IMPORTANT : Read these instructions completely before attempting to install the accessory hail guard.
SAFETY CONSIDERATIONS
Installation and servicing of air-conditioning equipment can be hazardous due
to system pressure and electrical components. Only trained and qualified
service personnel should install, repair, or service air-conditioning
equipment.
Untrained personnel can perform the basic maintenance functions.
All other operations should be performed by trained service personnel. When
working on air-conditioning equipment, observe precautions in the literature,
tags and labels attached to the unit, and other safety precautions that may
apply.
Follow all safety codes. Wear safety glasses and work gloves.
Recognize safety information. This is the safety-alert symbol .
When you see this symbol on the unit and in instructions or manuals, be alert
to the potential for personal injury.
Understand the signal words DANGER, WARNING, and CAUTION. These words are used
with the safety alert symbol. DANGER identifies the most serious hazards which
will result in severe personal injury or death. WARNING signifies a hazard
which could result in personal injury or death. CAUTION is used to identify
unsafe practices which may result in minor personal injury or product and
property damage. NOTE is used to highlight suggestions which will result in
enhanced installation, reliability, or operation.
WARNING
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could cause personal injury or death.
Before beginning any modification on unit, always turn off main power switch
to unit and install lockout tag. Unit may have more than one power switch.
CAUTION
CUT HAZARD
Failure to follow this caution may result in personal injury.
Sheet metal parts may have sharp edges or burrs. Use care and wear appropriate
protective clothing, safety glasses and gloves when handling parts and
servicing units.
PACKAGE USAGE
See Tables 1-2 for package usage, as well as package contents and panel use location.
Table 1 — Package Usage
CARRIER MODEL USAGE
Model No. | Coil Type | Ref Tons | Hail Guard Pkg Part No. |
---|
Cooling
*38AUZ07** | RTPF | 6.0 | CALVHLGD005A00 |
---|---|---|---|
38AUZ(A/B)08 | RTPF | 7.5 | CALVHLGD005A00 |
38AUZ(D/E)08 | RTPF | 7.5 | CALVHLGD010A00 |
*38AUD(A/B)12**
*38AUZ12**
| RTPF| 10.0| CALVHLGD011A00
38AUD(T/U)12| RTPF| 10.0| CALVHLGD012A00
38AUD14 38AUZ14| RTPF| 12.5| CALVHLGD012A00
Heat Pump
*38AUQ07** | RTPF | 6.0 | CALVHLGD005A00 |
---|---|---|---|
38AUQ(A/B)08 | RTPF | 7.5 | CALVHLGD010A00 |
38AUQ(D/E)08 | RTPF | 7.5 | CALVHLGD010A00 |
*38AUQ12** | RTPF | 10.0 | CALVHLGD010A00 |
BRYANT MODEL USAGE
Model No. | Coil Type | Ref Tons | Hail Guard Pkg Part No. |
---|
Cooling
*569J07A/B** | RTPF | 6.0 | CALVHLGD005A00 |
---|---|---|---|
*569J08A/B** | RTPF | 7.5 | CALVHLGD005A00 |
*569J08G/H** | RTPF | 7.5 | CALVHLGD010A00 |
*569J12A/B**
*569J12D/E/F**
| RTPF| 10.0| CALVHLGD011A00
569J12T/U| RTPF| 10.0| CALVHLGD012A00
569J14A/B *569J14D/E**| RTPF| 12.5| CALVHLGD012A00
Heat Pump
*575J07A/B** | RTPF | 6.0 | CALVHLGD005A00 |
---|---|---|---|
*575J08A/B** | RTPF | 7.5 | CALVHLGD010A00 |
*575J08G/H** | RTPF | 7.5 | CALVHLGD010A00 |
*575J12A/B** | RTPF | 10.0 | CALVHLGD010A00 |
ICP MODEL USAGE
Model No. | Coil Type | Ref Tons | Hail Guard Pkg Part No. |
---|
Cooling
CAS072 | RTPF | 6.0 | CALVHLGD005A00 |
---|---|---|---|
*CAS091G/H** | RTPF | 7.5 | CALVHLGD010A00 |
CAS120/121 | RTPF | 10.0 | CALVHLGD011A00 |
CAS123/153 | RTPF | 10.0-12.5 | CALVHLGD012A00 |
CAS150/151 | RTPF | 12.5 | CALVHLGD012A00 |
Heat Pump
CHS072 | RTPF | 6.0 | CALVHLGD005A00 |
---|---|---|---|
*CHS091G/H** | RTPF | 7.5 | CALVHLGD010A00 |
CHS121 | RTPF | 10.0 | CALVHLGD010A00 |
Table 2 — Package Contents and Panel Use Location
HAIL GUARD PKG PART NO. | PACKAGE CONTENTS | PANEL USE LOCATION |
---|---|---|
CALVHLGD005A00 | (2) Hail Guards: | — |
(1) — 37.4 x 41.6 | Back | |
(1) — 37.4 x 30.6 | Left Side | |
(6) No. 10 x 1/2 Screws | — | |
(4) Grommets | — | |
CALVHLGD010A00 | (3) Hail Guards: | — |
(1) — 45.4 x 42.4 | Back | |
(1) — 45.4 x 30.6 | Left Side | |
(1) — 45.4 x 26.5 | Right Side | |
(8) No. 10 x 1/2 Screws | — | |
(8) Grommets | — | |
CALVHLGD011A00 | (2) Hail Guards: | — |
(1) 45.3 x 41.6 | Back | |
(1) 45.3 x 42.6 | Left Side | |
16 No. 10 Screws | — | |
4 Grommets | — | |
CALVHLGD012A00 | (3) Hail Guards: | — |
(1) 45.3 x 42.6 | Back | |
(1) 45.3 x 41.5 | Left Side | |
(1) 45.3 x 26.4 | Right Side | |
24 No. 10 Screws | — | |
8 Grommets | — |
GENERAL
Louvered hail guard packages are designed to protect the unit condenser coil from hail and general contact damage. Excessive damage to unit outdoor coils can result in diminished performance due to reduced air flow over the heat transfer surfaces.
IMPORTANT : Never drill or use screws through the top cover to secure hail guards. Coil damage could occur.
INSTALLATION
-
Verify the correct hail guard sizes are provided for the desired unit size. See Package Usage section.
-
Hold each hail guard panel in place ( see Fig. 1 and 2 ) and remove the screws at the base of the outdoor coil and the vertical side of the coil that line up with each of the hail guard panel holes to be installed. Save the screws.
Fig. 1 — Typical 2-Panel Hail Guard Installation (Uses 4 Grommets at 1 Corner Post)
Fig. 2 — Typical Third Panel Hail Guard Installation (Uses 8 Grommets, 4 on Each of 2 Corner Posts) -
Insert plastic grommets in the square holes of each corner post as shown in Fig. 3.
Fig. 3 — Grommets in Corner Post -
Align the hail guard panel with the respective section of the outdoor coil and insert the top edge of the hail guard panel under the lip of the top cover. (See Fig. 1, 2, and 4.)
-
Reinstall screws removed from Step 2. Using screws provided with kit, fasten panel at corner post ends through panel and into the installed grommets.
IMPORTANT : Never drill or use screws through the top cover to secure
hail guards. Coil damage could occur.
Fig. 4 — Hail Guard Panel into Top Cover (Use No Screws)
Customer support
Manufacturer reserves the right to discontinue, or change at any time,
specifications or designs without notice and without incurring obligations.