BRIGGS STRATTON 040806 Residential Standby Generators User Guide
- June 1, 2024
- BRIGGS STRATTON
Table of Contents
BRIGGS STRATTON 040806 Residential Standby Generators
SPECIFICATIONS
OVERVIEW
Brand| Briggs & Stratton®
Series Name| Power Protect™
Model Name| PP26
Model Number| 040806
Rated AC Voltage (Volts)| 120 / 240
Frequency (Hz)| 60
Generator Breaker (Amps)| 125
Operating Ambient Temperature (°C / °F)| -28 – 40 / -20
– 104
Running Amperage, Standby (LP / NG) (Amps)| 108.3 / 100
Running Power, Standby (LP / NG) (kW)| 261 / 24
Power Factor| 1.0
Programmable Exercise Cycle| 16 sec (default) – 20 mins
Engine
Engine Brand/Manufacturer| Vanguard®
Model Type| M61
Aspiration| Naturally Aspirated
Speed (RPM)| 3600
Displacement (ci/cc)| 61 / 993
Compression Ratio| 9.7:1
Governor Type| Electronic
Engine
Bore & Stroke (mm **/ in)| 85.5 x 86.5 / 3.37 x 3.41
Cylinder Block| Aluminum with Cast Iron Sleeve
Valve Arrangement| OHV
Engine Cylinder Configuration| V
Number of Cylinders| 2
Start Type| Automatic
Frequency Regulation Steady State, No Load to Full Load (%)| +/- 1.0
Air Filter Type| Dry
Low Oil Pressure Switch| Yes
Engine Oil Heater| Optional
Rated Temperature (°C / °F)| 25 / 77
Sound Rating 2
Low Idle Mode Sound dB(A)| 63
Normal Operating Sound 2 dB(A)| 65
Lubrication System
Type| Full Pressure
Oil Capacity (oz / L)| 78 / 2.31
Oil Filter (Quantity / Type)| 1 / Cartridge
Oil Brand| Schaeffer
Recommended Oil| 5W30 Full Synthetic
Electrical System
Ignition System| Variable Timing
Battery Quantity| 1
Battery Voltage (VDC)| 12
Battery CCA (Amps)| 540
Battery Grouping Size| 26 or 51
Starter Motor Voltage (VDC)| 12
Fuel System
Fuel Type| NG / LPV
Fuel Supply Line Inlet| 3/4” NPT
Recommended Fuel, Lower Heating Value M inim u m
(MJ/m 3 ****/ BTU/ft 3 )| NG: 34.3 / 904
LPV: 87.1 / 2338
Fuel Supply Pressure (mbar / in H2O)| NG: 9-17 / 3.5-7
LPV: 28-34 / 11-14
Fuel Consumption 3**
No Load, NG (BTU/hr)| 122,000
No Load, NG (ft 3 /hr)| 122
Half Load, NG (BTU/hr)| 206,000
Half Load, NG (ft 3 /hr)| 206
Full Load, NG (BTU/hr)| 323,000
Full Load, NG (ft 3 /hr)| 323
No Load, LP (BTU/hr)| 123,000
No Load, LP (ft 3 /hr)| 49
No Load, LP (gal/hr)| 1.40
Half Load, LP (BTU/hr)| 235,000
Half Load, LP (ft 3 /hr)| 94
Half Load, LP (gal/hr)| 2.60
Full Load, LP (BTU/hr)| 427,000
Full Load, LP (ft 3 /hr)| 171
Full Load, LP (gal/hr)| 4.70
Alternator Specifications
Alternator Type| Synchronous, Self-Excited, Rotating Field
Alternator Manufacturer| Briggs & Stratton
Frequency (Hz)| 60
Phase| 1
Insulation Rating (Class)| H
Designed Temperature Rise (°C)| 125
Bearing (Quantity / Type)| 1 / Sealed
Number of Poles| 2
Voltage Regulator| Brushed / Electronic
Motor Starting Capability (kVA)| 65.5 (35% Voltage Dip)
Total Harmonic Distortion (THD), NL to FL (%)| < 5
Controls/Instrumentation
Controller| GC-1032
Charger| Stand Alone
Starting| AMF or 2-wire
LED Digital Display| Yes
Alternator Frequency| Yes
Real Time Clock| Yes
Engine Hour Counter| Yes
Engine Runtime Scheduler| Yes
Controls/Instrumentation
Low Oil Pressure Shutdown| Yes
High Temperature Shutdown| Yes
Fault Code Display| Yes
Other Features
Battery Rack and Cables| Yes
Fuel Solenoid Valve| Yes
Integral Vibration Isolation| Yes
Oil Drain Extension| Yes
Operation and Installation Manual(s)| Yes
Enclosure| Aluminum
Enclosure Wind Speed Rating (mph)| 186
Accessories
Maintenance Kit| 6872
Oil Warmer| 6840
Fuel Regulator Warmer| 6845
Surge Protector| 6631
UPS| 6581
I n f oH ub ™ U ni v e rs al
– Ce llul ar| 6574
Limited Warranty 4
Warranty: Generator, Domestic & Canada (Parts **/ Labor /
Travel) — Years| 7
Warranty: Enclosure, Surface Rust and Corrosion (Parts / Labor
/ Travel) — Years| 1
Warranty: Enclosure, Rust Through (Parts / Labor /
Travel) — Years| 3
Warranty: Non-Emergency (Parts / Labor / Travel) — Years|
7yr or 1000 hr
Certifications
UL| Yes
cUL| Yes
CE| No
Massachusetts Plumbers and Gasfitters Listing| Yes
Weights & Dimensions**
Assembled Dimensions (Length x Width x Height) (in / mm)|
46.5 x 26.8 x 28.4 / 1181 x 681 x 721
Assembled Weight (lbs / kg)| 540 / 245
Packaged Dimensions (Length x Width x Height) (in / mm)|
48.8 x 30.5 x 50.5 / 1240 x 775 x 1283
Packaged Weight (lbs / kg)| 625 / 285
Outline and Pad Layout Drawing| 80104089
DIMENSION
- This generator is rated in accordance with UL (Underwriters Laboratories) 2200 (stationary engine generator assemblies) and CSA (Canadian Standards Association) standard C22.2 No. 100-14 (motor and generators).
- Per ISO 3744. Sound level measurement at other locations around generator may differ depending on installation, based on lowest microphone at 7m. Normal operation based on average household usage.
- Fuel consumption rates are estimated based on normal operating conditions. Generator operation may be greatly affected by elevation and the cycling operation of multiple electrical appliances — fuel flow rates may vary depending on these factors.
- See operator’s manual or energy.briggsandstratton.com for complete warranty details.
Briggs & Stratton has a policy of continuous product improvement and reserves
the right to modify its specifications at any time and without prior notice.
This standby generator is not for Prime Power applications.
Please visit energy.briggsandstratton.com for the latest information.
BS1306 – 04-18-24
BRIGGS & STRATTON
POST OFFICE BOX 702
MILWAUKEE, WI 53201 USA
Copyright © 2024 Briggs & Stratton. All rights reserved.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>