JIGOO T600 Bed Mattress Vacuum Cleaner User Manual

May 15, 2024
JIGOO

T600 Smart Mite Cleaner
User ManualJIGOO T600 Bed Mattress Vacuum Cleaner

Please read this manual carefully before use and keep it safe for future reference.

Important Safety Instructions

When using an electrical appliance, basic safety instructions should always be followed, including the following:
Read all instructions before using.
WARNING – To reduce the risk of fire, electric shock, or injury:

  1. Don’t leave the vacuum cleaner alone when the power is on. Unplug the machine when not in use or before removing filter.
  2. Do not use outdoors or on wet surfaces.
  3. Do not allow to be used as a toy. Close attention is necessary when used by or near children.
  4. Use only as described in this manual. Use only manufacturer’s recommended attachments
  5. Do not use with damaged power cable or if appliance is not working as it should, has been dropped, damaged, left outdoors, or dropped into water, return it to a service center.
  6. Do not pull or carry by cord, use cord as a handle, close a door on cord, or pull cord around sharp edges or corners. Do not run appliance over cord. Keep cord away from heated surfaces.
  7. Do not unplug the machine by pulling on cord. To pull the plug, grab the plug, not the cable.
  8. Do not handle plugs or machines with wet hands.
  9. Do not put any object into openings. Do not use with any opening blocked; keep free of dust, lint, hair, and anything that may reduce air flow.
  10. Keep hair, loose clothing, fingers, and all parts of body away from openings and moving parts.
  11. Turn off all controls before unplugging.
  12. Be extra careful when cleaning on the stairs.
  13. Do not use to pick up flammable or combustible liquids, such as gasoline, or use in areas where they may be present.
  14. Do not pick up anything that is burning or smoking, such as cigarettes, matches, or hot ashes.
  15. Do not use without filters in place.
  16. UV emitted from this lamp. Skin or eye injury could result. Avoid exposure of eyes and skin to unshielded lamp.
  17. Eye damage may result f rom directly viewing the light produced by the lamp in this apparatus. Always turn off lamp before opening this cover.
  18. This cover is provided with an interlock to reduce the risk of excessive ultraviolet radiation. Do not defeat its purpose.
  19. All serving of UV lamp should be performed by qualified personnel.

SAVE THESE INSTRUCTIONS
For household use only
To reduce the risk of electric shock, this appliance has a polarized plug (one blade is wider than the other). This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not change the plug in any way.
Declaration
Conforms to the applicable provisions of applicable US Federal requirements, including CFR 21, Part 1040, Chapter 1, Subchapter J, Radiological Health
Preface
Dear customer:
Thank you for using the JIGOO Mite Cleaner.
The content in the manual is for reference in use and maintenance. For matters not covered, please consult our customer service.

Product Introduction

Packing List

  • Mite Cleaner x 1
  • Filter Sponge x 1
  • Aroma Capsule x 2
  • User Manual x 1
  • Cleaning Brush x 1

Names of Parts

1. Roller brush window 7. Speed button
2. Aroma container 8. Power switch
3. Dust cup 9. Filter
4. Dust cup release button 10. Filter sponge
5. Cyclone cup 11. Support of filter sponge
6. Display
  1. Speed mode
  2. Dust mite digital display
  3. Function
  4. Ultrasonic generator
  5. UV lamp
  6.  Heating outlet
  7. Bottom plate lock
  8. Roller brush
  9.  Bottom plate

Instructions for Use

  • Put the Smart Mite Cleaner on the bed, connect to the power supply, press the power switch and gently push it back and forth to clean.
    Tips:

  • There is no need to lift up or hold down the Mite Cleaner forcefully; simply put it on the bed and push it back and forth;

  • In order to avoid injury, the UV lamp must be within 3cm of the irradiated object and the inclination angle of the machine should not exceed 30°. Outside of this range, the UV lamp will automatically turn off;

  •  To avoid injury, do not look directly into the UV ray.

  • To safely check that the UV lamp is working properly, hold the machine up within a distance of 5cm from the irradiated object and see if there is a UV light spot on the object. Do not look directly at the UV lamp.

  • It is normal that some odors are discharged from the air outlet of the Smart Mite Cleaner when it is used for the first time.They will not harm human health and will naturally disappear later;

  • The high-speed airflow sound generated by the Smart Mite Cleaner is normal.

Cleaning frequency
At first, it is recommended to use the Smart Mite Cleaner 2-3 times a week; later, it is recommended to use once a week.
Note:

  • When the machine is not used for a long time, please take the aroma capsule out of the container and place the machine in a cool and dry place, away from direct sunlight and moisture.
  • When it is used for the first time, there will be more garbage; with use, the garbage will reduce accordingly.
  • After use, clean the dust barrel assembly.

Maintenance

Dust cup cleaning

  1. Push the dust cup release button and remove the dust cup.
  2. Remove the lid of the dust cup.
  3. Empty the dust cup.
  4. Align the bump on the lid with the hollow on the dust cup and close the lid tightly.
  5. Install the dust cup.

Cyclone cup cleaning

  1. Rotate the right lid of the cyclone cup counterclockwise to open it and remove the filter from the cyclone cup.
  2. Remove the support of the filter sponge from the filter and take out the filter sponge from its support.
  3. Clean the filter and sponge. The sponge can be washed with water. (The filter and sponge should be completely dry before putting them back into the dust cup.)
  4. Put the filter sponge back into the support and then place the support back into the filter.
  5. Place the filter back into the cyclone cup and rotate the lid of the cyclone cup clockwise to secure the lid.

Tips:

  • It is recommended to clean the dust barrel and filter sponge after each use; if the dust barrel is full in use, it is recommended to clean it immediately, or else it will affect the effect.
  • Do not scrub the filter sponge violently when cleaning; after washing the dust barrel assembly, make sure that all the parts are completely dry before putting it into the main unit.
  • After the cumulative use time of the filter sponge reaches 30-50h, it is recommended to replace it to avoid degrading the performance of the machine.
  • If the filter part is forgotten to install and the machine is already turned on, please turn off the machine immediately and clean the cyclone cup. (Rotate the left lid of the cyclone cup counterclockwise to open it and clean the inside of the cyclone cup. Close the lid by rotating it clockwise after cleaning.)

Aroma capsule replacementJIGOO T600 Bed Mattress Vacuum Cleaner -
capsule replacement

  1. Turn off the machine and rotate the aroma container counterclockwise to remove it f rom the machine.
  2. Rotate the lid of the aroma container counterclockwise to open it.
  3. Remove the aluminium foil f rom the aroma capsule.
  4. Place the aroma capsule into the container and close the lid tightly.

Instruction of aroma function

To reduce the aroma and slow down the aroma diffusion;
+ To increase the aroma and accelerate the aroma diffusion;
To minimize the aroma diffusion and prolong the use of the aroma capsule;
To unlock the aroma container and replace the aroma capsule;

Note:
Please clean the aroma container and check the remaining aroma regularly to ensure that the container rotates smoothly and the aroma functions effectively.
Roller brush cleaning

  1. Turn off the machine and unplug it. Slide the bottom plate locks up like the picture shows to unlock the bottom plate.
  2. Remove the bottom plate and roller brush, and then clean the roller brush.

Warning:
The machine must be switched off and unplugged when you clean the roller brush.
UV lamp cover cleaning
UV lamp cover (transparent)  
Note:

  • Please wipe the transparent cover of the UV lamp before use to ensure the best sterilization effect;
  • Cut off the power when cleaning, repairing or temporarily not using the machine.
  • Don’t look directly into the UV ray.
  •  Keep the UV ray away from your skin.

Troubleshooting

Please check the following issues and solutions before sending the product to designated repair offices.

Failure Possible causes Solutions
The machine does not work •The power plug is not inserted tightly.

•There is no electricity at the power socket.
•The power switch is not pressed.| •Check whether the power plug is inserted tightly.
•Check the socket.
•Press the power switch.
The suction force becomes smaller| •The suction port is blocked.
•There are too many foreign objects in the filter sponge.
•There are many foreign
objects in the cyclone.| •Clean the suction port.
•Clean the dust barrel and filter sponge.
•Clean up foreign objects in the cyclone.
The UV lamp does not work| •The two rollers under the machine do not touch the surface of the object at the same time.
•The two rollers under the machine are stuck and can’t move freely.
•The UV lamp is damaged.| •Place the machine flat on the object and ensure that both rollers are compressed.
•Clean the rollers to ensure that the two rollers can move up and down freely or contact after-sales service.
•Contact after-sales service to replace the UV lamp.
Failure| Possible causes| Solutions
---|---|---
The machine suddenly stops working| •  The dust barrel is full.
•  The suction port of the  machine is blocked.
•  The cyclone is blocked  by foreign matter.
•  The machine is  damaged.| •  A safety mechanism  has been added to  prevent overheating. If  this happens, please  stop using, clean up  the blockage, and
pause for two hours  before using again.
•  Contact after-sales  service.
The roller brush suddenly stops working| •  The roller brush is  wrapped by foreign  objects.
• The belt falls off or  breaks.| •  Take out the roller  brush as required and  clean it before using.
•  Contact after-sales  service to replace the  belt.

Specifications

Technical Parameters

Model T600
Rated voltage 120V 60Hz
Rated current 4A
Dust collection volume 0.5L

Note

  • This product is an electric appliance, do not let it run unattended.
  • If you do not use this product for a long time, please turn off the power and unplug the machine.
  • Unplug the machine with dry hands to avoid electric shock.
  • Disconnect the power supply when cleaning, servicing or when the machine is not in use for a while.
  • Do not let the power cord pass through sharp objects and avoid dragging the cord to move the machine as this may damage the cord.
  •  Do not use the machine to absorb hot objects such as carbon, cigarette butts, and sharp objects such as broken glass, corrosive liquids, gasoline, alcohol and other flammable and explosive items, or else it may damage the machine or cause a fire, resulting in personal injury and other accidents.
  • Do not use this product to absorb water or wet dust. Don’t expose the machine to rain or water, or use it in wet places (e.g. bathrooms, toilets, laundry rooms, etc.) to avoid malfunction.
  • Keep the machine away from heating appliances and avoid exposure to sunlight to avoid fire.
  • Do not let children play with or use the machine in order to avoid accidents.
  • Avoid prolonged operation with the suction port blocked to avoid damage to the machine.
  • Avoid looking at the bottom of the machine when it is switched on to prevent damage from UV rays.   Do not expose plants to UV rays to avoid damage to plants. Do not concentrate the UV rays in one place for continuous use as this may cause damage to objects.
  • Do not sit on this product to avoid damage to the machine.
  • Do not remove the brush roll assembly while the machine is powered or running to avoid damage.
  • This product can be used to clean and remove mites from mattresses, blankets, pillows, sofas and other textiles.
  • If the power cord is damaged, it must be replaced by qualified personnel f rom a designated maintenance center to avoid danger.

Environment

  • Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities.
  • Contact your local government for information regarding the collection systems available.
  • If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being.
  • When replacing old appliances with new ones, the retailer is legally obligated to take back your old appliance for disposals at least free of charge.

Compliance Statements
The ETL Mark is proof of product compliance to North American safety standards. Authorities Having Jurisdiction(AHJs) and code officials across the US and Canada accept the ETL Listed Mark as proof of product compliance to published industry
standards. Retail buyers accept it on products they’re sourcing.
**** This symbol indicates that the product is capable of being recycled.
This symbol indicates that the product should not be disposed of as household waste. The product must be sent to separate collection facilities for recovery and recycling of electrical and electronic equipment.
This symbol indicates that the product should be kept away from rain and in dry conditions.
 The warning sign indicates a potential hazard, danger, obstacle, or condition requiring special attention.

JIGOO T600 Bed Mattress Vacuum Cleaner - icon 4Made in China

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals