MEDIFY MA-22 Air Purifier User Manual

May 15, 2024
Medify

MEDIFY MA-22 Air Purifier

MEDIFY MA-22 Air Purifier

IMPORTANT SAFETY INSTRUCTIONS

IN ORDER TO AVOID ANY DAMAGE TO YOU, OTHERS OR PROPERTY, FOLLOW THE FOLLOWING SAFETY PRECAUTIONS:

IF THE POWER CORD OR UNIT DOES NOT WORK, CONTACT MEDIFY CUSTOMER SERVICE IMMEDIATELY.

READ ALL INSTRUCTIONS BEFORE USING.

WARNING – TO REDUCE THE RISK OF BURNS, FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS:

  • To reduce the risk of fire or electrical shock, DO NOT use this fan with any solid-state speed control device .
  • This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of electrical shock, this plug is intended to fit in a polarized outlet only one wa . If the plug does not fit fully in the outlet, reverse the lug. If it still does not fit, contact a qualified electrician. Do not attempt to defeat this safety feature
  • DO NOT touch power plug with wet hands. Wet hands can cause an electrical shock to occur. Never touch with wet hands.
  • Turn off the power before cleaning machine. Unplug before cleaning to avoid electrical shock or unit turning on accidentally.
  • DO NOT take apart or modify unit without authorization. Taking apart or modifying it without authorization may cause personal injury or unit malfunction.
  • DO NOT put bars or metal products nearby air outlet or openings. If metal bars touch inside of machine it can cause electrical shock.
  • DO NOT damage power line and socket. Do not bind wires when you use the unit. It may cause electrical shock, short circuit, or fire if you use broken wires Forbidden to cut, scratch, refit, distort, twist or pull power lines. DO NO put any heavy products on top of wires or sockets.
  • Regularly clean power plug. Do not allow dust to accumulate on power plug. This can damage insulation and cause a fire accident to happen. Pull out the power plug and clean with dry cloth (do not use a wet cloth). If you are not planning to be used this machine for any extended period of time, unplug it for safety reasons.
  • Prohibited use beyond power. Can only use a 220v unit with a 220v power supply. Can only use a 110v unit with a 110v power supply. You can break or ruin the circuit boards if you plug a 110v plug into a 220v power supply.
  • Please insert the plug completely into the power socket before starting the unit. If not, this may cause an electrical shock and overheating, or even a fire accident to occur . Do not use damaged plug or loose socket.
  • Keep machine dry. Or else it may cause an electrical shock or a fire accident to happen
  • Keep machine away from volatile substances or flammable items. This could cause a fir
  • DO NOT use unit in greasy area. This machine should not be used as ventilating or air evacuating equipment.
  • DO NOT use unit in high temperature or humid conditions. These situations may cause current damage, electrical shock, or even a fire accident to happen
  • DO NOT use the unit in the room with fumigation type pesticides. Chemical residue could be accumulated inside the machine and then released, causing harm. The room should keep ventilated thoroughly after you use insecticide and then start to use air purified .
  • If you use the unit in a room with an electric heater, ensure proper ventilation. Otherwise, there could be a buildup of carbon monoxide, which can cause serious harm or death. The air purifier will NOT remove carbon monoxide from the ai .
  • DO NOT use solvents like benzene, diluent, etc. to clean the air purified . This can cause the unit to break, to become damaged, or short circuit, which can lead to an electrical shock or even a fire accidents to happen
  • Be careful when removing the plug from the power socket. DO NOT pull wires which may cause short circuit or damage to wires, to avoid possible fire accident or electrical shock
  • BEFORE USING THIS PRODUCT, PLEASE MAKE SURE TO REMOVE THE PLASTIC COVERING FROM ALL FILTERS.

SAVE THESE IMPORTANT INSTRUCTIONS FOR EASY REFERENCE.

TECHNICAL DATA

  • Voltage: 120 V AC 60Hz
  • Rated power: 38 W
  • Noise level: 53 dB(A)
  • Unit dimensions: 12.2″H x 8.07″W x 8.07″D
  • Unit weight: 5.2 lbs.
  • EPA Est.87627-CHN-001
  • Integrated Energy Factor (IEF): 2
  • Annual Energy consumption (KW-Hours/ year): 223

STANDARD COVERAGE

139 sq ft every 15 min(4 ACH)
278 sq ft every 30 min(2 ACH)
555 sq ft every 60 min (1 ACH)

Clean Air Delivery Rate


Smoke

| Pollen| Dust| PM2.5

74 CFM

| 75 CFM| 82 CFM|

78 CFM

  • AIR PURIFER

  • FILTER

  • BASE

FILTER PURIFICATION

  1. PRE FILTER
    Removes hair, fibers, and large particles like dander.

  2. TRUE HEPA H13 FILTER
    The high-efficiency H13 TRUE HEPA filter is tested to remove 99.9% of particles down to 0.1 microns.
    This higher grade of HEPA filter catches pollen, dust mites, and other tiny airborne particles you can’t see.

  3. ACTIVATED CARBON FILTER
    Substantial carbon filter with carbon pellets removes odors and smoke.
    Filter Purification

CONTROL PANEL

Control Panel

HOW TO USE

This air purifier is used to remove airborne contaminants from the indoor air in a particular area which could be potentially harmful to breathe. PLACEMENT OF AIR PURIFIE

  • Do not obstruct air intake or clean air outlet.
  • To ensure sufficient air circulation, make sure there is a 20 inch or 50 cm distance between air inlet and wall or nearby furniture. This will ensure enough ventilation and high efficiency .

POWER ON/OFF

Press it to turn on/off the unit. POWER indicator will turn on, the unit will turn onto Speed 1.

CONTROL FAN SPEED

Press above button to select speed from the following options: S, 1, 2, 3. Speed 1 is slow speed.
Speed 2 is medium speed. Speed 3 is fast speed. S is Sleep mode.

STANDBY MODE

Insert the plug of unit into a power source. Unit lights will turn on. After one second, air purifier is in standby
mode.

TIMER
Timer, set to 1H, 2H, 4H, 8H.

CHILD LOCK FUNCTION
Child Lock function, press and hold for 3 seconds to activate it; to deactivated it, press and hold for 3 secs.

FILTER REPLACEMENT

LIGHT INDICATOR TO REPLACE THE FILTER
The light indicator will show when it is time to replace the True HEPA H13 filter based on the air purifies hours of use.

INSTALLING FILTER SET
All filters must be used together . Please disassemble filters according to the following instructions. Reinstall the filters according

1. Place the machine in a dry location on a flat surface

2. Rotate the base clockwise

3. Pull the base downwards to reveal the filters

Take out the filter to clean or replace with a new one.
4. Re-attach base at the bottom of the unit (with filters inside). Rotate counter-clockwise to secure base.

ATTENTION

Remove all plastic packaging from the filter before installing it.
DO NOT run the air purifier if there is no filter installed.
Please be careful when installing the back cover. Watch your hands.

To remove the base, turn it clockwise as shown in Figure A.
To secure the base, rotate it counter-clockwise as shown in
Figure B.

CLEANING AND MAINTENANCE

Please make sure to pull out the power plug before cleaning the unit. Do not immerse machine in water or any other liquid. Do not use abrasive, corrosive or flammable products to clean any parts of the unit. The unit uses composite filters, so filters cannot be washed

LONG TIME IDLING
Do not leave unit plugged in for an extended period of time when not in use. Place machine in a dry and well-ventilated place when not in use for extended period of time.

CLEANING THE AIR PURIFIER
Clean the air purifier regularly to prevent the dust accumulation

  1. Use soft and dry cloth to remove the dust from the air purified.
  2. Use soft and dry cloth to clean the outlet and inlet of the air purified.

FILTER REPLACEMENT

LIGHT INDICATOR TO REPLACE THE FILTER
The unit will remind the user when the filter needs to be replaced. The filter indicator light will let you know when you have reached that time. Suggested frequency of replacing the filter set: 3-4 months

Please turn off unit and pull out power plug before replacing the filters. Can use a brush or dust collector to remove surface level dust from the filters, but do not press hard on the filter material. The unit use composite filters. These filters CANNOT be washed

TROUBLESHOOTING

PROBLEM POSSIBLE CAUSE SOLUTION
Unit will not operate Unit is not plugged in Pull out plug and plug it

back in
Incorrect power plug or wire| Contact customer service
Fan does not work| Machine doesn’t turn on| Plug in and turn on
Motor is not working| Contact customer service
Machine is on uneven ground| Move to even and flat groan
Loose or foreign particles inside| Contact customer service
Filter packaging is not removed| Remove packaging of every filet
Motor is loose| Contact customer service
Performance issues| The filter needs to be replace| Replace the filter with genuine Modify Air replacement filters for the best performance
Air intake or outlet blocked| Contact customer service
Filter plastic not removed| Remove packaging and then use
Not enough space surrounding the air purified| Ensure 20 in distance between two sides of air intake and that distance to air outlet is not less than 10 cm
Lack of filter or filter is no properly installed| Make sure all the filters are placed in order in accordance with instructions
Coverage area questions| Check whether the room area is in accordance with coverage area

WARRANTY INFORMATION

If you have any additional questions, please contact customer service. All names and trademarks are property of Modify Air. Our company reserves the right to change the product at any time, without prior notice, and the company has no obligation to adjust any products supplied earlier. Please refer to the detailed warranty terms below. To register for the lifetime warranty, please fill out the attached form and mail it to:

Medify Air
150 E. Palmetto Park Road, Suite 200
Boca Raton, Florida 33432

Or complete the lifetime warranty registration available on our website (preferred method):

www.medifyair.com

LIFETIME WARRANTY

Medify guarantees your Medify Air Purifier to be free of defects in material or workmanship for a lifetime period, provided you have completed and returned your warranty registration to Medify Air within the first 30 days of purchase, and that the filters are replaced with original and genuine Medify Air replacement filters at least once every three to four (3-4) months or after 2,500 hours of use. Within the first 30 days, Medify Air will replace the defective unit at no charge to you and reimburse you for any shipping charges. After 30 days, Medify Air’s obligation and liability under this Lifetime Warranty is dependent on your use of our genuine filters, purchased on our website or from our authorized resellers, which can be found on our website. Prohibited use beyond power. Can only use a 220v unit with a 220v power supply. Can only use a 110v unit with a 110v power supply. You can break or ruin the circuit boards if you plug a 110v plug into a 220v power supply.

Our Lifetime Warranty remains in effect as long as:

  1. You submit your warranty registration to Medify Air within 30 days of purchase.
  2. You change filters with genuine and original Medify Air replacement filters at least once every three to fou (3-4) months or after 2,500 hours of use (whichever comes first)
  3. You use a proper power supply based on voltage: 110-120 V (North America & Japan) or 220-240 V (all other regions).
  4. There is no evidence of tampering, mishandling, neglect, accidental damage, modification, and/or repair done to the Medify Air purifier by anyone other than authorized Medify Air service personnel
  5. Your air purifier is operated in accordance with the provided instructions

Customer Support

This Lifetime Warranty is provided by:
Medify Air
150 E. Palmetto Park Road, Suite 200
Boca Raton, Florida 33432

www.medifyair.com
info@medifyair.com
888-258-1008 Please visit our website for details on efficacy test data:
medifyair.com/pages/reports

References

Read User Manual Online (PDF format)