IMPORTANT : Read these instructions completely before attempting to install the accessory hail guard.

SAFETY CONSIDERATIONS

Installation and servicing of air-conditioning equipment can be hazardous due to system pressure and electrical components. Only trained and qualified service personnel should install, repair, or service air-conditioning equipment.
Untrained personnel can perform the basic maintenance functions.
All other operations should be performed by trained service personnel. When working on air-conditioning equipment, observe precautions in the literature, tags and labels attached to the unit, and other safety precautions that may apply.
Follow all safety codes. Wear safety glasses and work gloves.
Recognize safety information. This is the safety-alert symbol .
When you see this symbol on the unit and in instructions or manuals, be alert to the potential for personal injury.
Understand the signal words DANGER, WARNING, and CAUTION. These words are used with the safety alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies a hazard which could result in personal injury or death. CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation.

WARNING

ELECTRICAL SHOCK HAZARD
Failure to follow this warning could cause personal injury or death.
Before beginning any modification on unit, always turn off main power switch to unit and install lockout tag. Unit may have more than one power switch.

CAUTION

CUT HAZARD
Failure to follow this caution may result in personal injury.
Sheet metal parts may have sharp edges or burrs. Use care and wear appropriate protective clothing, safety glasses and gloves when handling parts and servicing units.

PACKAGE USAGE

See Tables 1-2 for package usage, as well as package contents and panel use location.

Table 1 — Package Usage

CARRIER MODEL USAGE

Model No. Coil Type Ref Tons Hail Guard Pkg Part No.

Cooling

*38AUZ07** RTPF 6.0 CALVHLGD005A00
38AUZ(A/B)08 RTPF 7.5 CALVHLGD005A00
38AUZ(D/E)08 RTPF 7.5 CALVHLGD010A00

*38AUD(A/B)12**

*38AUZ12**

| RTPF| 10.0| CALVHLGD011A00
38AUD(T/U)12| RTPF| 10.0| CALVHLGD012A00
38AUD14 38AUZ14| RTPF| 12.5| CALVHLGD012A00

Heat Pump

*38AUQ07** RTPF 6.0 CALVHLGD005A00
38AUQ(A/B)08 RTPF 7.5 CALVHLGD010A00
38AUQ(D/E)08 RTPF 7.5 CALVHLGD010A00
*38AUQ12** RTPF 10.0 CALVHLGD010A00

BRYANT MODEL USAGE

Model No. Coil Type Ref Tons Hail Guard Pkg Part No.

Cooling

*569J07A/B** RTPF 6.0 CALVHLGD005A00
*569J08A/B** RTPF 7.5 CALVHLGD005A00
*569J08G/H** RTPF 7.5 CALVHLGD010A00

*569J12A/B**

*569J12D/E/F**

| RTPF| 10.0| CALVHLGD011A00
569J12T/U| RTPF| 10.0| CALVHLGD012A00
569J
14A/B
*569J14D/E**| RTPF| 12.5| CALVHLGD012A00

Heat Pump

*575J07A/B** RTPF 6.0 CALVHLGD005A00
*575J08A/B** RTPF 7.5 CALVHLGD010A00
*575J08G/H** RTPF 7.5 CALVHLGD010A00
*575J12A/B** RTPF 10.0 CALVHLGD010A00

ICP MODEL USAGE

Model No. Coil Type Ref Tons Hail Guard Pkg Part No.

Cooling

CAS072 RTPF 6.0 CALVHLGD005A00
*CAS091G/H** RTPF 7.5 CALVHLGD010A00
CAS120/121 RTPF 10.0 CALVHLGD011A00
CAS123/153 RTPF 10.0-12.5 CALVHLGD012A00
CAS150/151 RTPF 12.5 CALVHLGD012A00

Heat Pump

CHS072 RTPF 6.0 CALVHLGD005A00
*CHS091G/H** RTPF 7.5 CALVHLGD010A00
CHS121 RTPF 10.0 CALVHLGD010A00

Table 2 — Package Contents and Panel Use Location

HAIL GUARD PKG PART NO. PACKAGE CONTENTS PANEL USE LOCATION
CALVHLGD005A00 (2) Hail Guards:
(1) — 37.4 x 41.6 Back
(1) — 37.4 x 30.6 Left Side
(6) No. 10 x 1/2 Screws
(4) Grommets
CALVHLGD010A00 (3) Hail Guards:
(1) — 45.4 x 42.4 Back
(1) — 45.4 x 30.6 Left Side
(1) — 45.4 x 26.5 Right Side
(8) No. 10 x 1/2 Screws
(8) Grommets
CALVHLGD011A00 (2) Hail Guards:
(1) 45.3 x 41.6 Back
(1) 45.3 x 42.6 Left Side
 16 No. 10 Screws
4 Grommets
CALVHLGD012A00 (3) Hail Guards:
(1) 45.3 x 42.6 Back
(1) 45.3 x 41.5 Left Side
(1) 45.3 x 26.4 Right Side
24 No. 10 Screws
8 Grommets

GENERAL

Louvered hail guard packages are designed to protect the unit condenser coil from hail and general contact damage. Excessive damage to unit outdoor coils can result in diminished performance due to reduced air flow over the heat transfer surfaces.

IMPORTANT : Never drill or use screws through the top cover to secure hail guards. Coil damage could occur.

Symbol

INSTALLATION

  1. Verify the correct hail guard sizes are provided for the desired unit size. See Package Usage section.

  2. Hold each hail guard panel in place ( see Fig. 1 and 2 ) and remove the screws at the base of the outdoor coil and the vertical side of the coil that line up with each of the hail guard panel holes to be installed. Save the screws.
    Installation
    Fig. 1 — Typical 2-Panel Hail Guard Installation (Uses 4 Grommets at 1 Corner Post)
    Installation
    Fig. 2 — Typical Third Panel Hail Guard Installation (Uses 8 Grommets, 4 on Each of 2 Corner Posts)

  3. Insert plastic grommets in the square holes of each corner post as shown in Fig. 3.
    Installation

    Fig. 3 — Grommets in Corner Post

  4. Align the hail guard panel with the respective section of the outdoor coil and insert the top edge of the hail guard panel under the lip of the top cover. (See Fig. 1, 2, and 4.)

  5. Reinstall screws removed from Step 2. Using screws provided with kit, fasten panel at corner post ends through panel and into the installed grommets.

IMPORTANT : Never drill or use screws through the top cover to secure hail guards. Coil damage could occur.
Installation
Fig. 4 — Hail Guard Panel into Top Cover (Use No Screws)

Customer support

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Catalog No. 04-53500418-01
Printed in U.S.A.
Form IIK-CALVHLGD05-01
3-24
Replaces: IIK-CALVHLGD05-01

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals