipment service.
24x7x4 hour| A service technician is scheduled to arrive at the client
location within four hours after remote problem determination is completed.
Lenovo provides service around the clock, every day, including the Lenovo
holidays.
9x5x4 hour| A service technician is scheduled to arrive at the client location
within four business hours after remote problem determination is completed.
Lenovo provides service 8:00 am – 5:00 pm in the client’s local time zone,
Monday-Friday, excluding Lenovo holidays. For example, if a customer reports
an incident at 3:00 pm on Friday, the technician will arrive by 10:00 am the
following Monday.
9×5 next business day| A service technician is scheduled to arrive at the
client location on the business day after remote problem determination is
completed. Lenovo provides service 8:00 am – 5:00 pm in the client’s local
time zone, Monday – Friday, excluding Lenovo holidays. Calls received after
4:00 pm local time require an extra business day for service dispatch. Next
business day service is not guaranteed.
In general, the types of Lenovo warranty service upgrades for the E1012 and E1024 are as follows:
-
Warranty and maintenance service upgrades:
Onsite support for 9×5 NBD coverage
4-hour target response time with onsite, 9×5 or 24×7 service coverage
Up to five years of warranty extension for all service levels in one or two- year increments -
Hard Drive Retention
Lenovo’s Hard Drive Retention service is a multi-drive hard drive retention offering that ensures your data is always under your control, regardless of the number of hard drives that are installed in your Lenovo system. In the unlikely event of a hard drive failure, you retain possession of your hard drive while Lenovo replaces the failed drive part. Your data stays safely on your premises, in your hands.
The Hard Drive Retention service can be purchased in convenient bundles with our warranty upgrades and extensions.
Regulatory compliance
The E1012 and E1024 conform to the following regulations:
- UL 60950-1, 2nd Edition, 2007-03-27 (USA)
- CAN/CSA-C22.2 No 60950-1-07, 2nd Edition, 2007-03 (Canada)
- IEC 60950-1:2005 (2nd Edition); Am 1:2009
- EN 60950-1:2005, 2nd Edition, AM1 2009 (EU)
- CFR 47 Part 15 Subpart B Class A (USA FCC)
- ICES-003:2012, Class A (Canada)
- EN 55022: 2010 Class A (EU)
- EN 55024: 2010 (EU)
- ASNZS CISPR 22-2009 Class A
- CNS 14338 (2006)
- KN22 Class A
- VCCI Technical Requirements 2012 Class A
- RoHS Directive 2011/65/EU
- EACH
- NOM
- UL, BMSI, CCC
RAID controllers and HBAs
The E1012 and E1024 expansion enclosures are supported with the RAID adapters
and HBAs that are listed in the following table.
Table 9. RAID controllers and HBAs
Desc ription| Pa rt number| Ma x qty of enclosures
per adapter
---|---|---
S ingle I/O modu le| Dua l I/O modu le
System x HBAs (non-RAID)
6Gb SAS HBA| 46M0907| 8| No support
System x RAID adapters
ServeRAID M5225-2GB SAS/SATA Controller| 00AE938| 8| 4
ServeRAID M5120 SAS/SATA Controller| 81Y4478| 8| 4
ThinkServer RAID adapters
ThinkServer 9286CV-8e 6Gb 8-port External SAS RAID Adapter by LSI| 4XB0F28699|
8| 4
ThinkServer 9286CV-8e 6Gb SAS RAID Adapter by LSI| 4XB0F28646| 8| 4
ThinkServer 9280-8e 6Gb 8-port RAID Adapter by LSI| 4XB0F28645| 8| 4
The following table summarizes the features of supported RAID adapters.
Table 10. RAID adapter features and specifications summary (PN = Part number)
Fea ture
| M5225 -2GB| M512 0| 9286CV -8e|
9280 -8e
---|---|---|---|---
Part number| 00AE938| 81Y4478| 4XB0F28646
4XB0F28699| 4XB0F28645
Form factor| Low profile| Low profile| Low profile| Low profile
Controller chip| LSI SAS3108| LSI SAS2208| LSI SAS2208| LSI SAS2108
Host interface| PCIe 3.0 x8| PCIe 3.0 x8| PCIe 3.0 x8| PCIe 2.0 x8
Port interface| 12 Gbps SAS| 6 Gbps SAS| 6 Gbps SAS| 6 Gbps SAS
Number of external ports| 8| 8| 8| 8
External port connectors| 2x Mini-SAS HD (SFF-8644)| 2x Mini-SAS (SFF-8088)|
2x Mini-SAS (SFF-8088)| 2x Mini-SAS (SFF-8088)
Drive interface| SAS| SAS| SAS| SAS
Drive type| HDD, SED, SSD| HDD, SED, SSD| HDD, SED, SSD| HDD, SED, SSD
Max number of devices| 240| 240| 240| 240
RAID levels| 0/1/10/5/50; Optional 6/60 (PN 47C8706)| 0/1/10/5/50; Optional
6/60 (PN 81Y4546)| 0/1/10/5/50/6/60| 0/1/10/5/50/6/60
JBOD mode| No| No| No| No
Cache| 2 GB (included)| 512 MB (PNs 81Y4484, 81Y4487) 1 GB (PN 81Y4559) 2 GB
(PN 47C8670)| 1 GB (included)| 512 MB (included)
Cache protection| Flash (included)| Battery (optional for 81Y4484; PN 81Y4508)
Flash (included with 81Y4487, 81Y4559, 47C8670)| Flash (included)| Battery
(optional; PN 67Y2647)
SSD Caching| Optional
(PN 47C8712)
| Optional (PN 90Y4318)| Optional
(PN 4XB0F28702)
| No
The 6Gb SAS HBA (part number 46M0907) has the following features and specifications:
- Form factor: Low profile
- Controller chip: LSI SAS2008
- Host interface: PCIe 2.0 x8
- Port interface: 6 Gbps SAS/3 Gbps SATA
- Number of ports: 8 (four external, four internal)
- Port connectors: 1x Mini-SAS x4 (SFF-8088), 4x SATA (internal)
- Drive interface: SAS
- Drive type: HDD, SSD
- Maximum number of devices: 512
- RAID levels: None, JBOD mode only
- Cache: None
Servers
The E1012 and E1024 expansion enclosures are supported with the following
Lenovo servers:
- System x3100 M5 Type 5457
- System x3250 M5 Type 5458
- System x3300 M4 Type 7382
- System x3500 M4 Type 7383 (E5-2600 and E5-2600 v2)
- System x3500 M5 Type 5464
- System x3530 M4 Type 7160 (E5-2400 and E5-2400 v2)
- System x3550 M4 Type 7914 (E5-2600 and E5-2600 v2)
- System x3550 M5 Type 5463
- System x3550 M5 Type 8869
- System x3630 M4 Type 7158 (E5-2400 and E5-2400 v2)
- System x3650 M4 Type 7915 (E5-2600 and E5-2600 v2)
- System x3650 M4 BD Type 5466
- System x3650 M4 HD Type 5460
- System x3650 M5 Type 5462
- System x3650 M5 Type 8871
- System x3750 M4 Type 8753
- System x3850 X6 Type 6241 (E7 v2 and E7 v3)
- System x3950 X6 Type 6241 (E7 v2 and E7 v3)
- ThinkServer RS140
- ThinkServer RD350 (E5-2600 v3 and E5-2600 v4)
- ThinkServer RD450 (E5-2600 v3 and E5-2600 v4)
- ThinkServer RD550 (E5-2600 v3 and E5-2600 v4)
- ThinkServer RD650 (E5-2600 v3 and E5-2600 v4)
- ThinkServer TS440
- ThinkServer TS450
- ThinkServer TD350 (E5-2600 v3 and E5-2600 v4)
- For RAID adapters and HBAs support details for a particular server, refer to a Lenovo Press product guide for the server, found at: http://lenovopress.com
Rack cabinets
The following table lists the rack cabinets that are currently offered by Lenovo that can be used for mounting the E1012 and E1024 storage expansion enclosures and other IT infrastructure building blocks.
Desc ription | Pa rt number |
---|---|
25U S2 Standard Rack (1000 mm deep; 2 sidewall compartments) | 93072RX |
25U Static S2 Standard Rack (1000 mm deep; 2 sidewall compartments) | 93072PX |
42U S2 Standard Rack (1000 mm deep; 6 sidewall compartments) | 93074RX |
42U 1100mm Enterprise V2 Dynamic Rack (6 sidewall compartments) | 93634PX |
42U 1100mm Enterprise V2 Dynamic Expansion Rack (6 sidewall compartments) |
93634EX
42U 1200mm Deep Dynamic Rack (6 sidewall compartments)| 93604PX
42U 1200mm Deep Static Rack (6 sidewall compartments)| 93614PX
42U Enterprise Rack (1105 mm deep; 4 sidewall compartments)| 93084PX
42U Enterprise Expansion Rack (1105 mm deep; 4 sidewall compartments)| 93084EX
For more information, see the list of Product Guides in the Rack cabinets category: http://lenovopress.com/servers/options/racks#rt=product-guide
Power distribution units
The following table lists the power distribution units (PDUs) that are currently offered by Lenovo that can be used for distributing electrical power to the E1012 and E1024 storage expansion enclosures and other IT infrastructure building blocks mounted in a rack cabinet.
Desc ription | Pa rt number |
---|
0U Basic PDUs
0U 36 C13/6 C19 24A/200-240V 1 Phase PDU with NEMA L6-30P line cord| 00YJ776
0U 36 C13/6 C19 32A/200-240V 1 Phase PDU with IEC60309 332P6 line cord|
00YJ777
0U 21 C13/12 C19 32A/200-240V/346-415V 3 Phase PDU with IEC60309 532P6 line
cord| 00YJ778
0U 21 C13/12 C19 48A/200-240V 3 Phase PDU with IEC60309 460P9 line cord|
00YJ779
Switched and Monitored PDUs
0U 20 C13/4 C19 Switched and Monitored 24A/200-240V/1Ph PDU w/ NEMA L6-30P
line cord| 00YJ781
0U 20 C13/4 C19 Switched and Monitored 32A/200-240V/1Ph PDU w/ IEC60309 332P6
line cord| 00YJ780
0U 18 C13/6 C19 Switched / Monitored 32A/200-240V/346-415V/3Ph PDU w/ IEC60309
532P6 cord| 00YJ782
0U 12 C13/12 C19 Switched and Monitored 48A/200-240V/3Ph PDU w/ IEC60309 460P9
line cord| 00YJ783
1U 9 C19/3 C13 Switched and Monitored DPI PDU (without line cord)| 46M4002
1U 9 C19/3 C13 Switched and Monitored 60A 3Ph PDU with IEC 309 3P+Gnd cord|
46M4003
1U 12 C13 Switched and Monitored DPI PDU (without line cord)| 46M4004
1U 12 C13 Switched and Monitored 60A 3 Phase PDU with IEC 309 3P+Gnd line
cord| 46M4005
Ultra Density Enterprise PDUs (9x IEC 320 C13 + 3x IEC 320 C19 outlets)
Ultra Density Enterprise C19/C13 PDU Module (without line cord)| 71762NX
Ultra Density Enterprise C19/C13 PDU 60A/208V/3ph with IEC 309 3P+Gnd line
cord| 71763NU
C13 Enterprise PDUs (12x IEC 320 C13 outlets)
DPI C13 Enterprise PDU+ (without line cord)| 39M2816
DPI Single Phase C13 Enterprise PDU (without line cord)| 39Y8941
C19 Enterprise PDUs (6x IEC 320 C19 outlets)
DPI Single Phase C19 Enterprise PDU (without line cord)| 39Y8948
DPI 60A 3 Phase C19 Enterprise PDU with IEC 309 3P+G (208 V) fixed line cord|
39Y8923
Front-end PDUs (3x IEC 320 C19 outlets)
DPI 30amp/125V Front-end PDU with NEMA L5-30P line cord| 39Y8938
DPI 30amp/250V Front-end PDU with NEMA L6-30P line cord| 39Y8939
DPI 32amp/250V Front-end PDU with IEC 309 2P+Gnd line cord| 39Y8934
DPI 60amp/250V Front-end PDU with IEC 309 2P+Gnd line cord| 39Y8940
DPI 63amp/250V Front-end PDU with IEC 309 2P+Gnd line cord| 39Y8935
Universal PDUs (7x IEC 320 C13 outlets)
DPI Universal 7 C13 PDU (with 2 m IEC 320-C19 to C20 rack power cord)| 00YE443
NEMA PDUs (6x NEMA 5-15R outlets)
DPI 100-127V PDU with fixed NEMA L5-15P line cord| 39Y8905
Line cords for PDUs that ship without a line cord
DPI 30a Line Cord (NEMA L6-30P)| 40K9614
Desc ription| Pa rt number
---|---
DPI 32a Line Cord (IEC 309 P+N+G)| 40K9612
DPI 32a Line Cord (IEC 309 3P+N+G)| 40K9611
DPI 60a Cord (IEC 309 2P+G)| 40K9615
DPI 63a Cord (IEC 309 P+N+G)| 40K9613
DPI Australian/NZ 3112 Line Cord (32A)| 40K9617
DPI Korean 8305 Line Cord (30A)| 40K9618
Uninterruptible power supply units
The following table lists the uninterruptible power supply (UPS) units that
are currently offered by Lenovo that can be used for providing electrical
power protection to the E1012 and E1024 storage expansion enclosures and
other IT infrastructure building blocks.
Desc ription | Pa rt number |
---|
Worldwide models
RT1.5kVA 2U Rack or Tower UPS (100-125VAC) (8x NEMA 5-15R 12A outlets)|
55941AX
RT1.5kVA 2U Rack or Tower UPS (200-240VAC) (8x IEC 320 C13 10A outlets)|
55941KX
RT2.2kVA 2U Rack or Tower UPS (100-125VAC) (8x NEMA 5-20R 16A outlets)|
55942AX
RT2.2kVA 2U Rack or Tower UPS (200-240VAC) (8x IEC 320 C13 10A, 1x IEC 320 C19
16A outlets)| 55942KX
RT3kVA 2U Rack or Tower UPS (100-125VAC) (6x NEMA 5-20R 16A, 1x NEMA L5-30R
24A outlets)| 55943AX
RT3kVA 2U Rack or Tower UPS (200-240VAC) (8x IEC 320 C13 10A, 1x IEC 320 C19
16A outlets)| 55943KX
RT5kVA 3U Rack or Tower UPS (200-240VAC) (8x IEC 320 C13 10A, 2x IEC 320 C19
16A outlets)| 55945KX
RT6kVA 3U Rack or Tower UPS (200-240VAC) (8x IEC 320 C13 10A, 2x IEC 320 C19
16A outlets)| 55946KX
RT8kVA 6U Rack or Tower UPS (200-240VAC) (4x IEC 320-C19 16A outlets)| 55948KX
RT11kVA 6U Rack or Tower UPS (200-240VAC) (4x IEC 320-C19 16A outlets)|
55949KX
RT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) (4x IEC 320-C19 16A
outlets)| 55948PX
RT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) (4x IEC 320-C19 16A
outlets)| 55949PX
ASEAN, HTK, INDIA, and PRC models
ThinkSystem RT3kVA 2U Standard UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19
16A outlets)| 55943KT
ThinkSystem RT3kVA 2U Long Backup UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x
C19 16A outlets)| 55943LT
ThinkSystem RT6kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block
output)| 55946KT
ThinkSystem RT10kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block
output)| 5594XKT
Lenovo Financial Services
Lenovo Financial Services reinforces Lenovo’s commitment to delivering
pioneering products and services that are recognized for their quality,
excellence, and trustworthiness. Lenovo Financial Services offers financing
solutions and services that complement your technology solution anywhere in
the world.
We are dedicated to delivering a positive finance experience for customers
like you who want to maximize your purchase power by obtaining the technology
you need today, protecting against technology obsolescence, and preserving
your capital for other uses.
We work with businesses, non-profit organizations, governments, and
educational institutions to finance their entire technology solution. We focus
on making it easy to do business with us. Our highly experienced team of
finance professionals operates in a work culture that emphasizes the
importance of providing outstanding customer service. Our systems, processes,
and flexible policies support our goal of providing customers with a positive
experience.
We finance your entire solution. Unlike others, we allow you to bundle
everything you need from hardware and software to service contracts,
installation costs, training fees, and sales tax. If you decide weeks or
months later to add to your solution, we can consolidate everything into a
single invoice.
Our Premier Client services provide large accounts with special handling
services to ensure these complex transactions are serviced properly. As a
premier client, you have a dedicated finance specialist who manages your
account through its life, from the first invoice through asset return or
purchase. This specialist develops an in-depth understanding of your invoice
and payment requirements. For you, this dedication provides a high-quality,
easy, and positive financing experience.
For your region-specific offers please ask your Lenovo sales representative or
your technology provider about the use of Lenovo Financial Services. For more
information, see the following Lenovo website:
http://www.lenovo.com/us/en/landingpage/lenovo-financial-services
Related publications and links
For more information, see the following documents:
Lenovo Storage product page
http://www.lenovo.com/systems/storage
Lenovo Data Center Solution Configurator (DCSC):
http://dcsc.lenovo.com
Lenovo Storage E1012 Support
http://datacentersupport.lenovo.com/us/en/products/storage/lenovo-
storage/e1012/6411
Lenovo Storage E1024 Support
http://datacentersupport.lenovo.com/us/en/products/storage/lenovo-
storage/e1024/6411
Related product families
Product families related to this document are the following:
Notices
Lenovo may not offer the products, services, or features discussed in this
document in all countries. Consult your local Lenovo representative for
information on the products and services currently available in your area.
Any reference to a Lenovo product, program, or service is not intended to
state or imply that only the Lenovo product, program, or service may be used.
Any functionally equivalent product, program, or service that does not
infringe any Lenovo intellectual property right may be used instead. However,
it is the user’s responsibility to evaluate and verify the operation of any
other product, program, or service. Lenovo may have patents or pending patent
applications covering subject matter described in this document. The
furnishing of this document does not give you any license to these patents.
You can send license inquiries, in writing, to:
Lenovo (United States), Inc.
8001 Development Drive
Morrisville, NC 27560
U.S.A.
Attention: Lenovo Director of Licensing
LENOVO PROVIDES THIS PUBLICATION ”AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER
EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR A PARTICULAR PURPOSE. Some
jurisdictions do not allow disclaimers of express or implied warranties in
certain transactions, therefore, this statement may not apply to you.
This information could include technical inaccuracies or typographical errors.
Changes are periodically made to the information herein; these changes will be
incorporated in new editions of the publication. Lenovo may make improvements
and/or changes in the product(s) and/or the program(s) described in this
publication at any time without notice.
The products described in this document are not intended for use in
implantation or other life support applications where malfunction may result
in injury or death to persons. The information contained in this document
does not affect or change Lenovo product specifications or warranties. Nothing
in this document shall operate as an express or implied license or indemnity
under the intellectual property rights of Lenovo or third parties. All
information contained in this document was obtained in specific environments
and is presented as an illustration. The result obtained in other operating
environments may vary. Lenovo may use or distribute any of the information you
supply in any way it believes appropriate without incurring any obligation to
you.
Any references in this publication to non-Lenovo Web sites are provided for
convenience only and do not in any manner serve as an endorsement of those Web
sites. The materials at those Web sites are not part of the materials for this
Lenovo product, and use of those Web sites is at your own risk. Any
performance data contained herein was determined in a controlled environment.
Therefore, the result obtained in other operating environments may vary
significantly. Some measurements may have been made on development-level
systems and there is no guarantee that these measurements will be the same on
generally available systems. Furthermore, some measurements may have been
estimated through extrapolation. Actual results may vary. Users of this
document should verify the applicable data for their specific environment.
© Copyright Lenovo 2022. All rights reserved.
This document, LP0043, was created or updated on May 22, 2019.
Send us your comments in one of the following ways:
Use the online Contact us review form found at:
https://lenovopress.lenovo.com/LP0043
Send your comments in an e-mail to:
comments@lenovopress.com
This document is available online at https://lenovopress.lenovo.com/LP0043.
Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo
in the United States, other countries, or both. A current list of Lenovo
trademarks is available on the Web at
https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other
countries, or both:
Lenovo®
ServeRAID
System x®
ThinkServer®
ThinkSystem
The following terms are trademarks of other companies:
Linux® is the trademark of Linus Torvalds in the U.S. and other countries.
Microsoft®, Windows Server®, and Windows® are trademarks of Microsoft
Corporation in the United States, other countries, or both.
Other company, product, or service names may be trademarks or service marks of
others.
Lenovo Storage E1012 and E1024 Disk Expansion Enclosures (withdrawn product)
References
- storage :: lenovo storage :: e1012 :: 6411 Lenovo Data Center Support - Lenovo Support US
- storage :: lenovo storage :: e1024 :: 6411 Lenovo Data Center Support - Lenovo Support US
- DCSC - Data Center Solution Configurator
- Lenovo Press
- Lenovo Storage D1212 and D1224 Drive Enclosures Product Guide > Lenovo Press
- Lenovo Storage D3284 External High Density Drive Expansion Enclosure Product Guide > Lenovo Press
- Rack Cabinets > Lenovo Press
- Uninterruptible Power Supplies > Lenovo Press
- storage :: lenovo storage Lenovo Data Center Support - Lenovo Support US
- Enterprise Storage Server Solutions for Your Data Center | Lenovo US
- Lenovo Financial Services | Lenovo US
- Lenovo Storage E1012 and E1024 Disk Expansion Enclosures Product Guide (withdrawn product) > Lenovo Press
- Direct-Attached Storage > Lenovo Press
- Copyright and Trademark Information | Lenovo US | Lenovo US
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>