Haier AD140S2SM3FA Commercial Ducted Medium Pressure Indoor AC Unit Instruction Manual

June 1, 2024
Haier

AD140S2SM3FA Commercial Ducted Medium Pressure Indoor AC Unit

“`html

Specifications:

  • Model: MONOSPLIT DUCTED MEDIUM PRESSURE

  • Output Power (Cooling): 3.5 kW – 7.1 kW

  • Condensate Drain: Included with a maximum prevalence of 600
    mm

  • Control: Wired/Infrared control and Smart Control via hOn
    APP

  • Fresh Air: Allows introduction of clean air into the room

  • UVC Sterilisation: Built-in LED UV lights for killing airborne
    hazards

  • Flexible Air Distribution: Circular or rectangular
    channels

Product Usage Instructions:

Installation:

The unit is designed for easy installation with a compact design
and a thickness of 248 mm for better adaptation.

Condensate Drain:

The medium-pressure ducted units come with a condensate drain
pump as standard, allowing for a maximum prevalence of 600 mm.
Condensate drain can also be performed by gravity on both
sides.

Control:

In addition to normal control options, the unit supports Smart
Control via the hOn APP, providing various functionalities
including on/off, operation mode selection, fan speed adjustment,
temperature control, air flow adjustment, scheduling, UV function,
and steri-clean 56OC.

Fresh Air and UVC Sterilisation:

The unit allows for air exchange to introduce clean air into the
room. The built-in LED UV lights help kill airborne hazards,
ensuring clean air circulation.

Air Distribution:

The ducted units offer flexible installation solutions with
options for circular or rectangular channels.

FAQ:

Q: Can the unit be controlled via WiFi?

A: Yes, in addition to normal wired/infrared control, the unit
supports WiFi control through the hOn APP.

Q: What is the maximum prevalence for condensate drain?

A: The maximum prevalence for condensate drain is 600 mm
measured from the base of the machine.

Q: Does the unit support air exchange for introducing clean

air?

A: Yes, the unit allows for air exchange to introduce clean air
into the room.

“`

MONOSPLIT

NEW
DUCTED MEDIUM PRESSURE
COMPACT DESIGN
The unit has a thickness of 248 mm which allows better adaptation and ease of installation.

CONDENSATE DRAIN
The medium-pressure ducted units includes a condensate drain pump as standard. This guarantees a maximum prevalence of 600 mm measured from the base of the machine. There is the possibility of performing condensate drain by gravity (reversible on both sides).

Max. 600mm

EASY INSTALLATION
· The connection of electrical cables is now possible through only one screw.
· The ducted units have two options for connecting the air extraction channel: rear or lower.
WiFi
Besides normal wired/infrared control. Haier supplies Smart Control from hOn APP. Including the on/off. operation mode selection, fan speed temperature, and air flow adjustment, schedule, UV function and steri-clean 56OC, etc.
FRESH AIR
Air exchange allows introduction of clean air into the room.
UVC Sterilisation
The built-in LED UV lights kill airborne hazards when the air circulates from air inlet, ensuring the clean air out.
Flexible air distribution
The ducted units satisfy multiple installation solutions (circular or rectangular channels).
The data in this catalogue is purely indicative as the data may vary. Please be advised to check the accuracy of the data with the supplier before purchasing products.

Haierhvac.eu 91

NEW
DUCTED MEDIUM PRESSURE

238

248 165
128
158

AD35 – AD50 – AD71
578 (AD35) / 978 (AD50-AD71)
760 (AD35) / 1162 (AD50-AD71) 700 (AD35) / 1100 (AD50-AD71) 592 (AD35) / 992 (AD50-AD71)

95 100

700

620

123

1U35
800

592 (AD35) / 992 (AD50-AD71)

165

1U50
820

664143

553

275

330385

1U71
889600

773000

3,5 kW
92 Haierhvac.eu

5,0 kW

7,1 kW

334008
The data in this catalogue is purely indicative as the data may vary. Please be advised to check the accuracy of the data with the supplier before purchasing products.

MONOSPLIT

NEW
DUCTED MEDIUM PRESSURE

3,5 kW 5,0 kW 7,1 kW OPTIONAL CONTROL

26
dB(A)
UVC

Silence Compact Design

3D

· Low noise level

Condensate Drain Pump

Flexible Installation

UVC Sterilisation Wi-Fi control integrated

· Compact design

· `Fresh air’ knockout is incorporated in the chassis to allow fresh

air introduction of up to 20% of nominal unit air flow without

compromising the cooling capacity. Condensate drain pump

· UCV Sterilisation

· Wi-Fi control integrated

INDOOR UNIT

Model

OUTDOOR UNIT

Model

Performance data

Output power – COOLING

nom (min-max) kW

Output power – HEATING

nom (min-max) kW

Absorbed power ­ COOLING

nom (min-max) kW

Absorbed power ­ HEATING

nom (min-max) kW

Energy class

EER COP

W/W W/W

COOLING Pdesign

35 °C

kW

HEATING Pdesign

(-10 °C)

kW

Energy class

SEER SCOP

Annual Energy Consumption – COOLING

kWh/a

Annual Energy Consumption – HEATING

kWh/a

Indoor Unit

Power supply

Ph/V/Hz

Treated air volume

(H/M/L/Q) m3/h

External static pressure

Pa

High sound power

dB

Sound pressure

dB(A)

Net dimensions

WxDxH

mm

Packaging dimensions

WxDxH

mm

Net/gross weight

kg

Outdoor Unit

Power supply

Ph/V/Hz

Power cable

N x mm2

Interconnection cable

N x mm2

Sound power

H

dB

Sound pressure

H

dB(A)

Running current cooling/heating Max

A

Starting current cooling/heating Max

A

Net dimensions

WxDxH

mm

Packaging dimensions

WxDxH

mm

Net/gross weight

kg

Compressor type

Installation data

Refrigerant

Liquid pipe

Ø

mm (inch)

Gas pipe

Ø

mm (inch)

Standard pipe length without refrigerant charge m

Maximum pipe length

m

Maximum IU – OU elevation

m

Refrigerant charge in the factory

kg

Refrigerant charge in the factory

TCO2eq

Additional ref. charge over std length

g/m

Outdoor operating limits – COOLING min-max

°C

Outdoor operating limits – HEATING min-max

°C

AD35S2SM3FA(H) 1U35S2SM1FA-2

AD50S2SM3FA(H) 1U50S2SJ2FA-2

AD71S2SM3FA(H) 1U71S2SR2FA

3,50 (0,90-4,50) 4,00 (1,00-4,80) 1,08 (0,28-1,80) 1,08 (0,28-1,80)
3,23 3,71 3,50 2,70 6,10 (A++) 3,80 (A) 215 1020

5,00 (1,80-6,00) 6,00 (2,00-6,20) 1,55 (0,55-2,00) 1,48 (0,60-2,00)
3,23 3,71 5,00 4,50 6,10 (A++) 3,80 (A) 291 1782

7,10 (2,00-8,20) 7,50 (2,50-8,50) 2,20 (0,50-3,00) 2,02 (0,60-3,00)
3,23 3,71 7,10 5,00 6,10 (A++) 3,80 (A) 406 1827

1/220~240/50/60

1/220~240/50/60

1/220~240/50/60

840/720/600/450

1020/900/780/550

1440/1260/1100/900

25(default)/37/50/70/90/100/110/120/130/150

55

56

58

41/35/28/26

43/37/30/28

44/41/39/36

700x700x248

1100x700x248

1100x700x248

914x866x318

1316x866x318

1316x866x318

26,0/30,0

31,0/35,0

31,0/35,0

1/220~240/50 3 x 1,5 4 x 1,0 61 48 8,0 2,0
800x275x553 902x375x607
30,0/32,9 Rotary inverter

1/220~240/50 3 x 1,5 4 x 1,0 63 50 10,68 2,0
820x305x643 940x390x697
35,7/38,5 Rotary inverter

1/220~240/50/60 3 x 4,0 4 x 2,5 67 54 13,1 2,0
890x340x700 1046x460x780
45,0/50,0 Twin rotary inverter

R32 6,35 (1/4) 9,52 (3/8)
7 20 10 0,78 0,53 20

R32 6,35 (1/4) 12,70 (1/2)
7 25 15 1,10 0,74 20 -20~46 -20~24

R32 9,52 (3/8) 15,88 (5/8)
10 50 30 1,30 0,88 45

The data in this catalogue is purely indicative as the data may vary. Please be advised to check the accuracy of the data with the supplier before purchasing products.

Haierhvac.eu 93

NEW
DUCTED MEDIUM PRESSURE

AD105 – AD125
1378

1562

248

1500

238

700

619

1392

1U105
920

412.2 374.4

434.6 920

965 370 404 450

165

1U125

950

396

600 596

776650 372

10,5 kW
94 Haierhvac.eu

12,5 kW

The data in this catalogue is purely indicative as the data may vary. Please be advised to check the accuracy of the data with the supplier before purchasing products.

MONOSPLIT

NEW
DUCTED MEDIUM PRESSURE

10,5 kW 12,5 kW OPTIONAL CONTROL

26
dB(A)
UVC

Silence Compact Design

3D

· Low noise level

Condensate Drain Pump

Flexible Installation

UVC Sterilisation Wi-Fi control integrated

· Compact design

· `Fresh air’ knockout is incorporated in the chassis to allow fresh

air introduction of up to 20% of nominal unit air flow without

compromising the cooling capacity. Condensate drain pump

· UCV Sterilisation

· Wi-Fi control integrated

Unit R32 compatible
R410A

INDOOR UNIT

Model

OUTDOOR UNIT

Model

Performance data

Output power – COOLING

nom (min-max) kW

Output power – HEATING

nom (min-max) kW

Absorbed power ­ COOLING

nom (min-max) kW

Absorbed power ­ HEATING

nom (min-max) kW

Energy class

EER COP

W/W W/W

COOLING Pdesign

35 °C

kW

HEATING Pdesign

(-10 °C)

kW

Energy class

SEER SCOP

Annual Energy Consumption – COOLING

kWh/a

Annual Energy Consumption – HEATING

kWh/a

Indoor Unit

Power supply

Ph/V/Hz

Treated air volume

(H/M/L/Q) m3/h

External static pressure

Pa

High sound power

Sound pressure

Net dimensions

WxDxH

Packaging dimensions

WxDxH

Net/gross weight

Outdoor Unit

Power supply

Power cable

Interconnection cable

Sound power

H

Sound pressure

H

Running current cooling/heating Max

Starting current cooling/heating Max

Net dimensions

WxDxH

Packaging dimensions

WxDxH

Net/gross weight

Compressor type

Installation data

Refrigerant

Liquid pipe

Ø

Gas pipe

Ø

Standard pipe length without refrigerant charge

Maximum pipe length

Maximum IU – OU elevation

Refrigerant charge in the factory

Refrigerant charge in the factory

Additional ref. charge over std length

Outdoor operating limits – COOLING min-max

Outdoor operating limits – HEATING min-max

dB dB(A) mm mm kg
Ph/V/Hz N x mm2 N x mm2 dB dB(A) A A mm mm kg
mm (inch) mm (inch) m m m kg TCO2eq g/m °C °C

AD105S2SM3FA(H) 1U105S2SS2FA

AD105S2SM3FA(H) 1U105S2SS1FB

AD125S2SM8FA(H) 1U125S2SN2FA

AD125S2SM8FA(H) 1U125S2SN2FB

9,50 (2,50-10,00) 10,20 (3,00-10,50)
3,16 (0,50-4,00) 2,91 (0,50-4,00)
3,01 3,50 9,50 7,20 6,10 (A++) 3,80 (A) 544 2792

9,50 (2,50-10,00) 10,50 (3,00-11,00)
3,27 (0,50-4,00) 3,00 (0,50-4,00)
2,90 3,50 9,50 6,00 6,00 (A+) 3,91 (A) 569 2094

12,30 (3,00-13,00) 12,70 (3,50-13,50)
4,60 (1,00-6,00) 3,93 (1,00-6,00)
2,67 3,23 12,30 8,00 5,72 (A+) 3,93 (A) 735 3032

12,40 (3,00-13,00) 12,80 (3,50-13,50)
4,51 (1,00-6,00) 3,87 (1,00-6,00)
2,75 3,31 12,40 8,00 5,85 (A+) 3,96 (A) 718 3003

1/220~240/50/60 1600/1480/1360/1240
61 47/44/40/37 1500x700x248 1711x870x325
46,0/55,0

1/220~240/50/60

1/220~240/50/60

1600/1480/1360/1240 2250/1960/1680/1500

25/37(default)/50/70/90/100/110/120/130/150

64 47/44/40/37 1500x700x248 1711x870x325
46,0/55,0

65 48/45/42/39 1500x700x248 1711x870x325
48,0/57,0

1/220~240/50/60 2250/1960/1680/1500
65 48/45/42/39 1500x700x248 1711x870x325
48,0/57,0

1/220~240/50/60 3 x 4,0 4 x 2,5 66 53 16,5 3,0
920372765 1036478820
60,0/65,0 Twin rotary inverter

3/380~415/50/60 5 x 4,0 4 x 2,5 68 54 6,8 1,0
920372765 1085x485x830
61,0/66,0 Twin rotary inverter

1 /220~240/ 50/60 3 x 6,0 4 x 2,5 72 58 26,0 4,0
950x370x965 1050x485x1130
84,0/89,0 Twin rotary inverter

3 /380-415/ 50/60 5 x 4,0 4 x 2,5 72 58 10,0 2,0
950x370x965 1050x485x1130
85,0/90,0 Twin rotary inverter

R32 9,52 (3/8) 15,88 (5/8)
30 50 30 1,70 1,15 45

R32 9,52 (3/8) 15,88 (5/8)
30 50 30 1,70 1,15 45

-20~46 -20~24

R32 9,52 (3/8) 15,88 (5/8)
30 50 30 2,30 1,55 45

R32 9,52 (3/8) 15,88 (5/8)
30 50 30 2,30 1,55 45

The data in this catalogue is purely indicative as the data may vary. Please be advised to check the accuracy of the data with the supplier before purchasing products.

Haierhvac.eu 95

NEW
DUCTED MEDIUM PRESSURE

AD140 – AD160
1378

1562

248

1500

238

700

619

1392

1U140

950

396

165

1U140 – 1U160

950

370

1350 370 404 450

965 370 404 450

600 596

14,0 kW
96 Haierhvac.eu

14,0 kW

16,0 kW

600 595
The data in this catalogue is purely indicative as the data may vary. Please be advised to check the accuracy of the data with the supplier before purchasing products.

MONOSPLIT

NEW
DUCTED MEDIUM PRESSURE

14,0 kW 16,0 kW OPTIONAL CONTROL

26
dB(A)
UVC

Silence Compact Design

3D

· Low noise level

Condensate Drain Pump

Flexible Installation

UVC Sterilisation Wi-Fi control integrated

· Compact design

· `Fresh air’ knockout is incorporated in the chassis to allow fresh

air introduction of up to 20% of nominal unit air flow without

compromising the cooling capacity. Condensate drain pump

· UCV Sterilisation

· Wi-Fi control integrated

Unit R32 compatible
R410A

INDOOR UNIT

Model

OUTDOOR UNIT

Model

Performance data

Output power – COOLING

nom (min-max) kW

Output power – HEATING

nom (min-max) kW

Absorbed power ­ COOLING

nom (min-max) kW

Absorbed power ­ HEATING

nom (min-max) kW

Energy class

EER COP

W/W W/W

COOLING Pdesign

35 °C

kW

HEATING Pdesign

(-10 °C)

kW

Energy class

SEER SCOP

Annual Energy Consumption – COOLING

kWh/a

Annual Energy Consumption – HEATING

kWh/a

Indoor Unit

Power supply

Ph/V/Hz

Treated air volume

(H/M/L/Q) m3/h

External static pressure

Pa

High sound power

dB

Sound pressure

dB(A)

Net dimensions

WxDxH

mm

Packaging dimensions

WxDxH

mm

Net/gross weight

kg

Outdoor Unit

Power supply

Ph/V/Hz

Power cable

N x mm2

Interconnection cable

N x mm2

Sound power

H

dB

Sound pressure

H

dB(A)

Running current cooling/heating Max

A

Starting current cooling/heating Max

A

Net dimensions

WxDxH

mm

Packaging dimensions

WxDxH

mm

Net/gross weight

kg

Compressor type

Installation data

Refrigerant

Liquid pipe

Ø

mm (inch)

Gas pipe

Ø

mm (inch)

Standard pipe length without refrigerant charge m

Maximum pipe length

m

Maximum IU – OU elevation

m

Refrigerant charge in the factory

kg

Refrigerant charge in the factory

TCO2eq

Additional ref. charge over std length

g/m

Outdoor operating limits COOLING

min-max

°C

Outdoor operating limits – HEATING min-max

°C

AD140S2SM8FA(H) AD140S2SM8FA(H) AD140S2SM8FA(H) AD140S2SM8FA(H) AD160S2SM3FA(H) 1U140S2SN1FA 1U140S2SN1FB 1U140S2SP2FA 1U140S2SP2FB 1U160S2SP1FB

13,40 (3,50-14,00) 13,40 (3,50-14,00) 13,40 (4,00-15,00) 13,40 (4,00-15,00) 16,00 (4,50-16,50)

15,00 (4,00-15,50) 15,00 (4,00-15,50) 15,00 (4,50-16,00) 15,00 (4,50-16,00) 17,00 (5,00-18,00)

5,28 (1,00-6,50) 5,18 (1,00-6,50) 4,17 (1,00-6,00) 4,15 (1,00-6,00) 5,48 (1,00-6,50)

4,92 (1,00-6,50) 4,79 (1,00-6,50) 4,04 (1,00-6,00) 4,02 (1,00-6,00) 4,82 (1,00-6,50)

2,54

2,59

3,21

3,23

2,92

3,05

3,13

3,71

3,73

3,53

13,40

13,40

13,40

13,40

16,00

8,50

8,50

11,00

11,00

11,00

5,62 (A+)

5,64 (A+)

6,16 (A++)

6,19 (A++)

5,94 (A+)

3,93 (A)

3,96 (A)

4,06 (A+)

4,06 (A+)

4,06 (A+)

835

832

761

758

943

3032

3003

3796

3798

3798

1/220~240/50/60 1/220~240/50/60 1/220~240/50/60 1/220~240/50/60 1/220~240/50/60

2500/2160/1780/1500 2500/2160/1780/1500 2500/2160/1780/1500 2500/2160/1780/1500 2500/2160/1780/1500

25/37(default)/50/70/90/100/110/120/130/150

66

66

66

66

67

48/45/42/39

48/45/42/39

48/45/42/39

48/45/42/39

48/45/42/39

1500x700x248 1500x700x248 1500x700x248 1500x700x248 1500x700x248

1711x870x325 1711x870x325 1711x870x325 1711x870x325 1711x870x325

48,0/57,0

48,0/57,0

48,0/57,0

48,0/57,0

48,0/57,0

1 /220~240/ 50/60 3 /380-415/ 50/60 1/220~240/50/60 3/380~415/50/60 3/380~415/50/60

3 x 6,0

5 x 4,0

3 x 6,0

5 x 4,0

5 x 4,0

4 x 2,5

4 x 2,5

4 x 2,5

4 x 2,5

4 x 2,5

72

72

70

70

72

58

58

53

53

58

30,0

10,0

32,0

10,0

10,0

5,0

2,0

6,0

2,0

2,0

950x370x965

950x370x965 950x370x1350 950x370x1350 950x370x1350

1050x485x1130 1050x485x1130 1050x485x1500 1050x485x1500 1050x485x1500

84,0/89,0

85,0/90,0

105,0/118,0

101,0/116,0

101,0/116,0

Twin rotary inverter Twin rotary inverter Twin rotary inverter Twin rotary inverter Twin rotary inverter

R32 9,52 (3/8) 15,88 (5/8)
30 70 30 2,30 1,55 45

R32 9,52 (3/8) 15,88 (5/8)
30 70 30 2,30 1,55 45

R32 9,52 (3/8) 15,88 (5/8)
30 70 30 2,90 1,96 45
-20~46
-20~24

R32 9,52 (3/8) 15,88 (5/8)
30 70 30 3,50 2,36 45

R32 9,52 (3/8) 19,05 (3/4)
30 70 30 3,50 2,36 45

The data in this catalogue is purely indicative as the data may vary. Please be advised to check the accuracy of the data with the supplier before purchasing products.

Haierhvac.eu 97

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals