Ambiane HP111 Pendant Remote Lighting Instruction Manual

June 2, 2024
Ambiane

Ambiane HP111 Pendant Remote Lighting

Ambiane-HP111-Pendant-Remote-Lighting-PROCUT

Specifications

  • Product Name: AMBIANE HP111 Pendant Remote
  • Manufacturer: ROBE Lighting S. r. o.
  • Model Number: HP111
  • Version: 2.0 / 1_2023
  • Country of Origin: Czech Republic

Product Usage Instructions

Step 1: Mounting to Lower Ceiling

  1. Fasten the Ceiling Plate M6i to the lower ceiling with a suitable fastener.
  2. Screw the Spherical Cap (with the Hanging Wire) to the CeilingPlate. Use thread glue LOXEAL 5503.

Step 2: Control Unit Installation

Fasten the control unit on the ceiling using two holes in the
housing.

Step 3: LED Unit Supply Cable Connection

  1. Shorten the power/data cable of the LED unit to the required length.
  2. Strip lengths of LED unit’s cable for wiring connection.
  3. Pull the LED unit’s cable through a prepared hole in the ceiling and secure it. Install a terminal block on the cable and connect it to the control unit.

Step 4: Primary Power Connection
Install the terminal block to the power cable and connect it to the primary power socket of the control unit.

Step 5: Secondary Power Connection 48V (PSU Scope others )
Install the terminal block on the Secondary power cable and connect it to the Secondary power socket of the control unit.

Step 6: Data Cables Connection (DMX or DALI)
Install terminal blocks on DMX or DALI cables and connect them to the control unit.

Step 7: Adjusting the Hanging Wire Length

  1. Install terminal blocks on DMX or DALI cables and connect them to the control unit.
  2. Press down the pin on the wire connector for length adjustment.
  3. Press down pins on the hanging wire anchors for length and downward orientation adjustment.

INSTALLATION INSTRUCTIONS

AMBIANE HP111 PENDANT REMOTE

WARNING: The unit must be installed by a qualified electrician under all national and local electrical and construction codes and regulations.

STEP 1: MOUNTING TO LOWER CEILING

Ambiane-HP111-Pendant-Remote-Lighting-FIG-2

  1. Fasten the Ceiling Plate M6i to the lower ceiling with a suitable fastener.
  2. Screw the Spherical Cap (with the Hanging Wire) to the Ceiling Plate. Use of thread glue LOXEAL 5503 is recommended.
  3. Drill the hole Ø8mm in the lower ceiling for the LED unit supply cable. If you wish to have the LED unit supply cable parallel with the hanging wire, the distance between the hanging wire and the LED unit supply cable should be 60mm.

STEP 2: CONTROL UNIT INSTALLATION

Ambiane-HP111-Pendant-Remote-Lighting-FIG-4

STEP 3: LED UNIT SUPPLY CABLE CONNECTION

  1. Shorten the power/data cable of the LED unit to the required length. Strip these lengths of the LED unit‘s cable for wiring connection.

LED Unit Connection

Fasten the control unit on the ceiling using two holes in the control unit’s housing.

Ambiane-HP111-Pendant-Remote-Lighting-FIG-6

Pull the LED unit‘s cable through the prepared hole in the ceiling and secure it above the ceiling. Install a terminal block on the cable and connect it to the control unit.

STEP 4: PRIMARY POWER CONNECTION

Ambiane-HP111-Pendant-Remote-Lighting-FIG-15

Install the terminal block to the power cable (from Ambiane Power Rack or Ambiane Power HP) and connect it to the Primary power socket of the control unit.

STEP 5: SECONDARY POWER CONNECTION 48V (PSU SCOPE OF OTHERS)Ambiane-
HP111-Pendant-Remote-Lighting-FIG-9

Install the terminal block on the Secondary power cable and connect it to the Secondary power socket of the control unit.

STEP 6 DATA CABLES CONNECTION (DMX OR DALI)Ambiane-HP111-Pendant-
Remote-Lighting-FIG-10

Install terminal blocks on DMX or DALI cables and connect them to the control unit.

STEP 7: ADJUSTING THE HANGING WIRE LENGTH

  1. Press down the pin on the wire connector for length adjustment.
  2. Press down pins on the hanging wire anchors for length and downward orientation adjustment.

FAQ

  • Q: Can the AMBIANE HP111 Pendant Remote be controlled by both DMX and DALI?
    • A: Yes, the fixture can be controlled by both DMX and DALI. Ensure switch 11 is in the OFF position for DMX control.