PLEASE READ THE INSTRUCTIONS CAREFULLY BEFORE COMMENCING ASSEMBLY
Live: Normally Brown/ Red Neutral: Normally Blue/ Black
If the external cord of this luminaire is damaged, it must be replaced by the manufacturer or a qualified person.
| NOT
SUITABLE FOR COVERING WITH THERMAL INSULATION.
---|---
| FOR CEILING
USE ONLY
Glare guard
CEILING TYPE
Ceiling lining secured directly to timber joists | Fire resistance periods to |
---|---|
Minimum 1 x 15 mm thick Type A or Type F gypsum wa l l boar d to EN 520 | 30 |
minutes
Minimum 2 x 12.5 mm thick Type F gyps u m Fir eli ne to EN 520| 60 minute
Minimum 3 x 12.5 mm thick Type F gypsum Fireline to EN 520| 90 minutes
These products are suitable to install in fire protected timber floor and ceiling systems which have previously been successfully tested for at least 30 minutes, 60 minutes or 90 minutes to EN 1365-2 : 2014
JOIST TYPES
Solid softwood or hard wood timber joists manufactured from strength grade C16
or greater, installed at centres not exceeding 600 mm