TRIVIDIA HEALTH ZEA4TVH08 TRUENESS AIR Blood Glucose Meter User Guide

June 1, 2024
TRIVIDIA HEALTH

TRIVIDIA HEALTH ZEA4TVH08 TRUENESS AIR Blood Glucose Meter

TRIVIDIA-HEALTH-ZEA4TVH08-TRUENESS-AIR-Blood-Glucose-Meter-
Product

Product Information

Specifications:

  • Blood Glucose Meter
  • Test strip port
  • Quick Reference Guide
  • Lancing Device and Lancet
  • Manufacturer: [Manufacturer Name]
  • Model Number: P/N 36301323-A.6

Product Usage Instructions

Before You Test:

  1. Contact your doctor or healthcare professional to determine the testing frequency and target ranges for blood glucose levels.
  2. Read the Owner’s Booklet and Quick Reference Guide carefully before testing.
  3. Wash hands thoroughly and refer to lancing device Instructions for detailed cleaning instructions.

Testing Process:

  1. Remove the lancing device cover.
  2. Insert a lancet into the lancing device until it stops, then remove the lancet cap.
  3. Adjust the puncture depth using the depth dial.
  4. Arm the lancing device by pulling back the spring mechanism.
  5. Insert the test strip contact end into the test port with the meter off.
  6. Once the meter turns on, apply the blood sample to the tip of the test strip when the blood symbol flashes.
  7. Hold the test strip until the meter beeps, and then discard it according to a healthcare professional’s instructions.
  8. Repeat if necessary for a sufficient blood sample.
  9. After a 5-second countdown, the meter displays the test result.
  10. Remove the lancing device cover, dispose of the used lancet and cap properly, and replace the cover.

FAQ

  • Q: How often should I test my blood glucose levels?
    A: Contact your doctor or healthcare professional to determine your testing frequency based on your specific needs.

  • Q: What should I do if I don’t produce enough blood for the test?
    A: Gently massage your finger to encourage blood flow. Do not squeeze your finger. Adjust the puncture depth and try again if needed.

Blood Glucose Meter

TRIVIDIA-HEALTH-ZEA4TVH08-TRUENESS-AIR-Blood-Glucose-Meter-Fig-
\(1\)

Lancing Device and Lancet

  • Images are for illustration purposes only. Your lancing device/lancet may look different.
  • Refer to your lancing device/lancet instructions for use for detailed information.

TRIVIDIA-HEALTH-ZEA4TVH08-TRUENESS-AIR-Blood-Glucose-Meter-Fig-
\(2\)

Test Strip

TRIVIDIA-HEALTH-ZEA4TVH08-TRUENESS-AIR-Blood-Glucose-Meter-Fig-
\(3\)

Before You Test

Caution:
Before testing, please read the Owner’s Booklet and this Quick Reference Guide carefully.

  • Contact your doctor or healthcare professional to determine how often you should test and what your target ranges are for blood glucose results.
  • ALWAYS read the Owner’s Booklet before testing for the first time and before using this Quick Reference Guide.

Let’s start the blood glucose test now

  1. Wash hands. Rinse well. Dry thoroughly. Refer to lancing device Instructions for Use for detailed instructions on cleaning and disinfecting the fingertip.TRIVIDIA-HEALTH-ZEA4TVH08-TRUENESS-AIR-Blood-Glucose-Meter-Fig- \(4\)

  2. Pull to remove the lancing device cover. TRIVIDIA-HEALTH-ZEA4TVH08-TRUENESS-AIR-Blood-Glucose-Meter-Fig- \(5\)

  3. Insert a lancet into the lancing device until it comes to a full stop. Remove the lancet cap.

  4. Push the lancing device cover back on. TRIVIDIA-HEALTH-ZEA4TVH08-TRUENESS-AIR-Blood-Glucose-Meter-Fig- \(6\)

  5. Twist the depth dial to adjust the puncture depth. Choose a higher number for deeper puncture depth.TRIVIDIA-HEALTH-ZEA4TVH08-TRUENESS-AIR-Blood-Glucose-Meter-Fig- \(7\)

  6. Pull the spring mechanism back to arm the lancing device.TRIVIDIA-HEALTH-ZEA4TVH08-TRUENESS-AIR-Blood-Glucose-Meter-Fig- \(8\)

  7. Remove one test strip from vial. Close vial immediately. Use test strip quickly after removal from vial.TRIVIDIA-HEALTH-ZEA4TVH08-TRUENESS-AIR-Blood-Glucose-Meter-Fig- \(9\)

  8. Insert the test strip’s contact end (blocks facing up) into the test port. Meter turns on. Keep the test strip in the meter until testing is finished.TRIVIDIA-HEALTH-ZEA4TVH08-TRUENESS-AIR-Blood-Glucose-Meter-Fig- \(10\)

  9. Make sure the lancing device is pressed firmly to your finger. Press the release button to lance.
    Attention: If you did not produce a large enough blood sample, gently massage your finger. DO NOT SQUEEZE YOUR FINGER. Adjust the puncture depth and lance again.TRIVIDIA-HEALTH-ZEA4TVH08-TRUENESS-AIR-Blood-Glucose-Meter-Fig-
\(11\)

  10. With test strip still in meter, the meter screen displays the flashing blood symbol, apply the blood sample to the tip of the Test Strip. Hold the tip of the test strip to the blood drop until the meter beeps.TRIVIDIA-HEALTH-ZEA4TVH08-TRUENESS-AIR-Blood-Glucose-Meter-Fig- \(12\)

  11. After a 5-second count the meter displays the test result.TRIVIDIA-HEALTH-ZEA4TVH08-TRUENESS-AIR-Blood-Glucose-Meter-Fig- \(13\)

  12. Hold meter with test strip pointing down. Press test strip release button to discard test strip according to your healthcare professional’s instructions or dispose them in an appropriate trash container. Meter turns off.TRIVIDIA-HEALTH-ZEA4TVH08-TRUENESS-AIR-Blood-Glucose-Meter-Fig- \(14\)

  13. Remove the lancing device cover. With the lancet cap on the table, stick the needle of the lancet into the lancet cap and remove lancet from lancing device. Please discard them carefully according to your healthcare professional’s instructions or dispose them in an appropriate trash container. Replace the lancing device cover. TRIVIDIA-HEALTH-ZEA4TVH08-TRUENESS-AIR-Blood-Glucose-Meter-Fig- \(15\)

Customer Consultation
English or Spanish, Monday-Friday, 8 a.m.–8 p.m. EST, 1-800-803-6025, www.trividiahealth.com.

  1. FDA Public Health Notification: Use of Fingerstick Devices on More than One Person Poses Risk for Transmitting Bloodborne Pathogens: Initial Communication. Available at https://wayback.archive-it.
    org/7993/20170111013014/http://www.fda.gov/MedicalDevices/SafetyAlertsandNotices/ucm224025.htm.

  2. Glucose Monitoring and Insulin Administration: Available at https://www.cdc.gov/injectionsafety/blood-glucose-monitoring.html.

© 2024 Trividia Health, Inc. TRUENESS and Trividia Health logo are trademarks of Trividia Health, Inc. Made in China.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals