Avenir TRH10-90 Pura Heated Rail Installation Guide
- June 1, 2024
- Avenir
Table of Contents
Installation Guide &
Technical Specifications
VERSION: 2024.05
TRH10-90 Pura Heated Rail
Installation Guide
Pura Heated Rail – 24V
PLEASE FOLLOW THIS INSTALLATION GUIDE CLOSELY – Failure to do so could void
the warranty – This installation procedure has been carefully designed and
works very well However, it may be diferent to other products and your own
experience. The supplied ixings are specially designed for this product –
please do not substitute them!
COMMON ISSUES TO BE AVOIDED
- Install the supplied twin multi strand wire – do not use thicker wire.
- Install a separate wire for each rail back to the transformer – do not daisy chain.
- Avoid installing on grout lines – this is the weakest point of the tile.
- The transformer must be installed in a ventilated accessible location.
- The supplied low voltage wire is 2.5 meters, however this can be extended (5 meters Max).
In-Wall Kit TRCF-S| Transformer TRTR100-24V| Heated Towel Rail| Video
Installation Guide
---|---|---|---
|
| |
http://avenirdesign.com/IG-AVpura
SPECIFICATIONS
Voltage
24 Volts AC or DC (No Polarity)| Standards
EN/AS/NZ 60335.2.43
---|---
Material
Stainless Steel 304| Electrical Connection
Concealed Wiring
Finish
Polished, Brushed, PVD, Paint| Heating Method
Dry Internal Heating Element
Ingress Protection
IPX5 (Suitable for wet areas)| Required / Sold Separately
In-Wall Kit (TRCF-S) – per rail
AUSTRALIAN
MANUFACTURER|
---|---
HEATING TIME
30 MINUTES|
WARRANTY
10 YEAR|
A licensed electrician is required to carry out the installation of Heated
Towel Rails using the Concealed Wiring System (In-Wall Kit).
A timer should be itted to control the mains supply to the transformer, in
order to prolong the life of the heating elements, transformer and save
energy.
WARRANTY
The warranty covers products against defective materials and workmanship for a
period of 10 years from the date of purchase. Transformers are warranted for 5
years and labour is covered for the irst 12 months only. Please note this
warranty does not cover installation issues – if you are having diiculties
with installation we are happy to assist. For technical support please contact
service@avenir.com.au
Pura Heated Rail – 24V
VERSION: 2024.05
VARIATIONS
Heated Version | Depth | H1 (Fixings) | H2 (Overall) |
---|---|---|---|
TRH10-90 | 85mm | 600mm | 900mm |
TRH10-115 | 85mm | 850mm | 1150mm |
NOTE: Transformer (24V) and In-Wall Kits (1 per rail) required and sold
separatly
Recomended Spacing
160-400mm Typical 300mm (40mm Incriments)
1-3 Rails recomended per Bathroom