Instruction Manual INSTALLATION INSTRUCTION
PRODUCT DESCRIPTION
Thermostatic Shower Mixer – –
with 38°C Safety Button – give you a enjoyable shower experience
-
38°Cntelligent Thermostat
When you set the temperature, the intelligent thermostat cartridge which can accurately adjust the proportion of hot and cold water, it can effectively prevent scalding. -
High Quality Solid Brass
The main body of shower mixer is made of corrosion-resistant solid brass, lead-removing process, durable and ensure healthy water. -
Multi-layer Shiny Chrome Finish
Multi-layer electroplating is mirror-like, resistant to corrosion and rust, easy to clean, wear-resistant and durable.
Warm Tips:
To ensure that every product is qualified before it leaves the factory, our
products are water tested. Soltis normal for a little water to remain in the
tap.
AFTER SALES
- 24-hour rapid response to after-sales service.
- If your product does not work correctly, please refer to this manual for fault diagnosis, check that it s installed and commissioned in accordance with our instructions
- You can contact us via Amazon email for after-sales service.
TECHNICAL INFORMATION
Material | Brass+Plastic(handle) |
---|---|
Finish | Chrome |
Safety Stop | 38°C |
Inlet Size | G1/2″ |
Outlet Water Temperature Range | 20-50°C |
Recommended Water Pressure | 1-5bar |
Distance Between Hot/Cold Inlets | 150mm(+15mm) |
PRODUCT BREAKDOWN STRUCTURE
INSTALLATION STEPS
- wrap PTFE tape to the offset connectors and fix to the wall pipe.(Inlet pipework should be at 150mm pipe centers.)
- fix the ornament covers to the offset connectors.
- keep at the same level
- put the gaskets into the hex nuts, then fix the shower mixer to the offset connectors.
Note! Connections are Hot-left, Cold-right.
This is very important as this product does no tallow for reverse.
FAULT ANALYSIS AND TROUBLESHOOTING
No. | Fault Phenomenon | Cause/ Rectification |
---|---|---|
1 | Water too hot or too cold | 1.1nlets are reversed – Check connections. |
2.Filters are blocked – Check filters.
3.Water supply is not balanced – Check supply pressure is balanced.
2| Poor temperature control| 1.Contact seller customer service for I
replacement thermostatic valve cartridge. (It is reasonable for the deviation
value of the setting water temperature and actual water temperature to bet 3°C
)
3| Low flow| 1.Filters are blocked – check filters
2.1solation valve is closed – check valves.
3.5upply pressure too low – check the supply is above 0.5 bar.
4| Water is leaking/Cannot turn off| 1.Seals worn or damaged
– Request seller customer service.
OS| Water flows from both sides when switching from shower to bath| 1.Divertor
leaked – Request seller customer service for renew divertor replacement.
NOTE!
Connections:
- Hot – Left (side nearest flow control). Identified with a RED mark
- Cold – Right (side nearest temperature control). Identified with a BLUE mark
- Shower Valve Outlet (connect shower hose).
Suitable Plumbing Systems
- Gravity Fed: The thermostatic mixer must be fed from a cold water cistern (usually fitted in the loft space) and a hot water cylinder (usually fitted in the airing cupboard) providing nominally equal pressures.
- Gas Heated System: The thermostatic mixer can be installed with a combination boiler.
- Unvented Mains Pressure System: The thermostatic mixer can be installed with an unvented, stored hot water system.
- Mains Pressurized Instantaneous Hot Water System: The thermostatic mixer can be installed with systems of this type with balanced pressures.