Lenovo ServeRAID M5015 SAS-SATA Controllers User Guide

June 3, 2024
Lenovo

Lenovo ServeRAID M5015 SAS-SATA Controllers

ServeRAID M5015 and M5014 SAS/SATA Controllers

Product Guide (withdrawn product)
The ServeRAID M5015 and ServeRAID M5014 SAS/SATA Controllers for System x are the next-generation 6 Gbps SAS 2.0 RAID controllers. The adapters have two internal mini-SAS connectors to control up to 32 devices and support global and dedicated hot-spare drives. The ServeRAID M5014 controller delivers a full RAID 6 Gbps SAS 2.0 solution, while the ServeRAID M5015 provides additional performance advantages of an extended cache and a standard battery backup unit. With the attachment of the ServeRAID M5000 Advanced Feature Key, the ServeRAID M5015 and M5014 offer the option of RAID 6, RAID 60, and SED Encryption Key management. Figure 1 shows the ServeRAID M5015 with its standard battery backup unit.

Lenovo-ServeRAID-M5015-SAS-SATA-Controllers-FIG-1

ServeRAID M5015 SAS/SATA Controller

Did you know

6 Gbps SAS 2.0 technology has been introduced to address data off-load bottlenecks in the direct-access storage environment. This new throughput doubles the transfer rate of the previous generation. SAS 2.0 is designed for backward compatibility with 3 Gbps SAS as well as with 3 Gbps SATA hard drives. Self-encrypting drives are based on a new technology that helps prevent data from being accessed without authorization. These drives adhere to the Trusted Computing Group (TCG) Enterprise Security Subsystem Class specification and are National Security Agency qualified to provide government-grade encryption. With self-encrypting drives (SEDs), if a drive is removed from its storage system or the server that it is housed in, the data on that drive is encrypted and useless to anyone who attempts to access it without the appropriate security authorization. ServeRAID M5015 and M5014 SAS/SATA Controllers (withdrawn product)

Part number information

Table 1. Ordering part number and feature code

Part number Feature code Description
46M0829 0093 ServeRAID M5015 SAS/SATA Controller
46M0916 3877 ServeRAID M5014 SAS/SATA Controller
46M0917 5744 ServeRAID M5000 Series Battery Kit
68Y7396 5862 ServeRAID M5000 Series Battery Remote Mount Cable
46M0930 5106 ServeRAID M5000 Series Advanced Feature Key
81Y4426 A10C ServeRAID M5000 Series Performance Accelerator Key

The ServeRAID M5015 option part number includes the following items:

  • One ServeRAID M5015 adapter card with full-height bracket
  • One replaceable low-profile (2U) bracket
  • One attached ServeRAID M5000 battery
  • Documentation CD
  • The Important Notices Document

Note: The ServeRAID M5015 option part number 46M0829 includes the M5000 battery, however the feature code 0093 does not contain the battery. Order feature code 5744 if you wish to include the battery in the server configuration. The ServeRAID M5014 option part number includes the following items:

  • One ServeRAID M 5014 adapter card with full-height bracket
  • One replaceable low-profile (2U) bracket
  • The ServeRAID M V1.10 Utility and Documentation CD
  • The Important Notices Document

The ServeRAID M5000 Series Battery Kit option part number contains the following items:

  • ServeRAID M5000 Battery
  • Battery Flyer
  • Quick Install Guide
  • Important Notices Flyer

Tip : The Battery Remote Mount Cable is a separately orderable item and is not part of the Battery Kit. The cable is also part of the System x3650 M3 Hot-swap SAS/SATA 4 Pack HDD Upgrade option, 69Y4236.

Specifications

The ServeRAID M5015 and ServeRAID M5014 adapter cards have the following specifications

  • Eight internal 6 Gbps SAS/SATA ports
  • Two Mini-SAS internal connectors (SFF-8087)
  • 6 Gbps throughput per port
  • 800 MHz PowerPC processor with LSI SAS2108 6 Gbps RAID on Chip (ROC) controller
  • x8 PCI Express 2.0 host interface
  • Onboard data cache (DDR2 running at 800 MHz):
    • ServeRAID M5015: 512 MB
    • ServeRAID M5014: 256 MB
  • Intelligent Li-Ion-based battery backup unit with up to 48 hours of data retention:
    • ServeRAID M5015: Standard in the option part number
    • ServeRAID M5014: Optional
  • Supports RAID levels 0, 1, 5, 10, and 50 (RAID 6 and 60 support with the optional M5000 Advanced Feature Key)
  • Connects to up to 32 SAS or SATA drives
  • SAS and SATA drives are supported, but the mixing of SAS and SATA in the same RAID array is not supported
  • Supports up to 64 logical volumes
  • Supports LUN sizes up to 64 TB
  • Configurable stripe size up to 1 MB
  • Compliant with Disk Data Format (DDF) configuration on disk (COD)
  • S.M.A.R.T. support

Lenovo-ServeRAID-M5015-SAS-SATA-Controllers-FIG-1

Features

The ServeRAID M5015 and ServeRAID M5014 adapter cards have the following featuresC

  • Auto-resume on array rebuild or array reconstruction after loss of system power Auto-resume uses non-volatile NVRAM to save rebuild progress during a host reboot or power failure to automatically resume from the last checkpoint. Auto-resume will ensure data integrity is maintained through the process. The card supports a number of features that are able to be implemented without rebooting the server. Applications such as email and web server benefit from avoiding downtime during transition.
  • Online Capacity Expansion Online Capacity Expansion (OCE) allows the capacity of a virtual disk to be expanded by adding new physical disks or making use of unused space on existing disks, without requiring a reboot.
  • Online RAID Level Migration Online RAID Level Migration (also known as logical drive migration) provides the ability to migrate a virtual disk from any RAID level to any other RAID level without requiring a reboot. System availability and application functionality remain unaffected.
  • Fast initialization for quick array setup
  • Consistency check for background data integrity Consistency Check verifies that all stripes in a virtual disk with a redundant RAID level are consistent. The consistency check will mirror data when an inconsistent stripe is detected for a RAID 1 and recreating the parity from the peer disks when in the case of a RAID 5 or RAID 6. Consistency checks can be scheduled to take place periodically.
  • Extensive online configuration options: advanced monitoring and event notification Management tools provide convenience for configuration of logical volumes plus alerting when errors have occurred or are about to occur.
  • Patrol Read for media scanning and repairing Patrol read is a background sentry service designed to proactively discover and correct media defects (bad sectors) that arise normally as a disk drive ages. The service issues a series of verify commands and if a bad block is discovered, the card’s firmware will use RAID algorithms to recreate the missing data and remap the sector to a good sector. The task is interruptible based on controller activity and host operations. The firmware also provides an interface where the patrol read task can be initiated, set up for continuous operation, and terminated from a management application. Patrol read can be activated by manual command or automatically.
  • Global and dedicated Hot Spare with Revertible Hot Spare support: A hot spare rebuilds data from all virtual disks within the disk group in which it is configured. ServeRAID provides the ability to define a physical disk as a hot spare to replace a failed drive. Hot spares may be configured as either global or dedicated. A global hot spare allows any physical drive to be designated as a hot spare. A dedicated hot spare will allow the user to assign a hot spare drive to a particular array of the same drive type.

The ServeRAID M5000 Series Advanced Feature Key enables the following features:

  • RAID levels 6 and 60
  • LSI SafeStore: support for self-encrypting drive services:
    • Instant secure erase
    • Local key management

LSI SafeStore encryption services offer instant secure erase and local key management for self-encrypting drives. This technology represents a significant step forward in securing data on a disk drive from any unauthorized access or modification resulting from theft, loss, or repurposing of drives:

  • Instant secure erase permanently removes data when repurposing or decommissioning SEDs
  • SafeStore local key management provides the necessary management and protection of SEDs using a simple pass phrase, security key identifier, and security key file that can be set and applied to all SEDs assigned to a ServeRAID adapter. This removes the complexity of managing each SED’s unique encryption key, and essentially relieves the administrator from most of the daily tasks of securing data.

Note : To use the SED services of the ServeRAID M5000 Series Advanced Feature Key, you must use selfencrypting drives as listed in “Supported disk drives” below.

Lenovo-ServeRAID-M5015-SAS-SATA-Controllers-FIG-2The ServeRAID M5000 Series Battery Remote Mount Cable is a 24-inch cable and enables the battery to be installed separately from the adapter. The ServeRAID M5000 Series Performance Accelerator Key adds the following performance and data protection enhancements to the standard ServeRAID products:

  • MegaRAID FastPath : An I/O accelerator that doubles the I/O operations per second (IOPS) on solidstate drives (SSDs)
  • MegaRAID CacheCade : A data-tiering enabler to support hybrid environments of SSDs and HDDs, realizing higher levels of performance
  • MegaRAID Recovery : A data recovery feature that works both in pre-boot and OS environments and provides snapshot capabilities for file-level and volume-level data restoration
  • LSI SafeStore : Utility for enabling encryption and storing drive keys for self-encrypting drives (SEDs)
  • RAID 6 and 60 support : Additional RAID levels for added data protection

The ServeRAID M5000 Series Performance Accelerator Key cannot be installed at the same time as the ServeRAID M5000 Series Advanced Feature Key, 46M0930. The Advanced Feature Key must be removed before the Performance Accelerator Key is installed. The functions of the Advanced Feature Key are provided by the Performance Accelerator Key. No further migration steps are needed

Operating environment

The ServeRAID M5015 and ServeRAID M5014 adapter cards are supported in the following environment:

  • Temperature:
    • At 0-1000 m (0-3000 ft): 10-35° C (50-95° F)
    • At 1000-2100 m (3000-7000 ft): 10-32° C (50-90° F)
  • Relative humidity : 20-80% (non-condensing)

Warranty

One-year limited warranty. When installed on a System x server, these cards assume your system’s base warranty and any warranty upgrade. Batteries are consumables and therefore are not covered under the warranty.

Supported servers
The ServeRAID M5015 and M5014 adapter cards are supported on the System x servers listed in Table 2. Table 2. Supported System x servers (Part 1)

| | | | | | | | | | |
---|---|---|---|---|---|---|---|---|---|---|---
ServeRAID M5015 SAS/SATA Controller| 46M0829| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y
ServeRAID M5014 SAS/SATA Controller| 46M0916| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y
ServeRAID M5000 Series Battery Kit| 46M0917| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y
ServeRAID M5000 Series Battery Remote Mount Cable| 68Y7396| N| N| N| N| Y| Y| Y| Y*| Y| N
ServeRAID M5000 Series Advanced Feature Key| 46M0930| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y
ServeRAID M5000 Series Performance Accelerator Key| 81Y4426| Y| Y| Y| Y| Y| N| N| Y| N| Y

The Remote Mount Cable ships with the System x3650 M3 Hot-swap SAS/SATA 4 Pack HDD Upgrade option, 69Y4236
Table 2. Supported System x servers (Part 2)

| | | | | | | | | | | | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---
ServeRAID M5015 SAS/SATA Controller| 46M0829| Y| Y| N| N| N| N| N| N| Y| N| Y| N
ServeRAID M5014 SAS/SATA Controller| 46M0916| Y| Y| N| N| N| N| N| N| Y| N| Y| N
ServeRAID M5000 Series Battery Kit| 46M0917| Y| Y| N| N| N| N| N| N| Y| N| Y| N
ServeRAID M5000 Series Battery Remote Mount Cable| 68Y7396| N| N| N| N| N| N| N| N| Y| N| N| N
ServeRAID M5000 Series Advanced Feature Key| 46M0930| Y| Y| N| N| N| N| N| N| Y| N| Y| N
ServeRAID M5000 Series Performance Accelerator Key| 81Y4426| N| N| N| N| N| N| N| N| Y| N| Y| N

See ServerProven for the latest information about the System x servers that support each adapter: http://www.lenovo.com/us/en/serverproven/

Supported operating systems
The ServeRAID M5015 and ServeRAID M5014 adapter cards support the following operating systems

  • Microsoft Windows Server 2003, Web Edition
  • Microsoft Windows Server 2003/2003 R2, Datacenter Edition
  • Microsoft Windows Server 2003/2003 R2, Datacenter x64 Edition
  • Microsoft Windows Server 2003/2003 R2, Enterprise Edition
  • Microsoft Windows Server 2003/2003 R2, Enterprise x64 Edition
  • Microsoft Windows Server 2003/2003 R2, Standard Edition
  • Microsoft Windows Server 2003/2003 R2, Standard x64 Edition
  • Microsoft Windows Small Business Server 2003/2003 R2 Premium Edition
  • Microsoft Windows Small Business Server 2003/2003 R2 Standard Edition
  • Microsoft Windows Server 2008, Datacenter x64 Edition
  • Microsoft Windows Server 2008, Datacenter x86 Edition
  • Microsoft Windows Server 2008, Enterprise x64 Edition
  • Microsoft Windows Server 2008, Enterprise x86 Edition
  • Microsoft Windows Server 2008, Standard x64 Edition
  • Microsoft Windows Server 2008, Standard x86 Edition
  • Microsoft Windows Server 2008, Web x64 Edition
  • Microsoft Windows Server 2008, Web x86 Edition
  • Microsoft Windows Small Business Server 2008 Premium Edition
  • Microsoft Windows Small Business Server 2008 Standard Edition
  • Microsoft Windows Server 2008 R2
  • Microsoft Windows Server 2012
  • Microsoft Windows Server 2012 R2
  • Red Hat Enterprise Linux 4 AS for AMD64/EM64T
  • Red Hat Enterprise Linux 4 AS for x86
  • Red Hat Enterprise Linux 5 Server Edition
  • Red Hat Enterprise Linux 5 Server Edition with Xen
  • Red Hat Enterprise Linux 5 Server with Xen x64 Edition
  • Red Hat Enterprise Linux 5 Server x64 Edition
  • Red Hat Enterprise Linux 6 Server Edition
  • Red Hat Enterprise Linux 6 Server x64 Edition
  • SUSE LINUX Enterprise Server 10 for AMD64/EM64T
  • SUSE LINUX Enterprise Server 10 for x86
  • SUSE LINUX Enterprise Server 10 with Xen for AMD64/EM64T
  • SUSE LINUX Enterprise Server 11 for AMD64/EM64T
  • SUSE LINUX Enterprise Server 11 for x86
  • SUSE LINUX Enterprise Server 11 with Xen for AMD64/EM64T
  • Solaris 10 Operating System
  • VMware ESX 4.0
  • VMware ESX 4.1
  • VMware ESXi 4.0
  • VMware ESXi 4.1
  • VMware vSphere 5.0 (ESXi)
  • VMware vSphere 5.1 (ESXi)
  • VMware vSphere 5.5 (ESXi)

See the ServerProven Web site for the latest information about the specific versions and service packs supported: http://www.lenovo.com/us/en/serverproven/xseries/controllers/matrix.shtml Click the check mark that is associated with the System x server in question to see the details of the operating system support.

Related publications

For more information refer to the following documents

Related product families
Product families related to this document are the following: RAID Adapters

Notices

Lenovo may not offer the products, services, or features discussed in this document in all countries. Consult your local Lenovo representative for information on the products and services currently available in your area. Any reference to a Lenovo product, program, or service is not intended to state or imply that only that Lenovo product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any Lenovo intellectual property right may be used instead. However, it is the user’s responsibility to evaluate and verify the operation of any other product, program, or service. Lenovo may have patents or pending patent applications covering subject matter described in this document. The furnishing of this document does not give you any license to these patents. You can send license inquiries, in writing, to: Lenovo (United States), Inc. 8001 Development Drive Morrisville, NC 27560 U.S.A.

Attention : Lenovo Director of Licensing LENOVO PROVIDES THIS PUBLICATION ”AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some jurisdictions do not allow disclaimer of express or implied warranties in certain transactions, therefore, this statement may not apply to you. This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. Lenovo may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice. The products described in this document are not intended for use in implantation or other life support applications where malfunction may result in injury or death to persons.

The information contained in this document does not affect or change Lenovo product specifications or warranties. Nothing in this document shall operate as an express or implied license or indemnity under the intellectual property rights of Lenovo or third parties. All information contained in this document was obtained in specific environments and is presented as an illustration. The result obtained in other operating environments may vary. Lenovo may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you. Any references in this publication to non-Lenovo Web sites are provided for convenience only and do not in any manner serve as an endorsement of those Web sites. The materials at those Web sites are not part of the materials for this Lenovo product, and use of those Web sites is at your own risk.

Any performance data contained herein was determined in a controlled environment. Therefore, the result obtained in other operating environments may vary significantly. Some measurements may have been made on development- level systems and there is no guarantee that these measurements will be the same on generally available systems. Furthermore, some measurements may have been estimated through extrapolation. Actual results may vary. Users of this document should verify the applicable data for their specific environment. © Copyright Lenovo 2022. All rights reserved

This document, TIPS0738, was created or updated on April 22, 2016. Send us your comments in one of the following ways:

This document is available online at https://lenovopress.com/TIPS0738.

Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/. The following terms are trademarks of Lenovo in the United States, other countries, or both: Lenovo® ServeRAID ServerProven® System x® The following terms are trademarks of other companies: Linux® is the trademark of Linus Torvalds in the U.S. and other countries. Microsoft®, Windows Server®, and Windows® are trademarks of Microsoft Corporation in the United States, other countries, or both. Other company, product, or service names may be trademarks or service marks of others.

ServeRAID M5015 and M5014 SAS/SATA Controllers (withdrawn product)

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Lenovo User Manuals

Related Manuals