AXIOMATIC AX141550 Gigabit Automotive Ethernet Gigabit Ethernet Converter User Manual

May 15, 2024
AXIOMATIC

AXIOMATIC AX141550 Gigabit Automotive Ethernet Gigabit Ethernet Converter

AXIOMATIC-AX141550-Gigabit-Automotive-ethernet-Gigabit-Ethernet-Converter-
product

GENERAL INFORMATION

Introduction

The Ethernet to Automotive Ethernet Gigabit Converter, AX141550, has both Ethernet and Automotive Ethernet Physical Layer transceivers (1000BASE-T and 1000BASE-T1 PHYs) that are used to achieve bidirectional communication. The converter supports configuration via RS232 to update the speed (100/1000Mbps) as well as to set the Automotive Ethernet PHY to Master/Slave mode. The AX141550 does not store any packets and does not modify or filter any packets.
By default, both PHYs (Ethernet and the Automotive Ethernet) communicate at a speed of 1000Mbps, and the Automotive Ethernet is configured to work in Slave mode. Status LEDs provide information on Power, Connection Links, and Activity.

The power LED will be ON as soon as power is supplied to the converter. The Power LED is used to verify whether power is supplied to the converter. If the proper power supply level is connected to the converter, the Power LED will be ON; indicating the converter is ON. The AX141550 is continuously monitoring the status of Link and Activity by reading the registers of Ethernet PHYs and will show the real-time update of Ethernet and Automotive Ethernet Link and Activity on Link and Activity LEDs, respectively. The screenshots of Tera Term in this user manual are intended for reference purposes only.

Functional Block Diagram of the Converter

AXIOMATIC-AX141550-Gigabit-Automotive-ethernet-Gigabit-Ethernet-Converter-
fig- \(1\)

CONNECTORS
The converter has two connectors.

M12 8-pin (P/N: 1441817)
The M12 8-pin connector is used for the Ethernet 1000BASE-T connection. The mating harness P/N is: AX070535.

Table 1 M12 8-pin connector (P/N:141817)

AXIOMATIC-AX141550-Gigabit-Automotive-ethernet-Gigabit-Ethernet-Converter-
fig- \(2\)

M12 8-pin (P/N: 1441804)
The M12 8-pin connector is used for power supply, RS-232, CAN, and Automotive Ethernet. 1 Phoenix Contact M12 8-pin connector (A-coded). The mating harness PN is: AX070537

Table 2 M12 8-pin connector (P/N:1441804)

AXIOMATIC-AX141550-Gigabit-Automotive-ethernet-Gigabit-Ethernet-Converter-
fig- \(3\)

CONFIGURATION USING RS-232
RS-232 configuration is password-protected and can be accessed through Tera Term or other serial terminals. Tera Term Serial Port setup is shown below. The default configuration menu includes Project details like Project Name, Version number, Release Date, Part Number, and Serial Number. The menu has 8 options as attached in the picture below. To view or change the configuration, please enter the password: “AX141550”.

AXIOMATIC-AX141550-Gigabit-Automotive-ethernet-Gigabit-Ethernet-Converter-
fig- \(4\)

To view or change the configuration, please enter the password: “AX141550”.

AXIOMATIC-AX141550-Gigabit-Automotive-ethernet-Gigabit-Ethernet-Converter-
fig- \(5\)

Show Configuration Parameter

****Press ‘1’ to see the Configuration parameters. This option will show the Serial Number, Converter Mode, Converter Speed, and Log Timing. If the converter Mode is “Master”, it shows that Automotive Ethernet PHY is configured to work as Master. If the converter Mode is “Slave”, it shows that Automotive Ethernet PHY is configured to work as Slave. Speed shows the speed of both PHYs. Log Timing is used to see the Power and (Ethernet and Automotive Ethernet) Link logs over RS-232. Logs are used for debugging and testing purposes. Log Timing does not affect the Converter’s working and Master-Slave or Speed configuration of PHYs.

Change Configuration Parameters
Press ‘2’ to change the configuration parameters. This option gives the choice to change the Serial Number, Mode, Speed, and Log Timing. Enter the name of the parameter that needs to be changed other than the Serial Number. The option to change the Serial Number is not available for field updates. Enter the name from the list given on the Tera term window. i.e., “Mode”, “Speed”, or “LogTiming”. Any string entered other than given on the Tera Term window will be discarded by the Converter, as the string is case-sensitive. i.e., to change Speed, typing “speed” will have no effect as the converter is expecting for the string “Speed”. Changing the Speed will change the Speed of both Ethernet and Automotive Ethernet PHYs.

AXIOMATIC-AX141550-Gigabit-Automotive-ethernet-Gigabit-Ethernet-Converter-
fig- \(7\)

Type “Mode” to change the mode. Press ‘1’ to configure the Automotive Ethernet PHY in Slave mode or ‘2’ for Master mode. Changing the Mode will change the Mode of Automotive Ethernet PHY only, as normal Ethernet PHY has Auto- negotiation enabled to negotiate the Mode. Log Timing could be configured to have a value between 1 Second to 10 Seconds. The Master/Slave and Speed settings will be saved. So, after reset or power cycle, the converter will have the last configured Speed, Mode, and Log Timing. Enter the name of the parameter: “Enter string Mode to change Mode”. To change the Speed or Log Timing Follow the same method. As shown in the picture below.

AXIOMATIC-AX141550-Gigabit-Automotive-ethernet-Gigabit-Ethernet-Converter-
fig- \(8\)

Set Default Configuration Parameters

Press ‘3’ to set the default configuration parameters. This option will set the Mode and Speed to Slave and 1000Mbps respectively, as the default mode is Slave mode and the default speed is 1000 Mbps. The log timing will be also changed to the default value, which is 1 Second. The configuration settings will be saved. So, after reset or power cycle, the converter will have the last configured Speed, Mode, and Log Timing.

Erase EEPROM
Press ‘9’ to Erase EEPROM. Erasing the EEPROM will erase the Firmware Flags and Firmware Configurations (Mode/Slave and Log Timing) stored in EEPROM. So, in the next power cycle, the firmware will store default Configuration parameters and Firmware Flags. This is useful while doing the Firmware Version update, to erase the old version number stored in EEPROM and save the new version number.

Temperature of Ethernet PHYs
Press ‘c’.to read the internal temperature of both the PHYs in Celsius.

AXIOMATIC-AX141550-Gigabit-Automotive-ethernet-Gigabit-Ethernet-Converter-
fig- \(9\)

Start/Stop Logs
Press ‘s’ to start or stop the debug logs. Starting the debug logs will print the supplied voltage to the Unit and Ethernet and Automotive Ethernet Link status on Tera Term, as per the Log Timing configuration. i.e., If the Log Timing is 1 Second, the converter will print the debug logs every second. Pressing ‘s’ again will stop the logs.

AXIOMATIC-AX141550-Gigabit-Automotive-ethernet-Gigabit-Ethernet-Converter-
fig- \(10\)

Reboot the Controller
Press ‘r’ to reboot the converter. This will simply restart the converter. Rebooting the converter will not change the Mode or Speed of the converter. This option is useful to restart the converter through Tera Term.

Activate bootloader
Press ‘b’ to activate the bootloader. To activate the bootloader please enter the password: “StartBL”. As shown in the picture below, it will Reboot the convert and the Bootloader will be started. The bootloader ID will be printed, and the bootloader will be activated. Bootloader Menu will give options to load a new Firmware file, to read the current Firmware file, or to reboot the convert to close the bootloader and start the Firmware again.

Load New Application Firmware
Press ‘1’ to upload new Firmware. The firmware will be erased. Type ‘Yes’ only if a valid firmware file is received from Axiomatic Technologies to reflash. Bootloader flags will be erased. Which shows that the firmware is erased. Ready to flash new firmware? Yes/No: “Enter Yes or No and press enter.” Use Menu: File->Send File… with XON/XOFF control. Select the Firmware File (AF-22018-xx.yy.af) and select the “Binary File” options, where xx.yy represents the major and minor versions of the firmware, respectively.

AXIOMATIC-AX141550-Gigabit-Automotive-ethernet-Gigabit-Ethernet-Converter-
fig- \(11\)AXIOMATIC-AX141550-Gigabit-Automotive-ethernet-Gigabit-Ethernet-Converter-
fig- \(12\)

TECHNICAL SPECIFICATIONS

Specifications are indicative and subject to change. Actual performance will vary depending on the application and operating conditions. Users should satisfy themselves that the product is suitable for use in the intended application. All our products carry a limited warranty against defects in material and workmanship. Please refer to our Warranty, Application Approvals/Limitations and Return Materials Process as described at https://www.axiomatic.com/service/.

Power Supply Input

Power Supply Input – Nominal| 12 Vdc, 24 Vdc nominal (9 Vdc to 36 Vdc power supply range)
---|---
Protections| Surge protection is provided.

Reverse polarity protection up to -36 V is provided.

Input overvoltage (42 V) and input undervoltage (4 V) protection are provided.

Automotive Ethernet

Port Type| 1 port

1000BASE-T1 (IEEE 802.3 ab compliant) Automatic Polarity Correction (for 1000 Mbps mode)

Note: For 100 Mbps mode, polarity correction is not functional.

__

Default configuration: Slave (Master mode is configurable via RS-232 interface)

---|---
PHY| Marvell 88Q2112 (100BASE-T1/1000BASE-T1)
Protection| ESD protection for signal lines
Protocol| Automotive Ethernet

Ethernet IEEE 802.3bw for 100BASE-T1 (previously known as BroadR-Reach) Ethernet IEEE 802.3bp for 1000BASE-T1

Ethernet

Port Type| 1 port

1000BASE-T (IEEE 802.3 bp compliant) Auto-Negotiation

Automatic Polarity Correction

---|---
MDIX| Auto-MDI/MDIX (crossover)
PHY| Marvell 88EA1512 (100BASE-TX, 1000BASE-T)
Protocol| Ethernet IEEE 802.3
Protection| ESD protection for signal lines

Interfaces

User Interface for Reflashing RS-232
RS-232 1 3-wire RS-232 port

Configuration Baud Rate: 115200 kbit/s ESD and EFT protection for signal lines

RS-232 User Interface| Any terminal emulator that supports serial communication.

General Specifications

Functionality Can be configured to acts as a master or a slave
Microcontroller STM32F413CGU6
Quiescent Current Draw 100 mA @ 12 Vdc; 50 mA @ 24 Vdc

__

__

__

LEDs

| 3 GREEN LEDs
 | LED| ON| BLINK| OFF
Power| Power On|  | Power Off or Overvoltage/ Undervoltage Condition
Link| Ethernet Link Up| Ethernet Activity| Ethernet Link Down
ACT| Automotive Ethernet Link Up| Automotive Ethernet Activity| Automotive Ethernet Link Down
__

Compliance

| CE / UKCA marking ISO 13766-1:2018 RoHS
---|---
__

Vibration

| MIL-STD-202H, method 214A, test condition I/B Random Component: 7.56 Grms (8 hr/axis)

MIL-STD-202H, method 204D, test condition C

Sinusoidal Component: 10 g peak (8 hr/axis)

Shock| MIL-STD-202H, method 213B, test condition A Shock Component: 50 g peak
Operating Conditions| -40°C to 80°C (-40°F to 176°F)

Please see temperature ratings of cables under Mating Wire Harnesses.

Storage Temperature| -40°C to 85°C (-40°F to 185°F)
Protection| IP67
Weight| 0.15 lb. (0.068 kg)
Installation| The typical maximum wire harness length for Automotive Ethernet cabling is 15 m.
__

__

Enclosure and Dimensions

| See dimensional drawing Figure 2.0. Nylon 6/6, 30% glass fill, Encapsulation

UL 94V-0

Ultrasonically welded

Housing
AXIOMATIC-AX141550-Gigabit-Automotive-ethernet-Gigabit-Ethernet-Converter-
fig- \(13\)

Electrical Connectors

Mating Connectors| Mating connectors should meet the following standard for M12 Connectors, IEC 61076-2-101:2012. They should be A-coded.
---|---
Mating Wire Harnesses| The following part numbers are available from Axiomatic.

AX070535: Ethernet Cable 2 m (6.5 ft.), 8-pin M12 A-coded, Ethernet Jack

__

Note: Cable supplier is Phoenix Contact Network cable NBC-M12MR/2,0-94B/R4AC US – 1406112. The M12 connector on the harness assembly is rated for -20°C to 85°C and the RJ45 ethernet jack is rated as -20°C to 60°C.

AX070537: Cable 1.5 m (5 ft.), 8-pin M12 A-coded, Unterminated Leads (Details preliminary)

AXIOMATIC-AX141550-Gigabit-Automotive-ethernet-Gigabit-Ethernet-Converter-
fig- \(14\)

VERSION HISTORY

Version Date Author Modifications
1.0 October 16th, 2023 Weixin Kong Initial Draft
1B October 23, 2023 A.Wilkins Added CE marking, ISO 13766-1:2018
1C October 24, 2023 Weixin Kong Revise the Technical Data
1D October 24, 2023 A.Wilkins Added mating cable p/n AX070537
1E January 15, 2024 M Ejaz Added shock test results
January 23, 2024 M Ejaz Updated dimensional drawing

OUR PRODUCTS

  • AC/DC Power Supplies
  • Actuator Controls/Interfaces
  • Automotive Ethernet Interfaces
  • Battery Chargers
  • CAN Controls, Routers, Repeaters
  • CAN/WiFi, CAN/Bluetooth, Routers
  • Current/Voltage/PWM Converters
  • DC/DC Power Converters
  • Engine Temperature Scanners
  • Ethernet/CAN Converters,
  • Gateways, Switches
  • Fan Drive Controllers
  • Gateways, CAN/Modbus, RS-232
  • Gyroscopes, Inclinometers
  • Hydraulic Valve Controllers
  • Inclinometers, Triaxial
  • I/O Controls
  • LVDT Signal Converters
  • Machine Controls
  • Modbus, RS-422, RS-485 Controls
  • Motor Controls, Inverters
  • Power Supplies, DC/DC, AC/DC
  • PWM Signal Converters/Isolators
  • Resolver Signal Conditioners
  • Service Tools
  • Signal Conditioners, Converters
  • Strain Gauge CAN Controls
  • Surge Suppressors

OUR COMPANY
Axiomatic provides electronic machine control components to the off-highway, commercial vehicle, electric vehicle, power generator set, material handling, renewable energy and industrial OEM markets. We innovate with engineered
and off-the-shelf machine controls that add value for our customers.

QUALITY DESIGN AND MANUFACTURING
We have an ISO9001:2015 registered design/manufacturing facility in Canada. WARRANTY, APPLICATION APPROVALS/LIMITATIONS Axiomatic Technologies Corporation reserves the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice.

Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. Users should satisfy themselves that the product is suitable for use in the intended application. All our products carry a limited warranty against defects in material and workmanship. Please refer to our Warranty, Application Approvals/Limitations and Return Materials Process at https://www.axiomatic.com/service/.

COMPLIANCE
Product compliance details can be found in the product literature and/or on axiomatic.com. Any inquiries should be sent to [email protected].

SAFE USE
All products should be serviced by Axiomatic. Do not open the product and perform the service yourself. This product can expose you to chemicals that are known in the State of California, USA to cause cancer and reproductive harm. For
For more information go to www.P65Warnings.ca.gov.

SERVICE
All products to be returned to Axiomatic require a Return Materials Authorization Number (RMA#) from [email protected]. Please provide the following information when requesting an RMA number:

  • Serial number, part number
  • Runtime hours, description of the problem
  • Wiring set up diagram, application and other comments as needed

DISPOSAL
Axiomatic products are electronic waste. Please follow your local environmental waste and recycling laws, regulations and policies for safe disposal or recycling of electronic waste.

CONTACTS
Axiomatic Technologies Corporation 1445 Courtneypark Drive E.
Mississauga, ON
CANADA L5T 2E3
TEL: +1 905 602 9270
FAX: +1 905 602 9279
www.axiomatic.com
[email protected]
Axiomatic Technologies Oy

FINLAND
TEL: +358 103 375 750
www.axiomatic.com
[email protected]

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

AXIOMATIC User Manuals

Related Manuals