DESCRIPTION
Ultrabond ECO® 303 is a proprietary water-based adhesive formulation designed to be injected under existing wood, tile or resilient fiooring to full hollow spots or areas that have become unbonded. Once cured, Ultrabond ECO 303 provides a secure and elastomeric bond, reducing hollow sounds under foot and securing loose fiooring materials.
FEATURES AND BENEFITS
- Fixes hollow spots
- Secures loose flooring
WHERE TO USE
- For the repair of hollow spots and unbonded areas of installed wood, tile and resilient |oors
LIMITATIONS
- Do not install over any substrates containing asbestos.
- Use only when the substrate temperature is between 55°F and 100°F (13°C and 38°C).
SUITABLE SUBSTRATES
- Exterior-grade plywood and other approved wood underlayments (per the fiooring manufacturer’s recommendations)
- Concrete and cement terrazzo
- Existing ceramic tile
- Cement-based self-leveling underlayments and patching compounds
- Properly primed gypsum underlayments that meet the requirements for compressive strength per ASTM F2419
- Properly installed radiant-heating systems
Consult MAPEI’s Technical Services Department for installation recommendations regarding substrates and conditions not listed.
SURFACE PREPARATION
- All substrates must be structurally sound, dry, solid and stable.
MIXING
Before product use, take appropriate safety precautions. Refer to the Safety Data Sheet for details.
- This product is ready to use, with no mixing necessary.
PRODUCT APPLICATION
Read all installation instructions thoroughly before installation.
- Identify and locate the hollow spots in the floor by tapping with a wooden stick or broom handle.
- Drill a hole 1/8″ (3 mm) in diameter in the wood flooring, resilient flooring or grout line at each end of the unbonded area. Large hollow areas may require more holes. Vacuum up all debris from the drilled holes.
- Insert the cartridge into a suitable caulking gun, cut the tip and puncture the inner seal.
- Push the tip of the nozzle into each of the open holes and inject Ultrabond ECO 303 until it begins to ooze out of all holes, ensuring a complete fill of the hollow spot.
- Place a heavy weight on the repair surface and protect the area from foot traffic for 24 hours.
- After 24 hours, fill drill holes with an appropriately colored caulk, grout or wood patch.
CLEANUP
Immediately clean up any excess Ultrabond ECO 303 with a clean and damp white
cotton cloth or microfiber towel while the adhesive is still fresh/wet. Dried
residue will need to be removed by razor scraping or sanding.
Product Performance Properties
Laboratory Tests | Results |
---|---|
Polymer type | Latex polymer |
Solids content | 50% to 55% |
VOCs (Section 01350 of California’s CDPH) | Passed |
VOCs (Rule #1168 of California’s SCAQMD) | < 50 g per L |
Density | 8.3 lbs. per U.S. gal. (1.0 g per mL) |
Flash point (Tag) | > 200°F (93°C) |
Shelf Life and Product Characteristics
Shelf life | 1 year when stored in original, unopened packaging at 73°F (23°C) |
---|---|
Consistency | Smooth paste |
Color | White |
Service temperature | 55°F to 100°F (13°C to 38°C) |
Storage conditions | 50°F to 90°F (10°C to 32°C) |
Protect containers from freezing in transit and storage. Provide for heated
storage on site and deliver all materials at least 24 hours before work
begins.
Application Properties
at 73ºF (23ºC) and 50% relative humidity
Open time | 30 minutes |
---|---|
Curing time | 24 hours |
Packaging
Size
Cartridge: 10.5 U.S. oz. (311 mL)
ADDITIONAL INFORMATION
Refer to the SDS for specific data related to health and safety as well as
product handling.
For information on MAPEI’s commitment to sustainability and transparency, as
well as how MAPEI products may contribute to green building standards and
certification systems, contact
sustainability_USA@mapei.com (USA) or
sustainability-durabilite@mapei.com (Canada).
LEGAL NOTICE
The contents of this Technical Data Sheet (“TDS”) may be copied into another
project-related document, but the resulting document shall not supplement nor
replace requirements per the TDS in effect at the time of the MAPEI product
installation. For the most up-to-date TDS and warranty information, please
visit our website at www.mapei.com. ANY ALTERATIONS TO
THE WORDING OR REQUIREMENTS CONTAINED IN OR DERIVED FROM THIS TDS SHALL VOID
ALL RELATED MAPEI WARRANTIES.
Before using, the user must determine the suitability of our products for the
intended use, and the user alone assumes all risks and liability. ANY CLAIM
SHALL BE DEEMED WAIVED UNLESS MADE IN WRITING TO US WITHIN FIFTEEN (15) DAYS
FROM DATE IT WAS, OR REASONABLY SHOULD HAVE BEEN, DISCOVERED.
CONTACT INFORMATION
MAPEI Headquarters of North America
1144 East Newport Center Drive
Deerfield Beach, Florida 33442
1-888-US-MAPEI (1-888-876-2734) /
954-246-8888
Technical Services
U.S. and Puerto Rico:
Flooring: 1-800-992-6273
Concrete and heavy construction:
1-888-365-0614
Canada:
1-800-361-9309
Customer Service
1-800-42-MAPEI (1-800-426-2734)
Edition Date: December 12, 2023 MK 3000466 (23-3185)
For the most current product data and BEST-BACKEDSM warranty information,
visit www.mapei.com.
All Rights Reserved. © 2023 MAPEI Corporation.
2023-12-13
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>