MARDER SCHRECK 16275 Marten Repellent Device Ultrasound Instruction Manual
- May 15, 2024
- MARDER SCHRECK
Table of Contents
- 16275 Marten Repellent Device Ultrasound
- PROPER USE OF THE PRODUCT
- SCOPE OF DELIVERY
- SPECIFICATIONS
- SAFETY NOTES
- EXPLANATION OF SYMBOLS
- OPERATING INSTRUCTIONS
- MAINTENANCE AND CARE
- NOTES REGARDING ENVIRONMENTAL PROTECTION
- CONTACT INFORMATION
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
© EAL GmbH, 16275, 09. 2023
Art. no. 16275
Marten repellent device ultrasound,
battery-operated
Operating instructions
16275 Marten Repellent Device Ultrasound
WARNING
Read the operating instructions through carefully prior to initial use and
observe all of the safety notes!
Not observing such may lead to personal injury,damages to the device or your
property!
Store the original packaging, the receipt and these instructions so that they
may be consultedat a later date! When passing on the product, please include
these operating instructions aswell.
Please check the contents of package for integrity and completeness prior to
use!
PROPER USE OF THE PRODUCT
The battery-operated ultrasound device is designed to protect cars and
caravans from marten damage.
This device is not designed to be used by children or persons with limited
metal abilities or without experience and/or lack of required specialist
knowledge. Keep children away from the device.
The device is not designated for commercial use.
Utilisation according to the intended purpose also includes the observance of
all information in these operating instructions, particularly the observance
of the safety instructions. Any other utilisation is considered to be contrary
to the intended purpose and may
lead to material damages or personal injuries. EAL GmbH assumes no liability
for damage resulting from improper use.
SCOPE OF DELIVERY
1 x Marten repellent device ultrasound, battery-operated
2 x Batteries, AA
1 x Operating instructions
SPECIFICATIONS
Operational voltage: | 3 V |
---|---|
Frequency: | 23 kHz ± 10 % pulsing |
Power consumption: | 0.4 mA |
Reflection angle: | 160°, effective |
Loudspeaker: | Piezo callotte |
Function check: | max. 95 dB ± 15 % |
Acoustic pressure: | Flashing LED |
Battery type: | AA, mignon cell, 1.5 V |
Dimensions: | approx. 125 x 59 x 22 [mm] |
Weight: | approx. 0.065 kg (without batteries) |
SAFETY NOTES
- The warning triangle labels all instructions important to safety. Always follow these otherwise you could injure yourself or damage the device.
- Children may not play with the device.
- Cleaning and user maintenance may not be carried out by children without supervision.
- Do not treat packaging material carelessly. This may become a dangerous plaything for a child!
- Only use this product as intended!
- Do not manipulate or dismantle the device!
- For your own safety, only use accessories and spare parts that are stated in these Instructions or are recommended by the manufacturer!
EXPLANATION OF SYMBOLS
**** Complies with EC directives
Labelled electrical products may not be disposed of in the household waste
OPERATING INSTRUCTIONS
6.1 OVERVIEW
-
Indicator light
-
Loudspeaker opening
-
Enclosure screw
-
Fixing lug
6.2 PREPARATION
Clean the engine compartment thoroughly or use the primer spray for removing
marten scent marks, item number: 16265 before installing the ultrasound marten
repellent device. We also recommend cleaning the underside of the vehicle and
the site on which it stands.
6.3 INSERTING THE BATTERIES
Remove the six cross-headed screws (Position 3 in the overview) on the rear of
the device. Remove the lid. Insert the batteries into the battery compartment,
fig.2, pay attention to ensure that poling is correct. Replace the lid and
screw firmly into place using the six cross-headed screws. The device is now
in operation, the control light (position1 in the overview) on the front
flashes.
Ultrasound cannot be perceived by humans. Use the indicator light as a guide when checking the function.
6.4 ASSEMBLY
Install the ultrasound marten repellent device in such a way that the sound is
able to spread freely, similar to the light cone of a torch. Select a
position, fig. 3, that is as high up as possible in the engine compartment to
prevent the risk of influence from dirt and water. Ensure a good distance is
left between the device and heat sources such as the exhaust, catalytic
converter and rotating parts. Make sure that the fuse in the connecting cable
is easily accessible. In very tight engine compartments, it may be necessary
to install multiple martin repellent devices since the ultrasound can be
shielded considerably by obstacles.
MAINTENANCE AND CARE
Check regularly whether the indicator light is flashing. If this is not the case, replace the batteries. Otherwise, the ultrasound unit is maintenance- free when used as intended.
NOTES REGARDING ENVIRONMENTAL PROTECTION
Do not dispose of electrical devices with the household waste! Electrical and
electronic scrap must be collected separately and disposed of in an
environmentally responsible manner for recycling. Please contact your
community or city administration regarding disposal options for electrical and
electronic scrap.
At the end of their lifetime, used batteries and battery packs are not to be
disposed of in the household waste – or negligently in the environment. Hand
in used device batteries/battery packs to the collection points at the store
(dealer). This makes a considerable contribution towards protecting our
environment. Some communities may also collect used batteries/battery packs
via mobile stations or recycling centres.
CONTACT INFORMATION
EAL GmbH
Otto-Hausmann-Ring 107
42115 Wuppertal, Germany
+49 (0)202 42 92 83 0
+49 (0) 202 42 92 83 – 160
info@eal-vertrieb.com