Specifications:
-
Model: MONOSPLIT DUCTED MEDIUM PRESSURE
-
Output Power (Cooling): 3.5 kW – 7.1 kW
-
Condensate Drain: Included with a maximum prevalence of 600
mm -
Control: Wired/Infrared control and Smart Control via hOn
APP -
Fresh Air: Allows introduction of clean air into the room
-
UVC Sterilisation: Built-in LED UV lights for killing airborne
hazards -
Flexible Air Distribution: Circular or rectangular
channels
Product Usage Instructions:
Installation:
The unit is designed for easy installation with a compact design
and a thickness of 248 mm for better adaptation.
Condensate Drain:
The medium-pressure ducted units come with a condensate drain
pump as standard, allowing for a maximum prevalence of 600 mm.
Condensate drain can also be performed by gravity on both
sides.
Control:
In addition to normal control options, the unit supports Smart
Control via the hOn APP, providing various functionalities
including on/off, operation mode selection, fan speed adjustment,
temperature control, air flow adjustment, scheduling, UV function,
and steri-clean 56OC.
Fresh Air and UVC Sterilisation:
The unit allows for air exchange to introduce clean air into the
room. The built-in LED UV lights help kill airborne hazards,
ensuring clean air circulation.
Air Distribution:
The ducted units offer flexible installation solutions with
options for circular or rectangular channels.
FAQ:
Q: Can the unit be controlled via WiFi?
A: Yes, in addition to normal wired/infrared control, the unit
supports WiFi control through the hOn APP.
Q: What is the maximum prevalence for condensate drain?
A: The maximum prevalence for condensate drain is 600 mm
measured from the base of the machine.
Q: Does the unit support air exchange for introducing clean
air?
A: Yes, the unit allows for air exchange to introduce clean air
into the room.
“`
MONOSPLIT
NEW
DUCTED MEDIUM PRESSURE
COMPACT DESIGN
The unit has a thickness of 248 mm which allows better adaptation and ease of
installation.
CONDENSATE DRAIN
The medium-pressure ducted units includes a condensate drain pump as standard.
This guarantees a maximum prevalence of 600 mm measured from the base of the
machine. There is the possibility of performing condensate drain by gravity
(reversible on both sides).
Max. 600mm
EASY INSTALLATION
· The connection of electrical cables is now possible through only one screw.
· The ducted units have two options for connecting the air extraction channel:
rear or lower.
WiFi
Besides normal wired/infrared control. Haier supplies Smart Control from hOn
APP. Including the on/off. operation mode selection, fan speed temperature,
and air flow adjustment, schedule, UV function and steri-clean 56OC, etc.
FRESH AIR
Air exchange allows introduction of clean air into the room.
UVC Sterilisation
The built-in LED UV lights kill airborne hazards when the air circulates from
air inlet, ensuring the clean air out.
Flexible air distribution
The ducted units satisfy multiple installation solutions (circular or
rectangular channels).
The data in this catalogue is purely indicative as the data may vary. Please
be advised to check the accuracy of the data with the supplier before
purchasing products.
Haierhvac.eu 91
NEW
DUCTED MEDIUM PRESSURE
238
248 165
128
158
AD35 – AD50 – AD71
578 (AD35) / 978 (AD50-AD71)
760 (AD35) / 1162 (AD50-AD71) 700 (AD35) / 1100 (AD50-AD71) 592 (AD35) / 992
(AD50-AD71)
95 100
700
620
123
1U35
800
592 (AD35) / 992 (AD50-AD71)
165
1U50
820
664143
553
275
330385
1U71
889600
773000
3,5 kW
92 Haierhvac.eu
5,0 kW
7,1 kW
334008
The data in this catalogue is purely indicative as the data may vary. Please
be advised to check the accuracy of the data with the supplier before
purchasing products.
MONOSPLIT
NEW
DUCTED MEDIUM PRESSURE
3,5 kW 5,0 kW 7,1 kW OPTIONAL CONTROL
26
dB(A)
UVC
Silence Compact Design
3D
· Low noise level
Condensate Drain Pump
Flexible Installation
UVC Sterilisation Wi-Fi control integrated
· Compact design
· `Fresh air’ knockout is incorporated in the chassis to allow fresh
air introduction of up to 20% of nominal unit air flow without
compromising the cooling capacity. Condensate drain pump
· UCV Sterilisation
· Wi-Fi control integrated
INDOOR UNIT
Model
OUTDOOR UNIT
Model
Performance data
Output power – COOLING
nom (min-max) kW
Output power – HEATING
nom (min-max) kW
Absorbed power COOLING
nom (min-max) kW
Absorbed power HEATING
nom (min-max) kW
Energy class
EER COP
W/W W/W
COOLING Pdesign
35 °C
kW
HEATING Pdesign
(-10 °C)
kW
Energy class
SEER SCOP
Annual Energy Consumption – COOLING
kWh/a
Annual Energy Consumption – HEATING
kWh/a
Indoor Unit
Power supply
Ph/V/Hz
Treated air volume
(H/M/L/Q) m3/h
External static pressure
Pa
High sound power
dB
Sound pressure
dB(A)
Net dimensions
WxDxH
mm
Packaging dimensions
WxDxH
mm
Net/gross weight
kg
Outdoor Unit
Power supply
Ph/V/Hz
Power cable
N x mm2
Interconnection cable
N x mm2
Sound power
H
dB
Sound pressure
H
dB(A)
Running current cooling/heating Max
A
Starting current cooling/heating Max
A
Net dimensions
WxDxH
mm
Packaging dimensions
WxDxH
mm
Net/gross weight
kg
Compressor type
Installation data
Refrigerant
Liquid pipe
Ø
mm (inch)
Gas pipe
Ø
mm (inch)
Standard pipe length without refrigerant charge m
Maximum pipe length
m
Maximum IU – OU elevation
m
Refrigerant charge in the factory
kg
Refrigerant charge in the factory
TCO2eq
Additional ref. charge over std length
g/m
Outdoor operating limits – COOLING min-max
°C
Outdoor operating limits – HEATING min-max
°C
AD35S2SM3FA(H) 1U35S2SM1FA-2
AD50S2SM3FA(H) 1U50S2SJ2FA-2
AD71S2SM3FA(H) 1U71S2SR2FA
3,50 (0,90-4,50) 4,00 (1,00-4,80) 1,08 (0,28-1,80) 1,08 (0,28-1,80)
3,23 3,71 3,50 2,70 6,10 (A++) 3,80 (A) 215 1020
5,00 (1,80-6,00) 6,00 (2,00-6,20) 1,55 (0,55-2,00) 1,48 (0,60-2,00)
3,23 3,71 5,00 4,50 6,10 (A++) 3,80 (A) 291 1782
7,10 (2,00-8,20) 7,50 (2,50-8,50) 2,20 (0,50-3,00) 2,02 (0,60-3,00)
3,23 3,71 7,10 5,00 6,10 (A++) 3,80 (A) 406 1827
1/220~240/50/60
1/220~240/50/60
1/220~240/50/60
840/720/600/450
1020/900/780/550
1440/1260/1100/900
25(default)/37/50/70/90/100/110/120/130/150
55
56
58
41/35/28/26
43/37/30/28
44/41/39/36
700x700x248
1100x700x248
1100x700x248
914x866x318
1316x866x318
1316x866x318
26,0/30,0
31,0/35,0
31,0/35,0
1/220~240/50 3 x 1,5 4 x 1,0 61 48 8,0 2,0
800x275x553 902x375x607
30,0/32,9 Rotary inverter
1/220~240/50 3 x 1,5 4 x 1,0 63 50 10,68 2,0
820x305x643 940x390x697
35,7/38,5 Rotary inverter
1/220~240/50/60 3 x 4,0 4 x 2,5 67 54 13,1 2,0
890x340x700 1046x460x780
45,0/50,0 Twin rotary inverter
R32 6,35 (1/4) 9,52 (3/8)
7 20 10 0,78 0,53 20
R32 6,35 (1/4) 12,70 (1/2)
7 25 15 1,10 0,74 20 -20~46 -20~24
R32 9,52 (3/8) 15,88 (5/8)
10 50 30 1,30 0,88 45
The data in this catalogue is purely indicative as the data may vary. Please be advised to check the accuracy of the data with the supplier before purchasing products.
Haierhvac.eu 93
NEW
DUCTED MEDIUM PRESSURE
AD105 – AD125
1378
1562
248
1500
238
700
619
1392
1U105
920
412.2 374.4
434.6 920
965 370 404 450
165
1U125
950
396
600 596
776650 372
10,5 kW
94 Haierhvac.eu
12,5 kW
The data in this catalogue is purely indicative as the data may vary. Please be advised to check the accuracy of the data with the supplier before purchasing products.
MONOSPLIT
NEW
DUCTED MEDIUM PRESSURE
10,5 kW 12,5 kW OPTIONAL CONTROL
26
dB(A)
UVC
Silence Compact Design
3D
· Low noise level
Condensate Drain Pump
Flexible Installation
UVC Sterilisation Wi-Fi control integrated
· Compact design
· `Fresh air’ knockout is incorporated in the chassis to allow fresh
air introduction of up to 20% of nominal unit air flow without
compromising the cooling capacity. Condensate drain pump
· UCV Sterilisation
· Wi-Fi control integrated
Unit R32 compatible
R410A
INDOOR UNIT
Model
OUTDOOR UNIT
Model
Performance data
Output power – COOLING
nom (min-max) kW
Output power – HEATING
nom (min-max) kW
Absorbed power COOLING
nom (min-max) kW
Absorbed power HEATING
nom (min-max) kW
Energy class
EER COP
W/W W/W
COOLING Pdesign
35 °C
kW
HEATING Pdesign
(-10 °C)
kW
Energy class
SEER SCOP
Annual Energy Consumption – COOLING
kWh/a
Annual Energy Consumption – HEATING
kWh/a
Indoor Unit
Power supply
Ph/V/Hz
Treated air volume
(H/M/L/Q) m3/h
External static pressure
Pa
High sound power
Sound pressure
Net dimensions
WxDxH
Packaging dimensions
WxDxH
Net/gross weight
Outdoor Unit
Power supply
Power cable
Interconnection cable
Sound power
H
Sound pressure
H
Running current cooling/heating Max
Starting current cooling/heating Max
Net dimensions
WxDxH
Packaging dimensions
WxDxH
Net/gross weight
Compressor type
Installation data
Refrigerant
Liquid pipe
Ø
Gas pipe
Ø
Standard pipe length without refrigerant charge
Maximum pipe length
Maximum IU – OU elevation
Refrigerant charge in the factory
Refrigerant charge in the factory
Additional ref. charge over std length
Outdoor operating limits – COOLING min-max
Outdoor operating limits – HEATING min-max
dB dB(A) mm mm kg
Ph/V/Hz N x mm2 N x mm2 dB dB(A) A A mm mm kg
mm (inch) mm (inch) m m m kg TCO2eq g/m °C °C
AD105S2SM3FA(H) 1U105S2SS2FA
AD105S2SM3FA(H) 1U105S2SS1FB
AD125S2SM8FA(H) 1U125S2SN2FA
AD125S2SM8FA(H) 1U125S2SN2FB
9,50 (2,50-10,00) 10,20 (3,00-10,50)
3,16 (0,50-4,00) 2,91 (0,50-4,00)
3,01 3,50 9,50 7,20 6,10 (A++) 3,80 (A) 544 2792
9,50 (2,50-10,00) 10,50 (3,00-11,00)
3,27 (0,50-4,00) 3,00 (0,50-4,00)
2,90 3,50 9,50 6,00 6,00 (A+) 3,91 (A) 569 2094
12,30 (3,00-13,00) 12,70 (3,50-13,50)
4,60 (1,00-6,00) 3,93 (1,00-6,00)
2,67 3,23 12,30 8,00 5,72 (A+) 3,93 (A) 735 3032
12,40 (3,00-13,00) 12,80 (3,50-13,50)
4,51 (1,00-6,00) 3,87 (1,00-6,00)
2,75 3,31 12,40 8,00 5,85 (A+) 3,96 (A) 718 3003
1/220~240/50/60 1600/1480/1360/1240
61 47/44/40/37 1500x700x248 1711x870x325
46,0/55,0
1/220~240/50/60
1/220~240/50/60
1600/1480/1360/1240 2250/1960/1680/1500
25/37(default)/50/70/90/100/110/120/130/150
64 47/44/40/37 1500x700x248 1711x870x325
46,0/55,0
65 48/45/42/39 1500x700x248 1711x870x325
48,0/57,0
1/220~240/50/60 2250/1960/1680/1500
65 48/45/42/39 1500x700x248 1711x870x325
48,0/57,0
1/220~240/50/60 3 x 4,0 4 x 2,5 66 53 16,5 3,0
920372765 1036478820
60,0/65,0 Twin rotary inverter
3/380~415/50/60 5 x 4,0 4 x 2,5 68 54 6,8 1,0
920372765 1085x485x830
61,0/66,0 Twin rotary inverter
1 /220~240/ 50/60 3 x 6,0 4 x 2,5 72 58 26,0 4,0
950x370x965 1050x485x1130
84,0/89,0 Twin rotary inverter
3 /380-415/ 50/60 5 x 4,0 4 x 2,5 72 58 10,0 2,0
950x370x965 1050x485x1130
85,0/90,0 Twin rotary inverter
R32 9,52 (3/8) 15,88 (5/8)
30 50 30 1,70 1,15 45
R32 9,52 (3/8) 15,88 (5/8)
30 50 30 1,70 1,15 45
-20~46 -20~24
R32 9,52 (3/8) 15,88 (5/8)
30 50 30 2,30 1,55 45
R32 9,52 (3/8) 15,88 (5/8)
30 50 30 2,30 1,55 45
The data in this catalogue is purely indicative as the data may vary. Please be advised to check the accuracy of the data with the supplier before purchasing products.
Haierhvac.eu 95
NEW
DUCTED MEDIUM PRESSURE
AD140 – AD160
1378
1562
248
1500
238
700
619
1392
1U140
950
396
165
1U140 – 1U160
950
370
1350 370 404 450
965 370 404 450
600 596
14,0 kW
96 Haierhvac.eu
14,0 kW
16,0 kW
600 595
The data in this catalogue is purely indicative as the data may vary. Please
be advised to check the accuracy of the data with the supplier before
purchasing products.
MONOSPLIT
NEW
DUCTED MEDIUM PRESSURE
14,0 kW 16,0 kW OPTIONAL CONTROL
26
dB(A)
UVC
Silence Compact Design
3D
· Low noise level
Condensate Drain Pump
Flexible Installation
UVC Sterilisation Wi-Fi control integrated
· Compact design
· `Fresh air’ knockout is incorporated in the chassis to allow fresh
air introduction of up to 20% of nominal unit air flow without
compromising the cooling capacity. Condensate drain pump
· UCV Sterilisation
· Wi-Fi control integrated
Unit R32 compatible
R410A
INDOOR UNIT
Model
OUTDOOR UNIT
Model
Performance data
Output power – COOLING
nom (min-max) kW
Output power – HEATING
nom (min-max) kW
Absorbed power COOLING
nom (min-max) kW
Absorbed power HEATING
nom (min-max) kW
Energy class
EER COP
W/W W/W
COOLING Pdesign
35 °C
kW
HEATING Pdesign
(-10 °C)
kW
Energy class
SEER SCOP
Annual Energy Consumption – COOLING
kWh/a
Annual Energy Consumption – HEATING
kWh/a
Indoor Unit
Power supply
Ph/V/Hz
Treated air volume
(H/M/L/Q) m3/h
External static pressure
Pa
High sound power
dB
Sound pressure
dB(A)
Net dimensions
WxDxH
mm
Packaging dimensions
WxDxH
mm
Net/gross weight
kg
Outdoor Unit
Power supply
Ph/V/Hz
Power cable
N x mm2
Interconnection cable
N x mm2
Sound power
H
dB
Sound pressure
H
dB(A)
Running current cooling/heating Max
A
Starting current cooling/heating Max
A
Net dimensions
WxDxH
mm
Packaging dimensions
WxDxH
mm
Net/gross weight
kg
Compressor type
Installation data
Refrigerant
Liquid pipe
Ø
mm (inch)
Gas pipe
Ø
mm (inch)
Standard pipe length without refrigerant charge m
Maximum pipe length
m
Maximum IU – OU elevation
m
Refrigerant charge in the factory
kg
Refrigerant charge in the factory
TCO2eq
Additional ref. charge over std length
g/m
Outdoor operating limits COOLING
min-max
°C
Outdoor operating limits – HEATING min-max
°C
AD140S2SM8FA(H) AD140S2SM8FA(H) AD140S2SM8FA(H) AD140S2SM8FA(H) AD160S2SM3FA(H) 1U140S2SN1FA 1U140S2SN1FB 1U140S2SP2FA 1U140S2SP2FB 1U160S2SP1FB
13,40 (3,50-14,00) 13,40 (3,50-14,00) 13,40 (4,00-15,00) 13,40 (4,00-15,00) 16,00 (4,50-16,50)
15,00 (4,00-15,50) 15,00 (4,00-15,50) 15,00 (4,50-16,00) 15,00 (4,50-16,00) 17,00 (5,00-18,00)
5,28 (1,00-6,50) 5,18 (1,00-6,50) 4,17 (1,00-6,00) 4,15 (1,00-6,00) 5,48 (1,00-6,50)
4,92 (1,00-6,50) 4,79 (1,00-6,50) 4,04 (1,00-6,00) 4,02 (1,00-6,00) 4,82 (1,00-6,50)
2,54
2,59
3,21
3,23
2,92
3,05
3,13
3,71
3,73
3,53
13,40
13,40
13,40
13,40
16,00
8,50
8,50
11,00
11,00
11,00
5,62 (A+)
5,64 (A+)
6,16 (A++)
6,19 (A++)
5,94 (A+)
3,93 (A)
3,96 (A)
4,06 (A+)
4,06 (A+)
4,06 (A+)
835
832
761
758
943
3032
3003
3796
3798
3798
1/220~240/50/60 1/220~240/50/60 1/220~240/50/60 1/220~240/50/60 1/220~240/50/60
2500/2160/1780/1500 2500/2160/1780/1500 2500/2160/1780/1500 2500/2160/1780/1500 2500/2160/1780/1500
25/37(default)/50/70/90/100/110/120/130/150
66
66
66
66
67
48/45/42/39
48/45/42/39
48/45/42/39
48/45/42/39
48/45/42/39
1500x700x248 1500x700x248 1500x700x248 1500x700x248 1500x700x248
1711x870x325 1711x870x325 1711x870x325 1711x870x325 1711x870x325
48,0/57,0
48,0/57,0
48,0/57,0
48,0/57,0
48,0/57,0
1 /220~240/ 50/60 3 /380-415/ 50/60 1/220~240/50/60 3/380~415/50/60 3/380~415/50/60
3 x 6,0
5 x 4,0
3 x 6,0
5 x 4,0
5 x 4,0
4 x 2,5
4 x 2,5
4 x 2,5
4 x 2,5
4 x 2,5
72
72
70
70
72
58
58
53
53
58
30,0
10,0
32,0
10,0
10,0
5,0
2,0
6,0
2,0
2,0
950x370x965
950x370x965 950x370x1350 950x370x1350 950x370x1350
1050x485x1130 1050x485x1130 1050x485x1500 1050x485x1500 1050x485x1500
84,0/89,0
85,0/90,0
105,0/118,0
101,0/116,0
101,0/116,0
Twin rotary inverter Twin rotary inverter Twin rotary inverter Twin rotary inverter Twin rotary inverter
R32 9,52 (3/8) 15,88 (5/8)
30 70 30 2,30 1,55 45
R32 9,52 (3/8) 15,88 (5/8)
30 70 30 2,30 1,55 45
R32 9,52 (3/8) 15,88 (5/8)
30 70 30 2,90 1,96 45
-20~46
-20~24
R32 9,52 (3/8) 15,88 (5/8)
30 70 30 3,50 2,36 45
R32 9,52 (3/8) 19,05 (3/4)
30 70 30 3,50 2,36 45
The data in this catalogue is purely indicative as the data may vary. Please be advised to check the accuracy of the data with the supplier before purchasing products.