Aero-Fan V-12M Metal Inline Duct Ventilation Fan User Manual
- June 2, 2024
- Aero-Fan
Table of Contents
- Aero-Fan V-12M Metal Inline Duct Ventilation Fan
- OVERVIEW
- GENERAL INFORMATION
- SPECIFICATIONS
- OUTLINE DIMENSION
- INSTALLATION GUIDE
- CONTROL AEROFAN USING TOLMASTER HVDRO-X PRO
- TRANSPORT AND MANIPULATION
- SAFETY DURING INSTALLATION
- STARTING UP
- MAINTENANCE
- AERO-FAN COMPLIANCE
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Aero-Fan V-12M Metal Inline Duct Ventilation Fan
OVERVIEW
The 12-inch Metal lnline Duct Ventilation Fan Pro Model Is a compact and efficient fan designed to improve air circulation and ventilation in indoor spaces. With its powerful motor, it moves a significant volume of air, removing stale air, and humidity. Its versatile design allows easy installation in various duct systems, ensuring a fresh and comfortable environment. Multiple fans can be connected and speed-controlled together by using our FRC-1 fan controller.
GENERAL INFORMATION
Brand | Aero-Fan |
---|---|
Model | V-12M |
Exterior dimension | 255323300MM |
Weight | 14.44 lbs |
No. of Blades | 7 |
Rotating Direction | ccw |
SPECIFICATIONS
- Operating voltage range 100V~277VAC
- Rated current 3.8A (Max.)
- Rated input power 357W (Max.)
- Maximum air flow 1579 cfm
- Maximum static air pressure 814 Pa
- Operating temperature -4-140 ° F
- Mean Time To Failure (MTBF) 50000H (25 “C)
- Cells Lightning Protection 470VAC
- IP Rating IP44
OUTLINE DIMENSION
INSTALLATION GUIDE
- Unlock the clips to release the fan.
- Carefully remove the fan body from its position.
- Mark the hole positions for reference.
- Attach the mounting bracket securely.
- Reattach and secure the fan body.
- The fan installation process is now complete.
CONTROL AEROFAN USING TOLMASTER HVDRO-X PRO
Users have two options to connect AeroFan groups to the Hydro-X Pro (HCS-2) controller. Users can connect one fan group directly to the HCS-2 using the TrolMaster ECS-9 cable set without using the optional Smart Fan Remote (FRC-1) manual control module. Users can also choose to connect the FRC-1 to each group of fans AND to the HCS-2 by using TrolMaster ECS-7 and ECS-9 cable sets. The FRC-1 provides a simple/ manual speed control knob and digital display showing the fans speed. When the fan speed is adjusted using the FRC-1, it will remain for 30 minutes and then resume being controlled by the HCS-2. Whether you are using the FRC-1, or directly connecting your fans to the HCS-2 is up to the user. Aerofan provides multiple options and settings you can select from to customize how those fans will be operated. Multiple groups of fans can be connected and controlled using the HCS-2 controller and multiple FRC-1 s.
PRECAUTIONS
Please read this instructions booklet carefully before installing or starting
up the product. It contains important information on personal and user safety
measures to be followed while installing, using, and carrying out maintenance
work on the equipment. Once the product has been installed, please provide
this booklet to the end user.
Check that the fan is in perfect condition while unpacking. Any fault or
damage caused in transportation should be noted. Please make sure that the
apparatus coincides with the product you have ordered and that the
specifications on the fan fulfil your requirements.
WARNING! This product is for indoor use only. Do not attempt to repair or
use a damaged product. Do not immerse the product in water or subject it to
physical abuse. Inspect the product regularly for cable, plug, and casing
damage. Connect this product to a properly wired and grounded electrical
outlet.
- This fan must not be mounted on a suspended or structural wall, ceiling, or floor. This fan has thermal protection.
- Ce ventilateur ne doit pas etre monte sur un mur, un plafond ou un sol suspendu ou structural. Ce ventilateur est dote d’une protection thermique.
- TO Reduce The Risk Of Injury To Persons, Install Fan At Least 2.1 m (7 Feet) Above The Floor.
- Pour reduire le risque de blessures, installez le ventilateur a au mains 2,1 metres (7 pieds) du sol.
TRANSPORT AND MANIPULATION
- The packaging used for this apparatus has been designed to support normal transportation conditions. The fan should always be transported in its original packaging as not doing so could deform or damage the product.
- The product should be stored in a dry place in its original packaging, protected from dust and dirt until it is installed in its final location. Do not accept delivery if the apparatus is not in its original packaging or shows clear signs of having been manipulated in any way.
- Do not place heavy weights on the packed product and avoid dropping it.
IMPORTANT INFORMATION FOR THE SAFETY OF INSTALLERS AND USER
- Installation must only be carried out by qualified persons.
- Make sure that the installation complies with each country’s current mechanical and electrical requirements.
- Ventilators, or apparatus that include them, have been designed to move the air in the area at a rate stipulated on the specifications.
- This apparatus must not be used in explosive or corrosive atmospheres.
- The extractor outlet must not be connected to a duct used to exhaust smoke or fumes from any appliance that uses gas or any other type of fuel.
SAFETY DURING INSTALLATION
- Make sure there are no loose items near the ventilator, as they could run the risk of being sucked up by it. If it is going to be installed in a duct, check that it is clean of any debris that could be sucked up by the ventilator.
- When installing an apparatus, make sure that all the fittings are in place and that the structure that supports it is resistant enough to bear its weight at full functioning power.
- Before installing the apparatus, make sure the mains power supply is disconnected, even if the device is switched off.
- Check that the mains supply voltage and frequency values coincide with the stipulations on the specifications.
- Please follow the connections diagram for the electrical connections.
- If an earth connection is necessary, check that it is correctly connected.
- Ensure adequate thermal and overloading protection has been connected.
STARTING UP
Before starting up the machine, make sure that:
- The ventilator is well-secured, and the electrical connections have been carried out correctly.
- The safety devices have been adequately connected.
- No loose material or fitting remains can be sucked up by the ventilator. If the ventilator has been mounted in a duct, make sure it is clear of loose material.
- The earth fittings are adequately connected.
- The electrical safety devices are correctly connected, adequately adjusted and ready for use.
- The wire and electrical connection inputs are correctly sealed and watertight.
- The fan is installed so that the fan blade moves air in the correct direction.
- There are no abnormal vibrations.
- If the circuit protection device trips, the apparatus must be quickly disconnected from the mains supply. The whole installation should be carefully checked before trying to start up the unit again.
MAINTENANCE
- Before manipulating the ventilator, make sure it is disconnected from the main supply even if it has previously been switched off. Prevent the possibility of anyone else connecting it while it is being manipulated.
- The apparatus must be regularly inspected. These inspections should be carried out bearing in mind the machine’s working conditions, to avoid dirt or dust accumulating on the turbine or motors. This could be dangerous and perceptibly shorten the working life of the ventilator unit.
- While cleaning, great care should be taken not to damage the fan blades.
- All maintenance and repair work should be carried out in strict compliance with each country’s current safety regulations.
RECYCLING
EEC Standards, together with the responsibility we should assume with future
generations in mind, oblige us to recycle all the materials we can. Therefore,
please deposit all left-over material and packaging in their corresponding
recycling containers.
AERO-FAN COMPLIANCE
The product complies with all applicable requirements for the Restriction of
Hazardous Substances (RoHS) and Waste Electronic and Electrical Equipment
(WEEE). For Product Safety, EMC, RF, Energy, RoHS and WEEE information, go to
www.trolmaster.com. Maintenance is not required for product compliance.
Batteries, and electronic and electrical equipment should not be disposed of
with household waste. Wherever possible, they should be segregated and brought
to an appropriate collection point to enable recycling and avoid potential
impacts on the environment and human health. For more information, contact
your local authorities or place of purchase.
AERO-FAN LIMITED HARDWARE PRODUCT WARRANTY A SUMMARY
Aero-Fan warrants that its hardware product shall be free from defects in
materials and workmanship for the length of time identified on your product
package beginning from the date of the original retail purchase. See
www.trolmaster.com/News, Warranty for specific warranty information about your
product and procedures to act on a warranty claim.
Aero-Fan’s entire liability and your exclusive remedy for any breach of
warranty shall be, at Aero-Fan’s option, to repair or replace a functional
equivalent of the product, or to refund the price paid, if the hardware is
returned to the point of purchase or such other place as Aero-Fan may direct
along with a receipt. Warranty protections are in addition to rights provided
under local consumer laws and may vary among countries. See full warranty
information to know your consumer rights and the additional protections
provided by this product warranty. 3-year warranty for all products except a
year warranty for sensor probes from the purchase day. This warranty gives you
specific legal rights, and you may also have other rights, which vary from
state to state.
Read User Manual Online (PDF format)