Product: V9-Gé60 Electric Bicycle Intelligent LCD
Meter Model: SX985
Specification
- 24V/36V/48V Power Supply
- Rated operating power of the instrument: 15mA
- Maximum operating current of the instrument 30mA
- Shutdown leakage current: <1uA
- Power supply to the controller: 50mA
- Working temperature: -20 ~ 60°C
- Storage humidity: -30 to 70°C
Appearance And Parameters
3.1 View Sth From The Outside
Figure 3.1 Physical diagram of the meter and keypad
3.2 Appearance Size(unit:mm)
Picture 3.2.1 SX985 Instrument Front View Dimensions
Figure 3.2.2 SX985 Instrument Side View Dimension Drawing
Functionality
4.1 Functional Overview
The SX985 gauge offers a wide range of features to suit your riding needs,
content includes:
- Speed display (including real-time speed, maximum speed, average speed)
- Boost Gear Adjustment and Indication
- Battery level display
- Error icon display
- Mileage display (both single and total)
- Cruise control
- Headlamp control and indication
- Facilitating the introduction of controls and instructions
4.2 Button Definition
There are five keys on the corresponding operating unit of the SX985
instrument: on/off key, plus key, minus key and toggle key.
4.3 Functional Area Distribution
Figure 4.3 SX985 Functional Area Distribution Interface
Routine Operation
5.1 Switch On/Off
long press : key for 2 seconds, the meter starts to work and turn on the
working You can switch off the power of the controller. In the power-on state,
long press the key electric car Power Supply. The meter will automatically
switch off if the electric vehicle is not used for more than 10 minutes.
5.2 Display Interface Switching
When the instrument is switched on, the instrument displays real-time speed
(km/h) and total mileage (km) by default. Short press the M key to display
information to switch between total mileage (km), single mileage (km), maximum
speed (km/h), and average speed (km/h).
5.3 Assisted Push And Cruise Control
Long press when the electric vehicle is stationary For 2 seconds, the e-bike
enters the assisted travelling mode. The e-bike will travel at a fixed speed
of 6 km/h. The display shows and symbols Display. Release the button and the
e-bike will exit the walk assist mode. When the e-bike is in riding mode, long
press the 2s enters the real-time cruise mode and cancels the cruise if it is
currently in cruise mode.
Figure
5.3 Boost implementation display screen
The power push function can only be used when the user is pushing, please do
not use it while riding.
5.4 Switch On/Off The Headlights
Long press key for 3 seconds to turn on the headlight, the instrument
backlight is dimmed; short press the key again to make the controller turn off
the headlight,the instrument backlight returns to brightness.
Figure
5.4 Turn on the backlight display interface
5.5 Boost Gear Selection
Short press key to switch the electric vehicle power assist gear, thus
changing the motor output power.
Figure 5.5 Gear switching display interface
The icon is always on to show the pure electric and power assisted modes,
without this icon it is pure electric mode, and with this icon blinking it is
pure power assisted mode.
5.6 Battery Level Display
Battery percentage display, when the battery is fully charged the meter will
show 100% and the indicator bar is fully lit (red bar + green bar), when the
battery is undervoltage the battery outer bezel blinks. suggesting that it
needs to be recharged immediately.
Figure
5.6 Battery level display screen
5.7 Error icon display
When there is a malfunction in the electric control system of the electric
vehicle, the instrument will automatically display an error code, see the
following for the detailed definition of the error code.
Figure
5.7.1 Error Code Display Screen
Error Icon | Define |
---|---|
Motor Failure | |
Failure of the speed control handle |
|
Controller Failure
| Brake Failure
Figure 5.7.2 Error Code Contents
When an error code appears on the display interface, please troubleshoot the
problem in time, the electric car will not be able to drive normally after the
problem occurs.
Parameterisation
Each setting item needs to be carried out when the vehicle is stationary. The operation steps of parameter setting are as follows: In the power-on state, when the instrument shows the speed as 0,
- Simultaneously press and hold the and key for more than 2 seconds to enter the parameter setting item selection interface;
- Short press the button to switch the parameter setting item selection interface, short press the or button to enter the parameter changing state;
- Short press key to save the parameter setting and return to the parameter setting item selection interface;
- Long press and key to exit the parameter setting item selection interface.
The following options are available on the personalisation parameter selection
screen.
6.1 Backlight Brightness
Level 1 is the darkest and level 3 is the brightest. Press and Enter parameter
change status or Select the parameter and press preservation parameter setting
and returns to the parameter setting screen.Figure 6.1 Backlight Brightness Setting
Interface
6.2 Metric Unit Setting
P02 is the metric/imperial unit setting option, where 0 represents kilometres
and 1 represents miles. The default is kilometres. Press the buttons and atthe
same time to enter the parameter change status, short press the or button to
select parameters, short press the button to save the parameter settings and
return to the parameter setting item selection interface;
Figure 6.2 Metric and Imperial Units Setting Screen
6.3 Rated Voltage Setting
PO3 is the rated voltage setting option, which can set the rated voltage
range: 24V, 36V, 48V.
Figure 6.3 Rated Voltage Setting Screen
6.4 Sleep Time Setting
P04 is the auto power off time setting option, in order to save the power of
the whole vehicle to get a higher range, this instrument is equipped with a
long time without any operation auto power off function. The range of auto
shutdown time can be set as follows: ~60min, 0 means no
Figure 6.4 Auto Power Off Time Setting Screen
6.5 Boost Gear Range Setting
P05 is the booster gear range setting option, the available booster gears for
the instrument are: 0~3 gears, 1~3 gears, 0~5 gears, 1~5 gears.
Figure 6.5 Boost Gear Range Setting Interface
6.6 Wheel Diameter Setting
P4 is the wheel diameter setting option, the instrument adjustable wheel
diameter range is: 8~50inch, the accuracy is 0.1.
Figure 6.6 Wheel diameter setting interface
6.7 Velocimetry Sensor Magnet Count Setting
P07 is the setting option for the number of magnets of the speed sensor, and
the adjustable range of the number of magnets of the instrument is 1~100.
Figure 6.7 Velocimetry Sensor Magnet Count Setting Screen
6.8 Speed Limit Setting
P08 is the speed limit setting option, the speed limit adjustable range of the
instrument is: 1 50km/h. 50 means no speed limit.
Figure 6.8 Speed limit setting interface
6.9 Zero Start, Non-Zero Start Settings
0: zero start; 1: non-zero boot;
Figure 6.9 Zero Start, Non-Zero Start Setting Setting Screen
6.10: Drive Mode Setting
0: Enabling drive
1: Electric drive
2: Simultaneous coexistence of power-assisted and electric drivesFigure 6.10 Driver mode setting screen
6.11 Boost Sensor Sensitivity Setting
P11 is the booster sensor sensitivity setting option with a setting range of
1-24, where 1 means the highest sensitivity and 24 means the lowest
sensitivity.
Figure 6.11 Boost Sensor Sensitivity Setting Screen
6.12 Boost Start Strength Setting
P12 is the booster start strength setting. Range: 0-5;
Figure 6.12 Boost Start Strength Setting Screen
6.13 Helper Magnet Counting Disc Type Setting
P13 is the pedal assist sensor magnets setting. The adjustable range is:
5/8/12.
Figure 6.13 Booster Magnet Disc Type Setting Screen
6.14 Controller Current Limit Value Setting
P14 is the controller current limit setting option, the instrument
controller current limit adjustable range is: 1~20A. default 12A.
Figure 6.14 Controller current limit setting interface
6.15 Tobedeveloped To Be Developed
6.16 Single Zero Setting
Long press key for 5 seconds ODO clear.
Figure 6.14 Controller current limit setting interface
Wiring Diagram
7.1 Standard Connector Wiring Sequence
Figure 7.1 wiring diagram
Standard Wiring Sequence| Standard Cable Colours| Functionalit
y
---|---|---
1| Red (VCC)| Instrument Power Cord
2| Blue (Kp)| Controller Power Cord
3| Black (GND)| Instrument ground
4| Green (RX)| Data receiving line of the instrument
5| Yellow (TX)| Instrument data transmission line
Figure 7.1 Standard Connector Wire Sequence Table
Some models are equipped with waterproof connectors and it is not possible to
see the colour of the internal wires.
Settings
P01: Backlight brightness, level 1 is the darkest and level 3 is the
brightest;
P02: Mileage unit, 0: KM; 1: MILE;
P03: Voltage level: 24V, 36V, 48V, default 36V;
P04: Sleep time: 0, no sleep; Other numbers refer to sleep time, ranging from
1 to 60; Unit minute;
PO5: Power assisted gear: 0, 3rd gear mode: 1st gear 2V, 2nd gear, 3V, 3rd
gear, 4V; 1st and 5th gear modes: 1st gear 2V, 2nd gear 2.5V, 3rd gear 3V,4th
gear, 3.5V, 5th gear, 4V;
P06: Wheel diameter: unit, inch; Accuracy: 0.1;
P07: Speed measurement magnetic steel number: range: 1-100;
P08: Speed limit: Range 0-50km/h, where 50 indicates no speed limit,
1. Non communication state (instrument control): When the speed is greater
than the set speed, the PWM output is turned off; When the speed drops below
the set speed, the PWM output is automatically turned on, and the driving
speed is + 1km/h of the current speed; (Only for power assisted speed limit,
no speed limit for the handlebar)
2. Communication status (controller control): The driving speed is maintained
at the set value, with an error of + 1km/h; (Speed limit for power assistance
and rotating handle) Note: The value here is based on kilometers. When the
unit setting is converted from kilometers to miles, the speed value on the
display interface will automatically be converted to the correct mile value.
However, the speed limit data set in this menu under the mile interface will
not be converted, which is inconsistent with the actual displayed mile speed
limit value;
PO9: Zero start and non zero start settings, 0: Zero start; 1: Non zero start;
P10: Drive mode setting 0: Power assisted drive (how much power is output is
determined by the power assisted gear, at this time The transfer handle is
invalid.
1: Electric drive (driven by a rotating handle, at which point the assist gear
is invalid).
2: Assisted drive and electric drive coexist simultaneously (invalid in zero
start state of electric drive).
P11: Assist sensitivity setting range: 1-24;
P12: Power start intensity setting range: 0-5;
P13: Three types of magnetic steel discs for assistance: 5, 8, and 12 magnetic
steel discs
P14: Controller current limit setting default 12A range: 1-20A
P15: Function not yet activated
P16: ODO reset setting: Press and hold the up button for 5 seconds to reset
ODO