NEURONIC Neuradiant 1070 Helmet User Manual
- June 4, 2024
- NEURONIC
Table of Contents
1070 Helmet
User Manual
Neuradiant 1070 Helmet
Please note this is not a medical device. This product is not intended to diagnose, treat, cure or prevent any disease. These statements have not been evaluated by the Food and Drug Administration.
Overview
Marvin H. Berman, Ph.D
Co-Founder and Clinician at Neuronic
Thank you for purchasing our product. We are excited for you to use our latest
device, the Neuradiant 1070. Our device is unique in that it uses the 1070nm
near-infrared wavelength and is the fi first device that gives the user the
option to control each quadrant of the helmet in correlation to four brain
quadrants (front, back, left, right).
[1] Research shows that photobiomodulation, which is the term used to express
the therapeutic use of light on the body, has many benefi social effects such
as improving the energy production in cells, accelerating blood fl ow, enabling
more oxygen circulation in the brain, and enhancing neuroprotective proteins
and growth factors.
Neuronic has partnered with the Quietmind Foundation, a nonprofi t research and
consultation organization in the USA, that has spent the last 25 years
conducting clinical and applied research involving the use of neurofeedback
and photobiomodulation. Neuronic is providing this state-of-the-art
photobiomodulation device, along with an hour’s brain health consultation with
a qualifi ed clinician, for instruction on how to get the best from your
device. [2]
Getting Started
Packing List & Accessories
Helmet | Fixation Sponges |
---|---|
Handbag | Instruction Manual |
Power Adapters | Quick Start Guide |
Control Box | Connection Cables |
Foam Headpiece | Velcro |
Set up
-
Fitting Guide
Remove the helmet and components from the case. Take the velcro strips from the adhesive paper and apply them to the inside of the helmet as shown in the diagram. Apply the sponges or foam headpiece onto the velcro so the unit is fi tested during use. Do not place any velcro on the clear plastic inside the helmet.
Bottom View
-
Turn on the Device
Connect the helmet with the controller, and connect the controller with the fi lost power adapter.
Connect the controller with the second power adapter. After connecting the cables, you can turn on the device via the button on the top right.
After connecting the cables, you can turn on the device via the button on the top right.
Consultation
A 1-hour consultation is offered to those who purchased the Neuradiant 1070
and is designed to ensure safe and effective use of the device for improving
general health and wellness. We will answer questions on the use of the
different programs, answer specifi c questions you may have, and construct a
‘real world’ set of metrics that will defi ne clinical progress. To book your
consultation, please email us at: team@neuronic.online
Customers who purchased the Neuradiant 1070 with the 4 quadrant function will
be provided with a code (see page 9) to access the clinical protocols and an
appointment link to arrange your 90-day personalized consultation.
Programs
The four default programs are designed to provide specifi c types of
stimulation to support the establishment of specifi c physical and mental
states. We recommend
using the device twice a day, morning and evening.
We do not recommend exceeding this daily use.
Program Inputs
Each program is unique and made up of three main inputs; time, pulse rate, and
intensity which are outlined below.
Time
The amount of time the program will run from start to fi nish. The unit will
make a beep at the start and end of the chosen program. The maximum time for a
program is 30 minutes.
Pulse Rate
The pulse rate is the frequency that the light fl ashes every second. At 10Hz
the light will fl ash 10 times per second, similarly, at 40Hz it will be 40
times per second. The maximum pulse rate is 9999 Hz.
Intensity
This refl ects the duty cycle of the light or the amount of time in which the
light will be on for every pulse. For example, if the light pulses at an
intensity of 25% once a second, it means that the light will remain on for
only 0.25 seconds. With the full intensity of 100%, no pulse rate can be set.
Program Descriptions
Understanding the default Programs
Each default program has been developed with different inputs. After running
the program, we recommend turning off the device. Notice the effects of the
device, if you feel positive effects and wish to continue the therapy, you can
increase in increments of 2 minutes each day, up to a maximum of 20 minutes.
Peace
This program uses a 10Hz pulse rate associated with alpha brain waves,
fostering a relaxed and restful state of consciousness. The light intensity is
low so you can enjoy a longer exposure time of 9 minutes. This program can be
used with meditation activities or other integrative mind-body awareness
practices to calm the central nervous system further.
Time | 9 min |
---|---|
Pulse Rate | 10 Hz |
Intensity | 25% |
Focus
The Focus program uses a 40Hz pulse rate associated with gamma brain waves.
Gamma brain waves have shown improved cognitive functioning, including short-
term memory, reaction time, mental fl exibility, and positive
neurophysiological effects. The recommended duration is 6 minutes. We
encourage starting with 3 minutes, pausing to notice how you feel before
continuing with the second 3-minute session.
Time | 6 min |
---|---|
Pulse Rate | 40 Hz |
Intensity | 50% |
Energize
The Energize program boosts cortical blood fl ow, giving more oxygen to the
brain. The 20Hz Beta brain waves help to increase attention and clarity. This
pulse rate is also associated with increased adenosine triphosphate (ATP)
production. The duration of this program is slightly shorter as the intensity
is higher, giving you a short burst of energy.
Time | 3 min |
---|---|
Pulse Rate | 20 Hz |
Intensity | 75% |
Glow
Encourages renewal and revitalization of cellular health, increasing blood fl
ow and aiding the removal of waste products. This program can be used for
supporting general brain wellness, and for recovery after a period of ill
health. This program also has cosmetic and dermatological applications as it
improves the blood fl ow to the skin by stimulating elastin that improves skin
appearance and enhances blood fl ow to the scalp and thus promoting hair growth
resulting in a truly healthy glow. This program does not use pulsing as the
intensity is set to 100%.
Time | 10 min |
---|---|
Pulse Rate | -Hz |
Intensity | 100% |
Custom Program
These are individualized programs developed in consultation with a qualifi ed
clinician. Each program is customized to effi ciently achieve your personal
wellness goals.
Time | -min |
---|---|
Pulse Rate | -Hz |
Intensity | – % |
Clinical Protocols & 4 Quadrant Functionality Clinical Protocols are
exclusively for use with the 4 quadrant feature which can only be used when
purchased within 3 months of consultation with a qualifi ed clinician. If you
have bought the Neuradiant 1070 and wish to upgrade the device, please contact
Neuronic at team@neuronic.online
There is growing recognition in the neuroscience community regarding the role
of brain networks as being a primary driver in overall brain performance. Effi
client communication among and between brain networks is a principal focus in
developing effective digital neurotherapeutic (DN) applications. Neuronic is
contributing to the advancement of DN applications with the introduction of
the Neuradiant 1070 with 4 quadrant function, by providing independently
programmable pulse frequency, intensity, and duration to four key brain
quadrants (front, back, left, right) and thereby allowing users to defi ne
specifi c regions for customized stimulation protocols.
Clinical Protocol Passcode:……………………………..
Note: Only available with 4 quadrant devices.
The image below is the control settings for the 4 quadrants feature and should
be used under the guidance of a qualifi ed clinician.
In order to optimize the benefi t for each user, we include a personalized
consultation process. The consultation process has 3 basic components;
assessment, protocol design, and implementation, as well as continuous
integration. Each individual has their own case history, resources, and
expectations and therefore the goal of the consultation is to understand and
incorporate those factors into the Neuradiant 1070 protocol(s) they’ll be
using.
The initial consultation will include a thorough review of the personal
assessment materials the user will have previously completed and returned to
Neuronic. The review of past experiences and concerns will support the
consultant in advising on the photobiomodulation protocol design, establishing
‘real world’ metrics for evaluating progress, and suggestions for obtaining
further consultation or support. At this time, users will be instructed and
practice the safe and effi cient use of the Neuradiant 1070 and how to modify a
protocol.
Safety Guidelines
General Guidelines
Photobiomodulation demonstrates a dose-response curve which means that there
is a ‘sweet spot’ wherein the stimulation has the most positive impact on our
cells and tissues. Too little stimulation provides little benefi t, and too
much stimulation can cause a diminishment of response.
We therefore strongly suggest that users accept two basic principles:
- More is not necessarily better. We’ve seen many instances wherein the best results come after relatively small amounts of stimulation, especially when it is delivered with the right pulse frequency and intensity.
- Indications that you have had too much light stimulation can occur during or shortly after (30 seconds to 10 minutes) completing a protocol. They can also appear after a few hours. If you know you are particularly sensitive to energetic or pharmaceutical stimulation in general, then we suggest that you use the device for a few minutes initially and build up the usage gradually. If indications persist, consult your healthcare professional and contact Neuronic for additional support.
Helmet & Adapter Use Precautions
Please only use the adapter and transformer provided by the manufacturer to
ensure the normal operation of the device. The company is not responsible for
product failure caused by the self-assembly or disassembly of the product.
Please discontinue using the device if wet or there is visible damage to the
helmet, adapter, or cables, this includes usage in conditions of high humidity
or temperature.
Our company does not bear any responsibility for the damage or any
accidents caused by improper use.
Service Guarantee
You can return the device within the fi first 30 days for free. Additionally,
we have an 80% refund policy, valid for three months from the time of purchase
if our devices
do not help you. Our product is covered with a 12-month warranty.
Disclaimers
Our product cannot guarantee the same effects on each individual. There are no
known side effects of using our device. Still, we advise you to consult your
local doctor and conduct your independent research before purchasing our
device.
These statements have not been evaluated by the Food and Drug Administration.
This product is not intended to diagnose, treat, cure or prevent any disease.
Please note this is not a medical device.
The focus of our consultation(s) is on the safe and effective use of the
Neuradiant 1070 photobiomodulation device and is not to be considered medical
advice, nor is it in any way to be considered a replacement for consultation
with your current medical or other qualifi ed healthcare providers.
Appendix
[1] Treatment of Neurodegeneration: Integrating Photobiomodulation and Neurofeedback in Alzheimer’s Dementia and Parkinson’s by Marvin H. Berman and Trent W Nichols
https://pubmed.ncbi.nlm.nih.gov/31647776/
[2] Therapeutic Effects of Near Infrared Light Stimulation on Cognitive and Behaviour Symptoms of Dementia by Marvin H. Berman, Damir Nizamutdinov, Xiaoming Qi, Jason Huang, and Gordon Dougal.
Product Parameters
Product Name| Neuradiant 1070nm| |
---|---|---|---
Model Number| GY-PDT1| Wave Length| 1070nm
LED Numbers| 256 pcs| Power| 50mw/pc
Total Power| 15W| Optical Power| 24mw/cm2
Input Voltage| 100-240 V| Work Voltage| 5V ~ 6A
Input Current| 800mA| Frequency| 0-9999 Hz
Neuronic Devices Limited
Lacka, Carrig, Birr, Co. Offaly Ireland
Neuronic Devices Operations GmbH
Am Kindergarten 1, 57482 Wenden Germany
neuronic.online