Husqvarna A 1000 A Line Air Scrubber Owner’s Manual
- June 17, 2024
- Husqvarna
Table of Contents
Husqvarna A 1000 A Line Air Scrubber Owner’s Manual
Introduction
Notice!
These instructions are only for the air scrubber type Husqvarna A 1000 / A 2000.
The air scrubber, Husqvarna A 1000 / A 2000 can only be used with dry, non- explosive materials.
Husqvarna not be held responsible if the air scrubber is used for other applications or has been used in ways other than those outlined in this instruction manual.
Before using the machine, please read the safety regulations carefully.
Read the complete instruction manual before using the Husqvarna A 1000 / A 2000.
All spare parts used for the Husqvarna A 1000 / A 2000 must those specified by Husqvarna Construction Products.
Type plate
230V~ | 2A |
---|---|
280W | 50Hz |
1000 m³/h | 20KG |
50Hz
230V~| 4A
---|---
750W| 50Hz
2000 m³/h| 38KG
P/N: 967672201
HUSQVARNA AB SE-561 82 HUSKVARNA SWEDEN
MADE IN CHINA
HUSQVARNA AB SE-561 82 HUSKVARNA SWEDEN
MADE IN CHINA
Unpacking
When unpacking the machine, please check that the air scrubber has not been damaged in transport.
Product overview
Safety Instructions
Handling
Warning
- Make sure that you read and understand the instructions for the main product to ensure that you know what personal equipment to wear, what safety equipment to use and how to work in a safe mode.
Warning
- Cables damaged through crushing or splitting can be dangerous if used and should be replaced immediately. Risk of personal injury
Warning
- Do not connect the machine to an unearthed socket. Risk of personal injury.
Warning
- Make sure the assembly area is firm, so the air scrubber does not tip over. Risk of personal and material injury.
Warning
- Risk of pinching when handling the toggle fastener.
Warning
- The machine must not be used in environments where explosive gases may be present. Serious risk of explosion
Warning
- The machine should be turned off at the switch before releasing the power lead from the wall outlet. If the switch is in the on position, a spark can occur between the contact on the power lead contact.
Service
Warning
- Remove the plug from the wall socket when carrying out maintenance work. Risk of personal injury.
Warning
- Dust that is hazardous to health can be spread when the coarse filter and the absolute filter are replaced. Accordingly, the user should wear protective glasses, protective gloves, and a breathing mask conforming to protection class FFp2
Warning
- Do not puncture the absolute filer. Risk of dust dispersion
Function
Connect the lead to the power outlet, attach the outlet hose if available. Start the machine by pressing the start knob. The air scrubber has two speeds.
The air scrubber separates material in two stages:
The first stage uses a coarse filter. This traps the bigger particles and acts as protection for the main filter. The coarse filter should be changed on a daily basis.
The second absolute filter separates the unhealthy dust that is invisible to the eye.
Coarse filter characteristics
The coarse filter is strong and easy to change. It has low pressure drop and good separation capability.
The coarse filter takes care of big particles and acts as protection for the absolute filter.
Main filter characteristics
The main filter is an absolute filter with class HEPA H13 that is dimension ed for fine, dry dust and should be preceded by a pre-filter.
Caution
- The operating life of the absolute filter decreases and can be completely destroyed if exposed to water.
Caution
- The absolute filters cannot be cleaned and must be replaced when full.
Filter indicator
A 1000 / A 2000 has two filter indicators connected to a warning light which measures the pressure drop over the filter. If the pressure drop is too high, a yellow lamp light up, indicating that the prefilter should be changed. When the Yellow light stays on even after a pre-filter change. It is time to Change the HEPA filter. Using the air scrubber when light is showing will reduce the effectiveness of the machine. When the pressure drop is too low, a red lamp will light up, indicating that the Hepa filter is leaking/damaged and needs to be replaced immediately.
Please note that the filter indicators only does work at full speed.
Recommended intervals for filter change: Socks filter every 6 months and Hepa filter every 12 month.
Fan
The air scrubber is equipped with a single, 1 phase fan
Risk of dust dispersion – Use of personal safety equipment Unhealthy dust can be spread when cleaning the coarse filter and during filter change.Accordingly, the user should wear protective glasses, protective gloves, and a breathing mask conforming to protection class FFP2.
Accessories
PART NO. | DESCRIPTION | No./machine | Machine |
---|---|---|---|
PART NO. | Pre-filter 20-pcs | 1 ea | A 1000 |
590460801 | HEPA filter | 1 ea | A 1000 |
590430002 | Pre-filter 20-pcs | 1 ea | A 1000 |
590463201 | HEPA filter | 1 ea | A 1000 |
Warranty
All Parnassus devices and accessories have a 12-month factory warranty from the date of purchase for material and manufacturing defects. Do not attempt to repair the suction apparatus without the consent of the manufacturer.
The warranty does not cover defects which are the result of normal wear and tear, negligence, defective use, unauthorized repair or the suction apparatus being connected to the incorrect voltage. In the event of any complaint, the suction apparatus or an agreed part of it must be returned to us or our authorised representative for warranty examination and for any warranty repair or replacement.
PROBLEM SOLVING
The A 1000 / A 2000 is designed and manufactured for severe environments and tasks, but the user must note that the machine components must be protected from knocks and blows. Filter and sealing connections are carefully chosen to serve the operator. Therefore, the machine must be handled with care if it is to work correctly for many years.
Problem | Cause | Procedure |
---|---|---|
The fan does not start | No powerCable defective Switch defective | Connect the |
machineChangeChange
The fan stops immediately| Wrong fuse| Connect the correct fuse
The fan runs, but suction is poor| Blocked filter Cover loose Sealing defect|
Change interchangeability current seal
Dust blows from uni| Defective or loose filter| Adjust or change
Keep these instructions!
TECHNICAL DATA
Air scrubber | A 1000 | A 2000 |
---|---|---|
Power | 0,285 kW | 0,75 kW |
Voltage | 230 | 230 V |
Current | /,3 A | 1,2 A |
Power supply | 1-phase | 1-phase |
Airflow | 500/1000 m3/h / 300-600 CFM | 1000/2000 m3/h / 600/1200 CFM |
HEPA FILTER | Filter classification: H 13 | Filter classification: H 13 |
Filter Area | 3,5 m2 / 60 ft2 | 10,5 m2/ 150 ft2 |
Dimension LxWxH | mm: 465x385x466in: 18,3×15,1×18,3 | mm: 724x424x810in: |
28,5×16,7×31,9
Wei ht| 20 kg / 44 lbs| 38 kg / 84 lbs
Original instructions
159181-20
2017-06-02
References
- Wholesale Flooring Tools & Installation Supplies | Kevmor
- Construction products, machines and diamond tools | Husqvarna US
Read User Manual Online (PDF format)